R Frayne

Publications and source records attributed to R Frayne.

At least 19 recordsLinked to original sources

Is correction necessary when clinically determining quantitative cerebral perfusion parameters from multi-slice dynamic susceptibility contrast MR studies?

Several groups have modified the standard singular value decomposition (SVD) algorithm to produce delay-insensitive cerebral blood flow (CBF) estimates from dynamic susceptibility contrast (DSC) perfusion studies. However, new dependences of CBF estimates on bolus arrival times and slice position in multi-slice studies have been recently recognized. These conflicting findings can be reconciled by accounting for several experimental and algorithmic factors. Using simulation and clinical studies, the non-simultaneous measurement of arterial and tissue concentration curves (relative slice position) in a multi-slice study is shown to affect time-related perfusion parameters, e.g. arterial-tissue-delay measurements. However, the current clinical impact of relative slice position on amplitude-related perfusion parameters, e.g. CBF, can be expected to be small unless any of the following conditions are present individually or in combination: (a) high concentration curve signal-to-noise ratios, (b) small tissue mean transit times, (c) narrow arterial input functions or (d) low temporal resolution of the DSC image sequence. Recent improvements in magnetic resonance (MR) technology can easily be expected to lead to scenarios where these effects become increasingly important sources of inaccuracy for all perfusion parameter estimates. We show that using Fourier interpolated (high temporal resolution) residue functions reduces the systematic error of the perfusion parameters obtained from multi-slice studies.

Brain↗

Interactive continuously moving table (iCMT) large field-of-view real-time MRI.

Continuously moving table (CMT) MRI is a new method that is capable of generating 3D, seamless, large field-of-view (FOV) images by acquiring readouts along the patient superior-inferior axis as the subject is translated through the scanner. For applications that require artifact-free images, such as arterial-phase contrast-enhanced (CE) angiography of the legs, a major challenge is to match the MR data acquisition and patient table motion with the dynamics of blood flow in the region of interest (ROI). Instead of restricting the CMT to predetermined constant table speeds, we adopted a more general approach in which the table motion is decoupled from the phase-encoding order. In our approach the table moves adaptively and in response to operator-provided feedback obtained from viewing real-time preview (or fluoroscopic) images. This interactivity is accomplished by integrating high temporal-spatial resolution encoding of the table position with real-time hybrid-space filling and image reconstruction. Experimental results obtained using our prototype interactive CMT (iCMT) system on a peripheral vascular phantom and five healthy volunteers demonstrate the feasibility of this robust and rapid imaging method for acquiring 3D large-FOV continuous images with patient-specific adaptive table motion profiles.

Beds↗

Imaging of the brain in acute ischaemic stroke: comparison of computed tomography and magnetic resonance diffusion-weighted imaging.

BACKGROUND AND OBJECTIVES: Controversy exists about the optimal imaging technique in acute stroke. It was hypothesised that CT is comparable with DWI, when both are read systematically using quantitative scoring. METHODS: Ischaemic stroke patients who had CT within six hours and DWI within seven hours of onset were included. Five readers used a quantitative scoring system (ASPECTS) to read the baseline (b) and follow up CT and DWI. Use of MRI in acute stroke was also assessed in patients treated with tissue plasminogen activator (tPA) by prospectively recording reasons for exclusion. Patients were followed clinically at three months. RESULTS: bDWI and bCT were available for 100 consecutive patients (admission median NIHSS = 9). The mean bDWI and bCT ASPECTS were positively related (p<0.001). The level of interrater agreement ranged from good to excellent across all modalities and time periods. Bland-Altman plots showed more variability between bCT and bDWI than at 24 hours. The difference between bCT and bDWI was < or =2 ASPECTS points. Of bCT scans with ASPECTS 8-10, 81% had DWI ASPECTS 8-10. Patients with bCT ASPECTS of 8-10 were 1.9 times more likely to have a favourable outcome at 90 days than those with a score of 0-7 (95% CI 1.1 to 3.1, p = 0.002). The relative likelihood of favourable outcome with a bDWI ASPECTS 8-10 was 1.4 (95% CI 1.0 to 1.9, p = 0.10). Of patients receiving tPA 45% had contraindications to urgent MRI. CONCLUSION: The differences between CT and DWI in visualising early infarction are small when using ASPECTS. CT is faster and more accessible than MRI, and therefore is the better neuroimaging modality for the treatment of acute stroke.

