PubMed HealthSearch

Biomedical subjects

R G Craig

Publications and source records attributed to R G Craig.

At least 19 recordsLinked to original sources

In vitro synergistic, antagonistic, and duration of exposure effects of metal cations on eukaryotic cells.

Effects of duration of exposure of single metal cations (Ag+1, Cd+2, Cu+2, Ga+3, Ni+2, and Zn+2) on 3H-thymidine (3H-Tdr) incorporation and 3-[4,5-dimethyl-thiazol-2yl-]-2,5-diphenyl tetrazolium bromide-formazan (MTT-f) production in cultured murine fibroblasts (Balb/c 3T3) were investigated, and the synergistic and antagonistic effects of two metal cations applied simultaneously to the fibroblasts were assessed. The effects of duration of exposure were quantified using TC50 values (concentration of an element required to cause 50% toxicity compared with controls) measured after 24, 48, or 72 h. Using MTT-f production, Cd+2, Cu+2, Ga+3, and Ni+2 showed significantly lower TC50 values with increasing time of exposure, whereas the TC50 values for Ag+1 and Zn+2 remained constant. The TC50 values using 3H-Tdr incorporation exhibited a similar pattern with time of exposure, but the effects were less pronounced. The TC50 values for 3H-Tdr and MTT-f tended to equalize at 72 h. All combinations of cations tested (Ag-Cu, Ag-Zn, Ag-Ni, Cu-Zn, Cu-Ni, Ga-Ni, and Cu-Cd) exhibited synergistic and antagonistic effects as measured by MTT-f production. Synergistic and antagonistic effects were not necessarily mutually exclusive in the same system.

3T3 Cells

Stress analyses of four prefabricated posts.

A two-dimensional photoelastic stress analysis method was applied to study the relative magnitude of stress and concentration induced by four commercially available posts for endodontically treated teeth. Three types of threaded posts; VLock, Radix Anchor, and Flexi-Post, and one nonthreaded prefabricated post, the Para-Post Plus post were tested. Stress was recorded at installation, at vertical and inclined load, and the threaded posts were compared with the nonthreaded post. At installation and on loading, stress was induced where posts were in contact with the model. Higher apical stresses were demonstrated for the Para-Post Plus post whereas the threaded posts concentrated stress where they engaged the model through threads or flanges.

Dental Stress Analysis

Comparison of the physical properties of 11 soft denture liners.

Soft denture liners are an important treatment option for patients who have chronic soreness associated with their prostheses. The objective of this study is to determine the tensile strength, elongation, hardness, tear strength, and tear energy of eight plasticized polymers or copolymers, two silicones, and one polyphosphazene fluoroelastomer. Tests were made on samples that were stored in a humidor for 24 hours before testing. The range of data is as follows: tensile strength, 8 to 85 kg/cm2; percent elongation, 150% to 542%; hardness, 25 to 95 Shore-A units; tear energy, 1.43 x 10(6) to 40.4 x 10(6) ergs/cm2; tear resistance, 2.6 to 26.3 kg/cm. It can be concluded that (1) the data obtained can be useful in characterizing the performance of soft denture liners, (2) there is considerable variability in the physical/mechanical properties of soft denture liners, and (3) the required essential properties for soft denture liners are as yet not known.

Chemical Phenomena

Comparison of bond strength of six soft denture liners to denture base resin.

The bond strength of six commercial soft denture liners was evaluated using a modified tensile test. The soft denture liners investigated were Prolastic, VinaSoft, Flexor, Molloplast-B, Novus, and Super-Soft. The samples were processed according to the manufacturers' instructions to cured denture base resin (polymethyl methacrylate; PMMA). The soft denture liners were 10 x 10 x 3 mm and were processed between two PMMA blocks. The samples were placed in tension until failure. The mode of failure, cohesive or adhesive, was also recorded. The results of this study showed that the bond strength is related to the components of the materials. Prolastic, VinaSoft, and Flexor had the lowest bond strength to cured PMMA and ranged from 9.6 to 11.3 kg/cm2. Super-Soft, Novus, and Molloplast-B demonstrated better bond strengths and ranged from 16.7 to 17.6 kg/cm2. The bond strength of Novus could be improved by using the recommended bonding agent and bonded Novus at 26.1 kg/cm2 had the highest bond strength of all materials tested.

Adhesiveness

Viscosity of monophase addition silicones as a function of shear rate.

