PubMed Health⌕ Search

Biomedical subjects

R Felix

Publications and source records attributed to R Felix.

At least 37 records · Page 2Linked to original sources

Comparison of CT, MRI and FDG-PET in response prediction of patients with locally advanced rectal cancer after multimodal preoperative therapy: is there a benefit in using functional imaging?

The aim of this study was to compare CT, MRI and FDG-PET in the prediction of outcome of neoadjuvant radiochemotherapy in patients with locally advanced primary rectal cancer. A total of 23 patients with T3/4 rectal cancer underwent a preoperative radiochemotherapy combined with regional hyperthermia. Staging was performed using four-slice CT (n=23), 1.5-T MRI (n=10), and (18)F-FDG-PET (n=23) before and 2-4 weeks after completion of neoadjuvant treatment. Response criteria were a change in T category and tumour volume for CT and MRI and a change in glucose uptake (standard uptake value) within the tumour for FDG-PET. Imaging results were compared with those of pretherapy endorectal ultrasound and histopathological findings. Histopathology showed a response to neoadjuvant therapy in 13 patients whereas 10 patients were classified as nonresponders. The mean SUV reduction in responders (60+/-14%) was significantly higher than in nonresponders (37+/-31%; P=0.030). The sensitivity and specificity of FDG-PET in identifying response was 100% (CT 54%, MRI 71%) and 60% (CT 80%, MRT 67%). Positive and negative predictive values were 77% (CT 78%, MRI 83%) and 100% (CT 57%, MRI 50%) (PET P=0.002, CT P=0.197, MRI P=0.500). These results suggest that FDG-PET is superior to CT and MRI in predicting response to preoperative multimodal treatment of locally advanced primary rectal cancer.

Adenocarcinoma↗

Myocardial viability assessment in patients with highly impaired left ventricular function: comparison of delayed enhancement, dobutamine stress MRI, end-diastolic wall thickness, and TI201-SPECT with functional recovery after revascularization.

This study compared different magnetic resonance imaging (MRI) methods with Tl(201) single photon emission computerized tomography (SPECT) and the "gold standard" for viability assessment, functional recovery after coronary artery bypass grafting (CABG). Twenty patients (64+/-7.3 years) with severely impaired left ventricular function (ejection fraction [EF] 28.6+/-8.7%) underwent MRI and SPECT before and 6 months after CABG. Wall-motion abnormalities were assessed by stress cine MRI using low-dose dobutamine. A segment with a nonreversible defect in Tl(201)-SPECT and a delayed enhancement (DE) in an area >50% of the entire segment, as well as an end-diastolic wall thickness <6 mm, was defined as nonviable. The mean postoperative EF (n=20) improved slightly from 28.6+/-8.7% to 32.2+/-12.4% (not significant). Using the Tl(201)-SPECT as the reference method, end-diastolic wall thickness, MRI-DE, and stress MRI showed high sensitivity of 94%, 93%, and 84%, respectively, but low specificities. Using the recovery of contractile function 6 months after CABG as the gold standard, MRI-DE showed an even higher sensitivity of 99%, end-diastolic wall thickness 96%, stress MRI 88%, and Tl(201)-SPECT 86%. MRI-DE showed advantages compared with the widely used Tl(201)-SPECT and all other MRI methods for predicting myocardial recovery after CABG.

Aged↗

Imaging of dopamine transporters and D2 receptors in vascular parkinsonism: a report of four cases.

The role of nuclear medicine imaging in the diagnosis of vascular parkinsonism (VP) has been addressed by only few studies up to now. Most previous reports suggest no or only mild impairment of DAT and D2 receptors in VP. In contrast, in four patients with VP, reported here, the combined DAT and D2 receptor SPECT showed highly unusual changes in the pre- and/or postsynaptic dopaminergic system. The possible value of combined DAT/D2 receptor SPECT imaging should be investigated by future prospective studies.

Aged↗

[Ultrasound contrast agents for liver diagnostics].

