Gentle protein ionization assisted by high-velocity gas flow.

Gentle protein electrospray ionization is achieved using the high-velocity gas flow of an air amplifier to improve desolvation in conventional ESI and generate intact folded protein ions in the gas phase. Comparisons are made between the ESI spectra of a number of model proteins, including ubiquitin, cytochrome c, lysozyme, and myoglobin, over a range of pH values under optimized conditions, with and without using an air amplifier to achieve high-velocity gas flow. Previously reported increased ion signals are confirmed. In addition, the peaks recorded using the air amplifier are shown to be narrower, corresponding to more complete desolvation. Significant changes in the charge-state distribution also are observed, with a shift to lower charge state at high-velocity flow. The relationship between the observed charge-state distribution and protein conformation was explored by comparing the charge-state shifts and the distributions of charge states for proteins that are or are not stable in their native conformations in low pH solutions. The data suggest retention of native or nativelike protein conformations using the air amplifier in all cases examined. This is explained by a mechanism in which the air amplifier rapidly creates small droplets from the original large ESI droplets and these microdroplets then desolvate without a significant decrease in pH, resulting in retention of the folded protein conformations. Furthermore, the holoform of ionized myoglobin is visible at pH 3.5, a much lower value than the minimum needed to see this form in conventional ESI. These results provide evidence for the importance of the conditions used in the desolvation process for the preservation of the protein conformation and suggest that the conditions achieved when using high-velocity gas flows to assist droplet evaporation and ion desolvation are much gentler than those in conventional ESI experiments.

Cytochromes c↗

Proton affinities of N-heterocyclic carbene super bases.

The gas-phase proton affinity of the N-heterocyclic carbene, 1-ethyl-3-methylimidazol-2-ylidene, was determined to be 251.3 +/- 4 kcal/mol using the kinetic method, a value which makes the carbene one of the strongest bases reported thus far. Density functional theory calculations have been carried out at the B3LYP/6-31+G(d) level to compare the high experimental value with that estimated theoretically. Experimental results also show that two other N-heterocyclic carbenes with larger substituents have even higher proton affinities. [structure: see text]

Journal Article↗

Preparation and in situ characterization of surfaces using soft landing in a Fourier transform ion cyclotron resonance mass spectrometer.

Mass-selected peptide ions produced by electrospray ionization were deposited onto fluorinated self-assembled monolayer surfaces (FSAM) surfaces by soft landing using a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) specially designed for studying interactions of large ions with surfaces. Analysis of the modified surface was performed in situ by combining 2-keV Cs+ secondary ion mass spectrometry with FT-ICR detection of the sputtered ions (FT-ICR-SIMS). Regardless of the initial charge state of the precursor ion, the SIMS mass spectra included singly protonated peptide ion, peptide fragment ions, and peaks characteristic of the surface in all cases. In some experiments, multiply protonated peptide ions and [M + Au]+ ions were also observed upon SIMS analysis of modified surfaces. For comparison with the in situ analysis of the modified surfaces, ex situ analysis of some of the modified surfaces was performed by 25-keV Ga+ time-of-flight-secondary ion mass spectrometry (TOF-SIMS). The ex situ analysis demonstrated that a significant number of soft-landed peptide ions remain charged on the surface even when exposed to air for several hours after deposition. Charge retention of soft-landed ions dramatically increases the ion yields obtained during SIMS analysis and enables very sensitive detection of deposited material at less than 1% of monolayer coverage. Accumulation of charged species on the surface undergoes saturation due to coulomb repulsion between charges at close to 30% coverage. We estimated that close to 1 ng of peptide could be deposited on the spot area of 4 mm2 of the FSAM surface without reaching saturation.

Journal Article↗

Atmospheric pressure ionization in a miniature mass spectrometer.

A miniature cylindrical ion trap mass spectrometer featuring an atmospheric pressure interface allowing atmospheric pressure chemical ionization and electrospray ionization is described together with its analytical performance characteristics. The vacuum system, ion optics, mass analyzer, control electronics system, and detection system have all been designed and built in-house. The design is based upon a three-stage, differentially pumped vacuum system with the instrument capable of being interfaced to many types of atmospheric pressure ionization sources. Ions are transferred through home-built ion optics, and instrument control is achieved through custom-designed electronics and LabView control software. Corona discharge ionization and electrospray ionization sources are implemented and used to allow the analysis of both gaseous- and solution-phase samples during the characterization of the instrument. An upper mass/charge limit of approximately 450 Th with unit resolution was achieved using a 2.5-mm-internal radius cylindrical ion trap as the mass analyzer. The specificity of the instrument can be increased by employing the MS/MS capabilities of the ion trap and has been demonstrated for nitrobenzene. Limits of detection for the trace analysis in air of the chemical warfare agent simulant methyl salicylate (1.24 ppb) and for nitrobenzene (629 pptr) are achieved. The dynamic range of the instrument is currently limited to approximately 2 orders of magnitude by saturation of the detection electronics. Isolation and collision-induced dissociation efficiencies in MS/MS experiments both greater than 50% are reported. Electrospray/nanospray data are presented on solutions including 100 microM (D,L)-arginine, 10 microM (-)-ephedrine, and 10 microM lomefloxacin.

