A balloon-dilatable pulmonary artery band in the dog. Results at one year.

Increased pulmonary blood flow and pulmonary hypertension are frequent problems in infants with congenital heart disease. Although the use of pulmonary artery banding to limit pulmonary blood flow has decreased, the procedure may still be beneficial in certain forms of complex heart disease. The ability to noninvasively relieve the obstruction caused by the band may significantly reduce later operative complexity or even avoid reoperation entirely. The present study evaluated the effectiveness of a balloon-dilatable pulmonary artery band. Twenty 1-week-old dogs had a band of an absorbable suture material (Vicryl; Ethicon, Inc., Somerville, N.J.) placed around the main pulmonary artery. Eight dogs underwent angioplasty 6 months after band placement and also underwent follow-up catheterizations 3 and 6 months after angioplasty. Balloon angioplasty acutely reduced both the right ventricle-pulmonary artery pressure gradient (from 37 +/- 7 mm Hg to 3 +/- 1 mm Hg, p less than 0.001) and the right ventricular systolic pressure (from 62 +/- 8 mm Hg to 32 +/- 2 mm Hg, p less than 0.01). At follow-up the gradient remained low, measuring 4 +/- 1 mm Hg at 3 months and 3 +/- 1 mm Hg at 6 months. Twelve dogs did not undergo balloon dilatation until 12 months after band placement to determine whether any obstruction persisted and whether the band could be relieved after long-term placement. These 12 dogs had progressive increases in right ventricle-pulmonary artery gradient, from 27 +/- 3 mm Hg at 6 months to 43 +/- 4 mm Hg at 12 months. Ten of these dogs underwent dilation 1 year after pulmonary artery band placement. This dilation significantly reduced the right ventricular outflow tract gradient (from 43 +/- 4 mm Hg to 1 +/- 1 mm Hg, p less than 0.001). The remaining two dogs underwent successful partial dilation of the band 12 months after placement. This study demonstrated that a pulmonary artery band of absorbable suture material maintains effective right ventricular outflow tract obstruction for at least 1 year. Additionally, the effect of the pulmonary band can be successfully and persistently relieved.

Animals↗

Balloon aortic valvuloplasty: results of the Valvuloplasty and Angioplasty of Congenital Anomalies Registry.

Data from 204 children and infants who underwent aortic balloon valvuloplasty between 1982 and 1986, reported to the Valvuloplasty and Angioplasty of Congenital Anomalies Registry, were reviewed. Valvuloplasty was successful in 192 of 204 children, reducing the peak systolic left ventricular ejection gradient from 77 +/- 2 to 30 +/- 1 mm Hg, p less than 0.001. The same degree of aortic stenosis gradients reduction was noted in both the 38 children under 1 year of age and in the 166 children over 1 year of age. Significant complications included death, aortic regurgitation and femoral artery thrombosis or damage. The incidence of these complications correlated with the age of the child, the ratio of valvuloplasty balloon size/anulus size, or both. The data suggest that percutaneous balloon valvuloplasty provides effective acute relief of valvar aortic stenosis in both infants and children. However, long-term follow-up data are necessary before balloon valvuloplasty can be established as a treatment of choice for congenital valvar aortic stenosis.

Aortic Valve↗

Pulsed Doppler assessment of left ventricular diastolic filling in children with left ventricular outflow obstruction before and after balloon angioplasty.

To assess left ventricular (LV) diastolic filling in children with pressure overload hypertrophy, 12 patients with LV outflow obstruction (7 with aortic valve stenosis and 5 with aortic coarctation) and 12 healthy, age-matched control subjects were examined. Each child underwent M-mode echocardiography and pulsed Doppler examination of the LV inflow. The patients with LV outflow obstruction had cardiac catheterization and balloon angioplasty. Their echo/Doppler examinations were performed in the catheterization laboratory before and immediately after balloon angioplasty. From the M-mode echocardiogram, the LV cavity dimensions and wall thicknesses, LV mass and shortening fraction were measured. The following measurements were made from the Doppler recording: peak velocities at rapid ventricular filling (peak E) and during atrial contraction (peak A), ratio of peak E to peak A velocities, total area under the Doppler curve, percent of the total Doppler area occurring in the first one-third of diastole (0.33 area fraction), percent of the total area occurring under the E wave (E area fraction), percent of the total area occurring under the A wave (A area fraction) and the ratio of E area to A area.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Flow cytometric analysis of lymphocyte subpopulations in infants with congenital heart disease.

