PubMed Health⌕ Search

Biomedical subjects

R F Zuk

Publications and source records attributed to R F Zuk.

9 recordsLinked to original sources

Immunoassay for urinary pyridinoline: the new marker of bone resorption.

Urinary pyridinoline (Pyd) and deoxypyridinoline (Dpd) are markers of bone resorption that are elevated above normal in subjects with metabolic bone disease. Total Pyd and Dpd, both free and peptide-bound forms, can be measured by HPLC after hydrolysis and cellulose chromatography. Since free Pyd is the major component of total Pyd in urine, we developed an immunoassay using free Pyd as an immunogen. This assay is much easier to perform than HPLC, requires no sample preparation, and correlates well with total Pyd measurement by HPLC (r = 0.97) and with urinary hydroxyproline (r = 0.90). The antiserum reacts most strongly with free Pyd and Dpd and minimally with glycosylated and large peptide-bound forms. The sensitivity of the Pyd immunoassay is less than 25 nM. The intraassay CV is 5-10%; the interassay CV is 10-15%. Analytic recovery studies indicated negligible sample interference. Furthermore, measurement of the Pyd in the same individuals over a 30 day time period exhibited minimal day-to-day variation. Thus, the Pyd immunoassay provides a rapid and easy method for evaluation of Pyd in urine. Pyd immunoassay may serve as a practical method of screening for metabolic bone disease and for monitoring therapeutic treatment.

Adult↗

Detection of antibody to the PreS2 sequence of the hepatitis B virus envelope protein using an immuno-ligand assay with a silicon sensor detection system.

Sensitive immunoassays are essential for establishing the efficacy of recombinant vaccines to hepatitis B virus (HBV). These experimental vaccines include the PreS2 and S domains of the HBV envelope protein. To facilitate measurement of antibody against HBV PreS2, we employed the immuno-ligand assay with silicon sensor-based detection. Labeling of immune reagents with the haptens biotin and fluorescein allows adaptation to the immunofiltration light addressable potentiometric sensor (LAPS) system. A biotinylated monoclonal anti-PreS2 antibody and anti-PreS2 in clinical serum samples competitively bind in liquid phase to a fluorescein labeled PreS2 + S antigen. Streptavidin mediates the immobilization on biotinylated nitrocellulose membranes. Fluorescein mediates binding of an anti-fluorescein urease conjugate to the immune complex. Urease serves as the signal-generating component which subsequently is measured in the LAPS reader. In comparison to a competitive RIA, the immuno-ligand assay demonstrated a four-fold improved sensitivity using a smaller sample volume. The higher sensitivity resulted in earlier detection of seroconversion during a clinical vaccine study.

Antibodies, Monoclonal↗

Quantitation of DNA hybridization in a silicon sensor-based system: application to PCR.

Rapid, quantitative hybridization assays with good sensitivity are needed in many applications, for example, determining the amount of specific product from PCR. We have developed an assay which relies on the hybridization of a biotinylated oligomer and a fluoresceinated oligomer to a single-stranded target in solution. The hybridized complex is captured by streptavidin to a biotinylated membrane. After capture, the hybridization complex is detected by an antifluorescein-urease conjugate which binds to the fluoresceinated probe. The membrane-bound urease conjugate is exposed to urea and assayed with a pH-sensitive silicon sensor. The total assay time is less than 2 h and the sensitivity limit is 20 x 10(6) molecules with a coefficient of variation, CV, of less than 10%. The assay was applied to the analysis of a model target using PCR. We were able to measure the amount of specific product and the amplification factor during the exponential phase of PCR. Using extrapolation from the measured amounts of amplified product, the initial amounts of target molecules were calculated to be 1.2 x 10(6) and 4.0 x 10(2) when the added quantities were 3 x 10(6) and 3 x 10(3), as determined by serial dilution.

Biotin↗

A silicon sensor-based filtration immunoassay using biotin-mediated capture.

A sensitive sandwich immunoassay for human chorionic gonadotropin (hCG) was developed with biotin-mediated filtration capture and silicon sensor detection. A high density of biotin on the membrane assured efficient capture of complexes containing streptavidin and analyte. Capture efficiency was not affected over a wide range of filtration flow rates or biotin concentrations. The assay utilized the pH sensing ability of the light addressable potentiometric sensor (LAPS) for the detection of urease-antibody conjugates. A LAPS reader was constructed which allowed the enzyme conjugate to be detected in approximately 1 microliter volumes. Effects from variations in detection volume were studied. 10 pg of hCG could be detected in an assay time of 20 min with four standard deviations separation from background. Comparison to a commercial RIA was made.