Journal Article↗

Improved detection of low vapor pressure compounds in air by serial combination of single-sided membrane introduction with fiber introduction mass spectrometry (SS-MIMS-FIMS).

The use of two methods in tandem, single-sided membrane introduction mass spectrometry (SS-MIMS) and fiber introduction mass spectrometry (FIMS), is presented as a technique for field analysis. The combined SS-MIMS-FIMS technique was employed in both a modified commercial mass spectrometer and a miniature mass spectrometer for the selective preconcentration of the explosive simulant o-nitrotoluene (ONT) and the chemical warfare agent simulant, methyl salicylate (MeS), in air. A home-built FIMS inlet was fabricated to allow introduction of the solid-phase microextraction (SPME) fiber into the mass spectrometer chamber and subsequent desorption of the trapped compounds using resistive heating. The SS-MIMS preconcentration system was also home-built from commercial vacuum parts. Optimization experiments were done separately for each preconcentration system to achieve the best extraction conditions prior to use of the two techniques in combination. Improved limits of detection, in the low ppb range, were observed for the combination compared to FIMS alone, using several SS-MIMS preconcentration cycles. The SS-MIMS-FIMS response for both instruments was found to be linear over the range 50 to 800 ppb. Other parameters studied were absorption time profiles, effects of sample flow rate, desorption temperature, fiber background, memory effects, and membrane fatigue. This simple, sensitive, accurate, robust, selective, and rapid sample preconcentration and introduction technique shows promise for field analysis of low vapor pressure compounds, where analyte concentrations will be extremely low and the compounds are difficult to extract from a matrix like air.

Air Pollutants↗

Negatively-charged halide adducts of homochiral serine octamers.

Negatively charged halide adducts of serine octamers, (Ser(8)+2Cl)(2-) and (Ser(8)+2Br)(2-), appear as magic number clusters in the negative ion electrospray mass spectra of solutions containing serine and the halide. Like the well-known protonated serine octamer, these negatively charged adducts are formed with homochiral preference and also undergo chiroselective substitution reactions with other amino acids. Tandem mass spectra of negatively charged halide adducts of serine octamers show that these ions also have a characteristic fragmentation signature. The fact that octamers of both polarities display analogous chemical properties suggests that these may be characteristics of the so-far-unknown neutral octamer. If serine played a key role in the origin of homochirality on the primitive earth, it was likely through both the neutral octamer and the ionic adducts. Unlike the octamers, the formation of halide-containing serine cluster ions of particular sizes is unfavorable under the conditions of the experiment. Signals corresponding to the ions (Ser(9)+2Br)(2-) and (Ser(15)+2Br)(2-) are particularly low in intensity, giving rise to gaps in the distribution of serine/bromide clusters in the negative ion electrospray mass spectra. These cluster sizes are likely to correspond to unstable "anti-magic number" clusters recently reported by Clemmer.

Bromides↗

High-throughput mass spectrometer using atmospheric pressure ionization and a cylindrical ion trap array.

The analytical performance of an atmospheric pressure sampling, multiple-channel, high-throughput mass spectrometer was investigated using samples of a variety of types. The instrument, based on an array of cylindrical ion traps, was built with four independent channels and here is operated using two fully multiplexed channels (sources, ion optics, ion traps, detectors) capable of analyzing different samples simultaneously. Both channels of the instrument were incorporated within the same vacuum system and operated using a common set of control electronics. A multichannel electrospray ionization source was assembled and used to introduce samples including solutions of organic compounds, peptides, and proteins simultaneously into the instrument in a high-throughput fashion. Cross-talk between the channels of the instrument occurred in the detection system and could be minimized to 1-2% using shielding between detector channels. In this initial implementation of the instrumentation, an upper mass/charge limit of approximately 1300 Th was observed (+13 charge state of myoglobin) and unit mass/charge resolution was achieved to approximately 800 Th. The rather limited dynamic range (2-3 orders of magnitude for low-concentration analytes) is due to cross-talk contributions from more concentrated species introduced into a different channel. Analysis of mixtures of alkylamines and peptides is demonstrated, but analysis of mixtures with a wide spread in mass/charge ratios was not possible due to mass discrimination in the ion optics. Further refinement of the vacuum system and ion optics will allow the addition of more channels of parallel mass analysis and facilitate applications in fields such as proteomics and metabolomics.

