PubMed HealthSearch

Biomedical subjects

R G Radwin

Publications and source records attributed to R G Radwin.

10 recordsLinked to original sources

Gain effects on performance using a head-controlled computer input device.

The purpose of this study was to use a Fitts' task to (1) determine how control-display gain influences performance using a head-controlled computer input device; (2) compare relative sensitivity to gain and optimal gain between head control and hand/arm control; and (3) investigate control-display gain interactions with other task factors including target width, movement amplitude and direction. The task was a discrete target acquisition task using circular targets of 2.9 mm, 8.1 mm, and 23.5 mm, movement amplitudes of 24.3 mm and 61.7 mm, and eight radial directions including 0 degrees, 45 degrees, 90 degrees, 135 degrees, 180 degrees, 225 degrees, 270 degrees, and 315 degrees. Each device was operated at four gain levels. Ten subjects participated. The results indicated that gain had a significant effect on movement time for both types of pointing devices and exhibited local minimums. Discrete target acquisition at all gains was aptly described using Fitts' Law for both input devices. The mouse gain resulting in minimum movement time and RMS cursor deviation was between 1.0 and 2.0. The minimum movement time and RMS cursor deviation for the head-controlled pointer occurred at a gain between 0.3 and 0.6. Average movement time at the optimal head-controlled pointer gain had a slope of 169 ms/bit and was more than 76% greater than at the optimal mouse gain with a slope of 135 ms/bit. In addition, average RMS displacement was more than 27% greater for the head-controlled pointer at its optimal gain setting than for the mouse. Gain had the greatest effect for small target widths and long movement amplitudes using the head-controlled pointer. Average movement time increased 37% when increasing the head-controlled pointer gain from 0.6 to 1.2 for the small target width, but only increased 0.3% when increasing gain for the large target width. Average movement time also increased 12% when decreasing the head-controlled pointer gain from 0.3 to 0.15 for the long movement amplitude, but decreased 0.3% when decreasing gain for the short movement amplitude.

Ergonomics

External finger forces in submaximal five-finger static pinch prehension.

Small conductive polymer force sensors were attached to the distal phalangeal pads for measuring individual finger forces exerted during submaximal static pinch. A linear force summing strain gauge dynamometer for measuring resultant five-finger pinch force was grasped vertically using a neutral wrist posture. Individual finger forces were measured at fixed total pinch force levels of 10%, 20%, and 30% of maximum voluntary exertion using pinch spans of 45 mm and 65 mm. Total pinch force and individual finger forces were also measured while similarly grasping the dynamometer and supporting fixed weights for 1.0 kg, 1.5 kg, and 2.0 kg loads using pinch spans of 45 mm and 65 mm. The index and middle fingers exerted more than 3 N greater average force than the ring and small fingers for the fixed total pinch force task. No significant individual finger force differences were observed at the 10% maximum voluntary exertion level, however both the index and middle fingers exerted more than 5 N greater force than the ring and small fingers at the 30% maximum voluntary exertion level. The average contribution of the index, middle, ring, and small fingers were 33%, 33%, 17%, and 15%, respectfully, for the fixed total pinch force task. As exertion level increased from 10% to 30%, the contribution of the middle finger was not constant increasing from 25% to 38%. Total pinch force increased from 15 N to 30 N when the load weight increased from 1.0 kg to 2.0 kg.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent

Maximal dynamic range electrotactile stimulation waveforms.

A new method to measure the dynamic range of electrotactile (electrocutaneous) stimulation uses both steepest ascent (gradient) and one-variable-at-a-time methods to determine the waveform variables that maximize the subjective magnitude (intensity) of the electrotactile percept at the maximal current without discomfort for balanced-biphasic pulse bursts presented at a 15-Hz rate. The magnitude at the maximal current without discomfort is maximized by the following waveform (range tested in parentheses): number of pulses/burst = 6 (1-20), pulse repetition rate within a burst = 350 Hz (200-1500), and phase width = 150 microseconds (40-350). The interphase interval (separation between positive and negative phases in a biphasic pulse) does not affect dynamic range from 0-500 microseconds. The number of pulses/burst has a large effect on the perceived dynamic range when this is measured using a subjective-magnitude-based algorithm, whereas it has little effect on the traditional dynamic range measure, i.e., (maximal current without discomfort)/(sensation threshold current). The perceived stimulus magnitude at the maximal current without discomfort is approximately twice as strong with 6 pulses/burst as it is with 1 pulse/burst (a frequently-used waveform).