Aged↗

Removing the effect of SVD algorithmic artifacts present in quantitative MR perfusion studies.

Quantitative cerebral blood flow (CBF) values can be obtained from dynamic susceptibility contrast (DSC) MR perfusion studies using the standard singular value decomposition (sSVD) deconvolution algorithm. Reports in the literature from simulation and in vivo studies suggest that CBF estimates obtained using sSVD deconvolution depend on the arterial-tissue delay (ATD). By contrast, Fourier transform (FT) deconvolution produces CBF estimates that are independent of ATD. The diagnostic reliability of quantitative CBF measurements to define areas of normal tissue flow and tissue at risk is brought into doubt by such gross sensitivity to the specifics of the deconvolution approach. This variation of CBF values with ATD is shown to be an artifact associated with the current implementation of the sSVD deconvolution algorithm. A reformulated version of the SVD deconvolution algorithm (rSVD) is presented and compared to the standard SVD algorithm through simulation and patient case studies.

Algorithms↗

The probability of middle cerebral artery MRA flow signal abnormality with quantified CT ischaemic change: targets for future therapeutic studies.

OBJECTIVES: In this study we define the probability of vascular abnormality in the middle cerebral artery (MCA) territory according to the extent of ischaemic change seen using computed tomography (CT). We assessed the sensitivity and specificity of the hyperdense middle cerebral artery (HMCA) and the "dot" sign using magnetic resonance angiography (MRA). METHODS: Patients presenting with ischaemic stroke had a CT scan (<6 h) prior to MRI (<7 h). A quantitative CT scoring system (ASPECTS) was applied to CT and diffusion weighted images (DWI) at baseline and follow up (24 h) by five independent observers. The presence of HMCA and the MCA "dot" sign was also evaluated. An expert reader assessed the 3D time of flight (TOF) MRA in the anterior circulation for areas of decreased vascular signal in the MCA territory, with an absent signal taken to represent severely reduced or absent flow. RESULTS: A total of 100 consecutive patients had baseline CT and MR scans. The median NIHSS was 9. The median CT ASPECTS was 8 and equalled the median DWI ASPECTS. There were a total of 10 HMCA and 19 MCA "dot" signs, with four patients having both HMCA and "dot" signs. A total of 47 MRA flow signal abnormalities were observed in the anterior circulation. CONCLUSIONS: In the absence of accessible neurovascular imaging, the extent of CT ischaemia (ASPECTS) is a strong predictor of vascular occlusion. The CT hyperdense artery signs have a high positive predictive value but low negative predictive value.

Aged↗

Space-time relationship in continuously moving table method for large FOV peripheral contrast-enhanced magnetic resonance angiography.

Data acquisition using a continuously moving table approach is a method capable of generating large field-of-view (FOV) 3D MR angiograms. However, in order to obtain venous contamination-free contrast-enhanced (CE) MR angiograms in the lower limbs, one of the major challenges is to acquire all necessary k-space data during the restricted arterial phase of the contrast agent. Preliminary investigation on the space-time relationship of continuously acquired peripheral angiography is performed in this work. Deterministic and stochastic undersampled hybrid-space (x, k(y), k(z)) acquisitions are simulated for large FOV peripheral runoff studies. Initial results show the possibility of acquiring isotropic large FOV images of the entire peripheral vascular system. An optimal trade-off between the spatial and temporal sampling properties was found that produced a high-spatial resolution peripheral CE-MR angiogram. The deterministic sampling pattern was capable of reconstructing the global structure of the peripheral arterial tree and showed slightly better global quantitative results than stochastic patterns. Optimal stochastic sampling patterns, on the other hand, enhanced small vessels and had more favourable local quantitative results. These simulations demonstrate the complex spatial-temporal relationship when sampling large FOV peripheral runoff studies. They also suggest that more investigation is required to maximize image quality as a function of hybrid-space coverage, acquisition repetition time and sampling pattern parameters.

