A multi-shell algorithm to reconstruct EIT images of brain function.

Electrical impedance tomography (EIT) may be used to image brain function, but an important consideration is the effect of the highly resistive skull and other extracerebral layers on the flow of injected current. We describe a new reconstruction algorithm, based on a forward solution which models the head as four concentric, spherical shells, with conductivities of the brain, cerebrospinal fluid, skull and scalp. The model predicted that the mean current travelling in the brain in the diametric plane for current injection from polar electrodes was 5.6 times less than if the head was modelled as a homogeneous sphere; this suggests that an algorithm based on this should be more accurate than one based on a homogeneous sphere model. In images reconstructed from computer-simulated data or data from a realistic saline-filled tank containing a real skull, a Perspex rod was localized to within 17% or 20% of the tank diameter of its true position, respectively. Contrary to expectation, the tank images were less accurate than those obtained with a reconstruction algorithm based on a homogeneous sphere. It is not yet clear if the theoretical advantages of this algorithm will yield practical advantages for head EIT imaging; it may be necessary to proceed to more complex algorithms based on numerical models which incorporate realistic head geometry. If so, this analytical forward model and algorithm may be used to validate numerical solutions.

Algorithms↗

Design and performance of the UCLH mark 1b 64 channel electrical impedance tomography (EIT) system, optimized for imaging brain function.

The UCLH Mark 1b is a portable EIT system that can address up to 64 electrodes, which has been designed for imaging brain function with scalp electrodes. It employs a single impedance-measuring circuit and multiplexer so that electrode combinations may be addressed flexibly using software. It operates in the relatively low frequency band between 225 Hz and 77 kHz, as lower frequencies produce larger changes during brain activity, and has a videocassette-sized headbox on a lead 10 m long, connected to a base box the size of a video recorder, and notebook PC, so that recordings may be made in ambulant subjects. Its performance was assessed using a resistor-capacitor network, and two saline-filled tanks-a cylindrical Perspex one and a latex one which contained a human skull. System signal-to-noise ratio was better than 50 dB and the maximum reciprocity error less than 10% for most frequencies. The CMMR was better than 80 dB at 38 kHz and a sponge, 20 mm across, which caused a local 12% impedance increase, was correctly localized in images. This suggests that the system has adequate performance to image impedance changes of 5-50% known to occur in the brain during normal activity, epilepsy or stroke; clinical trials to image these conditions are in progress.

Brain↗

A comparison of techniques to optimize measurement of voltage changes in electrical impedance tomography by minimizing phase shift errors.

In electrical impedance tomography, errors due to stray capacitance may be reduced by optimization of the reference phase of the demodulator. Two possible methods, maximization of the demodulator output and minimization of reciprocity error have been assessed, applied to each electrode combination individually, or to all combinations as a whole. Using an EIT system with a single impedance measuring circuit and multiplexer to address the 16 electrodes, the methods were tested on resistor-capacitor networks, saline-filled tanks and humans during variation of the saline concentration of a constant fluid volume in the stomach. Optimization of each channel individually gave less error, particularly on humans, and maximization of the output of the demodulator was more robust. This method is, therefore, recommended to optimize systems and reduce systematic errors with similar EIT systems.

Artifacts↗

Three-dimensional electrical impedance tomography of human brain activity.

Regional cerebral blood flow and blood volume changes that occur during human brain activity will change the local impedance of that cortical area, as blood has a lower impedance than that of brain. Theoretically, such impedance changes could be measured from scalp electrodes and reconstructed into images of the internal impedance of the head. Electrical Impedance Tomography (EIT) is a newly developed technique by which impedance measurements from the surface of an object are reconstructed into impedance images. It is fast, portable, inexpensive, and noninvasive, but has a relatively low spatial resolution. EIT images were recorded with scalp electrodes and an EIT system, specially optimized for recording brain function, in 39 adult human subjects during visual, somatosensory, or motor activity. Reproducible impedance changes of about 0.5% occurred in 51/52 recordings, which lasted from 6 s after the stimulus onset to 41 s after stimulus cessation. When these changes were reconstructed into impedance images, using a novel 3-D reconstruction algorithm, 19 data sets demonstrated significant impedance changes in the appropriate cortical region. This demonstrates, for the first time, that significant impedance changes, which could form the basis for a novel neuroimaging technology, may be recorded in human subjects with scalp electrodes. The final images contained spatial noise and strategies to reduce this in future work are presented.

Adolescent↗

Solving the forward problem in electrical impedance tomography for the human head using IDEAS (integrated design engineering analysis software), a finite element modelling tool.

If electrical impedance tomography is to be used as a clinical tool, the image reconstruction algorithms must yield accurate images of impedance changes. One of the keys to producing an accurate reconstructed image is the inclusion of prior information regarding the physical geometry of the object. To achieve this, many researchers have created tools for solving the forward problem by means of finite element methods (FEMs). These tools are limited, allowing only a set number of meshes to be produced from the geometric information of the object. There is a clear need for geometrical accurate FEM models to improve the quality of the reconstructed images. We present a commercial tool called IDEAS, which can be used to create FEM meshes for these models. The application of this tool is demonstrated by using segmented data from the human head to model impedance changes inside the head.

