Evaluation of the performance and response of the bacharach TLV sniffer and H-Nu photoionization gas analyzer to common hydrocarbon solvents.

Two direct reading instruments, the H-Nu PI 101 photoionization analyzer and the J.W. Bacharach TLV Sniffer, were evaluated under laboratory conditions to determine their performance characteristics when challenged by vapors of common hydrocarbon solvent mixtures. Each instrument was evaluated against the manufacturer's recommended test solvent for rise time, fall time, noise, span drift, zero drift, position sensitivity, battery life, and recharge time. The precision, accuracy, and operating linear range were also determined for the test solvents and some petroleum solvent mixtures which are common refinery products. For these latter mixtures, correction factors are presented which allow for an improved estimate of ambient concentrations when monitoring with each of these instruments. All tests except operating humidity range were performed by challenging each instrument with a known concentration of hydrocarbon generated by evaporating calculated liquid volumes into a static chamber. Humidity tests were performed using a dynamic dilution apparatus generating a fixed concentration of hydrocarbon while relative humidity was varied. Concentrations in both systems were verified by gas injection into gas chromatograph. Each instrument performed well when challenged by manufacturers' recommended test solvents. Humidity was shown to influence each instrument's readings. Also, the instruments were shown to have application as monitors of airborne concentrations of common hydrocarbon solvent mixtures.

Air Pollutants, Occupational↗

H2S alarms.

Explore the source record for details and available documents.

Environmental Exposure↗

A UV-conductivity method for determination of airborne levels of vinyl chloride.

A method has been developed for the measurement of vinyl chloride based on the decomposition of vinyl chloride and the subsequent measurement of the conductivity of these materials in deionized water. Air containing vinyl chloride is sampled through a glass flask containing an ultraviolet lamp. The sample rate for efficient conversion of the vinyl chloride to conductive materials is 2 liters per minute. The wavelength of the ultraviolet light emitted by the six-inch lamp is 2537 Angstroms. Ninety-two percent of the ultraviolet light emitted by the lamp is at this wavelength. The sampled air is then drawn through deionized water, the decomposition products are absorbed and the resulting conductivity measured. Vinyl chloride concentrations of less than one-tenth of a part per million can be detected by the method.

Air Pollutants↗

Interpreting noise dosimeter results based on different noise standards.

Three types of noise dosimeters were exposed on workers during routine work in a synthetic rubber plant, two refineries, a petrochemical plant, a petroleum marketing terminal and an off-shore producing platform. The dosimeters represent different methods of noise integration.

Ear Protective Devices↗