PubMed Health⌕ Search

Biomedical subjects

R Gref

Publications and source records attributed to R Gref.

At least 19 recordsLinked to original sources

Novel core(polyester)-shell(polysaccharide) nanoparticles: protein loading and surface modification with lectins.

This study describes new lectin-decorated or protein-loaded nanoparticles with a hydrophobic poly(epsilon-caprolactone) (PCL) core and a hydrophilic dextran (Dex) corona. In this view, a family of block Dex-PCLn copolymers was first synthesized, consisting of a Dex backbone to which n preformed PCL blocks were grafted. The ability of these new copolymers to form nanoparticles was evaluated in comparison with a series of PCL homopolymers of various molecular weights (2000, 10,000 and 40,000 g/mole). Two different nanoparticle preparation methods have been developed and tested for their efficacy to incorporate proteins. For this, three proteins were used: a model protein, bovine serum albumin (BSA), a lectin from leaves of Bauhinia monandra (BmoLL) and Lens culinaris (LC) lectin. All these proteins were successfully incorporated in nanoparticles with a mean diameter around 200 nm. Lectins could also be adsorbed onto the surface of Dex-PCLn nanoparticles. Surface-bound BmoLL conserved its hemagglutinating activity, suggesting the possible application of this type of surface-modified nanoparticles for targeted oral administration. Caco-2 cellular viability was higher than 70% when put in contact with Dex-PCLn nanoparticles, even at concentrations as high as 660 microg/ml.

Animals↗

Design of poly-epsilon-caprolactone nanospheres coated with bioadhesive hyaluronic acid for ocular delivery.

This study was performed to design a new ocular drug delivery system based on poly-epsilon-caprolactone (PCL) biodegradable nanospheres (NS) coated with a bioadhesive polymer, hyaluronic acid (HA), in order to combine ophthalmic prolonged action with the ease of application. The aim of this work was to investigate three strategies to attach HA on NS surface: (1) coating the core by chain entanglement with HA; (2) coating NS by HA adsorption; (3) coating NS by electrostatic interactions between negatively charged HA and a cationic surfactant (stearylamine, SA, or benzalkonium chloride, BKC). A radioimmunoassay technique, usually used for HA quantification in serum, was transposed to determine the amount of HA on the NS. The results show that HA is strongly attached on NS positively charged by cationic surfactant. This system is stable and not influenced by dilution. These results show the possibility of using cationic surfactants to obtain a HA coating by electrostatic interactions. BKC, approved for ophthalmic administration, was retained because it was more firmly anchored within the PCL matrix and the amount of HA attached was high (41.6 microg HA/mg PCL). Moreover, the yield of fixation reached 50%. Therefore, by using a simple preparation method, it was possible to obtain stable HA and intact HA-coated NS.

Adhesives↗

Protein C-loaded monomethoxypoly (ethylene oxide)-poly(lactic acid) nanoparticles.

This paper deals with the preparation and characterization of monomethoxypoly(ethylene oxide)-poly(lactic acid) (MPEO-PLA) nanoparticles containing protein C, a plasma inhibitor which regulates the mechanism of blood coagulation. Protein C was entrapped in MPEO-PLA nanoparticles using the double emulsion method. The influence of MPEO-PLA copolymers on the different parameters was evaluated: characteristics of protein C-loaded nanoparticles, in vitro release of the protein, evolution of the particle size with incubation time and MPEO release. The nanoparticle size does not depend on copolymer characteristics (MPEO and/or PLA block molecular weight). On the other hand, the efficiency of protein C entrapment is affected by the copolymer characteristics. The burst effect during the protein C release is increased with the hydrophilic character of the copolymer. Moreover, protein C adsorption on the particle surface during its release may be related to MPEO release. Only 25% of the released protein C is active, which clearly illustrates that it is altered during its encapsulation. The optimization of the experimental parameters which disturbed entrapped protein C activity, i.e. sonication time and organic solvent was investigated and has led to a preservation of protein C activity. Then, to optimize its entrapment efficiency, a blend PLA/MPEO-PLA (25/75) was used to prepare nanoparticles. This blend limited burst effect of protein C and its adsorption. However, protein C is only partially released which implicates further investigation for a potential therapeutic use.

Lactates↗

Relationship between complement activation, cellular uptake and surface physicochemical aspects of novel PEG-modified nanocapsules.