Algorithms↗

Electrical impedance tomography of human brain activity with a two-dimensional ring of scalp electrodes.

Previously, electrical impedance tomography (EIT) has been used to image impedance decreases in the exposed cortex of rabbits during brain activity. These are due to increased blood volume at the site of the stimulated cortex; as blood has a lower impedance than brain, the impedance decreases. During human brain activity similar blood flow changes have been detected using positron emission tomography (PET) and functional magnetic resonance imaging (fMRI). If blood volume also changes then the impedance of human cortex will change during brain activity; this could theoretically be imaged with EIT. EIT data were recorded from a ring of 16 scalp electrodes in 34 recordings in 19 adult volunteers before, during and after stimulation with (1) a visual stimulus produced by an 8 Hz oscillating checkerboard pattern or (2) sensory stimulation of the median nerve at the wrist by a 3 Hz electrical square wave stimulus. Reproducible impedance changes, with a similar timecourse to the stimulus, were seen in all experiments. Significant impedance changes were seen in 21 +/- 5% (n = 16, mean +/- SEM) and 19 +/- 3% (n = 18) of the electrode measurements for visual and somatosensory paradigms respectively. The reconstructed 2D EIT images showed reproducible impedance changes in the approximate region of the stimulated cortex in 7/16 visual and 5/18 somatosensory experiments. This demonstrates that reproducible impedance changes can be measured during human brain activity. The final images contained spatial noise; the reasons for this and strategies to reduce this in future are discussed.

Adult↗

Validation of a 3D reconstruction algorithm for EIT of human brain function in a realistic head-shaped tank.

Previous work has demonstrated that electrical impedance tomography can be used to image human brain activity during evoked responses, but two-thirds of the reconstructed images fail to localize an impedance change to the expected stimulated cortical area. The localization failure may be caused by modelling the head as a homogenous sphere in the reconstruction algorithm. This assumption may lead to errors when used to reconstruct data obtained from the human head. In this study a 3D reconstruction algorithm, based on a model of the head as a homogenous sphere, was characterized by simulating the algorithm model, the head shape and the presence of the skull in saline-filled tanks. EIT images of a sponge, 14 cm3 volume with a resistivity contrast of 12%, were acquired in three different positions in tanks filled with 0.2% saline. In a hemispherical tank, 19 cm in diameter, the sponge was localized to within 3.4-10.7% of the tank diameter. In a head-shaped tank, the errors were between 3.1 and 13.3% without a skull and between 10.3 and 18.7% when a real human skull was present. A significant increase in localization error therefore occurs if an algorithm based on a homogeneous sphere is used on data acquired from a head-shaped tank. The increased error is due to the presence of the skull, as no significant increase in error occurred if a head-shaped tank was used without the skull present, compared to the localization error within the hemispherical tank. The error due to the skull significantly shifted the impedance change within the skull towards the centre of the image. Although the increased localization error due to the skull is not sufficient to explain the localization errors of up to 50% of the image diameter present in the images of some human subjects, the future use of a realistic head model in the reconstruction algorithm is likely to reduce the localization error in the human images due to the presence of the skull.

Algorithms↗

Two-dimensional finite element modelling of the neonatal head.

Electrical impedance tomography (EIT) could allow the early diagnosis of infant brain injury following birth asphyxia. The purpose of this work was to determine the effect of variations in skull, scalp or cerebrospinal fluid (CSF) resistivity, as these vary in clinical conditions and could degrade image quality. These factors were investigated using finite element models of the adult and neonatal head. The results suggest that there is a wide range over which the resistivity of the neonatal skull has little effect on the sensitivity to a central impedance change. The scalp and CSF appear to shunt current away from the brain; when their resistivity was decreased from normal values, this shunting effect increased and caused a decrease in sensitivity to a central resistance change. The resistivity of neonatal skull has not, to our knowledge, been directly measured and will anyway vary within and between individuals; this work suggests that EIT will be relatively insensitive to variations in neonatal skull impedance.

Adult↗

Assessment and calibration of a low-frequency system for electrical impedance tomography (EIT), optimized for use in imaging brain function in ambulant human subjects.

An EIT system has been produced that has been optimized for imaging impedance changes with scalp electrodes during brain activity in ambulant subjects. It can record from 225 Hz to 65 kHz, has a small headbox on a lead 10 m long, and has software programmable electrode selection. In calibration experiments in a small cylindrical tank filled with potassium chloride solution and samples of cucumber, noise was less than 1% with averaging, and acceptable images were produced at frequencies down to 1800 Hz. This suggests that EIT can be performed at low frequencies, which are likely to give larger signals during brain activity. Future work will include trials in humans and improvement of the current source and isolation.

Brain Chemistry↗

Improvement of the positional accuracy of EIT images of the head using a Lagrange multiplier reconstruction algorithm with diametric excitation.

A novel algorithm for the reconstruction of dynamic images using diametric excitation has been developed. The algorithm is specifically designed to image impedance changes in the brain using boundary data obtained from scalp electrodes by incorporating a priori information. The a priori information is obtain by solving the forward problem using a finite-element model (FEM) which includes the discontinuity of the skull resistivity. The advantages with this new approach are that the sensitivity and accuracy of the location of the impedance changes are improved compared to methods based on adjacent excitation.

Algorithms↗