PubMed Health⌕ Search

Biomedical subjects

R Gil

Publications and source records attributed to R Gil.

At least 91 records · Page 5Linked to original sources

Usefulness of three-dimensional reconstruction for interpretation and quantitative analysis of intracoronary ultrasound during stent deployment.

We examined 49 coronary stents in 33 patients after angiographically guided optimization of the deployment by intracoronary ultrasound, and compared the findings of a conventional 2-dimensional analysis approach with the results obtained from an automatic lumen recognition provided by a 3-dimensional reconstruction system. The automatic lumen analysis demonstrated that only 15 stents (31%) fulfilled defined ultrasound criteria of adequate stent deployment, and that 5 of these cases were missed by the conventional approach, which systematically overestimated the dimensions of the minimal stent lumen.

Angioplasty, Balloon, Coronary↗

Usefulness of on-line three-dimensional reconstruction of intracoronary ultrasound for guidance of stent deployment.

The additional information provided by automated on-line 3-dimensional (3-D) reconstruction of intracoronary ultrasound (ICUS) was assessed in 42 patients (62 stents) who underwent stent deployment after achieving an optimal quantitative angiographic result. In 10 of 42 patients, 3-D ICUS was also performed before stenting. ICUS images of stents and adjacent reference segments were acquired by using a motorized pullback at a constant speed (1 mm/s) and immediately processed in the catheterization laboratory. Optimal stent expansion was detected by 3-D ICUS in case of complete apposition of stent struts to the vessel wall. Furthermore, an attempt was made to maximize the intrastent lumen area to match lumen area of the reference segment and to cover with stents all the segments with residual significant lesions (plaque burden >50%). Three-dimensional automated reconstruction of ICUS was successful in 8 of 10 patients (80%) before, and in 36 of 42 patients (86%) after stent deployment. In all 8 patients who underwent successful 3-D ICUS assessment before stent implantation, the selection of stent length was facilitated by accurately measuring the lesion length. After stenting, 3-D ICUS modified the management strategy in 21 of 36 patients (58%), triggering additional high-pressure dilatations in 13 patients (36%) and additional stent deployment in 8 (22%). In conclusion, on-line 3-D ICUS facilitates stent selection and strongly modifies the revascularization strategy by accurately detecting stent underexpansion and presence of uncovered lesions.

Aged↗

Impact of plaque morphology and composition on the mechanisms of lumen enlargement using intracoronary ultrasound and quantitative angiography after balloon angioplasty.

Limited information is provided by angiography on plaque morphology and composition before balloon angioplasty. Identification of plaques associated with reduced lumen gain or a high complication rate may provide the rationale for using alternative revascularization devices. We studied 60 patients with quantitative angiography and intracoronary ultrasound (ICUS) before and after balloon dilation. Angiography was used to measure transient wall stretch and elastic recoil. ICUS was used to investigate the mechanisms of lumen enlargement among different plaque compositions and in the presence of a disease-free wall (minimal thickness < or = 0.6 mm). Compared with ultrasound, angiography underestimated the presence of vessel calcification (13% vs 78%), lumen eccentricity (35% vs 62%), and wall dissection (32% vs 57%). ICUS measurements showed that balloon angioplasty increased lumen area from 1.82 +/- 0.51 to 4.81 +/- 1.43 mm2. Lumen enlargement was the result of the combined effect of an increase in the total cross-sectional area of the vessel (wall stretching, 43%) and of a reduction in the area occupied by the plaque (plaque compression or redistribution, 57%). Vessels with a disease-free wall had smaller lumen gain than other types of vessels (2.13 +/- 1.26 vs 3.59 +/- mm2, respectively, p < 0.01). Wall stretching was the most important mechanism of lumen enlargement in vessels with a disease-free wall (79% vs 37% in the other vessels). Angiography revealed a direct correlation between temporary stretch and elastic recoil that was responsible for 26% of the loss of the potential lumen gain. Thus, lumen enlargement after balloon angioplasty is the combined result of wall stretch and plaque compression or redistribution. ICUS indicates that vessels with a remnant arc of disease-free wall are dilated mainly by wall stretching compared with other types of vessels and are associated with a smaller lumen gain.

Aged↗

A novel cell wall protein specific to the mycelial form of Yarrowia lipolytica.