Premortem diagnosis of the DiGeorge syndrome and its partial variants relies on the demonstration of a primary defect in cell-mediated immunity, generally in the setting of an infant with congenital heart disease, hypocalcemia, absence of a thymic shadow, and typical dysmorphic features. Although T-cell enumeration is considered a vital part of the diagnostic evaluation, no studies to date have addressed the issue of appropriate reference data in infants with congenital heart disease. We therefore undertook a prospective descriptive study of lymphocyte phenotype analysis in 27 nontransfused infants undergoing diagnostic cardiac catheterization. Striking differences were seen between patients and adult controls in means percentages and numbers of most lymphocyte subsets analyzed. Few differences were found in comparing the patient data to values for age-matched control infants without heart disease. The data are discussed with reference to published values for patients with partial DiGeorge syndrome. It is concluded that lymphocyte phenotype analysis in the diagnostic evaluation of patients with suspected DiGeorge syndrome must utilize appropriate reference values.

Antigens, Differentiation↗

Repair of truncus arteriosus in the neonate and young infant.

Infants with truncus arteriosus present a difficult management issue. Because of the high operative mortality, repair is often delayed beyond the first 3 to 6 months of age. We reviewed our experience with 11 neonates and young infants with truncus arteriosus undergoing repair (median age, 21 days). Five patients also had major truncal valve insufficiency, and 2 required valve replacement. Right ventricle-pulmonary artery continuity was established with a porcine valved conduit in 3 patients and an aortic or pulmonary homograft in 8. There was 1 operative death (9%; 70% confidence limits, 3%-22%) and 1 late death over a mean follow-up of 21 months (range, 4 to 32 months). Eight of the 9 late survivors are growing normally. Echocardiographic examination revealed normal ventricular function in all patients (mean shortening fraction, 39%). Doppler assessment demonstrated trivial prosthetic or homograft valve regurgitation in 7 patients and mild to moderate obstruction in 5 patients. This recent experience with repair of truncus arteriosus indicates that the operative risk is low even in the neonate. Repair in the first month of life should be recommended before the development of critical congestive heart failure or irreversible pulmonary vascular disease.

Abnormalities, Multiple↗

Aortic aneurysm after patch aortoplasty repair of coarctation: a prospective analysis of prevalence, screening tests and risks.

Twenty-nine children were evaluated prospectively for the presence of an aortic aneurysm at the repair site 1 to 19 years after patch aortoplasty repair of coarctation of the aorta. In each child, noninvasive evaluation included a chest X-ray film, computed tomography of the chest and two-dimensional echocardiography. The presence and size of an aortic aneurysm were determined quantitatively by measuring the ratio of the diameter of the thoracic aorta at the repair site to the diameter of the aorta at the diaphragm (aortic ratio). An aortic ratio of greater than or equal to 1.5 was judged abnormal and was shown to be significantly greater than the aortic ratio of a normal control group. An aortogram was obtained in each child if any noninvasive screening test was found to be abnormal. As assessed by the aortogram, the prevalence of aortic aneurysm was 24% in this patient group. The sensitivity of echocardiography and chest computed tomography for detecting an aneurysm was 71% and 66%, and the specificity 76% and 85%, respectively. The chest X-ray film was 100% sensitive and 68% specific in determining the presence of an aneurysm. Although the data are not statistically significant, they suggest that children undergoing patch aortoplasty as the primary procedure (rather than a reoperation after earlier resection), and children in whom a Dacron patch is utilized may be at increased risk for aneurysm formation.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Balloon valvuloplasty for recurrent aortic stenosis after surgical valvotomy in childhood: immediate and follow-up studies.

