PubMed Health⌕ Search

Biomedical subjects

R G Sextro

Publications and source records attributed to R G Sextro.

12 recordsLinked to original sources

What is an effective portable air cleaning device? A review.

The use of portable air cleaning devices in residential settings has been steadily growing over the last 10 years. Three out of every 10 households now contain a portable air cleaning device. This increased use of air cleaners is accompanied by, if not influenced by, a fundamental belief by consumers that the air cleaners are providing an improved indoor air environment. However, there is a wide variation in the performance of air cleaners that is dependent on the specific air cleaner design and various indoor factors. The most widely used method in the United States to assess the performance of new air cleaners is the procedure described in the American National Standards Institute (ANSI)/Association of Home Appliance Manufacturers (AHAM) AC-1-2002. This method describes both the test conditions and the testing protocol. The protocol yields a performance metric that is based on the measured decay rate of contaminant concentrations with the air cleaner operating compared with the measured decay rate with the air cleaner turned off. The resulting metric, the clean air delivery rate (CADR), permits both an intercomparison of performance among various air cleaners and a comparison of air cleaner operation to other contaminant removal processes. In this article, we comment on the testing process, discuss its applicability to various contaminants, and evaluate the resulting performance metrics for effective air cleaning.

Air Pollution, Indoor↗

Pollutant dispersion in a large indoor space: Part 1 -- Scaled experiments using a water-filled model with occupants and furniture.

Scale modeling is a useful tool for analyzing complex indoor spaces. Scale model experiments can reduce experimental costs, improve control of flow and temperature conditions, and provide a practical method for pretesting full-scale system modifications. However, changes in physical scale and working fluid (air or water) can complicate interpretation of the equivalent effects in the full-scale structure. This paper presents a detailed scaling analysis of a water tank experiment designed to model a large indoor space, and experimental results obtained with this model to assess the influence of furniture and people in the pollutant concentration field at breathing height. Theoretical calculations are derived for predicting the effects from losses of molecular diffusion, small scale eddies, turbulent kinetic energy, and turbulent mass diffusivity in a scale model, even without Reynolds number matching. Pollutant dispersion experiments were performed in a water-filled 30:1 scale model of a large room, using uranine dye injected continuously from a small point source. Pollutant concentrations were measured in a plane, using laser-induced fluorescence techniques, for three interior configurations: unobstructed, table-like obstructions, and table-like and figure-like obstructions. Concentrations within the measurement plane varied by more than an order of magnitude, even after the concentration field was fully developed. Objects in the model interior had a significant effect on both the concentration field and fluctuation intensity in the measurement plane. PRACTICAL IMPLICATION: This scale model study demonstrates both the utility of scale models for investigating dispersion in indoor environments and the significant impact of turbulence created by furnishings and people on pollutant transport from floor level sources. In a room with no furniture or occupants, the average concentration can vary by about a factor of 3 across the room. Adding furniture and occupants can increase this spatial variation by another factor of 3.

Air Movements↗

Pollutant dispersion in a large indoor space. Part 2: Computational fluid dynamics predictions and comparison with a scale model experiment for isothermal flow.

UNLABELLED: This paper reports on an investigation of the adequacy of computational fluid dynamics (CFD), using a standard Reynolds Averaged Navier-Stokes (RANS) model, for predicting dispersion of neutrally buoyant gas in a large indoor space. We used CFD to predict pollutant (dye) concentration distribution in a water-filled scale model of an atrium with a continuous pollutant source in the absence of furniture and occupants. Predictions from the RANS formulation are comparable with an ensemble average of independent identical experiments. Model results were compared with pollutant concentration data in a horizontal plane from experiments in a scale model atrium. Predictions were made for steady-state (fully developed) and transient (developing) pollutant concentrations. Agreement between CFD predictions and ensemble averaged experimental measurements is quantified using the ratios of CFD-predicted and experimentally measured dye concentration at a large number of points in the measurement plane. Agreement is considered good if these ratios fall between 0.5 and 2.0 at all points in the plane. The standard k-epsilon two-equation turbulence model obtains this level of agreement and predicts pollutant arrival time to the measurement plane within a few seconds. These results suggest that this modeling approach is adequate for predicting isothermal pollutant transport in a large room with simple geometry. PRACTICAL IMPLICATIONS: CFD modeling of pollutant transport is becoming increasingly common but high quality comparisons between CFD and experiment remain rare. Our results provide such a comparison. We demonstrate that the standard k-epsilon model provides good predictions for both transient and fully developed pollutant concentrations for an isothermal large space where furnishings are unimportant. This model is less computationally intensive than a large eddy simulation or low Reynolds number k-epsilon model.