Bias

A conductive polymer sensor for measuring external finger forces.

This paper describes the construction and use of a durable and thin force sensor that can be attached to the palmar surface of the fingers and hands for studying the biomechanics of grasp and for use in hand injury rehabilitation. These force sensors were constructed using a modified commercially available conductive polymer pressure sensing element and installing an epoxy dome for directing applied forces through a 12 mm diameter active sensing area. The installation of an epoxy dome was effective for making the sensors insensitive to contact surfaces varying from 25 to 1100 mm2 and a 16 mm radius surface curved convex towards the finger. The completed sensors were only 1.8 mm thick and capable of being taped to the distal phalangeal finger pads. They were calibrated on the hand by pinching a strain gage dynamometer. The useful range was between 0 and 30 N with an accuracy of 1 N for both static loading and normal dynamic grasp activities. The sensor time constant was 0.54 ms for a step force input. Because of varying offset voltages every time the sensors were attached, these sensors should be calibrated on the hand before each use. The sensors were used for measuring finger forces during controlled pinching and lifting tasks, and during ordinary grasping activities, such as picking up a book or a box, where the useful force range and response for these sensors were adequate.

Biomechanical Phenomena

Ridge detection tactility deficits associated with carpal tunnel syndrome.

A ridge detection threshold task was administered to patients diagnosed as having carpal tunnel syndrome for studying performance in an occupationally relevant functional tactile inspection task. Thresholds were compared with a reference group of subjects not having carpal tunnel syndrome symptoms, performing the same task. The threshold detection task used the method of limits for studying the effects of carpal tunnel syndrome, rate of ridge height changes, ridge gradient, and direction of shearing against the skin on ridge detection thresholds for a repeated measures factorial experimental design. Sixteen carpal tunnel syndrome hands and 30 normal hands were studied. Average ridge detection threshold was 0.08 mm for the normal subjects and increased to 0.20 mm for the carpal tunnel syndrome subjects. No significant age effect was observed. These results suggest that workers having carpal tunnel syndrome may not detect an edge or surface defect in a tactile inspection task unless it was more than twice as high as detected by workers without CTS.

Adult

A 16-channel 8-parameter waveform electrotactile stimulation system.

We have developed a general-purpose electrotactile (electrocutaneous) stimulation system as a research tool for studying psychophysiological performance associated with various stimulation waveforms. An experimenter-defined command file specifies the stimulation current and waveform of each of the 16 channels. The system provides burst onset delay of 0-20 ms, phase current of 0-50 mA, interphase interval of 0-1000 microseconds, number of pulses per burst from 1-100, pulse repetition rate of 0.1-25 kHz, phase width of 2-1000 microseconds, and functionally-monophasic pulses (with zero dc current) or balanced-biphasic pulses (with equal positive and negative phases). The system automatically delivers the desired stimulation, prompts the subject for responses, and then logs subject responses. Key features of the system are 1) very flexible choice of bursts of pulsatile waveforms, 2) real-time control of all of the waveform parameters as mathematical functions of external analog inputs, and 3) high-performance electrode-driver circuitry.

Electric Stimulation

Vibration exposure for selected power hand tools used in automobile assembly.

A practical method for assessing vibration exposure for workers operating vibrating hand tools on an automobile assembly line is presented. Vibration exposure is difficult to assess directly using many fast Fourier transform (FFT) spectral analyzers because of long task cycle times. Exposure time cannot be accurately estimated using time standards because of the high variability between operators and work methods. Furthermore, because workers frequently move about and get into inaccessible spaces, it is difficult to record vibration without interfering with the operation. A work sampling method was used for determining vibration exposure time by attaching accelerometers to the tools and suspending a battery-operated digital data logger from the air hose. Vibration acceleration and frequency spectra for each tool were obtained off-line replicating actual working conditions and analyzed together with exposure time data for determining individual worker vibration exposure. Eight pneumatic vibrating power hand tools, representing tools commonly used in an automobile assembly plant, were studied. Spectra for the rotary and reciprocating power tools and had large distinct dominant fundamental frequencies occurring in a narrow frequency range between 35 Hz and 150 Hz. These frequencies corresponded closely to tool free-running speeds, suggesting that major spectral component frequencies may be predicted on the basis of speed for some tools.