The aim of our work was to examine the relationship between modifications of the surface of nanocapsules (NC) by adsorption or covalent grafting of poly(ethylene oxide) (PEG), and changes in their phospholipid (PL) content on complement activation (C3 cleavage) and on uptake by macrophages. The physicochemical characterization of the NC included an investigation of their properties, such as surface charge, size, hydrophilicity, morphology and homogeneity. This is the first time that such properties have been correlated with biological interactions for NC, a novel carrier system with a structure more complex than nanospheres. C3 crossed immunoelectrophoresis revealed the reduced activation for NC with longer PEG chain and higher density, although all formulations induced C3 cleavage to a lesser or greater extent. NC bearing PEG covalently bound to the surface were weaker activators of complement than plain PLA [poly(D,L-lactide)] NC or nanospheres (NS). Furthermore, the fluorescent/confocal microscopy of J774A1 cells in contact with NC reveal a dramatically reduced interaction with PEG-bearing NC. However, the way in which PEG was attached (covalent or adsorbed) seemed to affect the mechanism of uptake. Taken together, these results suggest that the low level of protein binding to NC covered with a high density of 20kDa PEG chains is likely to be due to the steric barriers surrounding these particles, which prevents protein adsorption and reduces their interaction with macrophages.

Adsorption↗

Development and characterization of CyA-loaded poly(lactic acid)-poly(ethylene glycol)PEG micro- and nanoparticles. Comparison with conventional PLA particulate carriers.

Cyclosporin A (CyA) loaded poly(lactic acid)-poly(ethylene glycol) (PLA-PEG) micro- and nanoparticles have been developed using an emulsion-solvent evaporation method. Physico-chemical properties, peptide loading content and in vitro release profiles of these novel CyA carriers were compared with those corresponding to conventional PLA micro- and nanoparticles. Results obtained confirm the previously described disposition of PEG chains on the surface of the PLA-PEG formulations. In addition, they revealed the presence of CyA molecules on the surface of both PLA and PLA-PEG systems. Further determination of the surface chemical composition by electron spectroscopy for chemical analysis (ESCA) allowed us to quantify the amount of CyA in the nanospheres' top layers, this amount being higher for nanoparticles than for microparticles, and higher for the PLA systems than for those based on PLA-PEG. In vitro release experiments revealed that PLA-PEG particles provided a more adequate control of CyA release than conventional PLA micro- and nanoparticles. Physico-chemical characterization of the systems during the release studies showed that the developed PLA and PLA-PEG micro- and nanoparticles were not degraded, which suggest a diffusion-mediated release mechanism. Furthermore, we have hypothesized that the hydrophilic outer shell of PEG provides a stationary layer for the diffusion of CyA.

Cyclosporine↗

Biodistribution of long-circulating PEG-grafted nanocapsules in mice: effects of PEG chain length and density.

PURPOSE: To study the pharmacokinetics and biodistribution of novel polyethyleneglycol (PEG) surface-modified poly(rac-lactide) (PLA) nanocapsules (NCs) and to investigate the influence of PEG chain length and content. METHODS: The biodistribution and plasma clearance in mice of different NC formulations were studied with [3H]-PLA. PLA-PEG copolymers were used in NC preparations at different chain lengths (5 kDa and 20 kDa) and PEG contents (10% and 30% w/w of total polymer). In vitro and in vivo stability were also checked. RESULTS: Limited [3H]-PLA degradation was observed after incubation in mouse plasma for 1 h, probably because of to the large surface area and thin polymer wall. After injection into mice. NCs prepared with PLA-PEG copolymers showed an altered distribution compared to poloxamer-coated PLA NCs. An increased concentration in plasma was also observed for PLA-PEG NCs. even after 24 h. A dramatic difference in the pharmacokinetic parameters of PLA-PEG 45-20 30% NCs compared to poloxamer-coated NCs indicates that covalent attachment, longer PEG chain lengths, and higher densities are necessary to produce an increased half-life of NCs in vivo. CONCLUSIONS: Covalently attached PEG on the surface of NCs substantially can reduce their clearance from the blood compartment and alter their biodistribution.

Algorithms↗

Cure of experimental Chagas' disease by the bis-triazole DO870 incorporated into 'stealth' polyethyleneglycol-polylactide nanospheres.

