PubMed Health⌕ Search

Biomedical subjects

R H Ireland

Publications and source records attributed to R H Ireland.

6 recordsLinked to original sources

Prolonged cardiac repolarisation during spontaneous nocturnal hypoglycaemia in children and adolescents with type 1 diabetes.

AIMS/HYPOTHESIS: It has been postulated that hypoglycaemia-related cardiac dysrhythmia and, in particular, prolonged cardiac repolarisation, may contribute to increased mortality rates in children and adolescents with type 1 diabetes. METHODS: We examined the prevalence of prolonged QT interval on ECG during spontaneous hypoglycaemia in 44 type 1 diabetic subjects (aged 7-18 years), and explored the relationships between serial overnight measurements of QT interval corrected for heart rate (QTc) and serum glucose, potassium and epinephrine levels. Each subject underwent two overnight profiles; blood was sampled every 15 min for glucose measurements and hourly for potassium and epinephrine. Serial ECGs recorded half-hourly between 23.00 and 07.00 hours were available on 74 nights: 29 with spontaneous hypoglycaemia (defined as blood glucose <3.5 mmol/l) and 45 without hypoglycaemia. RESULTS: Mean overnight QTc was longer in females than in males (412 vs 400 ms, p=0.02), but was not related to age, diabetes duration or HbA(1)c. Prolonged QTc (>440 ms) occurred on 20 out of 74 (27%) nights, with no significant differences between male and female subjects, and was more prevalent on nights with hypoglycaemia (13/29, 44%) than on nights without (7/45, 15%, p=0.0008). Potassium levels were lower on nights when hypoglycaemia occurred (minimum potassium 3.4 vs 3.7 mmol/l, p=0.0003) and were inversely correlated with maximum QTc (r=-0.40, p=0.03). In contrast, epinephrine levels were not higher on nights with hypoglycaemia and were not related to QTc. CONCLUSIONS/INTERPRETATION: In young type 1 diabetic subjects, prolonged QTc occurred frequently with spontaneous overnight hypoglycaemia and may be related to insulin-induced hypokalaemia.

Adolescent↗

Changes in cardiac repolarization during clinical episodes of nocturnal hypoglycaemia in adults with Type 1 diabetes.

AIMS/HYPOTHESIS: Experimental hypoglycaemia leads to abnormal cardiac repolarization manifest by a lengthened QT interval and caused by adrenergic stimulation. However it is less clear whether spontaneous clinical episodes lead to similar changes. We have therefore measured cardiac ventricular repolarization and counterregulatory responses in patients with Type 1 diabetes during hypoglycaemic and euglycaemic nights. METHODS: We studied 22 patients with Type 1 diabetes (mean age 40.4+/-17.2 years, duration of diabetes 17.2+/-9.3 years, HbA1c 8.2+/-1.2% overnight). Measurements were taken hourly of blood glucose, plasma potassium, catecholamines and high resolution electrocardiograms. RESULTS: Hypoglycaemia (blood glucose level <2.5 mmol/l) occurred on 7 of the 22 nights. During overnight hypoglycaemia, QTc interval increased by 27 ms (+/-15) above baseline, compared with 9 ms (+/-19) during nights with no nocturnal hypoglycaemia (p=0.034, 95%CI 2, 35). Adrenaline increased by 0.33 nmol/l (+/-0.21) above baseline during hypoglycaemia, compared with -0.05 nmol/l (+/-0.08) during euglycaemia (p=0.001, 95%CI 0.19, 0.56 nmol/l). There was no significant difference between potassium, and noradrenaline concentrations between the two groups. CONCLUSION/INTERPRETATION: QTc interval lengthens significantly during spontaneous nocturnal hypoglycaemia. Increases are generally less than those observed during experimental hypoglycaemia and could reflect attenuated sympathoadrenal responses during clinical episodes. The clinical relevance of these changes is uncertain but is consistent with the hypothesis that clinical hypoglycaemia can cause abnormal cardiac repolarization and an attendant risk of cardiac arrhythmia.

