PubMed Health⌕ Search

Biomedical subjects

R G Ellison

Publications and source records attributed to R G Ellison.

At least 37 records · Page 2Linked to original sources

Permanent cardiac pacemakers: twelve-year experience with 287 patients.

Our total pacemaker experience was evaluated to determine survival, complications, effectiveness of follow-up techniques, and future goals for surveillance. A retrospective review of 287 patients with 570 pulse generators revealed 164 alive and 104 dead; 3 recovered normal conduction, 14 transferred care, and 2 have been lost to follow-up. Average age at initial implantation was 67 years. Overall mean generator life has been 22 months. The one-, three-, five-, and ten-year survival is 84, 71, 60, and 39%, respectively. The 738 operations performed averaged 2.6 procedures per patient. Of the total survivors, 108 (66%) had no complications; 56 (34%) have had at least one complication, 70% during the first year of the initial implantation. Fifty episodes of premature interruption of pacing service were detected. Ninety-one patients (32% of the group) have required an operative procedure on their pacemaker system more frequently than every two years. Of the replacements, 89 (29%) were for reasons other than end of generator life; 66 (63%) of the deaths occurred before replacement of the first generator. Mortality in the first two years was 23%. Once survival exceeded two years the average annual death rate was 3.7% (expected, 3.2%). Survival in our series compares favorably with that of other groups who report by the actuarial method. These data suggest that some deaths, reduced patient productivity, and the high cost to health care providers may be due in part to inadequate follow-up after the first pacemaker implantation. If follow-up observation is done frequently during the first year after initial implantation and once minimum generator longevity has passed, the goals of pacemaker therapy may be achieved.

Adolescent↗

Twelve-year experience with mitral valve replacement.

Between 1962 and 1974, 203 mitral prostheses were implanted in 201 patients. Of the 102 survivors, 29 have Beall, 25 Kay-Shiley, 22 Starr-Edwards (SE) 6000, and 27 SE 6320 valves. Full rehabilitation was achieved in 25 patients with Beall and 23 with SE 6320 valves. Sixteen with SE 6000 valves remain normally active. Only 8 with Kay-Shiley prostheses have resumed normal activities. Systemic embolization occurred with the following frequencies per 1,000 patient-months: 13.7 for those receiving the Kay-Shiley valve; 7.2 in the SE 6000 group; 4.3 after SE 6320 implantations; and 3;1 for the Beall group. Other prosthesis-related complications that were much less frequent included detachment (10), bacterial endocarditis (5), and hemolysis (10). Three Kay-Shiley valves malfunctioned. Life table analyses reveal the following survival rates: 33% after 11 years in the SE 6000 patients, 50% after 7.5 years in the Kay-Shiley group, 69% 2.5 years after SE 6320 implantation, and 65% 3.5 years after replacement with a Beall valve. Evidence is presented to support the extension of operative treatment to patients with less advanced valvular heart disease. Postoperative anticoagulation remains an unresolved issue despite lower rates of thromboembolism. More cumulative analyses of survival and morbidity and follow-up hemodynamic data are needed to assess the Beall and SE 6320 prostheses now employed in our valve replacement program.

Adolescent↗