Air Movements↗

Responding to sudden pollutant releases in office buildings: 1. Framework and analysis tools.

We describe a framework for developing response recommendations to unexpected toxic pollutant releases in commercial buildings. It may be applied in conditions where limited building- and event-specific information is available. The framework is based on a screening-level methodology to develop insights, or rules-of-thumb, into the behavior of airflow and pollutant transport. A three-stage framework is presented: (1). develop a building taxonomy to identify generic, or prototypical, building configurations; (2). characterize uncertainty and conduct simulation modeling to predict typical airflow and pollutant transport behavior; and (3). rank uncertainty contributions to determine how information obtained at a site might reduce uncertainties in the model predictions. The approach is applied to study a hypothetical pollutant release on the first floor of a five-story office building. Key features that affect pollutant transport are identified and described by value ranges in the building stock. Simulation modeling provides predictions and uncertainty estimates of time-dependent pollutant concentrations, following a release, for a range of indoor and outdoor conditions. In this exercise, we predict concentrations on the fifth floor to be an order of magnitude less than on the first, coefficients of variation greater than 2, and information about the HVAC operation and window position most reducing uncertainty in predicted peak concentrations.

Air Movements↗

Radon entry into houses: the importance of scale-dependent permeability.

Soil permeability to air can increase substantially with measurement length scale. We tested the hypothesis that the scale effect could resolve large model underpredictions of radon and soil-gas entry into two experimental basement structures located in natural sandy-loam soil at a field site in Ben Lomond, CA. Previously, the model input for permeability at the site had been assessed based on 0.5-m scale measurements. After determining the soil-structure interaction scale (system scale) to be approximately 3 m, the model input was changed to reflect 3-m scale permeability measurements. This adjustment reduced unacceptably large model underpredictions, of a factor of 3 to 5, to a range near that of acceptable experimental error, 20 to 40%. The permeability scale effect may explain large and persistent model underestimates of radon entry into real houses. The results argue strongly for determining permeability at a length scale consistent with that of the system under study.

Air Pollution, Indoor↗

The influence of a subslab gravel layer and open area on soil-gas and radon entry into two experimental basements.

Measurements of steady-state soil-gas and 222Rn entry rates into two room-sized experimental basement structures were made for a range of structure depressurizations (0-40 Pa) and open floor areas (0-165 x 10(-4) m2). The structures are identical except that in one the floor slab lies directly on native soil whereas in the other the slab lies on a high-permeability gravel layer. The subslab gravel layer greatly enhances the soil-gas and radon entry rate into the structure. The radon entry rate into the structure with the subslab gravel layer is four times greater than the entry rate into the structure without the gravel layer with an open floor area of 165 x 10(-4) m2; however the ratio increases to 30 for an open floor area of 5.0 x 10(-4) m2. The relationship between open area and soil-gas entry rate is complex. It depends on both the amount and distribution of the open area as well as the permeability of the soil near the opening. The entry rate into the experimental structures is largely determined by the presence or absence of a subslab gravel layer. Therefore open area is a poor indicator of radon and soil-gas entry into the structures. The extension of the soil-gas pressure field created by structure depressurization is a good measure of the radon entry. The measured normalized radon entry rate into both structures has the same linear relationship with the average subslab pressure coupling is an estimate of the extension of the soil-gas pressure field. A three-dimensional finite-difference model correctly predicts the effect of a subslab gravel layer and different open area configurations on radon and soil-gas entry rate; however, the model underpredicts the absolute entry rate into each structure by a factor of 1.5.

