PubMed Health⌕ Search

Biomedical subjects

R G Dong

Publications and source records attributed to R G Dong.

17 recordsLinked to original sources

Analysis of the point mechanical impedance of fingerpad in vibration.

Biodynamic responses of the finger-hand-arm system, such as apparent mass and mechanical impedance, characterize the relationship between the motion of the finger-hand-arm system and the dynamic force acting on the driving point, and they are useful for vibration exposure assessment. In the present study, a two-dimensional finite element (FE) model has been proposed to simulate the biodynamic responses of the fingerpad in vibration tests. The fingernail was supported by the rigid ground while the fingerpad was activated by a vibration probe. The fingertip model is composed of skin, subcutaneous tissue, bone, and nail. The soft tissues (i.e., skin and subcutaneous tissues) were assumed to be non-linearly elastic and linearly viscoelastic. The FE model was applied to predict the effects of pre-indentation of the vibration probe onto the fingerpad, the damping of the soft tissues, and probe mass on the magnitude and phase angle of the mechanical impedance and the apparent mass, as measured in the vibration tests. The model predictions showed that the probe mass has non-negligible effects on the measured biodynamic responses in the vibration tests. In order to determine "true" biodynamic responses of the finger-hand-arm system, the mass effects have to be cancelled using an appropriate approach. The present analysis provided a theoretical explanation, from a biomechanical point-of-view, for the inconsistencies in the published experimental data for the biodynamic responses of fingerpad.

Biomechanical Phenomena↗

Acute vibration increases alpha2C-adrenergic smooth muscle constriction and alters thermosensitivity of cutaneous arteries.

The vascular symptoms of hand-arm vibration syndrome, including cold-induced vasospasm, are in part mediated by increased sensitivity of cutaneous arteries to sympathetic stimulation. The goal of the present study was to use a rat tail model to analyze the effects of vibration on vascular function and alpha-adrenoceptor (AR) responsiveness. Rats were exposed to a single period of vibration (4 h, 125 Hz, constant acceleration 49 m/s2 root mean square). The physical or biodynamic response of the tail demonstrated increased transmissibility or resonance at this frequency, similar to that observed during vibration of human fingers. Morphological analysis demonstrated that vibration did not appear to cause structural injury to vascular cells. In vitro analysis of vascular function demonstrated that constriction to the alpha1-AR agonist phenylephrine was similar in vibrated and control arteries. In contrast, constriction to the alpha2-AR agonist UK14304 was increased in vibrated compared with control arteries, both in endothelium-containing or endothelium-denuded arteries. The alpha2C-AR antagonist MK912 (3 x 10(-10) M) inhibited constriction to UK14304 in vibrated but not control arteries, reversing the vibration-induced increase in alpha2-AR activity. Moderate cooling (to 28 degrees C) increased constriction to the alpha2-AR agonist in control and vibrated arteries, but the magnitude of the amplification was less in vibrated compared with control arteries. Endothelium-dependent relaxation to acetylcholine was similar in control and vibrated arteries. Based on these results, we conclude that a single exposure to vibration caused a persistent increase in alpha2C-AR-mediated vasoconstriction, which may contribute to the pathogenesis of vibration-induced vascular disease.

Adrenergic alpha-Agonists↗

Analysis of the dynamic strains in a fingertip exposed to vibrations: Correlation to the mechanical stimuli on mechanoreceptors.

The reduction in vibrotactile sensitivity in the fingertip is assumed to be associated with the exposure of the tissues to repetitive, non-physiological strains during dynamic loading. Experimental results demonstrated that the magnitude of a vibration-induced temporary threshold shift is dependent upon the vibration frequency of both the exposure and testing stimuli. In the present study, the frequency-dependent strain imposed on cutaneous and subcutaneous tissues of the fingertip is analyzed theoretically using a finite element model. The proposed fingertip model is two-dimensional and includes major anatomical substructures: skin, subcutaneous tissue, bone, and nail. The soft tissues (skin and subcutaneous tissues) were assumed to be nonlinearly elastic and viscoelastic, while the bone and nail were considered as linearly elastic. Simulations were performed for the contact between the fingertip and a flat surface for four different pre-compressions (0.5, 1.0, 1.5, and 2.0 mm). The frequency-dependent distributions of the dynamic strain magnitudes in the soft tissues were investigated. The model predictions indicated that the vibration exposure at a frequency range from 63 to 250 Hz will induce excessive dynamic strain in the deep zone of the finger tissues, effectively inhibiting the high-frequency mechanoreceptors; while the vibration exposure at low frequency (less than 31.5 Hz) tends to induce excessive dynamic strain in superficial layer in the tissues, inhibiting the low-frequency mechanoreceptors. These theoretical predictions are consistent with the experimental observations in literature. The proposed model can be used to predict the responses of the soft tissues in different depths to vibration exposures, providing valuable information and data that are essential for improving vibrotactile perception tests.