Automobiles

A method for evaluating head-controlled computer input devices using Fitts' law.

The discrete movement task employed in this study consisted of moving a cursor from the center of a computer display screen to circular targets located 24.4 and 110.9 mm in eight radial directions. The target diameters were 2.7, 8.1, and 24.2 mm. Performance measures included movement time, cursor path distance, and root-mean-square cursor deviation. Ten subjects with no movement disabilities were studied using a conventional mouse and a lightweight ultrasonic head-controlled computer input pointing device. Average movement time was 306 ms greater (63%) for the head-controlled pointer than for the mouse. The effect of direction on movement time for the mouse was relatively small compared with the head-controlled pointer, which was lowest at 90 and 270 deg, corresponding to head extension and head flexion, respectively. Average path distance and root mean square displacement was lowest at off-diagonal directions (0, 90, 180, and 270 deg). This methodology was also shown to be useful for evaluating performance using an alternative head-controlled input device for two subjects having cerebral palsy, and measured subtle performance improvements after providing a disabled subject with lateral torso support.

Adult

Muscle response to pneumatic hand tool torque reaction forces.

Surface electromyography was used for studying the effects of torque reaction force acting against the hand, on forearm muscle activity and grip force for five subjects operating right angle, air shut-off nutrunners. Four tools having increasing spindle torque were operated using short and long torque reaction times. Nutrunner spindle torque ranged between 30 Nm and 100 Nm. Short torque reaction time was considered 0.5 s while long torque reaction time was 2 s. Peak horizontal force was the greatest component of the reaction force acting against the hand and accounted for more than 97% of the peak resultant hand force. Peak hand force increased from 89 N for the smallest tool to 202 N for the largest tool. Forearm muscle rms EMG, scaled for grip force, indicated average flexor activity during the Torque-reaction phase was more than four times greater than the Pre-start and Post Shut-off phases, and two times greater than the Run-down phase. Flexor EMG activity during the Torque-reaction phase increased for increasing tool peak spindle torque. Average flexor rms EMG activity, scaled for grip force, during the Torque-reaction phase increased from 372 N for the 30 Nm nutrunner to 449 N for the 100 Nm nutrunner. Flexor rms EMG activity averaged during the Torque-reaction phase and scaled for grip force was 390 N for long torque reaction times and increased to 440 N for short torque reaction times. Flexor rms EMG integrated over the torque reaction phase was 839 Ns for long torque reaction times and decreased to 312 Ns for short torque reaction times. The average latency between tool spindle torque onset and peak initial flexor rms EMG for long torque reaction times was 294 ms which decreased to 161 ms for short torque reaction times. The average latency between peak tool spindle torque, just prior to tool shut-off, and peak final rms EMG for long torque reaction times was 97 ms for flexors and 188 ms for extensors, which decreased for short torque reaction times to 47 ms for flexors and 116 ms for extensors. The results suggest that right angle nutrunner torque reaction forces can affect extrinsic hand muscles in the forearm, and hence grip exertions, by way of a reflex response.(ABSTRACT TRUNCATED AT 400 WORDS)

Adult

Ergonomics and the effects of vibration in hand-intensive work.

Along with ergonomic factors, such as forceful and repeated exertion and certain postures, vibration has been cited as a factor of chronic nerve and tendon disorders such as carpal tunnel syndrome and tendinitis. The arguments for the contribution of vibration come from epidemiologic studies, clinical case analyses, and studies of short-term effects. It is well established that vibration stimulates muscle contraction, which is called the tonic vibration reflex. It is also known that vibration reduces tactility and that tactility affects the amount of force exerted to hold or manipulate a given object. For localized vibration exposure of the hand and arm to occur, the hand must grip a vibrating object. Vibration may increase the risk of chronic tendon and nerve disorders by increasing the force exerted in repetitive manual tasks. This close relationship between force and vibration, and difficulties in measuring force and vibration in manual work, makes it very difficult to determine their relative contributions in epidemiologic and clinical studies.

Carpal Tunnel Syndrome