PubMed Health⌕ Search

Biomedical subjects

R F Ribeiro

Publications and source records attributed to R F Ribeiro.

14 recordsLinked to original sources

Electromyographic evaluation of the adductor pollicis muscle of elderly patients carriers of removable partial prosthesis when using acrylic devices adapted to the handle of toothbrush.

The aim of this study was to evaluate the muscular activity of the adductor pollicis muscle, by electromyography, when using a device made of acrylic resin adapted to the handle of toothbrush. 10 patients of both sexes from the Clinic of Removable Partial Dentures of the Dental School--USP, with a mean age of 65 years, were selected. Electromyographic records were obtained with patients in clinical conditions of Initial Rest and under conditions of claw apprehension and dental brushing. The mean results obtained, in mV, were: sat men: 2.97 for rest (R); 11.55 for free closure (FC); 35.80 for strained closure (SC); 29.30 for simulated brushing (SB); 55.00 for brushing (B); 26.87 for simulated brushing with the device (SBA); 69.70 for brushing with the device (BA); 3.72 for post exercise rest (PR). Standing: 2.27 for rest (R); 13.92 for free closure (FC); 45.85 for strained closure (SC); 28.40 for simulated brushing (SB); 72.07 for brushing with the device (BA); 1.42 for postexercise rest (PR). Sat women: 9.78 for rest (R); 22.71 for free closure (FC); 41.48 for strained closure (SC); 26.45 for simulated brushing (SB); 52.78 for brushing (B); 17.00 for simulated brushing with the adapter (SBA); 42.38 for brushing with the adapter (BA); 14.40 for postexercise rest (PR). Standing: 5.26 for rest (R); 17.81 for free closure (FC); 46.55 for strained closure (SC); 40.61 for simulated brushing (SB); 61.71 for brushing (B); 26.08 for simulated brushing with the adapter (SBA); 54.06 for brushing with the adapter (BA); 3.46 for postexercise rest (PR). The adductor pollicis muscle showed a higher electromyographic activity, considered statistically similar to each other, in 3 clinical conditions analyzed: brushing (B), brushing with the adapter (BA) and strained closure (SC). The adductor pollicis muscle showed lower electromyographic activity, considered statistically similar, in 5 clinical conditions analyzed: simulated brushing (SB), simulated brushing with the adapter (SBA), free closure (FC), rest (R) and postexercise rest (PR).

Acrylic Resins↗

Castability and resistance of ceramometal bonding in Ni-Cr and Ni-Cr-Be alloys.

STATEMENT OF PROBLEM: Because of its pathogenic potential, the importance of the use of beryllium with Ni-Cr alloys must be determined. PURPOSE: This study compared fundamental properties for the clinical use of Ni-Cr alloys, determining the advantage of the addition of beryllium, despite the involved risks. MATERIAL AND METHODS: Two Be-free commercial alloys (Vera Bond II and Wiron 99) and 1 Be-free experimental alloy (E3) with Nb and/or Mo in their formulations and 1 experimental Ni-Cr alloy (E4) with 1.1% Be were submitted to ceramometal bonding resistance, castability, and hardness tests. RESULTS: Analysis of variance showed significant differences (P=.05) between Vera Bond II and Wiron 99 (Be-free) and the E4 alloy for the castability test. Vera Bond II, Wiron 99, and E4 presented higher castability values than E3. There were no statistically significant differences for the ceramometal bonding resistance test. The Kruskal-Wallis test showed significant differences (P=.01) among the alloys with Rockwell 30 T values for the hardness test. CONCLUSION: Within the limitations of this study, the presence of Be in Ni-Cr alloys was not necessary to guarantee the castability and the ceramometal bond resistance of the alloys tested.

Analysis of Variance↗

Device for recording the path of insertion for removable partial dentures.

Some negative outcomes of oral rehabilitation using removable partial dentures (RPDs) can be prevented when the framework of the RPD is planned with mounted diagnostic casts that have been analyzed in a dental surveyor. Recording the established path of insertion can be difficult when the procedure uses a pin that is cemented in the cast base, and the casts are mounted in an articulator. This article presents a procedure for a pin device to record the path of insertion of RPDs. This device serves the same purpose as the cemented pin but can be easily removed and replaced.

Dental Articulators↗

A clinical evaluation of materials for interocclusal registration in centric relation.

Four techniques for interocclusal registrations of centric relation based on materials or combinations of materials usually utilized were tested by means of mounting of casts for a patient with partial lower edentulousness, without a free end saddle. To ensure the correct position of centric relation a Lucia jig was utilized. The following conditions for the record of posterior section were tested: registrations with wax, wax plus zinc oxide-eugenol paste, wax plus Duralay acrylic resin, and condensation silicone (putty). The evaluation was made by the measure of vertical distance between reference points in the base of the casts and calculation of variations occurring with each material. The combinations of wax plus zinc oxide-eugenol paste and wax plus Duralay acrylic resin showed the smallest variations in centric relation position.

Acrylic Resins↗

Effect of beryllium on the castability and resistance of ceramometal bonds in nickel-chromium alloys.