Fingers↗

Distribution of mechanical impedance at the fingers and the palm of the human hand.

A comprehensive understanding of the complex biodynamic response of the human fingers-hand-arm system may help researchers determine the causation of injuries arising from hand-transmitted vibration. This study theoretically demonstrates that the mechanical impedance (MI) in a hand power grip, as a measure of the biodynamic response of the system, can be divided into finger MI and palm MI. A methodology is developed to measure them separately and to investigate their distribution characteristics. This study involves 6 adult male subjects, constant-velocity sinusoidal excitations at 10 different discrete frequencies (16, 25, 40, 63, 100, 160, 250, 400, 630, 1000 Hz), and three different hand-handle coupling conditions. Our results suggest that at low frequencies (40 Hz), the palm MI is substantially higher than the finger MI; the majority of the hand MI remains distributed at the palm up to 100 Hz; and at frequencies higher than 160 Hz, the finger MI is comparable to or higher than the palm MI. Furthermore, at frequencies equal to or above 100 Hz, the finger MI is practically independent of the palm-handle coupling conditions. Knowledge of the MI distribution pattern may increase the understanding of vibration transmission to the hand and aid in the development of effective isolation devices.

Biomechanical Phenomena↗

Analysis of the contact interactions between fingertips and objects with different surface curvatures.

Previous experimental observations indicated that the contact interactions between finger and tool handle interfere with the grasp stability, affecting the comfort and manipulations of handheld tools. From a biomechanical point of view, the curvature of the contact surface should affect the contact pressure and contact area, and thereby the comfort and manipulations of hand tools. The current authors analysed, via a finite element model, the contact interactions between fingertips and objects with different curvatures. The effects of the curvature on the contact stiffness, fingertip deformations, contact pressure distributions, and stress/strain distributions within the soft tissues were analysed. The simulation results indicated that the curvature of the contact interface influences the contact characteristics significantly. For a given contact force, the contact area and the contact stiffness increase but the contact pressure and the fingertip deformation decrease with the decrease of the contact surface curvature. The present simulation results will be useful for ergonomic designers in their aim to improve the design of tool handles.

Animals↗

A structural fingertip model for simulating of the biomechanics of tactile sensation.

Tactile performance of human fingertips is associated with activity of the nerve endings and sensitivity of the soft tissue within the fingertip to the static and dynamic skin indentation. The nerve endings in the fingertips sense the stress/strain states developed within the soft tissue, which are affected by the material properties of the tissues. The vibrotactile sensation and tactile performance are thus believed to be strongly influenced by the nonlinear and time-dependent properties of the soft tissues. The purpose of the present research is to simulate the biomechanics of tactile sensation. A two-dimensional model, which incorporates the essential anatomical structures of a finger (i.e. skin, subcutaneous tissue, bone, and nail), has been used for the analysis. The skin tissue is assumed to be hyperelastic and viscoelastic. The subcutaneous tissue is considered to be a nonlinear, biphasic material composed of a hyperelastic solid and an inviscid fluid phase. The nail and bone are considered to be linearly elastic. The advantages of the proposed fingertip model over the previous "waterbed" and "continuum" fingertip models include its ability to predict the deflection profile of the fingertip surface, the stress and strain distributions within the soft tissue, and most importantly, the dynamic response of the fingertip to mechanical stimuli. The proposed model is applied to simulate the mechanical responses of a fingertip under a line load, and in one-point (1PT) and two-point (2PT) tactile discrimination tests. The model's predictions of the deflection profiles of a fingertip surface under a line load agree well with the reported experimental data. Assuming that the mechanoreceptors in the dermis sense the stimuli associated with normal strains (the vertical and horizontal strains) and strain energy density, our numerical results suggest that the threshold of 2PT discrimination may lie between 2.0 and 3.0 mm, which is consistent with the published experimental data. The present study represents an effort to develop a structural model of the fingertip that incorporates its anatomical structure, and the nonlinear and time-dependent properties of the soft tissues.

Animals↗

Vibration energy absorption (VEA) in human fingers-hand-arm system.

