PubMed Health⌕ Search

Biomedical subjects

R H M Goossens

Publications and source records attributed to R H M Goossens.

11 recordsLinked to original sources

Stability of sitting postures: the influence of degrees of freedom.

Observational studies of sitting have shown that, during spontaneous sitting, people adopt a variety of postures. Various researchers have formulated theories to explain why people adopt their sitting postures. Branton (1969) hypothesized that there is continual need for postural stability while sitting. Dempster (1955) stated that additional stability could be obtained through temporarily closing chains of body segments, or, in other words, through decreasing the number of degrees of freedom of the body. The present study elaborates on Dempster's theory. The aim of this study was to determine the influence of the degrees of freedom of the body on postural stability in sitting postures. For 21 different sitting postures, the total number of degrees of freedom was determined. Postural sway, a measure for postural stability, was determined using a 3D motion and position measurement system with ten healthy subjects. This study shows that the mean path length at the level of the second thoracic vertebra (PL0.05), a measure derived from postural sway, increases significantly (p < 0.0001) with an increase of the number of degrees of freedom of the body (DoFB). Closer examination of the data showed that a model taking into account only the degrees of freedom of the lumbar and thoracic spine and pelvis seems to be a better predictor of postural sway than the total number of degrees of freedom of the body.

Biomechanical Phenomena↗

Application of ergonomic guidelines during minimally invasive surgery: a questionnaire survey of 284 surgeons.

BACKGROUND: This study aimed to obtain an answer for the question: Are ergonomic guidelines applied in the operating room and what are the consequences? METHODS: A total of 1,292 questionnaires were sent by email or handed out to surgeons and residents. The subjects worked mainly in Europe, performing laparoscopic and/or thoracoscopic procedures within the digestive, thoracic, urologic, gynecologic, and pediatric disciplines. RESULTS: In response, 22% of the questionnaires were returned. Overall, the respondents reported discomfort in the neck, shoulders, and back (almost 80%). There was not one specific cause for the physical discomfort. In addition, 89% of the 284 respondents were unaware of ergonomic guidelines, although 100% stated that they find ergonomics important. CONCLUSIONS: The lack of ergonomic guidelines awareness is a major problem that poses a tough position for ergonomics in the operating room.

Adult↗

Artificial midline-fascia of the human abdominal wall for testing suture strength.

To reduce testing of human abdominal wall closure-modalities in test animals, a fibre reinforced rubber with identical mechanical properties compared to the human midline fascia (linea alba: LA) was developed. The microscopic structure of the human LA, stress-strain behaviour, maximum tensile force and macroscopic failure mechanism in tensile tests with human LA were defined as indicators for the required properties of the fibre reinforced rubber. A composite consisting of latex rubber and cotton fibres was developed that shows mechanical properties comparable to the human abdominal wall. The results of the tensile tests on sutured artificial LA were highly similar to those performed on sutured human LA. The material presented in this study is proposed as a substitute for human and animal tissues presently used to test suture techniques. A protocol for an approach to develop artificial fibrous soft tissue like fascie and tendon was drawn up.

Abdominal Muscles↗

Sensitivity for pressure difference on the ischial tuberosity.

Although research on sitting and sitting postures has been done for decades, the field of the subjective feeling of comfort or discomfort during sitting is still an unexplored field. On the basis of those studies some manufacturers claim enhanced subjective comfort because of pressure-relieving qualities of the seat cushions. The question is: does a relatively small pressure reduction enhance comfort? Before that question can be answered, the sensitivity for pressure differences applied to the skin must first be determined. The aim of this study was therefore, to determine the sensitivity of the ischial tuberosity for pressure difference in a healthy population. For this study five males and five females aged between 19 and 30 years with no exercise-induced muscle ache were selected. The (Deltaa) was determined for which stimulus (a + Deltaa) was judged as exceeding stimulus (a) in 50% of the trials. This value was called (Deltaa0.5) and was determined with an adapted simple up - down method with forced choice. Two different values for (a) were used: (a) = 13.3 kPa and (a) = 26.5 kPa and the pressure was applied with two different contact surface with diameters of 10 mm and 20 mm. For (a) = 26.5 kPa and d = 10 mm a Deltaa0.5 = 2.7 kPa was found. For (a) = 26.5 kPa and d = 20 mm a Deltaa0.5 = 3.5 kPa was found. For (a) = 13.3 kPa and d = 20 mm a Deltaa0.5 = 1.9 kPa was found.