The immediate and intermediate-term effects of balloon valvuloplasty were assessed at cardiac catheterization in nine children with recurrent stenosis after a previous surgical aortic valvotomy. At valvuloplasty the patients ranged in age from 0.35 to 16 years and had undergone surgical valvotomy 0.3 to 12.5 years previously. Balloon valvuloplasty immediately reduced the peak systolic aortic stenosis gradient by 53%, from 88 +/- 9 (mean +/- SEM) to 41 +/- 6 mm Hg (p = 0.004). The left ventricular systolic pressure was reduced from 189 +/- 8 to 157 +/- 8 mm Hg (p = 0.001) and the left ventricular end-diastolic pressure from 17 +/- 1 to 14 +/- 2 mm Hg (p = 0.025). The heart rate and cardiac index remained unchanged. Before valvuloplasty, one patient had 1 + and two patients had 2+ aortic insufficiency. In six of nine patients, balloon valvuloplasty caused no change in the degree of valvular insufficiency. Two patients had a 1 + increase (from 0 to 1 + insufficiency in both), and one patient with no insufficiency developed 2+ aortic insufficiency. Elective follow-up catheterization was performed 0.8 to 2.5 years (mean 1.5 +/- 0.2) after valvuloplasty. At follow-up, the peak aortic stenosis gradient remained significantly reduced from the gradient before valvuloplasty (37 +/- 5 versus 85 +/- 10 mm Hg, p = 0.002). The gradient had not changed significantly from that measured immediately after valvuloplasty (37 +/- 5 versus 38 +/- 5 mm Hg, p = 0.75). At follow-up, aortic insufficiency had decreased from that immediately after valvuloplasty in three patients and had increased in two.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Therapeutic cardiac catheterization for pulmonary valve and pulmonary artery stenosis.

At C.S. Mott Children's Hospital, percutaneous balloon angioplasty for pulmonary valve or pulmonary artery stenosis accounts for approximately 40 per cent of all therapeutic transcatheter procedures performed in our laboratory. Percutaneous balloon valvuloplasty offers a highly successful nonsurgical approach to the treatment of children with isolated congenital valvar pulmonary stenosis. In these children, balloon valvuloplasty generally reduces the peak systolic pressure gradient by more than 50 per cent and should be considered the treatment of choice. Balloon angioplasty provides substantial anatomic and hemodynamic benefit in approximately 50 to 60 per cent of children with peripheral pulmonary artery stenosis. It is most often successful in treating naturally occurring pulmonary artery stenoses in children with tetralogy of Fallot. Since the surgical alternatives are difficult and often unsuccessful, balloon angioplasty offers a valuable form of treatment for many children with significant pulmonary artery stenosis or hypoplasia.

Adolescent↗

Accuracy of electrical impedance cardiography for measuring cardiac output in children with congenital heart defects.

This study determined whether noninvasive electrical impedance cardiography accurately measures systemic blood flow (cardiac output) in children with congenital heart defects. A total of 37 patients ranging in age from 2 to 171 months underwent complete right- and left-sided heart catheterizations that included simultaneous Fick and impedance measurement of cardiac output. Based on the diagnosis, 4 groups were formed consisting of a control group (n = 11) with no shunts, a group with intracardiac left-to-right shunting and an atrial septal defect (n = 7), another with a ventricular septal defect (n = 12) and an extracardiac left-to-right shunting with patent ductus arteriosus group (n = 7). Impedance values for systemic blood flow were compared with systemic and pulmonary blood flow obtained by the direct Fick method with measured oxygen consumption. The difference between impedance and Fick systemic blood flow was less than or equal to 5% in each of the 4 groups. The highest correlation between impedance and Fick systemic blood flow was with the atrial septal defect group (r = 0.89) and lowest with the ventricular septal defect and control (r = 0.69) groups. Fick pulmonary blood flow was significantly greater than impedance or Fick systemic flow in all 3 shunt groups. Impedance cardiography accurately measured systemic blood flow in children without shunts or valvular insufficiency. Likewise, systemic blood flow was accurately measured by impedance in the presence of intracardiac left-to-right shunts (atrial and ventricular septal defects) and extracardiac left-to-right shunts (patent ductus arteriosus).(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Circulation↗

A reversible pulmonary artery band: preliminary experience.