Ultrasound contrast agents have achieved a high level of acceptance in diagnostics of liver tumors. Contrast-enhanced ultrasound can, on the one hand, be used for detection of liver tumors, e.g., during the search for metastases in tumor staging, and, on the other hand, for tumor characterization. The dispersion behavior of the ultrasound contrast agent plays a decisive role in the characterization and the enhancement patterns correspond to a large extent to those already known from contrast-enhanced computed tomography. Contrast-enhanced ultrasound can also be employed for monitoring ablative tumor therapies, visualization of vessels difficult to depict, and measurement of the so-called liver transit time.

Contrast Media↗

[Appearance of orbital diseases on MRI].

We provide an overview of diseases of the orbit and their MR imaging appearance. Over recent years MRI has become established in the diagnosis of orbit diseases. There is a selection of different surface coils for examination. The choice of surface coil depends on the clinical question and the anatomical region under consideration. In addition, the significance of the different sequences and the value of contrast medium administration are discussed.

Contrast Media↗

Portal vein thrombosis: etiology, diagnostic strategy, therapy and management.

Myeloproliferative disorder, liver cirrhosis with portal hypertension, deficiency of natural anticoagulant proteins, gene mutation and hepatocellular carcinoma are the most frequent causes of portal vein thrombosis (PVT). Higher accuracy of the diagnostic methods is the reason why today the cause of PVT can be found more frequently. With imaging methods, PVT with or without cavernous transformation can be diagnosed. Fresh thrombus can be undetected in sonography due to the low echogenity but can be recognized in color Doppler sonography, especially with contrast-enhancing agent. Contrast-enhanced 3D MR angiography allows a comparable accuracy in the detection of PVT as digital subtraction angiography. Therapeutical options of PVT consist of mechanical recanalization of the portal vein, local fibrinolysis with or without placement of transjugular intrahepatic portosystemic stent shunt (TIPS), combination of mechanical recanalization and local fibrinolysis, systemic thrombolytic therapy, anticoagulation alone and surgical thrombectomy. Once PVT is found in sonography, Doppler sonography may be performed in order to distinguish benign from malignant thrombus. If further information is needed, MR angiography or contrast enhanced CT is the next step. If these tests are unsatisfactory, digital subtraction angiography should be performed. Until the early nineties, shunt surgery was recommended in patients with PVT who bled despite endoscopic treatment. Today, in symptomatic noncavernomatous PVT, recanalization with local methods is recommended. Additional implantation of TIPS should be performed when the patient is cirrhotic. In recent PVT in non-cirrhotic patients anticoagulation alone is recommended. It is expected that in old PVT anticoagulation can prevent further extension of the thrombus.

Animals↗

[Potential advantages of the MRI for the radiofrequency ablation of liver tumors].

PURPOSE: To present first results of radiofrequency ablation of liver tumors using a new MR compatible applicator. MATERIALS AND METHODS: We performed 37 interventions in 20 patients (mean age 58.6 years) with primary intrahepatic malignancies or metastases: colorectal carcinoma n = 6, hepatocellular carcinoma n = 3, pancreatic carcinoma n = 4, sarcoma n = 2, cholangiocellular carcinoma n = 1, carcinoma of the tonsil n = 1, breast carcinoma n = 1, gastric carcinoma n = 1, and gastrointestinal stroma tumor n = 1. Interventions were performed under CT-guidance with CT fluoroscopy (n = 32) and under MR-guidance (n = 5) using fast T1-weighted sequences in breath-hold technique. RFA was performed with the RF-generator (150 W) under local anesthesia and sedation using MR compatible applicators (Starburst XL, Rita Medical Systems, USA) together with the appropriate Soft Tissue Introducer System. Intra-interventional control was performed with intrahepatically or intralesionally placed introducer system or applicator. MRI was performed with plain breath-triggered T2-weighted turbo spin echo sequences (TSE T2) with fat saturation. RESULTS: All interventions were performed without major events. The mean diameter of induced coagulation was 4.0 (+/- 0.7) cm. Repositioning was necessary in 8 interventions (21 %) after detection of residual tumor on an intra-interventional MRI. After a mean follow-up of 6.5 (+/- 1.2) months, the local tumor control rate was 92 %. CONCLUSION: MR-compatible RF applicators offer the opportunity for intra-interventional detection of residual tumor during RF ablations by use of sensitive MRI sequences. These procedures may lead to a higher confidence in tumour ablation and may reduce the number of re-interventions and local recurrences of intrahepatic tumors.