Algorithms↗

Symptomatic hemorrhage after alteplase therapy not due to silent ischemia.

BACKGROUND: Stroke thrombolysis-related intracerebral hemorrhage may occur remotely from the anatomical site of ischemia. One postulated mechanism for this is simultaneous multiple embolization with hemorrhage into a "silent" area of ischemia. RESULTS: A patient suffered a disabling stroke affecting the right cerebral hemisphere. He was treated with intravenous alteplase and underwent extensive early imaging with multimodal MRI. Several hours after treatment he developed a brainstem hemorrhage despite having no evidence of ischemia on DWI MRI in the brainstem. CONCLUSION: Not all occurrences of remote ICH after stroke thrombolysis are secondary to multiple emboli with silent ischemia.

Aged↗

3D MR DSA: effects of injection protocol and image masking.

The purpose of this study was to investigate the effect on three-dimensional (3D) magnetic resonance digital subtraction angiography (MR DSA) images of various injection protocol parameters (ie, injection order, volume, and rate), as well as image masking. The pelves of 10 normal volunteers were scanned using seven different contrast agent volume/injection rate combinations. Subtraction of a precontrast mask image resulted in vascular image contrast improvements of between 4.0 and 7.7 times. Image quality and smaller vessel image contrast in the masked data decreased with increasing injection number. Data acquired with a high (0.150 mmol kg(-1)) volume yielded the highest quality images, although only small nonsignificant differences in image quality and large vessel conspicuity were found between images obtained using the high and medium (0.075 mmol kg(-1)) volumes. Images acquired with a low (0. 038 mmol kg(-1)) volume, while of lower image contrast, were judged to be of reasonable quality, especially when acquired as the first or second injection. Injection rate (1 ml s(-1), 2 ml s(-1), and 4 ml s(-1)) was not found to affect the images significantly, although selection of an injection rate that gave an injection duration of approximately 10 seconds tended to give better vascular image contrast. Based on these data, a series of escalating volumes for multi-injection examination is proposed. J. Magn. Reson. Imaging 2000;12:476-487.

Adult↗

Method for rapidly determining and reconstructing the peak arterial frame from a time-resolved CE-MRA exam.

A method that determines the information necessary to reconstruct a single vascular image from a time-resolved CE-MRA exam is presented. Raw k-space data are used to approximate the time course of the contrast passage prior to image reconstruction. The resulting k-space contrast curve is used to select the data corresponding to peak arterial enhancement. These data are reconstructed and immediately presented for physician review, with the entire time-series of images available at a later time for more detailed diagnosis. This approach dramatically reduces the latency between acquisition of large 4D (3D plus time) data sets and presentation of a diagnostic quality time frame. This algorithm has proven successful in the imaging of several anatomical regions and-in exams that do not require a breath hold-permits the use of an acquisition method that produces a contrast-enhanced angiogram without a timing scan.

Arteries↗

Real-time MR imaging-guided passive catheter tracking with use of gadolinium-filled catheters.