Adult↗

Ergonomic problems encountered by the medical team related to products used for minimally invasive surgery.

BACKGROUND: The aim of this study is to gain insight into the problems encountered by the medical team related to products used for minimally invasive surgery. METHODS: An inventory was made of the problems encountered during 12 endoscopic operations performed in one city hospital (Eindhoven, the Netherlands). After the observation, a questionnaire was distributed to all medical staff involved. RESULTS: All categories of personnel had physical, perceptional, and cognitive problems, especially surgeons, residents, and the sterile operation nurse. The main causes were the positioning of apparatus and staff, work clothing, and the limited reach of apparatus and/or instruments. Of the questionnaires, 80% were returned: 50% of the medical staff experienced perceptional problems and 63% had physical discomfort during the surgical procedure. CONCLUSION: The diversity of problems observed and/or reported by the staff during minimally invasive surgery decrease the comfort, efficiency, and safety of the operating-room work environment. Therefore, a new design approach is needed for MIS products in order to address the problems that occur with the current equipment.

Ergonomics↗

Improvement of foot pedals used during surgery based on new ergonomic guidelines.

BACKGROUND: This study aims to create new ergonomic guidelines for the design of foot pedals used during surgery. METHODS: Observations in the operating room, a questionnaire among 45 laparoscopic surgeons/residents, an ergonomic literature study, and clog measurements were used to assess the problems occurring during use and to compile new guidelines for foot pedals. Based on these guidelines a new foot pedal was designed and a prototype was manufactured. RESULTS: During the surgical procedure 91% of the subjects occasionally loses contact with the foot pedal, which 56% experience as very annoying. All subjects think that the current foot pedals obstruct their freedom of movement; 75% occasionally hit the wrong switch and 53% experience physical discomfort in their legs and/or feet. Therefore, 93% of the subjects would like to control the diathermy in a different way. The new prototype of a foot pedal was evaluated in a pilot test and proved to be ergonomically better than the currently used foot pedals. CONCLUSION: The new guidelines for foot pedals result in an ergonomic improvement in their design.

Equipment Design↗

Free shoulder space requirements in the design of high backrests.

The objective of this study was to determine the influence of scapular support on the effects of lumbar support and to prove that a high and straight backrest is inappropriate. In literature the importance of a lumbar support is noted, although data about optimal dimensions is an under-researched topic and in earlier studies on force distribution and muscle activity the backrest had a fixed form. The lumbar support is needed to maintain the lumbar lordosis but no studies deal with the question of the precise dimensions of the backrest at shoulder level. With a specially designed apparatus, forces on shoulder and seat were measured separately, and the force on the pelvis calculated, while varying seat and backrest inclination within the range from 0 degrees to 17 degrees. Seat-to-backrest angle (at the level of lumbar support) was kept constant at 90 degrees. The distance between the tangent to the lumbar support and the parallel tangent to the scapular support was varied from 0, 2, 4, 6 and 8 cm. This distance is called the free shoulder space. Electromyography was measured at the erector spinae at the levels of the L1, T8 and T5 vertebrae. For all seat angles, a free shoulder space of d=0 cm resulted in the highest back muscle activity. In agreement with the biomechanical model, EMG activity reduced with an increase of seat tilt and increase of free shoulder space. With increasing free shoulder space, a larger part of the total backrest force was carried by the lumbar support. This study shows that a high and straight backrest overrules lumbar support. Offering free shoulder space of at least 6 cm reduces back muscle activity and allows for lumbar support.

Adult↗

Improvement of the laparoscopic needle holder based on new ergonomic guidelines.