We have incorporated several inhibitors of sterol biosynthesis into long-circulating polyethyleneglycol-polylactide (PEG-PLA) nanospheres in order to improve the bioavailability of these poorly soluble compounds. Mice infected with CL and Y strains of Trypanosoma cruzi and treated for 30 consecutive days with DO870-loaded nanospheres at doses of 3 mg/kg/day, by the intravenous route, showed a significant cure rate (60-90%) for both strains. The activity was dose dependent and significant activity was observed for doses > or = 0.75 mg/kg/day. No cure was observed in mice treated with unloaded nanoparticles. Ketoconazole and itraconazole failed to induce cure against the Y strain even in the entrapped form.

Animals↗

'Stealth' corona-core nanoparticles surface modified by polyethylene glycol (PEG): influences of the corona (PEG chain length and surface density) and of the core composition on phagocytic uptake and plasma protein adsorption.

Nanoparticles possessing poly(ethylene glycol) (PEG) chains on their surface have been described as blood persistent drug delivery system with potential applications for intravenous drug administration. Considering the importance of protein interactions with injected colloidal dug carriers with regard to their in vivo fate, we analysed plasma protein adsorption onto biodegradable PEG-coated poly(lactic acid) (PLA), poly(lactic-co-glycolic acid) (PLGA) and poly(varepsilon-caprolactone) (PCL) nanoparticles employing two-dimensional gel electrophoresis (2-D PAGE). A series of corona/core nanoparticles of sizes 160-270 nm were prepared from diblock PEG-PLA, PEG-PLGA and PEG-PCL and from PEG-PLA:PLA blends. The PEG Mw was varied from 2000-20000 g/mole and the particles were prepared using different PEG contents. It was thus possible to study the influence of the PEG corona thickness and density, as well as the influence of the nature of the core (PLA, PLGA or PCL), on the competitive plasma protein adsorption, zeta potential and particle uptake by polymorphonuclear (PMN) cells. 2-D PAGE studies showed that plasma protein adsorption on PEG-coated PLA nanospheres strongly depends on the PEG molecular weight (Mw) (i.e. PEG chain length at the particle surface) as well as on the PEG content in the particles (i.e. PEG chain density at the surface of the particles). Whatever the thickness or the density of the corona, the qualitative composition of the plasma protein adsorption patterns was very similar, showing that adsorption was governed by interaction with a PLA surface protected more or less by PEG chains. The main spots on the gels were albumin, fibrinogen, IgG, Ig light chains, and the apolipoproteins apoA-I and apoE. For particles made of PEG-PLA45K with different PEG Mw, a maximal reduction in protein adsorption was found for a PEG Mw of 5000 g/mole. For nanospheres differing in their PEG content from 0.5 to 20 wt %, a PEG content between 2 and 5 wt % was determined as a threshold value for optimal protein resistance. When increasing the PEG content in the nanoparticles above 5 wt % no further reduction in protein adsorption was achieved. Phagocytosis by PMN studied using chemiluminescence and zeta potential data agreed well with these findings: the same PEG surface density threshold was found to ensure simultaneously efficient steric stabilization and to avoid the uptake by PMN cells. Supposing all the PEG chains migrate to the surface, this would correspond to a distance of about 1.5 nm between two terminally attached PEG chains in the covering 'brush'. Particles from PEG5K-PLA45K, PEG5K-PLGA45K and PEG5K-PCL45K copolymers enabled to study the influence of the core on plasma protein adsorption, all other parameters (corona thickness and density) being kept constant. Adsorption patterns were in good qualitative agreement with each other. Only a few protein species were exclusively present just on one type of nanoparticle. However, the extent of proteins adsorbed differed in a large extent from one particle to another. In vivo studies could help elucidating the role of the type and amount of proteins adsorbed on the fate of the nanoparticles after intraveinous administration, as a function of the nature of their core. These results could be useful in the design of long circulating intravenously injectable biodegradable drug carriers endowed with protein resistant properties and low phagocytic uptake.

Journal Article↗

Surface modification of poly(lactic acid) nanospheres using hydrophobically modified dextrans as stabilizers in an o/w emulsion/evaporation technique.