Pulmonary artery banding has become an infrequently used surgical technique. However, if a band was developed that could be relieved without the need for open heart surgery, it is likely that pulmonary artery banding would be used more frequently in the management of infants with congenital heart disease. Such a pulmonary artery band was placed in seven 1 week old mongrel puppies by using a loop of an absorbable suture material (Vicryl). One dog died at 2 months as a result of right ventricular failure. The remaining six dogs underwent cardiac catheterization and pulmonary balloon angioplasty at 6 months of age. After measuring pulmonary artery, right ventricular and aortic pressures and performing a right ventricular angiogram, balloon angioplasty of the band site was performed. A 20 mm balloon angioplasty catheter (Medi-Tech) was used in all dogs. Balloon angioplasty decreased right ventricular pressure from 101 +/- 19 to 42 +/- 3 mm Hg (p less than 0.05) and right ventricular systolic outflow tract gradient from 59 +/- 14 to 7 +/- 2 mm Hg (p less than 0.03), and increased the size of the band site from 8.7 +/- 0.03 to 14.9 +/- 0.5 mm (p less than 0.01). All dogs were recatheterized 2 months after angioplasty and were then killed for pathologic evaluation. At follow-up catheterization, right ventricular pressure, right ventricular outflow tract gradient and pulmonary artery size at the band site remained at the values obtained immediately after angioplasty. Postmortem examination demonstrated that there was no evidence of pulmonary artery damage. Although these studies are preliminary, they suggest that a reversible pulmonary artery band can be performed.

Angioplasty, Balloon↗

Comparison of single and double balloon valvuloplasty in children with aortic stenosis.

To compare the effectiveness of the single and double balloon techniques, the short-term results of percutaneous balloon valvuloplasty were assessed in two consecutive groups of children with valvular aortic stenosis. In 16 children (aged 3 months to 17 years) the single balloon technique was utilized; the ratio of balloon diameter to valve anulus diameter was 0.96 +/- 0.03 (mean +/- SEM). In 11 children (aged 3 months to 21 years) the double balloon technique was utilized in which two balloons are positioned across the valve and inflated simultaneously; the ratio of the balloon diameter sum to valve anulus diameter was 1.32 +/- 0.05. The groups were similar in age, weight, cardiac output, prevalvuloplasty gradient and valve anulus diameter. Overall, valvuloplasty reduced the peak systolic gradient by 53% from 80 +/- 4 to 38 +/- 3 mm Hg (p less than 0.0001). In the single balloon group the gradient decreased from 82 +/- 6 to 46 +/- 4 mm Hg (p less than 0.0001), whereas in the double balloon group the gradient decreased from 76 +/- 5 to 26 +/- 4 mm Hg (p less than 0.0001). The peak systolic gradient after valvuloplasty was 43% lower in the double balloon group (p less than 0.01). Furthermore, the single balloon technique reduced the gradient by an average of 43% compared with a 67% reduction with the double balloon technique (p less than 0.001). The short-term complications of valvuloplasty were similar, with an increase in aortic insufficiency occurring in three children in each group.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Concealed paroxysmal atrioventricular block: diffuse congenital atrioventricular conduction system disorder with nonpropagated His bundle depolarizations.

A 2 1/2-year-old girl with bradycardia and left bundle branch block at birth began to experience "night cries" when deeply asleep. Electrophysiological study demonstrated congenital diffuse atrioventricular conduction disease with concealed paroxysmal atrioventricular block, nonpropagated His bundle depolarizations, severe sinus node abnormality, and a low atrioventricular junctional escape rhythm with probable reciprocation. After pacemaker implant, the "night cries" ceased.

Bradycardia↗