Catheter Ablation↗

[Comparison of radiation dose and image quality of Siremobil-IsoC(3D) with a 16-slice spiral CT for diagnosis and intervention in the human pelvic bone].

PURPOSE: To compare the image quality of 16-slice computed tomography with the image quality of Siremobil-IsoC (3D) of the pelvic region and to measure simultaneously the radiation dose before and after implantation of a sacroiliac screw (SI-screw) MATERIALS AND METHODS: The pelvic region of 8 human cadavers was examined in the Siremobil-IsoC (3D) at five different levels. We used a standard protocol for the 16-slice CT of the complete pelvic region before and after insertion of a pelvic screw, followed by stepwise reduction of the tube current to find the tube current that equalizes the image quality of both modalities. We controlled the image quality by judging important structures such as neuroforamen, nerves, sacroiliacal joint space, intervertebral space, osteophytes, iliopsoas muscle, acetabular surface, fovea centralis, hip joint and os pubis. The image quality was judged by three radiologists and three trauma surgeons using a ranking from 1 to 5. The dose was measured with an endorectally placed NOMEX Dosimeter, to obtain the gonadal dose. RESULTS: The medium score for all viewers of the Siremobil-IsoC (3D) examinations was between 3 and 4.3. The medium score for all CT-examinations with a tube current of 250 mA was between 1.3 and 2.2. The reduction of tube current down to 80 mA hardly influenced the marks for the analyzed structures. Under 80 mA, bony structures, even after implantation of a SI-screw, were still marked as good, but soft tissue differentiation was getting worse. For the examination of the pelvis, the average dose-length product for the IsoC (3D) was 41.2 mGy x cm. The medium dose-length product for CT was 389 mGy x cm for 250 mA, 125 mGy x cm for 80 mA and 82 mGy x cm for 60 mA. CONCLUSION: The Siremobil-IsoC (3D) is sufficient for therapeutic intraoperative purpose, but the image quality is not sufficient for diagnostic purpose. The higher dose-length product of a CT examination is justifiable because of a better overview, shorter examination time and qualitative superiority. An advantage of the Siremobil-IsoC (3D) is the intraoperative availability with acceptable 3D image quality compared to conventional fluoroscopy.

Bone Screws↗

[Morphometric analysis of the temporomandibular joint with MRI in 320 joints].

PURPOSE: To compare several morphometric parameters in MRI with the functional status of the articular disc in a large patient group suffering from internal derangement (ID) of the temporomandibular joint (TMJ). MATERIALS AND METHODS: In a retrospective study, 320 analyzable high resolution MRI examinations of the TMJs obtained in a 1.5 T unit were evaluated in 184 patients with clinically suspected ID. The analysis included the anatomical structures and a number of morphometric parameters previously described in the literature. The parameters were compared with the position of the articular disc. RESULTS: The disc position was categorized as "normal" (NDP, 21.9 %, n = 70), "anterior displacement with reduction on opening" (AMR, 51.6 %, n = 165) and "anterior displacement without reduction on opening" (AOR, 26.6 %, n = 85). With increasing disc displacement, significant configurational changes of the disc were observed. Disc displacement was associated with changes of the condyle consisting of increasing deformity and other degenerative changes. A large tuberculum and marked inclination of the eminence can be seen as predisposition for the development of ID. With increasing severity of the ID, the position of the condyle moved from a centric position of the condylar center to an excentric (dorsal and cranial) position. CONCLUSION: MRI demonstrated that increasing disc displacement is associated with changes of the disc, condyles and condylar position in the fossa.

Cartilage, Articular↗

[Diagnostic value of MR analysis of cartilaginous lesions compared with intraoperative arthroscopy in calcaneal fractures].