Air Pollution, Indoor↗

Modeling radon entry into Florida slab-on-grade houses.

Radon entry into a Florida house whose concrete slab is supported by a permeable concrete-block stem wall and a concrete footer is modeled. The slab rests on backfill material; the same material is used to fill the footer trench. A region of undisturbed soil is assumed to extend 10 m beyond and below the footer. The soil is assumed homogeneous and isotropic except for certain simulations in which soil layers of high permeability or radium content are introduced. Depressurization of the house induces a pressure field in the soil and backfill. The Laplace equation, resulting from Darcy's law and the continuity equation, is solved using a steady-state finite-difference model to determine this field. The mass-transport equation is then solved to obtain the diffusive and advective radon entry rates through the slab; the permeable stem wall; gaps at the intersections of the slab, stem wall, and footer; and gaps in the slab. These rates are determined for variable soil, backfill, and stem-wall permeability and radium content, slab-opening width and position, slab and stem-wall diffusivity, and water table depth. The variations in soil permeability and radium content include cases of horizontally stratified soil. We also consider the effect of a gap between the edge of the slab and the stem wall that restricts the passage of soil gas from the stem wall into the house. Calculations indicate that the total radon entry rate is relatively low unless the soil or backfill permeability or radium content is high. Variations in most of the factors, other than the soil permeability and radium content, have only a small effect on the total radon entry rate. However, for a fixed soil permeability, the total radon entry rate may be reduced by a factor of 2 or more by decreasing the backfill permeability, by making the stem wall impermeable and gap-free, (possibly by constructing a one-piece slab/stem-wall/footer), or by increasing the pressure in the interior of the stem wall (by ensuring that there is a large pressure drop across the slab/stem-wall gap), thereby reducing radon entry into the wall from the soil. Use of an impermeable stem wall and a low-permeability fill in combination is predicted to reduce the radon entry rate by 71%.

Air Pollution, Indoor↗

Effectiveness of radon control techniques in fifteen homes.

Radon control systems were installed and evaluated in fourteen homes in the Spokane River Valley/Rathdrum Prairie and in one home in Vancouver, Washington. Because of local soil conditions, subsurface ventilation (SSV) by pressurization was always more effective in these houses than SSV by depressurization in reducing indoor radon levels to below guidelines. Basement overpressurization was successfully applied in five houses with airtight basements where practical-sized fans could develop an overpressure of 1 to 3 Pascals. Crawlspace ventilation was more effective than crawlspace isolation in reducing radon entry from the crawlspace, but had to be used in conjunction with other mitigation techniques, since the houses also had basements. Indoor radon concentrations in two houses with air-to-air heat exchangers (AAHX) were reduced to levels inversely dependent on the new total ventilation rates and were lowered even further in one house where the air distribution system was modified. Sealing penetrations in the below-grade surfaces of substructures was relatively ineffective in controlling radon. Operation of the radon control systems (except for the AAHX's) made no measureable change in ventilation rates or indoor concentrations of other measured pollutants. Installation costs by treated floor area ranged from approximately $4/m2 for sealing to $28/m2 for the AAHX's. Based on the low electric rates for the region, annual operating costs for the active systems were estimated to be approximately $60 to $170.

Air Pollution, Radioactive↗

Characterizing the occurrence, sources, and variability of radon in Pacific Northwest homes.