A methodology for measuring the vibration energy absorbed into the fingers and the palm exposed to vibration is proposed to study the distribution of the vibration energy absorption (VEA) in the fingers-hand-arm system and to explore its potential association with vibration-induced white finger (VWF). The study involved 12 adult male subjects, constant-velocity sinusoidal excitations at 10 different discrete frequencies in the range of 16-1000 Hz, and four different hand-handle coupling conditions (finger pull-only, hand grip-only, palm push-only, and combined grip and push). The results of the study suggest that the VEA into the fingers is considerably less than that into the palm at low frequencies (< or = 25 Hz). They are, however, comparable under the excitations in the 250-1000 Hz frequency range. The finger VEA at high frequencies (> or = 100 Hz) is practically independent of the hand-handle coupling condition. The coupling conditions affect the VEA into the fingers and the palm very differently. The finger VEA results suggest that the ISO standardized frequency weighting (ISO 5349-1, 2001) may underestimate the effect of high frequency vibration on vibration-induced finger disorders. The proposed method may provide new opportunities to examine VEA and its association with VWF and other types of vibration-induced disorders in the hand-arm system.

Arm↗

An evaluation of the standardized chipping hammer test specified in ISO 8662-2.

OBJECTIVES: Prolonged exposure to severe chipping hammer vibration may cause hand-arm vibration syndrome. A reliable test method is required to select appropriate tools and assist in the development of better chipping hammers. In the present study, the ISO standardized test method (ISO 8662-2, 1992) was examined through an investigation of the vibration characteristics of chipping hammers operating on the energy absorber specified in the standard. METHODS: The energy absorber and test setup were designed and constructed based on those specified in the standard. The experiment employed six subjects and used two pneumatic chipping hammers and three different feed forces (50, 100 and 200 N). The subject posture was the same as that specified in the standard. RESULTS: The vibration emission at the tool dominant frequency (or air blow rate) generally declined with an increase in feed force, thus decreasing the frequency-weighted accelerations. The increase in feed force, however, resulted in an increase in the unweighted vibration emission at high frequencies. The chipping hammer vibration emission operating on the energy absorber at the high feed force (200 N) was inconsistent. CONCLUSIONS: The measurement method has a good repeatability except at a high feed force. The feed force has a significant effect on the vibration emission. The single feed force specified in the standard may not be sufficient to test the tool behaviors. Multiple levels of feed force should be used for the chipping hammer test. Doing so may provide a more appropriate basis for tool screening.

Analysis of Variance↗

Biodynamic response of human fingers in a power grip subjected to a random vibration.

BACKGROUND: Knowledge of the biodynamic response (BR) of the human hand-arm system is an important part of the foundation for the measurement and assessment of hand-transmitted vibration exposure. This study investigated the BR of human fingers in a power grip subjected to a random vibration. METHOD: Ten male subjects were used in the experiment. Each subject applied three coupling actions to a simulated tool handle at three different finger grip force levels. RESULTS AND CONCLUSIONS: The BR is practically independent of the hand coupling actions for frequencies at or above 100 Hz. Above 50 Hz, the BR is correlated to finger and hand sizes. Increasing the finger coupling force significantly increases the BR. Therefore, hand forces should be measured and used when assessing hand-transmitted vibration exposure. The results also show that under a constant-velocity vibration, the finger vibration power absorption at frequencies above 200 Hz is approximately twice that at frequencies below 100 Hz. This suggests that the frequency weighting specified in the current ISO 5349-1 (2001) may underestimate the high frequency effect on vibration-induced finger disorders.

Algorithms↗

Elimination of the friction effects in unconfined compression tests of biomaterials and soft tissues.

The mechanical properties of biomaterials and soft tissues are determined conventionally using unconfined compression tests. In such tests, frictionless specimen/platen contact in unconfined compression tests has to be assumed in determining the material properties of the materials. Previous theoretical analysis demonstrated, however, that the effects of the friction at the specimen/platen contact interface on the measured stress responses are non-negligible. In this study, a computational approach was proposed to eliminate the effects of friction. The friction coefficient between the specimen and the compression platens is measured first. Using a finite element model, the stress-strain relationship, without the influence of the friction effects, can be derived from the experimental data obtained in conventional unconfined compression tests. In order to validate the proposed approach, unconfined compressive tests of rubber have been performed.

Algorithms↗

Modeling of time-dependent force response of fingertip to dynamic loading.

