Peritoneal function tests: usefulness of simplified methods.

The Peritoneal Equilibration Test (PET) as standardized by Twardowski (T) and simplified Mass Transfer Coefficients (MTC) as per Garred (G) and Krediet (K) have been employed in our patients to assess: 1) the reproducibility of results, 2) correlation between methods, and 3) usefulness of patient categorization by simplified methods in contrast to PET patterns. We have performed 29 standardized PET (Dianeal 2.5%) in 24 stable CAPD patients. We have collected dialysate samples at 0, 30, 60, 120, 180 and 240 minutes. With this data we were able to calculate the dialysate/plasma ratio for PET, MTC as per Garred and MTC as per Krediet. Our results were not significantly different from data reported by the original authors, except for PET D/P urea at 240': 0.91 +/- 0.07(T) vs. 0.87 +/- 0.08 (our), p < 0.05. In our patients, good correlation was found between PET and MTC for urea, creatinine, and glucose, using both formulae (G and K). Patient categorization as High, High Average, Low Average, and Low by MTCs can well predict PET categorization with acceptable sensitivity and good specificity. We conclude there is good reproducibility of the methods. There is also a close correlation between PET, K and G methods for solute transport evaluation and patient categorization. Simplified methods can be substituted for the more complex ones.

Adolescent

Evaluation of the Chem 1 analyzer.

The selective multitest Technicon Chem 1 analyser was evaluated according to the guidelines of the 'Comisión de Instrumentación de la Sociedad Española de Química Clínica', and the protocols of the 'European Committee for Clinical Laboratory Standards' and 'Commission de validation de techniques' of the 'Société Française de Biologie Clinique'. The evaluation was performed in three steps: evaluation in routine conditions, assessment of the interferences and study of practicability. Under routine working conditions, eighteen constituents were studied. Within-run imprecision ranged from 0.6% (CV) for gamma-GT to 4.7% (CV) for AST. Between-run imprecision ranged from 1.6% (CV) for ion sodium to 5.5% (CV) for creatinine. Specimen related carry-over was not within the samples; specimen independent carry-over was found in some of the constituents studied. The relative inaccuracy is good for all the constituents assayed. Haemoglobin (290 mumol.l1) showed a positive interference with urate at three concentration levels (low, medium and high). Bilirubin (up to 300 mumol.l-1) caused a negative interference with creatinine at three concentration levels. Turbidity (trigliceride up to 4 mumol.l-1) stated a positive interference with creatinine at three concentration levels and with AST at two concentration levels (low and medium). Turbidity also caused a negative interference with urate at three concentration levels and with urea at two concentration levels (low and medium).

Automation