Genotoxic effects in workers exposed to low levels of benzene from gasoline.

To study genotoxic effects of exposure to low levels of benzene, single-strand breaks (SSB) in DNA of leukocytes and urinary levels of the oxidative DNA adduct 8-hydroxydeoxyguanosine (8OHdG) were determined in 33 men occupationally exposed to benzene from gasoline and in 33 controls. The average exposure to benzene over a shift was determined by personal air sampling in the breathing zone. The 8-hr time-weighted average exposure to benzene was 0.13 ppm (mean value, range 0.003-0.6 ppm). Exposed workers had a significant increase of SSB (p = 0.04) over the shift compared with controls. Storage time of the samples seemed to affect the results. An analysis of samples with the same storage time showed a nonsignificant increase among the workers compared with controls. Urinary 8OHdG increased over the shift among the exposed workers but not among the controls. The highest values among the exposed workers were seen in late evening, with a slight decrease the next morning. Multiple linear analysis adjusting for smoking habits showed a significant association between the exposure level of benzene during the shift and the increase of 8OHdG in the urine over the shift among exposed workers (p = 0.02). These findings indicate a genotoxic effect in humans of benzene at relatively low exposure levels, that is, about 0.1 ppm (0.3 mg/m3).

Adult↗

A field method for sampling benzene in end-exhaled air.

A simple and reliable field method is presented for sampling and analysis of benzene in end-exhaled air. The sample is collected directly on an adsorbent tube while the subject exhales through a sampling device consisting of a modified peak expiratory flow meter. To ensure sampling of end-exhaled air, the temperature of the breath is monitored during expiration. The analytes subsequently are thermally desorbed and analyzed by gas chromatography. No sample preparation before analysis is needed, and therefore sample loss is minimized, shipping is easy, storage is possible, and clean up is unnecessary. All these steps have been major problems in earlier methods for breath analysis. The presented method has been applied to the monitoring of benzene. The separation of benzene from other components of exhaled air was good and the detection limit low (0.5 microgram/m3), and therefore benzene could be monitored in occupationally nonexposed nonsmokers. No carry-over in the sampling device or breakthrough could be detected. The samples were stable for at least a week. The combined precision in sampling and analysis was excellent, with a coefficient of variation of 13%.

Adsorption↗