PURPOSE: To test the hypothesis that real-time magnetic resonance (MR) imaging-guided passive catheter tracking is feasible with use of dilute gadolinium (Gd)-filled catheters, to determine the optimal Gd concentration required for tracking, and to measure catheter tip tracking accuracy. MATERIALS AND METHODS: The authors tested a real-time, T1-weighted, two-dimensional, spoiled gradient-recalled echo MR imaging sequence suitable for tracking catheters. In a yogurt phantom, the authors placed 5-F catheters filled with 2%-12% Gd solutions. MR imaging was performed with and without use of a projection dephaser that suppressed background signal. The authors measured signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and enhancement ratio to determine the optimal Gd concentration for catheter depiction. Catheter tip tracking accuracy was measured in an acrylic phantom with use of linear regression analysis, with goodness of fit assessed statistically with the F test. RESULTS: Peak catheter SNR, CNR, and enhancement ratios were obtained with 4%-6% Gd concentrations. Tip tracking accuracy was determined to be +/- 0.41 mm (R2 = 0.99; P < .0001). MR imaging reconstructions were displayed up to 3.1 frames/sec. CONCLUSIONS: Accurate MR imaging-guided passive catheter tracking was feasible in real-time with use of dilute Gd-filled catheters. This technique may have application in MR imaging-guided endovascular procedures.

Catheterization↗

MR-guided angioplasty of renal artery stenosis in a pig model: a feasibility study.

PURPOSE: To test the hypothesis that magnetic resonance (MR) imaging can guide the percutaneous treatment of renal artery stenosis in a pig model. MATERIALS AND METHODS: Ameroid constrictors were surgically placed around six renal arteries in four pigs. After 30-36 days, all stenoses were documented by conventional x-ray aortograms. MR-guided renal angioplasty was attempted for three stenoses. For these pigs, MR angiography was performed with use of contrast-enhanced three-dimensional (3D) techniques. The authors visualized catheters by filling them with dilute 4% gadolinium and imaging with two-dimensional (2D) and 3D MR fast spoiled gradient recalled echo techniques. Under MR guidance, the authors advanced a selective catheter into the affected renal artery and crossed the stenosis with a nitinol guide wire. Angioplasty was performed with a balloon catheter filled with dilute gadolinium. Stenosis and luminal diameter measurements were compared before and after angioplasty. RESULTS: After ameroid constrictor placement, four significant stenoses, one mild stenosis, and one occlusion developed. Under MR guidance, the authors achieved technical success in performing three of three (100%) attempted dilations. After MR-guided angioplasty, the mean reduction in stenosis was 35% and the mean increase in luminal diameter was 1.6 mm. CONCLUSION: Use of MR guidance for the angioplasty of renal artery stenosis in pigs is feasible.

Angioplasty, Balloon↗

Endovascular treatment of experimental canine aneurysms: feasibility with MR imaging guidance.

PURPOSE: To evaluate the feasibility of using magnetic resonance (MR) imaging to guide and monitor endovascular therapeutic procedures. MATERIALS AND METHODS: Endovascular therapeutic procedures were performed with MR imaging guidance in eight dogs by using a 1.5-T MR unit with echo-planar imaging capabilities. Carotid arterial aneurysms were surgically created in four dogs. The ability to depict, track, and position catheters, guide wires, and Guglielmi detachable coils was assessed. Catheters were first positioned with fluoroscopic guidance. Tracking and depiction were achieved with MR imaging by using commercially available catheters filled with a gadopentetate dimeglumine solution and a fast, two-dimensional, time-resolved, variable-rate k-space sampling technique. RESULTS: When either a catheter or the coaxial space between a catheter and a guide wire was filled with a solution of gadopentetate dimeglumine, catheter movement was always depicted. In the animals with aneurysms, it was possible to depict movement of a catheter into and out of the aneurysm. This was achieved by superimposing reconstructed images obtained during catheter movement onto a previously acquired MR angiogram ("road map"). Prototype Guglielmi detachable coils were successfully positioned and detached. Aneurysm obliteration was monitored with the acquisition of new road map images. CONCLUSION: The results demonstrate the feasibility of using MR imaging to guide endovascular therapeutic procedures.

Aneurysm↗

Utility of CT angiography and MR angiography for the follow-up of experimental aneurysms treated with stents or Guglielmi detachable coils.