BACKGROUND: The aim of this study is to create new ergonomic guidelines for the design of laparoscopic needle holders. METHODS: An ergonomic literature study, observations in the operating room, handle-shaft angle measurements, and anthropometric data were used to compile new ergonomic criteria, specified to the function of a laparoscopic needle holder. Based on these guidelines a new needle holder was designed. The prototype and three currently available needle holders were evaluated according to the new guidelines. In addition, a pelvi-trainer test was done to measure the extreme wrist excursions. RESULTS: The ergonomic evaluation of three commonly used handles and the new prototype indicate that the new handle is an ergonomic improvement in the field of laparoscopic needle holders: only the new handle satisfies all criteria. This is validated by the results of the pelvi-trainer test, which showed that the new prototype significantly (p <0.001) reduced the extreme wrist excursions. CONCLUSION: The new design guidelines for a laparoscopic needle holder result in an ergonomic improvement of the instrument.

Equipment Design↗

Assessment of the ergonomically optimal operating surface height for laparoscopic surgery.

PURPOSE: The aim of this study was to find the ergonomically optimal operating surface height for laparoscopic surgery in order to reduce discomfort in the upper extremities of the operators and the assistants. The operating surface height was defined as the level of the abdominal wall of a patient with pneumoperitoneum. MATERIALS AND METHODS: Two pelvi-trainer tests were performed. One test was performed on six different operating surface heights. The (extreme) joint excursions of the shoulder, elbow, and wrist were measured by a video analysis method. Another test was performed by holding a laparoscope for 15 minutes while an electromyelograph of the biceps brachii was made. The results of both tests were evaluated subjectively by a questionnaire. RESULTS: The ergonomically optimal operating surface height lies between a factor 0.7 and 0.8 of the elbow height of the operator/assistant. At this height, the joint excursions stay in the neutral zone for more than 90% of the total manipulation time, and the activity of the biceps brachii when holding the laparoscope stays within 15% of the maximum muscle activity. CONCLUSIONS: The operating surface height influences the (extreme) upper joint excursions of the surgeon. The ergonomically optimal operating surface height reduces the discomfort in the shoulders, back, and wrists of the surgeon during laparoscopic surgery. This optimal table height range for laparoscopic surgery is lower than those currently available.

Electromyography↗

Evaluation of the usability of two types of image display systems, during laparoscopy.

BACKGROUND: This study was performed to assess the optimal display location of a flat-screen monitor for laparoscopy. It was also performed to assess the posture (objective), opinion, and preference (subjective) of subjects using a flat-screen monitor positioned in the optimal display location and a cathode-ray tube monitor on a tower next to the operating table (current situation). METHODS: Twelve surgeons performed cholecystectomies using the two display systems alternately. The postures of the operator and the assistant were assessed by an infrared video analysis system. RESULTS: The posture of the assistant is significantly better when using a flat-screen monitor [more neutral head flexions (p = 0.036) and neutral neck torsions (p = 0.012)]. No significant differences were found for the posture of the operator. The operators and assistants felt more comfortable when using a flat-screen monitor (p = 0.008) and they preferred this display to the use of a monitor on a tower. CONCLUSIONS: The use of flat-screen monitors is better for the physical and psychological comfort of the users, even though the technical performance is inferior in comparison with that of regular monitors.

Cholecystectomy↗

Improved usability of a new handle design for laparoscopic dissection forceps.

BACKGROUND: Recent studies have shown that the shape of most instrument handles causes user discomfort and that none of the handles currently available on the market satisfies all ergonomic criteria. Therefore, we designed a handle with improved usability; i.e., it is easier to manipulate and its use entails less risk of injury for the operator. The aim of this study was to demonstrate that the intended improvements of the new design were successful. METHODS: Six handles representative of the types that are currently available were compared with the new version. Eight surgeons used the seven handles during a precision task and a rough task in a pelvi-trainer. A questionnaire and video analyses were used to assess the usability of the handles. RESULTS: Based on the responses to the questionnaire, we determined that there were significant differences between the new handle and the Aesculap handle (means of rotation and angle between handle and shaft). No significant differences were found between the new handle and the five other handles. The video analyses (documenting extreme vs neutral wrist excursions) showed significant differences between the new handle and the six other handles. CONCLUSION: Compared to the six existing handles, the new handle has significantly improved usability; in particular, its hinged design obviates the need to make extreme wrist excursions.

Adult↗