Amines↗

The Orbitrap: a new mass spectrometer.

Research areas such as proteomics and metabolomics are driving the demand for mass spectrometers that have high performance but modest power requirements, size, and cost. This paper describes such an instrument, the Orbitrap, based on a new type of mass analyzer invented by Makarov. The Orbitrap operates by radially trapping ions about a central spindle electrode. An outer barrel-like electrode is coaxial with the inner spindlelike electrode and mass/charge values are measured from the frequency of harmonic ion oscillations, along the axis of the electric field, undergone by the orbitally trapped ions. This axial frequency is independent of the energy and spatial spread of the ions. Ion frequencies are measured non-destructively by acquisition of time-domain image current transients, with subsequent fast Fourier transforms (FFTs) being used to obtain the mass spectra. In addition to describing the Orbitrap mass analyzer, this paper also describes a complete Orbitrap-based mass spectrometer, equipped with an electrospray ionization source (ESI). Ions are transferred from the ESI source through three stages of differential pumping using RF guide quadrupoles. The third quadrupole, pressurized to less than 10(-3) Torr with collision gas, acts as an ion accumulator; ion/neutral collisions slow the ions and cause them to pool in an axial potential well at the end of the quadrupole. Ion bunches are injected from this pool into the Orbitrap analyzer for mass analysis. The ion injection process is described in a simplified way, including a description of electrodynamic squeezing, field compensation for the effects of the ion injection slit, and criteria for orbital stability. Features of the Orbitrap at its present stage of development include high mass resolution (up to 150,000), large space charge capacity, high mass accuracy (2-5 ppm), a mass/charge range of at least 6000, and dynamic range greater than 10(3). Applications based on electrospray ionization are described, including characterization of transition-metal complexes, oligosaccharides, peptides, and proteins. Use is also made of the high-resolution capabilities of the Orbitrap to confirm the presence of metaclusters of serine octamers in ESI mass spectra and to perform H/D exchange experiments on these ions in the storage quadrupole.

Alcohol Dehydrogenase↗

Ambient mass spectrometry using desorption electrospray ionization (DESI): instrumentation, mechanisms and applications in forensics, chemistry, and biology.

Analytical characteristics of DESI are summarized. Examples of applications to small and large molecules, to in situ analysis, and to high-throughput analyses are presented. Evidence is provided for both a heterogeneous charge-transfer mechanism and a droplet pick-up mechanism of ionization. The speed, lack of the need for sample preparation, selectivity, and sensitivity of DESI are all demonstrated and discussed. Instrumentation is also discussed. Forensic applications as well as emerging areas of application including tissue imaging are given emphasis.

Animals↗

Ion/molecule reactions in a miniature RIT mass spectrometer.

Ion/molecule reactions were explored in a newly developed miniature mass spectrometer fitted with a rectilinear ion trap (RIT) mass analyzer. The tandem mass spectrometry performance of this instrument is demonstrated using collision induced dissociation (CID) and ion/molecule reactions. The latter includes Eberlin transacetalization reactions and electrophilic additions. Selective detection of the chemical warfare simulant dimethyl methyl phosphonate (DMMP) was achieved through selective Eberlin reactions of its characteristic phosphonium fragment ion CH3OP(+)(O)CH3 (m/z 93), with 1,4-dioxane or 1,3-dioxolane. Efficient adduct formation as a result of electrophilic attack by the phosphonium ion on various nucleophilic reagents, including 1,1,3,3-tetramethyl urea, methanesulfonic acid methyl ester, dimethyl sulfoxide and methyl salicylate, was also observed using the RIT device. The product ions of these reactions were analyzed using CID and the characteristic fragmentation patterns of the ionic addition products were recorded using multiple-stage experiments in the miniature RIT instrument. This study clearly demonstrates that a small, home-built, miniature RIT mass spectrometer can be used to perform analytically useful ion/molecule reactions and also that instruments like this have the potential to provide a portable platform for in situ detection of organophosphorus esters and related compounds with high specificity using tandem mass spectrometry.

Journal Article↗

Novel CFCs-substitutes recommended by EPA (hydrofluorocarbon-245fa and hydrofluoroether-7100): ion chemistry in air plasma and reactions with atmospheric ions.