The viscosity of monophase addition silicone impression materials was measured as a function of shear rate. The setting of mixed catalyst and base was prevented by addition of a small amount of phenyl propiolic acid. All products showed a 6- to 10-fold decrease in viscosity with an increasing shear rate (shear thinning). The addition of phenyl propiolic acid had little or no effect on the viscosity of three materials. However, when added to the catalyst or base only of two products, it increased their viscosity and exaggerated the shear thinning effect.

Dental Impression Materials

Precision of and new methods for testing in vitro alloy cytotoxicity.

Previous studies have utilized in vitro alloy cytotoxicity tests to evaluate dental casting alloys. The purposes of this study were to: (1) evaluate the precision of the optical density and visual tests previously used, (2) evaluate a new test measuring absorbance of solubilized formazan dyes, and (3) test the correlation between these tests for cytotoxicity. Balb/c 3T3 cells were plated in 24-well culture trays at 25,000 cells/cm2 around ten types of dental casting alloys (six samples/alloy) and incubated for 72 h. Cells were histochemically stained with MTT (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyl tetrazolium bromide)/succinate for 2 h, then fixed, washed, and dried. Toxicity was measured by optical densitometer (OD) scanning, visual assessment, and 560-nm absorbance of DMSO-solubilized dyes. Measurements of rings of inhibition were not used, because they did not provide precise data, and correlated poorly with the other methods. The results were analyzed by ANOVA, Tukey intervals, and coefficients of variation (CV's). MTT required shorter incubation times for adequate staining, allowed for solubilization of the monolayers, and was less expensive than NBT (2,2'-di-p-nitro-phenyl-5,5'-diphenyl-3,3'-dimethoxy-[3,3'-dimethoxy-4,4 '-biphenylene] ditetrazolium chloride). Results showed that all three methods ranked alloy toxicities similarly (p = 0.05). The solubilization method was most discriminating due to lower CV's. Correlation between densitometer and solubilization methods was excellent (R2 = 0.96). Between-experiment CV's were generally less than 20%, and often less than 10%. Between-sample CV's were generally less than 20%.(ABSTRACT TRUNCATED AT 250 WORDS)

Analysis of Variance

The effects of cleaning on the kinetics of in vitro metal release from dental casting alloys.

The kinetics of the release of elements from six dental casting alloys into cell-culture medium was assessed by means of atomic absorption spectroscopy. Alloys were evaluated in the polished and polished-cleaned conditions so that the effects of cleaning could be determined. Auger scanning microscopy was used for analysis of the surfaces of selected alloys before and after exposure to the cell-culture medium. Release patterns for each element were characterized by the shape of the dissolution vs. time curve, concentration of the element at 12 h as a percentage of the 72-hour concentration, and the relative slope of the curve from 48 to 72 h. Three patterns of release were observed for elements in these alloys. Type I patterns had logarithmic shapes with relatively large 12-hour concentrations and low 48-72-hour slopes. Type II patterns had logarithmic shapes but with moderate 12-hour concentrations and 48-72-hour slopes. Type III patterns were polynomial in shape, had relatively low 12-hour concentrations, and had large 48-72-hour slopes. Cleaning did not change the pattern of release but did generally significantly decrease the quantities of elements released (p = 0.05). The type of dissolution vs. time curve appeared to be dependent upon the element and the composition of the alloy. When cleaning reduced dissolution, surface analyses showed that the cleaning process increased the abundance of elements such as Au and Pd and reduced the abundance of Ag and Cu. Elements which were released from the alloys were more abundant on the surface than in the bulk in both polished and polished-cleaned conditions.(ABSTRACT TRUNCATED AT 250 WORDS)

Cadmium

Cytotoxicity of a BIS-GMA dental composite before and after leaching in organic solvents.

Cell culture techniques were used to determine the source of cytotoxic agents in a commercial BIS-GMA composite. The material was polymerized according to the manufacturer's directions and leachable components were removed by room temperature extraction in ethanol, chloroform, or toluene. The leachable components in the extracts were identified using infrared spectrographic analysis. Thin layer chromatographic analysis was used to determine the number of constituents. These constituents were separated by gas chromatography and then identified by mass spectrographic analysis. Succinic dehydrogenase activity and radioactive labeling with tritiated leucine were used to evaluate cell metabolism and protein synthesis, respectively. The infrared analysis of the extracts showed that the primary component was unreacted BIS-GMA. Trace amounts of 2-hydroxy-4-methoxy-benzophenone, a light stabilizer, as well as a phenyl ester of benzoic acid which was probably degraded from BIS-GMA, were detected by the mass spectrographic method. The removal of leachable components caused a 90% decrease in toxicity compared to the nonextracted BIS-GMA samples. The extracted BIS-GMA samples showed no cellular response compared to the Teflon negative control.