Sterically stabilized biocompatible poly(lactic acid) (PLA) nanospheres were prepared by an o/w emulsion/evaporation technique, using hydrophobically modified dextrans (DexP) as the emulsion stabilizer. Photon correlation spectroscopy, zetametry, and differential scanning calorimetry studies corroborated that interfacial adhesion between immiscible dextran and PLA chains was achieved by compatibilization of polymer segments via hydrophobic groups grafted onto dextran and thus leading to the formation of entanglements between the hydrophobic dextran parts and the PLA matrix. The presence of dextran exposed at the particle surface was confirmed by X-ray photoelectron spectroscopy and by the fact that the suspensions showed an increased stability in concentrated NaCl solutions and a reduction of bovine serum albumin adsorption compared to uncoated PLA nanoparticles. A comparison of the characteristics of PLA nanospheres DexP-coated via the emulsion procedure (NS(em)) with those of PLA particles coated by DexP adsorption (NS(ad)) suggests that the conformation of the polymer in the superficial layers may be different. However, both DexP layers behave similarly in terms of stability and protein adsorption.

Adsorption↗

Protein encapsulation within poly(ethylene glycol)-coated nanospheres. II. Controlled release properties.

The development of injectable nanoparticulate "stealth" carriers for protein delivery is a major challenge. The aim of this work was to investigate the possibility of achieving the controlled release of a model protein, human serum albumin (HSA), from poly(ethylene glycol) (PEG)-coated biodegradable nanospheres (mean diameter of about 200 nm) prepared from amphiphilic diblock PEG-poly(lactic acid) (PLA) copolymers. HSA was efficiently incorporated into the nanospheres, reaching loadings as high as 9% (w/w). Results of the in vitro release studies showed that it is possible to control the HSA release by choosing the appropriate nanosphere size, loading, and composition. These results also revealed that, following their release, HSA molecules readsorbed onto the nanospheres surfaces when they were not protected by a PEG coating. We were surprised to observe that in spite of the water uptake of the PLA-PEG nanospheres [11-29% (w/w)], the copolymer did not significantly degrade after a 15-day incubation period. Therefore, we concluded that during this time HSA release from PLA-PEG nanospheres followed a diffusion mechanism where bulk erosion and surface desorption were negligible.

Biodegradation, Environmental↗

Lidocaine loaded biodegradable nanospheres. II. Modelling of drug release.

The mechanism of the release of encapsulated lidocaine from spherical nanoparticles based on poly(D,L-lactic acid) polymer carrier (PLA) was studied through mathematical modelling. The drug was incorporated in the PLA matrix with particle sizes from approximately 250 to 820 nm and corresponding loadings varying from about 7 to 32% (w/w). The rate of release correlated with the particle drug loading and was fastest at small particles with a low drug content. It was about four times slower at large particles with a high loading when the process of release took up to 100 h. Two simple models, diffusion and dissolution, were applied for the description of the experimental data of lidocaine release and for the identification of the release mechanisms for the nanoparticles of different drug loading. The modelling results showed that in the case of high drug loadings (about 30% w/w), where the whole drug or a large part of it was in the crystallised form, the crystal dissolution could be the step determining the release rate. On the other hand, the drug release was diffusion-controlled at low loadings (less than 10% w/w) where the solid drug was randomly dispersed in the matrix. The estimated values of the diffusion coefficient of lidocaine in these particles were in the range of 5-7x10(-20) m(2)/s. A significant influence of both crystal dissolution and drug diffusion on the overall rate of release was assumed at PLA nanoparticles with medium lidocaine loadings.

Anesthetics, Local↗

Preparation and characterization of protein C-loaded PLA nanoparticles.

This paper deals with the preparation and the characterization of poly(lactic acid) (PLA) nanoparticles containing protein C, a plasma inhibitor. Nanoparticles were prepared by the double emulsion method (w/o/w), using methylene chloride as an organic solvent and polyvinyl alcohol (PVA) or human serum albumin (HSA) as a surfactant. The influence of experimental constraints such as sonication and organic solvent on protein C activity was evaluated. It appears that a short time of sonication as well as the addition of acetone to methylene chloride (1/1) limited the lost of protein C activity. The study of protein C adsorption on blank PLA nanoparticles gave evidence to hydrophobic interactions between these two entities. The increase in PLA molecular weight on the characteristics of the protein C-loaded nanoparticles led to both a slightly decreased particle size and a lower polydispersity index, whereas the entrapment efficiency of protein C was not affected. The use of HSA as a surfactant allowed the increase in the entrapment efficiency of protein C but prevented its release. Finally, the evaluation of the activity of released protein C clearly illustrates that it was disturbed during the nanoparticle preparation. Thus, the obtained results emphasize the potential of protein C-loaded biodegradable nanoparticles for protein progressive delivery in plasma.