BACKGROUND AND PURPOSE: Previous studies have depicted arterial and aneurysmal anatomy with three-dimensional time-of-flight (3D-TOF) MR angiography before and after treatment with Guglielmi detachable coils (GDCs) and with CT angiography before and after treatment with stents and stent-grafts. We investigated the ability of time-resolved contrast-enhanced 3D MR angiography (3D MR digital subtraction angiography [DSA]) to accurately depict the anatomy of experimental lateral aneurysms before and after treatment with GDCs and a variety of stents or stent-grafts, and compared these findings with 3D-TOF MR angiography without and with contrast enhancement and CT angiography. METHODS: Two nitinol stents, two nitinol-polytetrafluoroethylene (PTFE) stent-grafts, and two stainless steel stents were deployed in three dogs with experimental carotid aneurysms. In a fourth animal, one of three aneurysms was completely occluded with GDCs. The other two aneurysms were loosely packed to ensure persistence of some residual aneurysmal lumen. Cut-film angiography, CT angiography, 3D-TOF MR angiography without and with contrast enhancement, and 3D MR DSA were performed in all dogs before and 3 weeks after treatment. RESULTS: 3D MR DSA was superior to conventional 3D-TOF MR angiography without and with contrast enhancement in accurately depicting experimental lateral aneurysms and superior to CT angiography in depicting aneurysms treated by GDCs. 3D MR DSA and CT angiography were comparable in depicting vessels treated with nitinol stents and stent-grafts, whereas CT angiography was superior for showing vessels treated by stainless steel stents. CONCLUSION: We recommend further development and clinical evaluation of 3D MR DSA for imaging cerebral aneurysms before and after treatment with GDCs. 3D MR DSA or CT angiography may be useful for evaluating vessels containing nitinol stents or nitinol-PTFE stent-grafts, whereas CT angiography should be used for follow-up of vessels treated by stainless steel stents.

Animals↗

Design and validation of a motion stage for in vitro MR experiments.

A computer-controlled motion stage was designed to facilitate motion studies and simulations of cardiac magnetic resonance (MR) experiments. The stage was constructed to move a phantom of up to 6 kg at velocities up to 15 cm/sec along a two-dimensional trajectory within an MR scanner. The operation of the motion stage was validated and found to be accurate to within 0.08 cm in displacement and 1.5 cm/sec in velocity (root-mean-square error). No image degradation was observed.J. Magn. Reson. Imaging 1999;10:972-977.

Artifacts↗

Characterization of common carotid artery blood-flow waveforms in normal human subjects.

Knowledge of human blood-flow waveforms is required for in vitro investigations and numerical modelling. Parameters of interest include: velocity and flow waveform shapes, inter- and intra-subject variability and frequency content. We characterized the blood-velocity waveforms in the left and right common carotid arteries (CCAs) of 17 normal volunteers (24 to 34 years), analysing 3560 cardiac cycles in total. Instantaneous peak-velocity (Vpeak) measurements were obtained using pulsed-Doppler ultrasound with simultaneous collection of ECG data. An archetypal Vpeak waveform was created using velocity and timing parameters at waveform feature points. We report the following timing (post-R-wave) and peak-velocity parameters: cardiac interbeat interval (T(RR)) = 0.917 s (intra-subject standard deviation = +/- 0.045 s); cycle-averaged peak-velocity (V(CYC)) = 38.8 cm s(-1) (+/-1.5 cm s(-1)); maximum systolic Vpeak = 108.2 cm s(-1) (+/-3.8 cm s(-1)) at 0.152 s (+/-0.008 s); dicrotic notch Vpeak = 19.4 cm s(-1) (+/-2.9 cm s(-1)) at 0.398 s (+/-0.007 s). Frequency components below 12 Hz constituted 95% of the amplitude spectrum. Flow waveforms were computed from Vpeak by analytical solution of Womersley flow conditions (derived mean flow = 6.0 ml s(-1)). We propose that realistic, pseudo-random flow waveform sequences can be generated for experimental studies by varying, from cycle to cycle, only T(RR) and V(CYC) of a single archetypal waveform.