Animals

The in vitro effects of metal cations on eukaryotic cell metabolism.

The in vitro cytotoxicity of nine metal cations common in dental casting alloys was evaluated using Balb/c 3T3 fibroblasts and four toxicity parameters: total protein production, 3H-leucine incorporation, 3H-thymidine incorporation, and MTT-formazan production. Concentrations causing 50% toxicity compared to controls (TC50's) and reversibility of these effects were determined. The range of potency of the metal cations was 2-3 orders of magnitude, with Cd2+ showing the greatest potency and In3+ showing the least. Potency did not correlate with atomic weight for these metals. For each metal cation, the TC50's of the various toxicity parameters were similar in most cases. However, several cations (Cu2+, Ga3+) showed greater potency with 3H-thymidine incorporation. Reversibility of the toxic effects was observed for all cations; the effects generally became irreversible at concentrations in the range of the TC50 value for each cation. Several stimulatory effects were seen. Small but statistically significant stimulations were observed after 24 h of metal exposure for Ag1+, Au4+, Cu2+, Ga3+, and Ni2+. Residual stimulations 24 h after removal of the metal cations were observed for Au4+, Cd2+, Ni2+, and Zn2+. Stimulations always occurred at concentrations below the TC50 concentrations. This study should be useful in evaluating the potential cytotoxic effects of metal cations released from dental alloys.

3T3 Cells

Modeling bacterial damage to pulpal cells in vitro.

There is increasing evidence that access to patent dentinal tubules by bacteria and their products rather than trauma from restorative materials is responsible for subsequent pulpitides. The purpose of this study was to compare the relative cytotoxicity of centrifugal fractions of two bacteria, Fusobacterium nucleatum and Treponema denticola, on L929 cells in monolayer cultures and in the "in vitro pulp chamber." Neutrophilic chemotaxis assays and Limmulus assays were performed to verify biological activity of the various fractions of these bacteria. It was found that T. denticola inhibits new protein synthesis in cultured cells to a much greater extent than F. nucleatum, but that only F. nucleatum fractions are chemoattractive for human neutrophils in the absence of serum. While the chemical nature and molecular weights of the "toxic" materials were not determined, it appeared that eukaryotic protein synthesis inhibition caused by the T. denticola pellet fraction in the in vitro pulp chamber was at least 1000 times less than that caused by the same concentrations in monolayer cultures.

Cells, Cultured

The release of elements of dental casting alloys into cell-culture medium.

Ten dental casting alloys were tested for alloy-element release into cell-culture medium, and this release was related to alloy composition, alloy microstructure, and alloy cytotoxicity (previously determined). Cell-culture medium was analyzed for alloy elements by flame atomic absorption. Concentrations of elements in the medium were normalized by dividing them by their atomic abundance in the alloy, giving element medium-alloy ratios (EMA ratios). Results showed that Au, In, and Pd generally did not dissolve into the medium, but that Ag, Cd, Cu, Ga, Ni, and Zn frequently dissolved. Comparison of EMA ratios for Ag, Cu, and Zn showed that each element retained a behavioral identity in diverse metallurgical environments, but that these environments influenced the release behavior to some degree. Some EMA ratios in multiphase alloys were greater than those in solid solutions, and EMA ratios showed great diversity within all the alloys. Nominal composition seemed to be of little value in the prediction of metal release unless the composition supported multiple-phase formation. In addition, release of alloy elements did not, in itself, completely predict alloy cytotoxicity measured previously. However, cytotoxicity was associated with metal release in each case. The commercial alloys used in this study exhibited more complex and less predictable release behavior than did the simpler ternary alloy systems used by previous investigators. It is believed that the use of commercial preparations is necessary for their in vivo behavior to be modeled.

Copper

Cytotoxic effects of resin components on cultured mammalian fibroblasts.