PURPOSE: To determine the diagnostic value of MRI in preoperative analysis and classification of cartilaginous lesions - especially of the posterior facet - in traumatic calcaneal fractures compared with intraoperative arthroscopy. MATERIALS AND METHODS: Twenty-four consecutive patients with traumatic calcaneal fractures underwent prospective MRI of the subtalar joint surface using T1- and T2-weighted spin echo sequences and fat suppressed 3D gradient echo sequences in semicoronal slice orientation (1.5 T MRI). After randomization, the images were analyzed by two blinded and independent readers experienced in MRI. The results were compared with the intraoperative arthroscopic findings as to location and depth of the defects using the Outerbridge classification. RESULTS: We examined 12 calcaneal fractures of type 2, 8 of type 3 and 4 of type 4 according to the Sanders classification. With respect to principal detection and exact classification, 67 of 96 (69.8 %) of all arthroscopic verified cartilaginous defects were diagnosed correctly by MRI. Disregarding the degree of the defects, 38 of 44 (86.4 %) chondral lesions were detected (sensitivity: 86.4 %, specificity: 86.5 %, diagnostic accuracy: 86.5 %). Considering the chondral lesions of degrees 3 and 4 together, the sensitivity was 86.0 %, the specificity 86.8 %, and the diagnostic accuracy 86.5 % . Assessing these degrees separately, the sensitivity was only 33.3 % for degree 3 and 58.1 % for degree 4, whereas the specificity was definitely higher with 82.1 % for degree 3 and 89.2 % for degree 4. CONCLUSION: The MR detection of cartilaginous defects in calcaneal fractures has a sufficient diagnostic accuracy for planning the surgical intervention and assessing the long-term postsurgical prognosis.

Adult↗

[Detection of airways stenoses: comparison of virtual and flexible bronchoscopy].

PURPOSE: To compare virtual with flexible bronchoscopy for the detection of bronchial stenoses. MATERIALS AND METHODS: In a retrospective study, we compared the results of 26 patients, who had clinical suspected pathologies of the tracheobronchial airways and underwent both flexible bronchoscopy and multislice CT with 3D surface rendering of the airways. Flexible bronchoscopy and virtual bronchoscopy were compared as to the rate of detecting bronchial stenoses. For statistical analysis, we divided the tracheobronchial tree in the following sections: trachea, 2 main bronchi, 6 lobar bronchi, 18 segmental bronchi and 36 subsegmental bronchi, corresponding to 63 bronchial sections for each patient (on average) and a total of 1638 bronchial sections for all 26 patients. We graded the bronchial stenosis as less than 50 %, as 50 to 95 % and as complete obstruction. RESULTS: Virtual bronchoscopy detected 25 bronchial stenoses, while flexible bronchoscopy only revealed 17 stenoses. Stenoses with a diameter less than 50 % were found with virtual bronchoscopy 14 times and with flexible bronchoscopy 10 times. Stenoses with a diameter between 50 and 95 % were detected 7 and 4 times, respectively, and complete obstructions 4 and 3 times, respectively. Tracheobronchial stenoses were well recognized with virtual bronchoscopy. Moreover, the virtual method enabled the visualization of high-grade stenoses and post-stenotic areas that could not be passed by the fiberoptic bronchoscope. Virtual bronchoscopy detected stenoses at a higher rate but the difference was not statistically significant (stenoses < 50 %: p = 0.352, 50 - 95 %: p = 0.339, complete obstruction: p = 0.696). CONCLUSION: Virtual bronchoscopy is a useful non-invasive method for the diagnostic evaluation of the tracheobronchial tree. In comparison with flexible bronchoscopy, virtual bronchoscopy is superior in revealing high-grade stenoses and visualizing post-stenotic areas.

Adult↗

[The effect of the field strength on standardized MRI of the brain to demonstrate cranial nerves and vessels: a comparison of 1.5 and 3.0 Tesla].