A compilation of data from earlier studies of 172 homes in the Pacific Northwest indicated that approximately 65 percent of the 46 homes tested in the Spokane River Valley/Rathdrum Prairie region of eastern Washington/northern Idaho had heating season indoor radon (222Rn) concentrations above the U. S. EPA guideline of 148 Bq m-3 (4 pCi L-1). A subset of 35 homes was selected for additional study. The primary source of indoor radon in the Spokane River Valley/Rathdrum Prairie was pressure-driven flow of soil gas containing moderate radon concentrations (geometric mean concentration of 16,000 Bq m-3) from the highly permeable soils (geometric mean permeability of 5 x 10(-11) m2) surrounding the house substructures. Estimated soil gas entry rates ranged from 0.4 to 39 m3h-1 and 1 percent to 21 percent of total building air infiltration. Radon from other sources, including domestic water supplies and building materials was negligible. In high radon homes, winter indoor levels averaged 13 times higher than summer concentrations, while in low radon homes winter levels averaged only 2.5 times higher. Short-term variations in indoor radon were observed to be dependent upon indoor-outdoor temperature differences, wind speed, and operation of forced-air furnace fans. Forced-air furnace operation, along with leaky return ducts and plenums, and openings between the substructure and upper floors enhanced mixing of radon-laden substructure air throughout the rest of the building.

Air Pollutants↗

Developing soil gas and 222Rn entry potentials for substructure surfaces and assessing 222Rn control diagnostic techniques.

Research-based procedures for characterizing the causes of elevated indoor 222Rn levels and guiding the selection of an appropriate control technique were evaluated at seven New Jersey houses. Procedures such as thorough visual inspections, blower door air leakage tests, pressure field mapping, subsurface vacuum extension tests, sampling of 222Rn concentrations throughout the substructure, and measurements of the additional depressurization caused by various appliances all were found to furnish important information to the mitigation contractor or researcher. An analysis of data from these and other diagnostic techniques performed at the seven houses also indicated: (1) regions of very high permeability existed directly adjacent to the exterior of substructure walls and floors; (2) the additional substructure depressurization caused by operation of forced-air furnaces and attic exhaust fans could exceed 1 Pascal; (3) 222Rn concentrations below basement slabs and slabs-on-grade adjoining below grade basement walls were approximately seven times higher than those within block wall cavities; and (4) air leakage areas of crawlspace and basement ceilings were quite large, ranging up to 0.15 m2. The pressure field mapping tests identified the areas surrounding the substructure that were well coupled to the indoors. Using flow, pressure difference, and 222Rn concentration data, indices of soil gas entry potential and 222Rn entry potential were developed to indicate the areas of the substructure that may have high entry rates of soil gas and 222Rn, respectively. These indices could be helpful for quantifying the relative resistance to soil gas movement of substructure surfaces and surrounding soils and for determining the placement of 222Rn control systems.

Air Pollutants↗

Potable water as a source of airborne 222Rn in U.S. dwellings: a review and assessment.

Using a long-term-average, single-cell model and available data for U.S. housing, the concentration of 222Rn in indoor air due to the use of potable water is assessed. The ratio of the airborne 222Rn concentration to the concentration in water is represented by a lognormal distribution with geometric mean and geometric standard deviation of 0.65 X 10(-4) and 2.88, respectively, in fair agreement with the previously reported results of direct measurements of the ratio in 13 houses. By combining this result with data on 222Rn concentrations in U.S. water supplies, potable water is estimated to contribute an average of 24, 1.3, and 0.1 Bq m-3 to the airborne 222Rn concentration in residences served by private wells, public ground water, and surface water supplies, respectively.

Air Pollutants↗

Characterizing the sources, range, and environmental influences of radon 222 and its decay products.

Recent results from our group directly assist efforts to identify and control excessive concentrations of radon 222 and its decay products in residential environments. We have demonstrated directly the importance of pressure-induced flow of soil gas for transport of radon from the ground into houses. Analysis of available information from measurements of concentrations in U.S. homes has resulted in a quantitative appreciation of the distribution of indoor levels, including the degree of dependence on geographic location. Experiments on the effectiveness of air cleaning devices for removal of particles and radon decay products indicate the potential and limitations of this approach to control.

Construction Materials↗