A cDNA clone specifying a cell wall protein was isolated from a Yarrowia lipolytica cDNA library. The cDNA library was constructed in the expression vector lambda gt 11, with the RNA isolated from actively growing mycelial cells. The deduced amino acid sequence shows that the encoded protein contains an N-terminal hydrophobic signal peptide. We have designated this protein YWP1 for Yarrowia lipolytica cell Wall Protein. Northern hybridization identified YWP1 transcript only when Y. lipolytica was growing in the mycelial form. The encoded protein seems to be covalently bound to the glucan cell wall since it is not released from the cell walls by sodium dodecyl sulphate extraction, but it is solubilized following partial degradation of beta-glucan by Zymolyase digestion. The protein is localized in the outer surface on the tip of the growing mycelial cells and is found partially cryptic in sub-apical locations, suggesting that it participates directly in the mycelial wall architecture.

Amino Acid Sequence↗

Utilization of translesional hemodynamics: comparison of pressure and flow methods in stenosis assessment in patients with coronary artery disease.

Aim of this study is the assessment of feasibility and clinical usefulness of a new index of stenosis severity, the slope of the instantaneous transstenotic pressure gradient/velocity relationship. Twenty-one patients scheduled for percutaneous revascularization procedures were studied with simultaneous measurement of poststenotic coronary pressure and flow velocity, in basal condition and during maximal hyperemia induced with intracoronary papaverine. Reliable measurements of the transstenotic pressure gradient/velocity relationship could be obtained in 11 patients. In 64% of the cases, a quadratic equation showed the best fit for the data. Steeper increases of the transstenotic pressure gradient at any given velocity increase were observed in the lesions with the smallest cross-sectional area measured with quantitative angiography. A comparison of this new index with coronary flow reserved, maximal hyperemic velocity, stenosis flow reserve derived from quantitative angiography, basal and hyperemic transstenotic pressure gradient and fractional flow reserve is presented and the relative merits of all these parameters are discussed. This pilot experience suggests that the instantaneous relationship between pressure gradient and flow velocity changes during the cardiac cycle can accurately characterize the stenosis hemodynamics in the catheterization laboratory.

Adult↗

Optimized expansion of the Wallstent compared with the Palmaz-Schatz stent: on-line observations with two- and three-dimensional intracoronary ultrasound after angiographic guidance.

Optimized stent expansion by high-pressure inflations of oversized balloons has initially been derived from experience obtained with the Palmaz-Schatz stent, whereas there is little experience with this strategy in the Wallstent. By using this approach with quantitative coronary angiographic guidance, 20 Wallstents and 20 Palmaz-Schatz stents were implanted in 34 patients and consecutively examined by conventional two-dimensional (2D) intracoronary ultrasound (ICUS) and three-dimensional (3D) ICUS on the basis of the application of a pattern recognition algorithm. Ultrasound criteria of adequate stent expansion were defined as a complete apposition of the stent to the vessel wall, a stent symmetry index (SSI = minimum/maximum lumen diameter) > or = O.7, and a stent-reference lumen area ratio (SRR = Minimum intrastent lumen area/Average of proximal and distal reference lumen area) > or = O.8. In all cases a smooth angiographic lumen and a negative diameter stenosis, on the basis of a distal reference, was achieved. For the Wallstents ICUS showed a higher SSI (2D, 0.95 +/- 0.04 vs 0.85 +/- 0.09; p < 0.001; 3D, 0.90 +/- 0.09 vs 0.82 +/- 0.11, p < 0.05) and a lower SRR (2D, 0.66 +/- 0.12 vs 0.81 +/- 0.13, p < 0.005; 3D, 0.63 +/- 0.14 vs 0.74 +/- 0.15, p < 0.05) than for the Palmaz-Schatz stents. Ninety percent of failure in meeting these criteria resulted from a low SRR. The incidence of incomplete stent apposition (one in both stents) or SSI <0.7 was low and generally associated with an SRR <0.8. The Wallstents met the ICUS criteria less often (2D, 2(1O%) vs 10(50%), p < 0.01; 3D, 3(15%) vs 9(45%), p < 0.05), were significantly longer (35.1 +/- 7.7 mm and 14.3 +/- 3.3 mm, p < 0.0001), and generally demonstrated a larger vessel tapering, measured as proximal minus distal ICUS reference lumen area (1.33 +/- 2.91 mm2 vs 0.44 +/- 1.97 mm(2), not significant). Wallstents meeting the ICUS criteria, however, showed less vessel tapering (0.18 +/- 1.64 mm(2)). Thus optimized stent expansion was followed by excellent angiographic results for both Palmaz-Schatz and Wallstent. Although angiographic results and visual assessment of the ICUS examination suggested a good outcome, few Wallstents met the ICUS criteria in contrast to the Palmaz-Schatz stents. The low value of the SRR in the Wallstents is likely to be caused by vessel tapering, suggesting that this criterion may be unsuitable in assessing the adequacy of the expansion of relatively long stents such as the Wallstent.