PURPOSE: Comparison of MR images acquired as routine examinations at a field strength of 3.0 T and 1.5 T to determine whether and to which degree the image quality improves at the higher field strength of 3.0 T. MATERIALS AND METHODS: Routine MR images of 200 patients were examined retrospectively, with 100 images obtained at 1.5 T and 100 obtained at 3.0 T. The examinations were performed with a quadrature head coil and focused on the basal cisterns because of the abundance of small distinct structures in this region. We selected the T2-weighted 2D-FSE sequence in transverse direction for comparison. At both field strengths, the same section thickness of 5 mm and a matrix of 512 x 388 (FOV: 220 mm) were used. The quality of the images was evaluated with regard to depicting the cranial nerves N. III, V - X, the AICA and PICA. For comparison, image quality was rated with a score from 1 (well defined) to 5 (not depicted). RESULTS: A score of 1 was obtained in 46 % of the anatomic structures examined at 3.0 T and in only 9.2 % at 1.5 T. A score of 2 was given in 27.6 % of the anatomic structures at 3.0 T vs. 23.5 % at 1.5 T, a score of 3 in 17.2 % vs. 28.1 %, a score of 4 in 8.6 % vs. 28.7 %, and a score of 5 in 0.4 % vs. 10.3 %, respectively. The Mann-Whitney U test showed significance at p < 0.001 for the comparison of images at 1.5 and 3.0 Tesla. CONCLUSION: Routine magnetic resonance imaging using the same quadrature coil technique and similar acquisition times at 3.0 T and 1.5 T shows an improvement for T2-weighted images at the higher field strength.

Adolescent↗

[CT-guided resection of pulmonary metastases].

PURPOSE: To evaluate the feasibility and potential use of intraoperative computed tomography (IOP CT) as guidance for video-assisted thoracic surgery (VATS). MATERIAL AND METHODS: Fifteen consecutive patients with peripheral intrapulmonary nodules underwent a thoracoscopy with IOP CT. Solitary lesions were known in 6/15 patients (40 %, group II) whereas 9/15 (60 %, group I) patients had multiple lesions (n >/= 2). IOP CT was performed with the mobile CT scanner Philips Tomoscan M. Radiologists intraoperatively placed percutaneous marks of lung lesions after unsuccessful VATS by use of a lung marker set (Somatex, Teltow, Germany). VATS was performed under general anaesthesia and with double lumen endotracheal intubation for single lung ventilation. Imaging quality and imaging of pulmonary nodules were rated. RESULTS: IOP CT was evaluated as feasible combined with VATS. Thoracotomy was avoided in 5/15 patients where lesions could not be detected by VATS. A CT-guided biopsy was performed in two patients after an unsuccessful attempt of thoracoscopy. There were no documented side effects. CONCLUSION: First clinical results suggest that a combination of VATS and IOP CT is feasible. Thus, the number of open thoracoscopies might be decreased. Intrapulmonary lesions not detectable with VATS could be marked under CT -- guidance intraoperatively and then resected by thoracoscopy.

Aged↗

[Computed tomographic criteria as expected effect to inhaled nitric oxide in patients with severe acute respiratory distress syndrome].

PURPOSE: Inhaled nitric oxide (iNO) is an effective therapy for severe hypoxemia in most patients with acute respiratory distress syndrome (ARDS). For unknown reason, a subset of ARDS patients does not respond favorably to iNO therapy. We hypothesized that radiological manifestation of lung injury may be related to iNO response. MATERIALS AND METHODS: We retrospectively analyzed data from n = 25 ARDS patients who received iNO, and underwent chest CT within 72 h prior to inhaled treatment. The morphology of coherently pathologic lung tissue was characterized by the length of the borderline between consolidated, infiltrated and atelectatic lung tissue and radiologically normal lung tissue. This quantity was expressed as relative fraction of the visceral pleural circumference and averaged over all CT slices. Furthermore we semiquantitatively determined the total volume of consolidated lung tissue as part of the whole lung. RESULTS: In n = 6 non-responders to iNO (DeltaPaO2 < 10 %), we determined a short relative borderline between normal and consolidated lung tissue due to the presence of large and coherently consolidated lung regions. In n = 19 iNO responders (DeltaPaO2 > 10 %), we found significantly less coherently consolidated lung tissue evidenced by an increased relative borderline when compared to iNO non-responders (0.09 +/- 0.02 vs. 0.1 +/- 0.01; P < 0.05). Moreover, there was a moderate and significant correlation between DeltaPaO2 induced by iNO and the relative borderline in all patients studied (R = 0.59; P < 0.05). Total fraction of consolidated lung tissue volume was not different between iNO non-responders and responders (60 +/- 3 % vs. 54 +/- 2 % n. s.). CONCLUSION: Our data demonstrate that the gross morphological distribution of pathological lung tissue influences iNO response in ARDS. Inhaled NO was most beneficial in injured lungs characterized by many small consolidated areas surrounded by normal lung tissue. The increased borderline between pathologic and normal lung tissue offers additional possibility for iNO to divert blood flow from shunt areas to ventilated lung regions, which consequently improves arterial oxygenation.