Adult↗

In vitro and in vivo comparison of three MR measurement methods for calculating vascular shear stress in the internal carotid artery.

BACKGROUND AND PURPOSE: Vascular abnormalities, such as atherosclerosis and the growth and rupture of cerebral aneurysms, result from a derangement in tissue metabolism and injury that are, in part, regulated by hemodynamic stress. The purpose of this study was to establish the feasibility and accuracy of determining wall shear rate in the internal carotid artery from phase-contrast MR data. METHODS: Three algorithms were used to generate shear rate estimates from both ungated and cardiac-gated 2D phase-contrast data. These algorithms were linear extrapolation (LE), linear estimation with correction for wall position (LE*), and quadratic extrapolation (QE). In vitro experiments were conducted by using a phantom under conditions of both nonpulsatile and pulsatile flow. The findings from five healthy volunteers were also studied. MR imaging-derived shear rates were compared with values calculated by solving the fluid flow equations. RESULTS: Findings of in vitro constant-flow experiments indicated that at one or two excitations, QE has the advantage of good accuracy and low variance. Results of in vitro pulsatile flow experiments showed that neither LE* nor QE differed significantly from the predicted value of wall shear stress, despite errors of 17% and 22%, respectively. In vivo data showed that QE did not differ significantly from the predicted value, whereas LE and LE* did. The percentages of errors for QE, LE, and LE* in vivo measurements were 98.5%, 28.5%, and 36.1%, respectively. The average residual of QE was low because the residuals were both above and below baseline whereas, on average, LE* tended to be a more biased overestimator of the shear rate in volunteers. The average and peak wall shear force in five volunteers was approximately 8.10 dyne/cm2 and 13.2 dyne/cm2, respectively. CONCLUSION: Our findings show that LE consistently underestimates the shear rate. Although LE* and QE may be used to estimate shear rate, errors of up to 36% should be expected because of variance above and below the true value for individual measurements.

Biomechanical Phenomena↗

A rapid 2D time-resolved variable-rate k-space sampling MR technique for passive catheter tracking during endovascular procedures.

A new, fast, 2D MR imaging technique allowing passive catheter visualization adequate for use as a tool for guiding the movement of a catheter during endovascular procedures is described. This imaging technique samples low spatial frequencies more often than high spatial frequencies; it also uses both k-space view sharing and temporal interpolation. Unlike other techniques for passive visualization that exploit magnetic-susceptibility-induced artifacts, we have adopted a strategy that takes advantage of the T1-shortening effect of paramagnetic contrast agents, such as Gd-DTPA and a projection dephaser. This not only permits visualization of the entire catheter length but also minimizes the risk of intravascular heating. Using this method, a temporal frame rate of up to eight images per second and a tip localization accuracy of +/- 1mm (root mean square difference) can be achieved.

Angioplasty, Balloon↗

3D time-resolved contrast-enhanced MR DSA: advantages and tradeoffs.

The 3D TRICKS method for contrast-enhanced, time-resolved MR DSA has been recently described. In this paper, computer simulations are used to investigate the relative frame rate, temporal window, artery-vein temporal separation, contrast-to-noise ratio, and spatial resolution of TRICKS and conventional scans for breath-hold and non-breath-hold applications. For non-breath-hold applications, TRICKS can be configured to provide increased CNR or spatial resolution at an increased frame rate, but with a longer temporal window when compared with a series of conventional scans in which the central portion of k-space is sampled at the same rate as for the TRICKS scans. For breath-hold applications, TRICKS typically provides three images with 75% of the conventional single acquisition spatial resolution and is more tolerant of variations in contrast curve shape within the field of view.

Computer Simulation↗