Adult↗

Towards magnetic detection electrical impedance tomography: data acquisition and image reconstruction of current density in phantoms and in vivo.

The objective of magnetic detection electrical impedance tomography (MD-EIT) is to reconstruct in vivo images of conductivity from magnetic field measurements taken around the body. MD-EIT is performed by applying an alternating current, at one of a range of frequencies, to a conducting object through a pair of electrodes fixed to the surface of the object. Magnetic field measurements recorded by search coils at a number of positions around the object are used to determine the current distribution that is generating the magnetic field. From this distribution, a conductivity map of a cross-section of the object can be reconstructed. This paper describes the development of an MD-EIT data acquisition system and discusses the related image reconstruction issues. The ill-conditioned nature of the inverse problem is examined and a number of image reconstruction methods are compared. The technical feasibility of MD-EIT data collection and image reconstruction is demonstrated with example images of current density from both phantom and human data.

Algorithms↗

Measurement of high resolution ECG QT interval during controlled euglycaemia and hypoglycaemia.

During hypoglycaemia, typically there is a change in the surface ECG characterized by a flattened and prolonged T wave, often accompanied by a fused U wave. The QT interval is a useful parameter for quantifying the ECG morphology. However, reliable measurement of QT is not straightforward, particularly for hypoglycaemic ECG morphology. The objective of this study was to compare the ability of two methods of QT measurement to distinguish between ECGs recorded during euglycaemia and hypoglycaemia. The first method involves manually setting the intersection of the isoelectric line and the T wave or, where this is not possible, the nadir between the T and U wave. The second method is semi-automatic and fits a tangent to the point of maximum gradient on the downward slope of the T wave. Two independent observers used both methods to measure the QT for high resolution ECG data recorded during a study of 17 non-diabetic subjects undergoing controlled euglycaemia and hypoglycaemia. Using the mean results of the two observers, the mean +/- SD increase in heart rate corrected QT, QTc, for ECGs recorded during euglycaemia and hypoglycaemia was 32 +/- 25 ms for the non-tangent method and 60 +/- 24 ms for the tangent method. Therefore, the tangent method provides greater distinction between ECGs recorded during euglycaemia and hypoglycaemia than the non-tangent method. A potential clinical application could be the non-invasive detection of impending hypoglycaemia at night, which would be of significant benefit to adults and young children with diabetes.

Adult↗

Magnetic impedance tomography.

Tissue can be characterized by its electrical impedance, especially if measurement can be extended over a range of frequencies. Recently, there has been a great deal of interest in imaging the distribution of electrical impedance through the technique of electrical impedance tomography (EIT). However, EIT has a number of practical problems relating to the placement of electrodes on the body. Such contacts are not required to collect magnetic field data around an object through which current is flowing and thus this approach may be more practical than EIT in the clinical environment. This paper describes the technique of magnetic impedance tomography (MIT), which allows reconstruction of the current distribution from magnetic field measurements. The reconstruction techniques used to generate the images and the prototype data collection system are described. Images produced using data collected from discrete and distributed current phantoms and the thorax during human respiration are presented.

Electric Impedance↗

Design of a summary screen for an ICU patient data management system.

The paper describes a used-centred design for the summary screen of a computerised ICU patient data management system (PDMS). The screen also forms the resting state display, or default screen, and provides the principal navigation tool to other functionality within the system. The design process identified the most frequent potential users of this screen to be the nurses. Their tasks and the information resources required to perform them were analysed. The analysis identified that the nurses' main task of planning and implementing patient care required an awareness of a set of physiological parameters which provided an overview of the patient's general condition. Novel formats are proposed for displaying the trends in physiological parameters and these have been incorporated into a proposed screen design. These display formats have been evaluated by ICU nurses; they were adjudged to be clear, relevant, easy to learn and simple to use. Nurses considered the content of the screen, and the display formats used, to be suitable for maintaining an awareness of a patient's state during routine patient management.

Evaluation Studies as Topic↗