PubMed HealthSearch

Biomedical subjects

R Flowers

Publications and source records attributed to R Flowers.

4 recordsLinked to original sources

Transfer factor (diffusing capacity) standardized for alveolar volume: validation, reference values and applications of a new linear model to replace KCO (TL/VA)

Transfer factor (TL) varies with alveolar volume (VA), but not in the manner implied by the carbon monoxide transfer coefficient (KCO (TL/VA)). This paper considers two other simple models (one linear and one exponential) which might standardize TL for VA, and asks the questions: 1) Is either model valid? 2) What are appropriate reference values? and 3) Will the model be useful? The relationship of TL to VA within subjects at different depths of inspiration, and between subjects having lungs of different sizes, were measured and compared. The subjects were asymptomatic, nonsmoking, Caucasian adults, including 31 males assessed in the laboratory and 503 male and female participants in population studies. The linear partial regression coefficients of TL on VA (L corrected for body temperature, atmospheric pressure and water saturation (BTPS)) standardized for height (H) in metres, were similar within- and between-subjects; the coefficients applied over a wide range of values for VA. This was not the case for the exponential model. The resulting reference equations in SI units for males and females were: TL = 11.52 H + 2.72 VA.H-2 - 0.051 Age -12.35. RSD 1.17; and TL = 4.87 H + 2.29 VA.H-2 - 0.019 Age -3.03. RSD 0.92, respectively. The residual standard deviations (RSD) about the new relationships were less than in other series. The new linear model could account for much of the variation between different published reference values for TL; it could be useful clinically, in circumstances when VA deviates from the norm. The model does not explain differences in TL associated with gender. Inclusion of VA.H-2 as a covariate in the reference equation for transfer factor, in addition to age and height, improves the accuracy of prediction of normal transfer factor compared with current reference values; its use suggests that some of the differences between published values is due to the volume term. The equations can be used clinically, and eliminate the need for carbon monoxide transfer coefficient.

Adult

Recovery of Salmonella species from nonfat dry milk rehydrated under rapid and reduced pre-enrichment conditions: collaborative study.

A collaborative study was conducted to compare the relative efficiency of the AOAC rapid rehydration method with the reduced rehydration soak method for the recovery of Salmonella species from nonfat dry milk (NFDM). In the AOAC method, a 25 g sample of NFDM is rapidly rehydrated at a 1:9 sample/water ratio and mixed by swirling. After 60 min, the flask contents are adjusted to a pH of 6.8, and 0.45 mL of 1% aqueous brilliant green dye solution is added. The flasks are then incubated at 35 degrees C. In the soak method, a 25 g sample of NFDM is gently added to the sterile brilliant green (BG) water at a 1:9 sample/BG water ratio and allowed to soak undisturbed for 60 min at room temperature before incubation. Twelve collaborators analyzed 3 shipments of samples with the following results for the AOAC and soak methods: shipment 1-31 and 46 positive samples, respectively, with a 48% increase in detection by the soak method; shipment 3-45 and 66 positive samples, respectively, with a 47% increase in detection by the soak method; shipment 2--no significant difference in recovery of Salmonella species by the 2 methods. It is recommended that the official final action method for the detection of Salmonella species, 46.054-46.067, be revised to use the soak method for the analysis of nonfat dry milk.

Animals