An extended exposure to repeated loading on fingertip has been associated to many vascular, sensorineural, and musculoskeletal disorders in the fingers, such as carpal tunnel syndrome, hand-arm vibration syndrome, and flexor tenosynovitis. A better understanding of the pathomechanics of these sensorineural and vascular diseases in fingers requires a formulation of a biomechanical model of the fingertips and analyses to predict the mechanical responses of the soft tissues to dynamic loading. In the present study, a model based on finite element techniques has been developed to simulate the mechanical responses of the fingertips to dynamic loading. The proposed model is two-dimensional and incorporates the essential anatomical structures of a finger: skin, subcutaneous tissue, bone, and nail. The skin tissue is assumed to be hyperelastic and viscoelastic. The subcutaneous tissue was considered to be a nonlinear, biphasic material composed of a hyperelastic solid and an invicid fluid, while its hydraulic permeability was considered to be deformation dependent. Two series of numerical tests were performed using the proposed finger tip model to: (a) simulate the responses of the fingertip to repeated loading, where the contact plate was assumed to be fixed, and the bone within the fingertip was subjected to a prescribed sinusoidal displacement in vertical direction; (b) simulate the force response of the fingertip in a single keystroke, where the keyboard was composed of a hard plastic keycap, a rigid support block, and a nonlinear spring. The time-dependent behavior of the fingertip under dynamic loading was derived. The model predictions of the time-histories of force response of the fingertip and the phenomenon of fingertip separation from the contacting plate during cyclic loading agree well with the reported experimental observations.

Bone and Bones↗

Dynamic interaction between a fingerpad and a flat surface: experiments and analysis.

Many neural and vascular diseases in hands and fingers have been related to the degenerative responses of local neural and vascular systems in fingers to excessive dynamic loading. Since fingerpads serve as a coupling element between the hand and the objects, the investigation of the dynamic coupling between fingertip and subjects could provide important information for the understanding of the pathomechanics of these neural and vascular diseases. In the present study, the nonlinear and time-dependent force responses of fingertips during dynamic contact have been investigated experimentally and theoretically. Four subjects (2 male and 2 female) with an average age of 24 years participated in the study. The index fingers of right and left hands of each subject were compressed using a flat platen via a micro testing machine. A physical model was proposed to simulate the nonlinear and time-dependent force responses of fingertips during dynamic contact. Using a force relaxation test and a fast loading test at constant loading speed, the material/structural parameters underlying the proposed physical model could be identified. The predicted rate-dependent force/displacement curves and time-histories of force responses of fingertips were compared with those measured in the corresponding experiments. Our results suggest that the force responses of fingertips during the dynamic contacts are nonlinear and time-dependent. The physical model was verified to characterize the nonlinear, rate-dependent force-displacement behaviors, force relaxations, and time-histories of force responses of fingertips during dynamic contact.

Adult↗

Simulation of mechanical responses of fingertip to dynamic loading.

Extended exposure to mechanical vibration has been related to many vascular, sensorineural and musculoskeletal disorders of the hand-arm system, frequently termed 'hand-arm vibration syndrome' (HAVS). A two-dimensional, nonlinear finite element model of a fingertip is developed to study the stress and strain fields of the soft tissue under dynamic loading, that may be encountered while grasping and operating a hand-held power tool. The model incorporates the most essential anatomical elements of a fingertip, such as soft tissue, bone, and nail. The finger is assumed to be in contact with a steel plate, simulating the interaction between the fingertip and a vibrating machine tool or handle. The soft tissue is assumed to be nonlinearly visco-elastic, while the nail, bone, and steel plate are considered to be linearly elastic. In order to study the time-dependent deformation behavior of the fingertip, the numerical simulations were performed under ramp-like loading with different ramping periods and sinusoidal vibrations of the contacting plate at three different frequencies (1, 10, and 31.5 Hz). Owing to relatively large deformations of the soft tissue under specified static and dynamic loading, Lagrangian large deformation theory was applied in the present analysis. The effects of the loading rate and the frequency of the sinusoidal vibration on the time-dependent strain/stress distributions in the different depth within the soft tissue of the fingertip are investigated numerically. Our simulations suggest that the soft tissue of the fingertip experiences high local stress and strain under dynamic loading and the fingertip may separate from the vibrating contact surface due to the viscous deformation behaviour of the soft tissue. For a given deformation, the high frequency loading produces a higher stress in the tissues compared to that obtained at a low frequency loading. The present model may serve as a useful tool to study the mechanism of tissue degeneration under vibratory loading encountered during operation of hand-held power tools.

Computer Simulation↗

A method for reducing adaptor misalignment when testing gloves using ISO 10819.