Antibodies, Monoclonal↗

Picogram quantitation of total DNA using DNA-binding proteins in a silicon sensor-based system.

We report a rapid and reproducible method to quantify total DNA at picogram levels. Two high-affinity DNA-binding proteins are used to construct a sandwich assay and a semiconductor sensor is used for quantitation. Single-stranded DNA-binding protein (SSB) from Escherichia coli is conjugated with a linker molecule, biotin, for specific capture of the DNA complex onto a membrane. Monoclonal anti-DNA antibody is conjugated with an enzyme, urease, for signal generation. To detect DNA, a sample is denatured to form single-stranded DNA and then incubated with a reagent containing both DNA-binding protein conjugates and streptavidin. After incubation of the reagent with the DNA sample for 1 h at 37 degrees C to form a complex of streptavidin--biotin--SSB--DNA--anti-DNA--urease, the mixture is filtered through a biotin-coated nitrocellulose membrane which binds the streptavidin component of the complex. The unbound reagent is washed off the membrane, and then the captured DNA complex is detected with a light-addressable potentiometric sensor which measures the pH change catalyzed by the urease in the complex. This assay can detect 2 pg of DNA with a quantitation coefficient of variation of less than 10% in the range 10 to 200 pg.

Animals↗

Sub-femtomole quantitation of proteins with Threshold, for the biopharmaceutical industry.

The Threshold system provides for rapid quantitation of a variety of analytes at sub-femtomole levels, which is fewer than 6 x 10(8) molecules. The operating principles of the measurement system will be described, including the means for chemical modulation of the signal and the subsequent signal detection utilizing a proprietary silicon sensor. The Immuno-Ligand Assay is a universal ligand-binding assay system which provides quantitative measurement of proteins (including antibodies) in a variety of biological media. Assay performance will be described, along with data demonstrating sensitivity, precision and accuracy, for a variety of analytes of interest to the biopharmaceutical industry.

Animals↗

One-step enzyme immunochromatographic assay for theophylline.

The convenience of the previously described enzyme immunochromatography method for visually quantifying theophylline in whole blood has been improved with the development of a one-step protocol. The capillary migration and color generation in the two-step enzyme immunochromatographic assay have been combined into a single step. Ascorbic acid is used as a signal inhibitor to delay enzymatic color product formation until the inhibitor itself is consumed. The concept of internal delay reaction is presented and the mechanism of ascorbate's action as an inhibitor to temporarily delay color generation is described. The internal delay reaction has been applied to a practical one-step quantitative visual enzyme immunochromatographic assay for theophylline in whole blood.

Ascorbic Acid↗

Enzyme immunochromatography--a quantitative immunoassay requiring no instrumentation.

We describe a novel test-strip immunoassay for quantifying drugs in biological fluids. This enzyme immunochromatographic ("immunograph") method combines many features of the enzyme-channeling homogeneous immunoassay with immunochromatography and capillary migration to provide a non-separation, non-instrumental assay for theophylline in which quantification is based on the spatial distribution of enzyme label rather than on the modulation of enzyme activity. Sample antigen and hapten-enzyme conjugate are combined and moved by capillary action up a paper strip on which specific antibody has been immobilized. After color development, the assay result is evaluated by measuring the height of the colored zone on the test strip. Quantification is not a function of enzyme activity, so the method is relatively insensitive to sample matrix effects, enzyme instability, temperature, and incubation timing. Either whole blood or plasma can be used as sample. Results correlate well with those by established instrumental methods. The simple, rapid (15 min), two-incubation protocol is well suited for on-site testing in non-laboratory environments.

Animals↗

Fluorescence protection immunoassay: a new homogeneous assay technique.

We describe a "fluorescence protection immunoassay," in which formation of an immune complex of a fluorescer-labeled antigen sterically protects the fluorescer from binding by antibodies to it. Competitive binding of unlabeled antigen by its antibody prevents formation of the fluorescer-labeled antigen immune complex, and allows anti-fluorescein to quench the fluorescence by binding to the fluorescer. This phenomenon is the basis of a new homogeneous assay technique that requires no separation step. The steric exclusion of anti-fluorescein from fluorescein-labeled human IgG immune complexes was altered by changing the molecular dimensions ob both antifluorescein and the immune complex. The assay did not require highly purified fluorescein-labeled human IgG. An assay is demonstrated in which was used a fluorescein-labeled human IgG conjugate containing IgG that was only 10% pure. Measurement of IgG in human serum samples correlated well with results by radial immunodiffusion. The method is applicable to the assay of both proteins and analytes of low molecular mass.

Antigen-Antibody Complex↗