The objectives of this study were to determine the cytotoxic concentrations of 11 components of resin composites on monolayers of cultured Balb/c 3T3 fibroblasts, to study the inhibitory effects of these components on DNA synthesis, total protein content, and protein synthesis, and to determine whether effects were reversible when the components were withdrawn from the medium. These data were reported as concentrations which inhibited 10% (ID10) and 50% (ID50) of a particular metabolic process as well as the range of concentrations over which cell metabolism was irreversibly inhibited. For any individual component, the ID50 values for all three metabolic parameters were of the same magnitude. The same was true for the ranges of irreversibility. Ethoxylated Bis-phenol A dimethacrylate (E-BPA) was the most toxic molecule of the group (ID50 being between 1 and 10 mumol/L). The ID50 concentrations for three of the components, including Bis-GMA, UDMA, TEGDMA, and Bis-phenol A, ranged between 10 and 100 mumol/L, while the ID50 values of three components (N,N dihydroxyethyl-p-toluidine, camphoroquinone, and N,N dimethylaminoethyl methacrylate) were above 100 mumol/L. The concentrations to which the cells and tissues are exposed in vivo are not known. This study should help to identify the concentrations of organic composite components which pose clinical cytotoxic hazards.

Animals

Lipid composition and biosynthesis in the gingiva of the domestic cat.

Periodontal disease in the domestic cat may assume debilitating and serious consequences; however, little is known of the biochemical composition or metabolism of feline gingiva in health or disease. In this report the chemical composition and metabolism of gingival lipids from inflamed an non-inflamed sites is presented and compared to other species with naturally occurring periodontitis. The neutral and phospholipid composition of feline gingiva was found to be distinct from that of porcine and human. As a measure of de novo lipid synthesis, the total incorporation of 14C-acetate into fractionated lipid components was determined and revealed an approximate 2 to 3 fold decrease in inflamed versus non-inflamed gingiva. The decrease in 14C-acetate incorporation appeared to result from a 2-fold increase in free acetate pools in inflamed compared to non-inflamed gingival samples, since total lipase and phospholipase activity were comparable in inflamed and non-inflamed gingiva and total lipid composition was not changed between inflamed and non-inflamed sites. These data are similar to those reported for periodontally involved human gingival tissue and suggest a common effect of periodontal inflammation on lipid metabolism in both species.

Acetates

Denture materials and acrylic base materials.

Modifications in denture plastics, including acrylics containing butadiene-styrenes, block copolymers to increase toughness, and those with added soluble heavy-element salts to increase radiopacity are described. Developments in processing of denture bases by microwave, laser, and injection methods are described. Also reviewed are acrylics and their dimensional stability, including the effect of artificial salivas on properties. In addition, the rheological, glass transition, dynamic, impact, and fatigue properties of denture acrylics are presented. Adhesion of polymers to plastics and metals is reviewed, as well as the biocompatibility and adhesion of organisms to denture plastics. Soft denture materials are reviewed with respect to research on new materials and to clinical evaluations of existing products. Finally, studies on the wear of denture teeth are summarized.

Acrylic Resins

Comparison of the accuracy of denture bases by a non-parametric method.

A comparison of the accuracy of denture bases made from a conventional acrylic and four modified acrylic resins was made with the use of a non-parametric method. Twenty-five identical maxillary stone casts were made and five dentures for each resin were processed by conventional compression moulding techniques. The fit of each denture at the molar-to-molar region on its cast was evaluated by five evaluators who independently ranked the twenty-five dentures from best to worst fit after processing, after polishing, and after storage in water at 37 degrees C for 42 days. The ranking data were analysed by Kendall's coefficient of concordance, the Kruskal-Wallis statistic, and the Mann-Whitney test. Excellent agreement among observers was obtained. After storage in water, two modified acrylic resins, Hydrocryl and Vitalon II, had a better fit on their casts than the conventional acrylic, Lucitone Hypro. Luciton 199 had the same and Hircoe had a poorer fit than Lucitone Hypro.

Acrylic Resins

Wear of composites by abrasives of varying hardness.

The relationship between the wear of three composite resins and the hardness of the abrasive was studied by a two-body abrasion test. The wear rates of the composites increased linearly with abrasive hardness from 530 to 2080 KHN. Measurement of the slope of the wear rate versus abrasive hardness over this range provided a sensitive method for ranking the composites.

Aluminum Oxide

Modifying the setting rate of an addition-type silicone impression material.

Two methods for controlling the working time of an addition-type silicone impression material are presented. The progress of the polymerization reaction of this modified system was studied using viscosity and a new "compression set" technique. The physical properties are presented and compared to those typical of condensation silicones, and a method of clinical use is suggested.

Alkynes

Color stability of a pigmented elastomer for maxillofacial appliances.

The color stability of a series of eleven maxillofacial pigments was determined after accelerated aging using reflection spectrophotometry. The results indicate that seven of the pigments demonstrated good to excellent color stability, while four of the pigments were less promising for clinical use.

Color