PubMed Health⌕ Search

Biomedical subjects

R G Querry

Publications and source records attributed to R G Querry.

5 recordsLinked to original sources

Neural blockade during exercise augments central command's contribution to carotid baroreflex resetting.

This investigation was designed to determine central command's role on carotid baroreflex (CBR) resetting during exercise. Nine volunteer subjects performed static and rhythmic handgrip exercise at 30 and 40% maximal voluntary contraction (MVC), respectively, before and after partial axillary neural blockade. Stimulus-response curves were developed using the neck pressure-neck suction technique and a rapid pulse train protocol (+40 to -80 Torr). Regional anesthesia resulted in a significant reduction in MVC. Heart rate (HR) and ratings of perceived exertion (RPE) were used as indexes of central command and were elevated during exercise at control force intensity after induced muscle weakness. The CBR function curves were reset vertically with a minimal lateral shift during control exercise and exhibited a further parallel resetting during exercise with neural blockade. The operating point was progressively reset to coincide with the centering point of the CBR curve. These data suggest that central command was a primary mechanism in the resetting of the CBR during exercise. However, it appeared that central command modulated the carotid-cardiac reflex proportionately more than the carotid-vasomotor reflex.

Adult↗

Anatomical and functional characteristics of carotid sinus stimulation in humans.

Transmission characteristics of pneumatic pressure to the carotid sinus were evaluated in 19 subjects at rest and during exercise. Either a percutaneous fluid-filled (n = 12) or balloon-tipped catheter (n = 7) was placed at the carotid bifurcation to record internal transmission of external neck pressure/neck suction (NP/NS). Sustained, 5-s pulses, and rapid ramping pulse protocols (+40 to -80 Torr) were recorded. Transmission of pressure stimuli was less with the fluid-filled catheter compared with that of the balloon-tipped catheter (65% vs. 82% negative pressure, 83% vs. 89% positive pressure; P < 0.05). Anatomical location of the carotid sinus averaged 3.2 cm (left) and 3.6 cm (right) from the gonion of the mandible with a range of 0-7.5 cm. Transmission was not altered by exercise or Valsalva maneuver, but did vary depending on the position of the carotid sinus locus beneath the sealed chamber. These data indicate that transmission of external NP/NS was higher than previously recorded in humans, and anatomical variation of carotid sinus location and equipment design can affect transmission results.

Adult↗

Differential baroreflex control of heart rate in sedentary and aerobically fit individuals.

PURPOSE: We compared arterial, aortic, and carotid-cardiac baroreflex sensitivity in eight average fit (maximal oxygen uptake, VO2max = 42.2+/-1.9 mL x kg(-1) x min(-1)) and eight high fit (VO2max = 61.9+/-2.2 mL x kg(-1) x min(-1)) healthy young adults. METHODS: Arterial and aortic (ABR) baroreflex functions were assessed utilizing hypo- and hyper-tensive challenges induced by graded bolus injections of sodium nitroprusside (SN) and phenylephrine (PE), respectively. Carotid baroreflex (CBR) sensitivity was determined using ramped 5-s pulses of both pressure and suction delivered to the carotid sinus via a neck chamber collar, independent of drug administration. RESULTS: During vasoactive drug injection, mean arterial pressure (MAP) was similarly altered in average fit (AF) and high fit (HF) groups. However, the heart rate (HR) response range of the arterial baroreflex was significantly attenuated (P < 0.05) in HF (31+/-4 beats x min(-1)) compared with AF individuals (46+/-4 beats x min(-1)). When sustained neck suction and pressure were applied to counteract altered carotid sinus pressure during SN and PE administration, isolating the ABR response, the response range remained diminished (P < 0.05) in the HF population (24+/-3 beats x min(-1)) compared with the AF group (41+/-4 beats x min(-1)). During CBR perturbation, the HF (14+/-1 beats-min(-1)) and AF (16+/-1 beats-min(-1)) response ranges were similar. The arterial baroreflex response range was significantly less than the simple sum of the CBR and ABR (HF, 38+/-3 beats x min(-1) and AF, 57+/-4 beats x min(-1)) in both fitness groups. CONCLUSIONS: These data confirm that reductions in arterial-cardiac reflex sensitivity are mediated by diminished ABR function. More importantly, these data suggest that the integrative relationship between the ABR and CBR contributing to arterial baroreflex control of HR is inhibitory in nature and not altered by exercise training.

Baroreflex↗

Ventilatory responses to dynamic exercise elicited by intramuscular sensors.

PURPOSE: Eight subjects, aged 27.0+/-1.6 yr, performed incremental workload cycling to investigate the contribution of skeletal muscle mechano- and metaboreceptors to ventilatory control during dynamic exercise. METHODS: Each subject performed four bouts of exercise: exercise with no intervention (CON); exercise with bilateral thigh cuffs inflated to 90 mm Hg (CUFF); exercise with application of lower-body positive pressure (LBPP) to 45 torr (PP); and exercise with 90 mm Hg thigh cuff inflation and 45 torr LBPP (CUFF+PP). Ventilatory responses and pulmonary gas exchange variables were collected breath-by-breath with concomitant measurement of leg intramuscular pressure. RESULTS: Ventilation (VE) was significantly elevated from CON during PP and CUFF+PP at workloads corresponding to > or = 60% CON peak oxygen uptake (VO2peak) and during CUFF at workloads > or = 80% CON VO2peak, P < 0.05. The VO2 at which ventilatory threshold occurred was significantly reduced from CON (2.17+/-0.28 L x min(-1)) to 1.60+/-0.19 L x min(-1), 1.45+/-0.15 L x min(-1), and 1.15+/-0.11 L x min(-1) during CUFF, PP, and CUFF+PP, respectively. The slope of the linear regression describing the VE/CO2 output relationship was increased from CON by approximately 22% during CUFF, 40% during PP, and 41% during CUFF+PP. CONCLUSIONS: As intramuscular pressure was significantly elevated immediately upon application of LBPP during PP and CUFF+PP without a concomitant increase in VE, it seems unlikely that LBPP-induced increases in VE can be attributed to activation of the mechanoreflex. These findings suggest that LBPP-induced reductions in perfusion pressure and decreases in venous outflow resulting from inflation of bilateral thigh cuffs may generate a metabolite sensitive intramuscular ventilatory stimulus.

Adult↗

Carotid baroreflex function during prolonged exercise.

The present investigation was designed to uncouple the hemodynamic physiological effects of thermoregulation from the effects of a progressively increasing central command activation during prolonged exercise. Subjects performed two 1-h bouts of leg cycling exercise with 1) no intervention and 2) continuous infusion of a dextran solution to maintain central venous pressure constant at the 10-min pressure. Volume infusion resulted in a significant reduction in the decrement in mean arterial pressure seen in the control exercise bout (6.7 +/- 1.8 vs. 11.6+/- 1.3 mmHg, respectively). However, indexes of central command such as heart rate and ratings of perceived exertion rose to a similar extent during both exercise conditions. In addition, the carotid-cardiac baroreflex stimulus-response relationship, as measured by using the neck pressure-neck suction technique, was reset from rest to 10 min of exercise and was further reset from 10 to 50 min of exercise in both exercise conditions, with the operating point being shifted toward the reflex threshold. We conclude that the progressive resetting of the carotid baroreflex and the shift of the reflex operating point render the carotid-cardiac reflex ineffectual in counteracting the continued decrement in mean arterial pressure that occurs during the prolonged exercise.

Adult↗