OBJECTIVES: International standard ISO 10819 was established in order to quantify the vibration attenuation characteristics of anti-vibration gloves. One problem that exists with the standard is possible misalignment of the palm adaptor that is placed underneath the test glove. If the adaptor becomes misaligned, the measured glove transmissibility will be lower than the actual value. A tri-axial accelerometer was installed in the adaptor and was used as the basis for providing visual feedback of the adaptor alignment to the test subjects. The objective of this study was to test the hypothesis that adaptor misalignment could be reduced by providing feedback to the test subjects. METHODS: Eight male volunteers (mean age 24.8 yr) were used in the study. Each subject performed two sets of tests: the standard ISO 10819 glove test and the modified version. Three different anti-vibration gloves were tested. Glove transmissibility and adaptor misalignment were calculated for each glove. A three-way analysis of variance was used to analyze the results. RESULTS: A comparison of the two testing methods showed that the modified glove testing method did reduce misalignment significantly, which, in turn, resulted in an increase in the measured glove transmissibility. CONCLUSIONS: The proposed method greatly improved the standard deviation of transmissibility and made the test results more consistent.

Adult↗

Hand-transmitted vibration and biodynamic response of the human hand-arm: a critical review.

Hand-arm vibration syndrome (HAVS) has been associated with prolonged exposure to vibration transmitted to the human hand-arm system from hand-held power tools, vibrating machines, or hand-held vibrating workpieces. The biodynamic response of the human hand and arm to hand transmitted vibration (HTV) forms an essential basis for effective evaluations of exposures, vibration-attenuation mechanisms, and potential injury mechanisms. The biodynamic response to HTV and its relationship to HAVS are critically reviewed and discussed to highlight the advances and the need for further research. In view of its strong dependence on the nature of HTV and the lack of general agreement on the characteristics of HTV, the reported studies are first reviewed to enhance an understanding of HTV and related issues. The characteristics of HTV and relevant unresolved issues are discussed on the basis of measured data, proposed standards, and measurement methods, while the need for further developments in measurement systems is emphasized. The studies on biodynamic response and their findings are grouped into four categories based on the methodology used and the objective. These include studies on (1) through-the-hand-arm response, expressed in terms of vibration transmissibility; (2) to-the-hand response, expressed in terms of the force-motion relationship of the hand-arm system; (3) to-the-hand biodynamic response function, expressed in terms of vibration energy absorption; and (4) computer modeling of the biodynamic response characteristics.

Arm↗

Analysis of skin deformation profiles during sinusoidal vibration of fingerpad.

Vibrotactile perception threshold measurement has been widely used to diagnose the severity of peripheral neuropathy associated with hand-arm vibration syndrome and sensory losses in stroke and diabetic patients. The vibration perception threshold is believed to be influenced by many factors, such as contact force and vibration frequency. The present study is intended to analyze, theoretically, the time-dependent deformation profile of skin surface, strain distributions within soft tissue, and response force of a fingertip when it is stimulated by a probe vibrating with a sinusoidal movement. A two-dimensional finite element model, which incorporates the essential anatomical structures of a finger: skin, subcutaneous tissue, bone, and nail, has been proposed to analyze the effects of vibration amplitude, frequency, and preindentation on the dynamic interaction between the fingerpad and vibrating probe. The simulation results suggest that the fraction of time over which the skin separates from the probe during vibration increases with increasing vibration frequency and amplitude, and decreases with increased preindentation of the probe. The preindentation of the probe has been found to significantly reduce the trend of skin/probe decoupling. The simulation results show reasonably consistent trends with the reported experimental data.

Adaptation, Physiological↗

Efficacy of endoscopic sinus surgery in the management of patients with asthma and chronic sinusitis.

An association between chronic sinusitis and asthma has been noted for many years, although the precise nature of the relationship is poorly understood. Earlier studies, using traditional surgical techniques, have demonstrated subjective improvement in asthmatic complaints. Reports demonstrating improvement following endoscopic sinus surgery for chronic sinusitis are rare. To report our experience with endoscopic sinus surgery and asthmatics, we reviewed the charts of 75 consecutive patients with asthma and chronic sinusitis who underwent endoscopic sinus surgery between 1994 and 1996. Study criteria included the following: chronic sinusitis, one year preoperative and one year postoperative follow-up from endoscopic sinus surgery, and asthma requiring inhaled steroids and oral prednisone for control. Many patients required prednisone bursts for control of asthma. Number of days and total dose of oral prednisone were used as objective measures of asthma control. Number of weeks of antibiotics was used as a relative measure of sinusitis. Fourteen of the 15 patients meeting study criteria decreased their postoperative prednisone requirement by total number of days (preoperative 84 versus postoperative 63 days [p < 0.0001]). Postoperatively, patients required an average of 1300 mg less oral prednisone (p < 0.033). Antibiotic use also decreased, with an average use of antibiotic nine weeks preoperatively versus seven weeks postoperatively (p < 0.045). This study provides corroborative objective evidence that, at least in the short term, endoscopic sinus surgery is efficacious in the management of patients with chronic sinusitis and asthma.

Adolescent↗