AIM: To compare the efficacy and functional durability of the American Medical Systems 800 (AMS 800) artificial urinary sphincter (AUS) device for patients with neurogenic and non-neurogenic incontinence. METHODS: From 1985 to 2000, 38 patients underwent implantation of an AMS 800 AUS at our institution. Thirty of these patients had complete records and follow-up data available. The mean follow-up for these two groups of patients was six years. Seventeen devices (57%) were implanted for non-neurogenic indications including incontinence after prostatectomy or hysterectomy. Thirteen devices (43%) were implanted for neurogenic conditions including spina bifida, spinal cord injury or severe pelvic trauma. The primary end point measured was continence. Secondary end points included mechanical and non-mechanical device failure, re-operation and complication rates between the two groups. RESULTS: In the neurogenic group, only two patients (15%) have their original device in situ without revisions. Only three patients (23%) in this group are entirely dry. In contrast, seven patients (41%) in the non-neurogenic group are completely dry with their original device in situ. A further four (23%) are entirely dry after device revision or replacement surgery. The rates of mechanical failure were not statistically different between the two groups. The rate of non-mechanical failure (NMF) was statistically greater in the neurogenic group in comparison to that in the non-neurogenic group (p < 0.05). CONCLUSIONS: Insertion of an AMS 800 artificial sphincter remains a durable means of regaining urinary continence. Patients who are incontinent as a result of an underlying neurological deficit should be counselled that they might have a higher risk of non-mechanical device failure, requirement for re-operation and that their overall long-term continence rates may be poor.
BACKGROUND: Management of traumatic rupture of the male membranous urethra remains controversial. Long-term morbidity can include urinary incontinence, urethral stricture and erectile dysfunction. AIMS: To review management and outcome of urethral rupture to improve treatment protocols. METHODS: A retrospective study of 47 patients presenting with traumatic urethral rupture over 25 years was performed. RESULTS: All patients underwent emergency suprapubic catheterisation, 32 patients had open surgical realignment at 1-2 weeks; 78% of whom developed strictures. Ten patients unsuitable for early repair underwent delayed transabdominal transpubic urethroplasty at three months: 40% of whom developed strictures. Five patients with partial rupture were managed by cystoscopy and urethral catheter. Erectile dysfunction correlated to initial injury rather than treatment. CONCLUSIONS: If the patient is stable and requires emergency laparotomy for other abdominal injuries, he should have immediate realignment of the urethra. Early realignment of the urethra at laparotomy at 1-2 weeks can be combined with orthopaedic fixation of pelvic fractures. Patients who remain unstable due to associated injuries should have delayed urethroplasty at three months.
BACKGROUND: Deliberate genital self-mutilation is rare. Successful self-castration has been reported in a small number of individuals. METHOD: This study reports one such case of self-castration in a transsexual who was dissatisfied with waiting times for sex reassignment surgery (SRS). RESULT AND CONCLUSION: The apparent triggering factor in this case appears to be depression related to the lengthy waiting times for SRS. As neither psychotherapy nor hormonal manipulation is successful, consideration should be given to improving the resources for patients with genuine gender dysmorphism.
Thirteen adult male patients who had an AS 800 artificial urinary sphincter inserted are reviewed. Five have had malfunction, and in four the causes were diagnosed radiologically. These included: fistula formation, leakage of hydraulic fluid, air in the system, and inadequate deflation of the cuff. Since the sphincter is filled with contrast medium, it is ideally suited to radiological assessment.