Adult↗

[Combination of dynamic MR enteroclysis (Sellink) and MR colonography to diagnose Crohn's disease].

PURPOSE: To investigate whether a combined examination with MRI enteroclysis and MRI colonography is practicable and would provide additional findings in the regions seen with ileo-colonoscopy in the work-up of patients with Crohn's disease. MATERIAL AND METHODS: Twenty-five consecutive patients with Crohn's disease (CD) (age range 19 to 42 years, mean age 29.2 years, gender ratio male:female 8:17) were retrospectively studied. All patients underwent conventional ileo-colonoscopy as a standard of reference followed by a combined examination of MRI enteroclysis and MRI colonography at 1.5T within 15 days. Two blinded radiologists evaluated the MRI examinations and compared them with the colonoscopic results. RESULTS: The MRI examination detected 31 inflamed bowel segments in 25 patients. In comparison to colonoscopy, 5 additional, endoscopically inaccessible lesions were found by MRI and only 2 lesions were missed by MRI. Compared to colonoscopy, MRI found 7 of 10 fistulas detected by colonoscopy, and 3 otherwise indiscernible abscesses. The detection of inflamed bowel segments by means of MRI (endoscopy) revealed a sensitivity of 88.8 % (100 %), specificity of 80 % (100 %) and an overall accuracy of 96 % (100 %). CONCLUSION: This study provides strong evidence that the combination of MRI enteroclysis and MRI colonography is practicable and supplies additional results regarding the regions which are not seen with ileo-colonoscopy in the work-up of patients with Crohn's disease.

Adult↗

[Contrast media pressure injection using a portal catheter system--results of an in vitro study].

PURPOSE: Are implanted central venous port catheters suitable for contrast media pressure (power) injection in computed tomography? MATERIAL AND METHODS: In an in vitro study 100 ml of contrast medium (Ultravist 370, Schering, Berlin, Deutschland) was injected through 20 different port catheter systems using a power injector (Stellant, Medrad, Inianola, USA) with a pressure limit of 325 PSI. The injection rate was increased from 2 ml/s to 10 ml/s in increments of 2 ml/s. The maximum injection pressure and maximum injection rate were assessed. RESULTS: An injection rate of 2 ml/s was possible in all catheter systems. Injection rates of 4 ml/s in 18 systems, 6 ml/s in 13 systems and 8 ml/s in 6 systems were achieved. With a given pressure limit of 325 PSI an injection rate of 10 ml/s was not possible in any of the port catheter systems. There were no catheter ruptures, catheter disconnections or contrast extravasations noted. CONCLUSION: Power injection of contrast media with a pressure limit of 325 PSI seems to be tolerated by port catheter systems. Most of the evaluated port systems allow flow rates suitable for multislice computed tomography requiring rapid contrast injection.

Catheterization, Central Venous↗

Methods and potentials of magnetic resonance imaging for monitoring radiofrequency hyperthermia in a hybrid system.