Anticoagulants↗

Lidocaine-loaded biodegradable nanospheres. I. Optimization Of the drug incorporation into the polymer matrix.

Spherical nanoparticulate drug carriers made of poly(d,l-lactic acid) with controlled size were designed. A local anesthetic, lidocaine, a small hydrophobic molecule, was incorporated in the core with loadings varying from about 7 to 32% (w/w) and increasing with the particle size. Particles with sizes from about 250 to 820 nm and low polydispersity were prepared with good reproducibility; the polymer concentration (at constant surfactant concentration) governed the particle size. The large particles with a high loading ( approximately 30%) showed under in vitro conditions a slow release over 24-30 h, the medium sized carriers (loading of approximately 13%) released the drug over about 15 h, whereas the small particles with small loading ( approximately 7%) exhibited a rapid release over a couple of hours. It seems that the drug release rate is related to the state (crystallized or dispersed) of the drug incorporated in the polymer matrix.

Anesthetics, Local↗

MPEO-PLA nanoparticles: effect of MPEO content on some of their surface properties.

Nanoparticles of poly(lactic acid) (PLA) and of blends of PLA and monomethoxypoly(ethylene oxyde) (MPEO-PLA) were prepared by the double emulsion method. Sucrose was added to overcome nanoparticle aggregation with freeze-drying. Whereas PLA nanoparticles rapidly are phagocytosed by the mononuclear phagocyte system cells, the uptake of MPEO-PLA nanoparticles is delayed. Opsonization is one of the steps of phagocytosis, and serum complement is a major component of the opsonin system. The in vitro complement consumption of the prepared nanoparticles was evaluated as a function of time and of their surface area. To avoid the aggregation of MPEO-PLA nanoparticles due to MPEO crystallization, sucrose was necessary, and its concentration was dependent on MPEO proportion in the nanoparticle suspension. As expected, the complement consumption for PLA nanoparticles is faster and more important than for PLA/MPEO-PLA blends. The complement consumption decreases with the increase in MPEO surface density. Complement is less consumed with the lower surface density provided by a higher molecular weight than by the higher surface density provided by a lower molecular weight MPEO. The complement consumption seems to be dependent on the number of nanoparticles in contact with human serum. Finally, the model of steric repulsion of MPEO towards proteins and the importance of the surface density of MPEO were emphasized.

Biocompatible Materials↗

Interactions between a macrophage cell line (J774A1) and surface-modified poly (D,L-lactide) nanocapsules bearing poly(ethylene glycol).

The interactions of naked and surface-modified poly(D,L-lactic acid) (PLA) nanocapsules (NC), where polyethyleneglycol (PEG) was adsorbed or covalently attached, have been studied with a macrophage-like cell line. The fluorescent oil marker, DiD, was successfully encapsulated in NCs in order to follow their interactions with cells. The cell-associated fluorescence obtained with PEG-PLA NC was about 3- to 13-fold lower than that obtained with naked-PLA NC. The effects of PEG chain length, its content as a percentage of total polymer and NC concentration in the culture medium were evaluated. PEG-PLA NC showed dramatically reduced fluorescence association with cells during an 18 h incubation compared with naked-PLA NC, showing that covalent attachment of PEG is important for the persistence of low uptake. The best results in reducing cell-associated fluorescence were obtained with a surface-modified PEG-PLA NC bearing a chain with 20000 MW. Increasing the percentage of PEG produced a reduction in marker association for a given PEG chain length. Moreover, when the PEG-containing poloxamer was simply adsorbed, marker association was dependent on the extent of dilution and the type of serum in the culture medium. Serum proteins, especially immunoglobulins, increased cell-associated fluorescence for PEG-adsorbed NC, but had very little effect on PEG-PLA NC. Marker association was only partially inhibited in the presence of cytochalasin B. The mechanisms of cell-NC interaction depended on the characteristics of the NC surface in each formulation. When the NC was physically separated from cells no diffusion of fluorescent marker in aqueous medium occurred. Nevertheless, collision-mediated transfer of DiD from NC to J774 cells was a non-negligible route of marker transfer, mainly for naked NC. However, this collision-mediated transfer was reduced for the PEG-PLA NC probably due to the restricted contact between NC and cells afforded by PEG steric hindrance at the surface.