Aged↗

Three-dimensional intracoronary ultrasound imaging. Methodology and clinical relevance for the assessment of coronary arteries and bypass grafts.

Three-dimensional (3-D) reconstruction of intracoronary ultrasound (ICUS) images has an increasing application as the applicability of systems of on-line analysis provides a superior guidance by coupling the advantages of a high-resolution cross-sectional imaging with an overview of stenosis and reference segments. Detection of the external contour of the vessel which is a prerequisite for measurements of coronary plaques is currently not provided by the algorithms for automated on-line analysis. Thus, off-line reconstruction is required for studies aiming at the assessment of progression/regression of atherosclerosis and of mechanisms of interventions or restenosis. Various 3-D reconstruction methods with specific advantages and limitations are able to meet the different requirements concerning applicability, quality of visualization, and accuracy of quantification. The use of 3-D ICUS in the assessment of cardiac transplant recipients permits a more reliable and accurate quantification of intimal hyperplasia as seen in cardiac allograft arteriopathy. In patients undergoing bypass surgery it may influence the therapeutic decision, since it allows to determine the longitudinal extent of calcification and frequently discovers atherosclerosis in angiographically normal segments. Vessel stenoses both of native coronary arteries and bypass grafts can be studied by 3-D ICUS and additional information can be obtained during catheter based interventions. Despite some remaining technical limitation 3-D reconstruction of ICUS images has the potential of becoming a practical tool to simplify the interpretation and quantification of ICUS images.

Algorithms↗

Quantitative assessment with intracoronary ultrasound of the mechanisms of restenosis after percutaneous transluminal coronary angioplasty and directional coronary atherectomy.

The mechanisms of immediate and late changes after percutaneous transluminal coronary angioplasty (PTCA) and directional coronary atherectomy (DCA) were assessed by serial ultrasound imaging in 18 patients treated with PTCA and 16 treated with DCA before, immediately after, and 6 months after coronary interventions. A reduction in plaque area was the main operative mechanism of DCA, explaining 66% of lumen enlargement. In the PTCA group, the increase in lumen area was the result of a more balanced combination of plaque reduction (52% of lumen increase) and increase in total lumen area (48%); p < 0.05 versus DCA. In the PTCA group, this last mechanism was prevalent (p < 0.05) in the lesions showing wall fracture or dissection after treatment and in the lesions with a mixed or calcific composition. In the PTCA group, concentric lesions showed a greater plaque compression than eccentric lesions (p < 0.02). Plaque increase was responsible for 92% and 32% of the late lumen loss after DCA and after PTCA, respectively (p < 0.05). In PTCA patients, a chronic reduction in total vessel area was the main operative mechanism of lumen reduction (67%) and was prevalent in lesions with a mixed or calcific composition. (p < 0.05).

Angioplasty, Balloon, Coronary↗

Event-related auditory evoked potentials and amyotrophic lateral sclerosis.

OBJECTIVE: To study event-related potentials and particularly the P300 wave in a group of patients with amyotrophic lateral sclerosis (ALS), as changes in the P300 wave have been observed in many cases of brain damage-inducing cognitive impairment. DESIGN: Case series. SETTING: University hospital. PATIENTS: Twenty patients with ALS were compared with 20 healthy control subjects, with no significant age range and no significant difference in their education level. MAIN OUTCOME MEASURES: Amplitudes and latencies of long-latency auditory evoked potentials for the N100, P200, N200, and P300 waves were measured in the "odd-ball paradigm." Mental status was assessed by the Similarities subtest of the Wechsler Adult Intelligence Scale and by the Rapid Evaluation of Cognitive Function that allows for a mini-neuropsychological testing. The degree of disability was scored on the ALS Severity Scale, which rates bulbar and spinal functions. RESULTS: The latencies of the N100 and P200 waves did not appear to differ between normal and affected subjects; in contrast, the N200 and P300 latencies were significantly longer in the group with ALS. Sixty percent of the patients had a P300 latency more than 2 SDs above the theoretical norm that was established by the linear curve for control subjects. The N100, P200, N200, and P300 amplitudes showed no significant difference between the control subjects and the group of patients with ALS. There was no significant correlation between the N200 and P300 latencies and the disease duration or between the N200 and P300 latencies and the degree of motor impairment. The scores from the Rapid Evaluation of Cognitive Function were significantly lower in the group of patients with ALS than in the group of control subjects. CONCLUSIONS: A subtle cortical cognitive dysfunction is frequently observed in patients with ALS. These findings point also in the same direction as did previous neuropsychological, histological, and positron emission tomographic studies of ALS. Limb motor deficits and speech difficulties make it difficult to study the time course of changes in intellectual function in patients with ALS by using psychometric methods; thus, in the future, cognitive evoked potentials should constitute a fruitful method of testing cognitive function in patients with ALS to follow up their development over time.