INTRODUCTION: Non-invasive thermometry (NIT) is a valuable and probably indispensable tool for further development of radiofrequency (RF) hyperthermia. A hybridization of an MRI scanner with a hyperthermia system is necessary for a real-time NIT. The selection of the best thermographic method is difficult, because many parameters and attributes have to be considered. METHODS: In the hybrid system (Siemens Symphony/BSD-2000-3D) the standard methods for NIT were tested such as T1, diffusion (ADC: apparent diffusion coefficient) and proton-resonance-frequency shift (PFS) method. A series of three-dimensional datasets was acquired with different gradient-echo sequences, diffusion-weighted EPI spin-echo sequences and calculated MR-temperatures in the software platform AMIRA-HyperPlan. In particular for the PFS-method, corrective methods were developed and tested with respect to drift and other disturbances. Experiments were performed in phantoms and the results compared with direct temperature measurements. Then the procedures were transferred to clinical applications in patients with larger tumours of the lower extremity or the pelvis. RESULTS: Heating experiments and MR-thermography in a homogeneous cylindrical phantom give an excellent survey over the potentials of the methods. Under clinical conditions all these methods have difficulties due to motion, physiological changes, inhomogeneous composition and susceptibility variations in human tissues. The PFS-method is most stable in patients yielding reasonable MR temperature distributions and time curves for pelvic and lower extremity tumours over realistic treatment times of 60-90 min. Pooled data exist for rectal tumour recurrencies and soft tissue sarcomas. The fat tissue can be used for drift correction in these patients. T1 and diffusion-dependent methods appear less suitable for these patients. The standard methods have different sensitivities with respect to the various error sources. The advantages and pitfalls of every method are discussed with respect to the literature and illustrated by the phantom and patient measurements. CONCLUSIONS: MR-controlled RF hyperthermia in a hybrid system is well established in phantoms and already feasible for patients in the pelvic and lower extremity region. Under optimal conditions the temperature accuracy might be in the range of 0.5 degrees C. However a variety of developments, especially sequences and post-processing modules, are still required for the clinical routine.

Humans↗

Magnetic resonance imaging of hyaline cartilage defects at 1.5T and 3.0T: comparison of medium T2-weighted fast spin echo, T1-weighted two-dimensional and three-dimensional gradient echo pulse sequences.

PURPOSE: To evaluate and compare the diagnostic accuracy of appropriate magnetic resonance (MR) sequences in the detection of cartilage lesions at 1.5T and 3.0T. MATERIAL AND METHODS: Twelve chondral defects of varying depths, widths, and locations were created in the retropatellar hyaline cartilage in six sheep cadaver limbs. Axial images employing three fat-suppressed imaging sequences--(1) a T2-weighted fast spin-echo (FSE) sequence, (2) a two-dimensional (2D) and (3) three-dimensional (3D) gradient-echo (GE) sequence at 1.5T and 3.0T using an extremity quadrature coil--were evaluated by three experienced radiologists. Statistical analysis of the results consisted of receiver operating characteristics (ROC) and significant testing using the bivariate chi-square test. In addition, signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were evaluated with significance testing using the Wilcoxon test. RESULTS: The 3D GE sequence compared favorably with other sequences at 3.0T and 1.5T (Az=0.88 at 3.0T and Az=0.85 at 1.5T) missing only one small grade 2 lesion. 2D GE imaging was inferior to 3D imaging at both field strengths (P<0.05) in general. However, compared to 1.5T, lesion detectability was improved at the higher magnetic field of 3.0T (Az=0.81 and 0.73 at 3.0T and 1.5T, respectively). FSE images showed significantly inferior sensitivity and less anatomical detail compared to the GE sequences at both field strengths (Az=0.64 and 0.72 at 3.0T and 1.5T, respectively; P<0.05). However, compared to 1.5T, lesion detectability SNR and CNR values were superior in all sequences tested at 3.0T. CONCLUSION: MRI at 3.0T improves SNR and CNR significantly in the most common sequences for cartilage MRI, resulting in an improvement in chondral lesion detection. GE imaging therefore allows resolution to be increased in an acceptable time manner for patient comfort, and the 3D GE fat-suppressed sequence at 3.0T appears to be best suited for cartilage imaging in a clinical setting.

Animals↗