Ventricular cross stimulation using a pacing system analyzer.

Cross stimulation refers to the situation in which a pacing lead positioned in one cardiac chambers results in stimulation of another chamber. We report three cases of ventricular cross stimulation observed at the time of pacing system implantation. The cross stimulation occurred through bipolar atrial and ventricular leads connected in bipolar configuration to a dual chamber pacing systems analyzer. Analysis of events during cross stimulation indicated that the current pathway was occurring within the pacing system analyzer itself, due to low resistance internal connections between the ring electrodes of the atrial and ventricular pacing systems analyzer channels. Cross stimulation within the pacing system analyzer can be eliminated by making the ventricular channel unipolar. Awareness of the phenomenon reported here should assist in the avoidance of the mistaken diagnosis of pacing lead migration and malposition during pacing system implant procedures.

Aged

Short-duration, high-dose urokinase infusion for recanalization of occluded saphenous aortocoronary bypass grafts.

Thrombolytic recanalization of arterial bypass grafts has been pursued aggressively in the peripheral circulation but not in the coronary circulation. In an attempt to apply peripheral transcatheter thrombolytic techniques to the coronary circulation, nine patients with 10 occluded saphenous aortocoronary bypass grafts underwent recanalization procedures using a short-duration, high-dose urokinase infusion. Urokinase was infused at the occluded graft orifice at a rate of 600 units/min. The average infusion time was 1 hr, 26 min. The average urokinase dose was 435,000 units. Graft recanalization was achieved in eight (80%) of 10 grafts, although only six (60%) of 10 grafts were widely patent at the end of the procedure. All successfully recanalized grafts required balloon angioplasty of underlying stenoses. No complications, specifically myocardial infarction or cerebrovascular accident, were encountered. We have shown that occluded aortocoronary bypass grafts can be recanalized successfully by using a short-duration, high-dose urokinase infusion. It appears that, with attention given to angiographic techniques that minimize clot manipulation, recanalization can be accomplished safely in a majority of cases.

Adult