STATEMENT OF PROBLEM: Castability and ceramometal bond resistance play an important role in accepting nickel-chromium alloys as a substitute for gold alloys in dentistry. PURPOSE: This study was developed to verify the effect of beryllium on these factors in several compositions of nickel-based alloys by submitting them to castability and ceramometal bonding resistance tests. MATERIAL AND METHODS: Three experimental compositions of Ni-Cr alloys with different amounts of beryllium were used. One beryllium-free alloy was used as the control. RESULTS: Analysis of variance and Tukey's test showed significant differences (alpha = .001) for the castability test results and significant differences (alpha = .05) for ceramometal bond resistance between alloys. CONCLUSIONS: Although the amounts of chromium, manganese, and niobium were maintained, the variations in the amounts of beryllium allowed the estimation that Be-containing alloys presented better castability than Be-free alloys. The 0.9% Be-containing alloy demonstrated higher resistance of the ceramometal bond than the Be-free alloy.

Analysis of Variance↗

Maintenance of prosthetic treatment in a geriatric patient--case report.

A 76-year old female patient came to the Specialized Clinic for Long-Lasting Dentures of the Dental School of Ribeirão Preto, USP, for prosthetic treatment for the correction of the absence of several teeth. The patient's medical history and examination revealed the presence of psoriasis that had progressed to a rheumatoid arthritis-like condition causing motor deficits such as difficulty in picking up and holding a toothbrush. We proposed two acrylic removable partial dentures, with a chromium-cobalt metal support planned for the lower denture. For the maintenance of oral hygiene we proposed an acrylic resin device coupled to the toothbrush in order to increase the volume of the toothbrush, and consequently facilitate tooth brushing. This device, although simple, has permitted the patient to have a more independent and healthy life style.

Aged↗

Surveying removable partial dentures: the importance of guiding planes and path of insertion for stability.

STATEMENT OF PROBLEM: Although removable partial dentures are a favored option for the restoration of many situations that involve partial tooth loss, some patients are not satisfied with a removable partial denture, especially when it is not stable during mastication. A dental surveyor can be used to prevent countless problems related to the production of removable partial dentures. Many professionals working with oral rehabilitation fail to take advantage of the many uses of a surveyor in planning and designing chromium alloy and other metal removable partial denture frameworks. PURPOSE: This article uses an academic approach to describe the criteria used to determine the path and removal of a removable partial denture. A fundamental requirement for understanding the correct use of the dental surveyor is to prevent indiscriminate use of a path of insertion perpendicular to the occlusal plane, and extreme inclinations of the cast in the attempt to create undercuts on some teeth.

Chromium Alloys↗

The prevalence of disc displacement in symptomatic and asymptomatic volunteers aged 6 to 25 years.

The purpose of this investigation was to determine a possible association between disc displacement and temporomandibular disorders (TMD). Fifty-six Brazilian asymptomatic volunteers (25 males and 31 females) and 181 symptomatic TMD patients (112 females and 69 males) participated. Volunteers did not have temporomandibular joint pain, limited jaw opening, joint sounds, or previous TMD treatment. Bilateral temporomandibular joint magnetic resonance imaging scans were obtained from all subjects. Joints were classified as normal or having disc displacement. Asymptomatic volunteers had 28 (25%) joints with disc displacement; 10 (18%) had unilateral and 9 (16%) had bilateral disc displacement. Of the TMD patients, 25 (13.8%) had bilateral symptomatic but normal joints. Fifty-one (28.2%) had unilateral and 105 (58%) had bilateral disc displacement. Odds ratios (12.2 [95% confidence interval = 6.1 to 24.4, P = .001]) suggest a strong association between disc displacement and TMD. This study suggests that disc displacement is relatively common (34%) in asymptomatic volunteers and is highly associated with patients (86%) with TMD.

Adolescent↗

Immediate partial denture with a cast metal framework. A 6-year evaluation.

The use of dentures immediately after tooth removal is a common practice in dentistry especially when tooth extraction causes aesthetic problems. In the field of complete dentures, the procedure for the construction of immediate dentures permits the preparation of prostheses with the characteristics of standard dentures that can be used for a long period of time, promoting the recovery of function and aesthetic appearance without impairing patient comfort. For removable partial dentures, immediate prostheses are usually provisional for use over a short period of time while the extraction site heals. These dentures are usually made with acrylic resin and wrought wires, and in addition to compressing delicate parts of the support system, often do not provide the comfort and security needed by the patient. Immediate removable partial dentures with a metal framework are seldom used for this procedure, probably because of the difficulty in fitting the framework prior to surgery. The authors present a clinical example in which a modification of framework positioning permitted previous fitting of the framework, eliminating the possibility of lack of fit after tooth extraction, which resulted in clinical success 6 years later.

Dental Casting Technique↗

Generalized joint laxity and temporomandibular disorders.

Temporomandibular disorders (TMD) has been suggested to be of multifactorial etiology. One factor that has been suggested is laxity of joint ligaments. The purpose of this study was to evaluate the relationship between generalized joint hypermobility and TMD. Thirty-eight asymptomatic volunteers and 62 symptomatic patients were included in this study. All asymptomatic volunteers did not have temporomandibular joint pain, limited jaw movement, joint sounds, or previous TMD treatment. All subjects had bilateral magnetic resonance imaging scans in the sagittal closed and opened and coronal closed positions. The Beighton test was used to score joint laxity with a laxity score of > or = 4 to define generalized joint laxity. The symptomatic group had an increase in joint laxity as compared to asymptomatic control subjects (odds ratio 4.0 [95% confidence interval = 1.38 to 10.95, P = .01]). There were no differences in laxity between male and female symptomatic subjects (P > .05). This study suggests a positive correlation between generalized joint laxity and TMD.

Adult↗