The ion chemistry of the title compounds, a nonafluorobutyl methyl ether and a hydrofluoropropane, is elucidated by a combination of studies using atmospheric pressure ionization mass spectrometry and triple quadrupole mass spectrometry. In the positive ion mode, the hydrofluoroether readily forms an [M - F]+ ion, attributable to hydronium ion induced dehydrofluorination, the product of which can be further hydrated to give a protonated hydrofluoroester. By contrast, the hydrofluoropropane does not react with the hydronium ion but rather gives hydrofluoroalkenylium cations via H atom and F atom abstraction by the dioxygen radical cation. In the negative ion mode, the fluorobutyl methyl ether undergoes dissociative electron capture with O2-*, O2-*(H2O), O3-*, and NO2- to generate the fluorobutoxy anion, which can dissociate by CF2[doublebond]O loss to give the perfluorocarbanion when the precursor ions are internally excited. The hydrofluoropropane reacts readily with common atmospheric anions to form molecular complexes with F-, O2-*, and O3-* and the strongly H-bonded species, O2-*(HF) and F-(HF). Interestingly, isomeric pentafluoropropanes form in the reaction with O2-*, either O2-*(HF) or F-(HF), depending on the specific pattern of the fluoro substitution.

Air↗

Chiral and isomeric analysis by electrospray ionization and sonic spray ionization using the fixed-ligand kinetic method.

The fixed-ligand version of the kinetic method has been used for chiral and for isomeric analysis by studying the dissociation kinetics of transition metal-bound trimeric cluster ions ([(M(II) + L(fixed)-H)(ref*)(An)](+), where M(II) is a transition metal, L fixed is a fixed (non-dissociating) ligand, ref* is a reference ligand and An is the analyte. The trimeric cluster ions are readily generated by electrospray ionization (ESI) or sonic spray ionization (SSI). The size of the fixed ligand, L- Phe-Gly-L-P he-Gly, is chosen based on previous results but with the inclusion of aromatic functionality to increase chiral recognition. Improved chiral/isomeric differentiation results from enhanced chiral/isomeric interactions (metal-ligand and ligand-ligand) due to the fixed ligand. As shown in the cases of chiral dipeptides (D-Ala-D-Ala/L-Ala-L-Ala), sugars (D/L-glucose, D/L-mannose) and isomeric tetrapeptides (L-Ala-Gly-Gly-Gly/Gly-Gly -Gly-L-Ala), improved chiral/isomeric discrimination by factors from three to six were obtained by the fixed ligand procedure. Chiral recognition is independent of the concentrations of the analyte, the reference ligand, the fixed ligand and the transition metal salt, a great advantage for practical applications. In addition to increased chiral distinction, the simplified dissociation kinetics also contribute to improved accuracy in chiral quantification, in comparison with data obtained by investigating the dissociation kinetics of simple trimeric cluster ions [M(II)(ref*)2(An) H](+). Accurate determination of enantiomeric excess (ee) is demonstrated by enantiomeric quantification of D-Ala-D-Ala/L-Ala-L-Ala down to 2% ee. Both ESI and SSI allow chiral quantification with similar accuracies. The performance of chiral analysis experiments is not limited to ion trapping devices such as quadrupole ion trap mass spectrometers by a hybrid quadrupole-time of flight (Q-ToF) mass spectrometer is shown to provide an alternative choice. The fixed-ligand kinetic method is not restricted to any particular kinds of isomers and, hence, represents a general procedure for improving molecular recognition and chiral analysis in the gas phase.

Carbohydrates↗

Preparative linear ion trap mass spectrometer for separation and collection of purified proteins and peptides in arrays using ion soft landing.

A preparative mass spectrometer for microarray fabrication is reported. The instrument includes an atmospheric pressure ionization source, a linear ion trap mass analyzer, an ion collection surface positioning system, and a surface loading chamber with independent vacuum pumping. It was designed for the production of protein arrays using the ion soft-landing technique to collect ions on a surface after separation by mass/charge ratio. Small microarrays have been prepared by isolating and soft landing individual protein or peptide ions after electrospray ionization of mixtures. The composition and purity of the separated materials has been confirmed using independent external mass spectrometric analysis of rinse solutions of the collected spots, either by the new method of electrosonic spray ionization MS or by nanospray ionization MS. The ability to retain bioactivity in the mass-selected and collected biomolecules has been demonstrated in particular cases. The reported instrument has also been characterized as an analytical mass spectrometer.

Amino Acid Sequence↗

Mass spectrometry sampling under ambient conditions with desorption electrospray ionization.

A new method of desorption ionization is described and applied to the ionization of various compounds, including peptides and proteins present on metal, polymer, and mineral surfaces. Desorption electrospray ionization (DESI) is carried out by directing electrosprayed charged droplets and ions of solvent onto the surface to be analyzed. The impact of the charged particles on the surface produces gaseous ions of material originally present on the surface. The resulting mass spectra are similar to normal ESI mass spectra in that they show mainly singly or multiply charged molecular ions of the analytes. The DESI phenomenon was observed both in the case of conductive and insulator surfaces and for compounds ranging from nonpolar small molecules such as lycopene, the alkaloid coniceine, and small drugs, through polar compounds such as peptides and proteins. Changes in the solution that is sprayed can be used to selectively ionize particular compounds, including those in biological matrices. In vivo analysis is demonstrated.

Journal Article↗