Animals↗

Influence of experimental parameters on the characteristics of poly(lactic acid) nanoparticles prepared by a double emulsion method.

Nanoparticles were prepared by the double emulsion method (w/o/w), using methylene chloride as an organic solvent and polyvinyl alcohol (PVA) or human serum albumin (HSA) as a surfactant. Experimental parameters such as the preparation temperature, the solvent evaporation methods, the internal aqueous phase volume, the surfactant concentration and the polymer molecular weight were investigated for particle size, the zeta potential, the residual surfactant percentage and the polydispersity index. Preparation parameters leading to particles with well-defined characteristics such as an average size around 200 nm and a polydispersity index lower than 0.1 were identified. The conditions were optimized to ensure protein encapsulation: a cool temperature, a short processing time, a sufficient internal aqueous phase and careful washing. It appeared that the higher the surfactant concentration in the external aqueous phase was, the smaller the particles, the lower the polydispersity index and the higher the residual amount of surfactant were. For PVA or HSA, the agreement between the convenient surfactant concentration and its critical aggregation concentration could be emphasized. Otherwise, an increased polymer molecular weight led both to a slightly decreased particle size and to a lower polydispersity index. Moreover, multilayer absorption of PVA which does not depend on Poly(lactic-acid) molecular weight was exhibited. Finally, the zeta potential resulted from the polymer molecular weight and the residual PVA.

Drug Delivery Systems↗

Protein encapsulation within polyethylene glycol-coated nanospheres. I. Physicochemical characterization.

The development of injectable nanoparticulate "stealth" carriers for protein delivery is a major challenge. We have shown the possibility of entrapping human serum albumin (HSA) in polyethylene glycol (PEG)-coated monodisperse biodegradable nanospheres with a mean diameter of about 200 nm, prepared from amphiphilic diblock PEG-polylactic acid (PLA) copolymers, with loadings up to 9% (w/w). Microscopic techniques and surface analysis studies enabled us to prove that the protein was well entrapped and not adsorbed onto the particle surface. Zeta potential and water uptake studies corroborated that part of the PEG chains are located in the nanosphere matrix. Water uptake in the nanospheres was related to their chemical composition, i.e., the respective wt% of PEG and PLA in the matrix, and not on their fabrication procedure. The hydrophilic PEG blocks absorbed up to 130% (w/w) water, whereas PLA absorbed only about 10% (w/w). However, the rate of swelling at the beginning of the process was related to the structure of the matrix, more particularly to the manner in which PEG was disposed at the surface. Furthermore, it was shown that the PEG "brush" at the nanosphere surface drastically reduces HSA adsorption on the PEG-PLA nanospheres compared to the PLA ones.

Adsorption↗

Stealth PLA-PEG nanoparticles as protein carriers for nasal administration.

PURPOSE: The aim of the study was to encapsulate a model protein antigen, tetanus toxoid (TT), within hydrophobic (PLA) and surface hydrophilic (PLA-PEG) nanoparticles and to evaluate the potential of these colloidal carriers for the transport of proteins through the nasal mucosa. METHODS: TT-loaded nanoparticles, prepared by a modified water-in-oil-in-water solvent evaporation technique, were characterized in their size, zeta potential and hydrophobicity. Nanoparticles were also assayed in vitro for their ability to deliver active antigen for extended periods of time. Finally, 125I-TT-loaded nanoparticles were administered intranasally to rats and the amount of radioactivity recovered in the blood compartment, lymph nodes and other relevant tissues was monitored for up to 48 h. RESULTS: PLA and PLA-PEG nanoparticles had a similar particle size (137-156 nm) and negative surface charge, but differed in their surface hydrophobicity: PLA were more hydrophobic than PLA-PEG nanoparticles. PLA-PEG nanoparticles, especially those containing gelatine as an stabilizer, provided extended delivery of the active protein. The transport of the radiolabeled protein through the rat nasal mucosa was highly affected by the surface properties of the nanoparticles: PLA-PEG nanoparticles led to a much greater penetration of TT into the blood circulation and the lymph nodes than PLA nanoparticles. Furthermore, after administration of 125I-TT-loaded PLA-PEG nanoparticles, it was found that a high amount of radioactivity persisted in the blood compartment for at least 48 h. CONCLUSIONS: A novel nanoparticulate system has been developed with excellent characteristics for the transport of proteins through the nasal mucosa.

Administration, Intranasal↗