Aged↗

Mechanism of high-speed rotational atherectomy and adjunctive balloon angioplasty revisited by quantitative coronary angiography: edge detection versus videodensitometry.

High-speed rotational coronary atherectomy (RA) is primarily used to treat complex lesions. Quantitative angiographic analysis of such complex lesions by edge detection is often unsuitable, whereas videodensitometry, measuring vessel dimensions independently of the target stenosis contours, may offer potential advantages. To gain insight into the operative mechanism of RA and to study the agreement between the two quantitative angiographic methods in measuring the minimal luminal cross-sectional area, the edge detection and videodensitometry techniques were applied to coronary angiograms of 21 lesions in 19 patients with symptoms who underwent successful RA and balloon angioplasty (BA). Obstruction diameter as determined by edge detection increased from 1.00 +/- 0.31 mm before intervention to 1.35 +/- 0.29 mm after RA (p < 0.001) and further increased to 1.74 +/- 0.33 mm after adjunctive BA (p > 0.001). The mean between-method difference (edge detection minus videodensitometry) was 0.34 mm2 before intervention, 0.13 mm2 after RA, and 0.09 mm2 after adjunctive BA (not significant). The standard deviation of the differences decreased from +/- 0.87 mm2 before intervention to +/- 0.80 mm2 after RA (not significant) and increased after BA significantly to +/- 1.21 mm2 (p < 0.05). Thus edge detection and videodensitometry provided equivalent immediate angiographic results after RA and adjunctive BA. The good agreement after RA may reflect the operative mechanism of RA, which by ablation of noncompliant plaque material yields a circular symmetric lumen with smooth surface. The increased dispersion of the between-method differences observed after adjunctive BA presumably results from dissections, plaque ruptures, and loss of luminal smoothness after balloon dilatation.

Absorptiometry, Photon↗

New invasive techniques of assessment of the physiological significance of coronary stenoses in humans.

Pressure and flow velocity can be measured distal to coronary stenoses by means of miniaturized sensors with guidewire technology. This is an alternative non-invasive method of assessing functional coronary vessel stenosis severity, applicable for the intermediate stenoses and for the results of coronary interventions. The complexity of the coronary circulation, however, limits the possibility of establishing simple cut-off criteria to identify flow-limiting stenoses. In this paper, we review advantages and limitations of the different pressure and velocity indices and their application in different clinical settings.

Blood Flow Velocity↗

Habitual snoring as a risk factor for brain infarction.

The association of habitual snoring with cerebral ischaemia was studied, in a case control-study, in 133 patients aged 45-75 years (103 men and 30 women) and 133 controls matched for sex and age. Ischaemic stroke was confirmed by brain computed tomography or magnetic resonance imaging. History of risk factors, especially of snoring and sleeping habits was recorded with structured questionnaire during interview. Prevalence of habitual snoring significantly differs between patients with stroke and controls: 31/133 (23.3%) vs 11/133 (8.3%) (Odds ratio 3.4, 95% confidence interval 1.5 to 7.6, p < 0.001). Even after adjusting for matching variables and confounding risk factors (arterial hypertension, cardiac arrhythmia, and obesity), habitual snoring carries a significant risk factor for stroke (odds ratio: 2.9, 95% confidence interval 1.3 to 6.8 (p = 0.01)). The risk of ischaemic stroke was higher among older male patients with arterial hypertension who always snored. Habitual snoring was not significantly linked with sleep-related stroke nor with the pathophysiology of strokes. Inquiring about habitual snoring should become a routine practice, especially among older male patients with arterial hypertension, and specific preventive measures should be instituted at an earlier stage.

Adult↗