The influence of xenon on regulation of the autonomic nervous system in patients at high risk of perioperative cardiac complications.

BACKGROUND: As xenon anaesthesia (XE) does not produce haemodynamic depression its use may be of benefit in patients at high risk of intraoperative haemodynamic instability and perioperative cardiac complications. XE (n=22) was compared with total i.v. anaesthesia (TIVA, n=22) for differences in autonomic regulation, peri- and postoperative performance. METHODS: Patients undergoing abdominal aortic surgery were studied at five events: T1: baseline awake; T2: anaesthesia induction; T3: before aortic cross-clamping; T4: after aortic cross-clamping; T5: after aortic declamping. T3-T5: end-tidal xenon concentration 60 (5)%. Intraoperative analysis: heart rate, heart rate variability, blood pressure and cardiac output. Postoperative analysis: 24 h Holter ECG, intensive care unit and hospital stay, and patient's outcome after 6 months. RESULTS: XE in contrast to TIVA increased parasympathetic and decreased sympathetic activity. Median low to high frequency decreased significantly in the XE group after start of XE (P<0.05) and remained significantly lower during all events after start of XE as compared with TIVA (P=0.0001). After start of XE heart rate of these patients was significantly lower as compared with TIVA (P=0.04). Cardiac output increased significantly in TIVA after aortic declamping (P<0.05). Outcome parameters did not differ significantly between groups. CONCLUSIONS: XE patients demonstrated lower sympathetic and higher parasympathetic activity as compared with TIVA patients. This was reflected by significant differences in haemodynamics but did not correlate with a better postoperative outcome. Thus, it remains controversial whether XE provides benefits in high risk patients.

Aged↗

Bispectral index-controlled anaesthesia for electroconvulsive therapy.

BACKGROUND: The suggested induction dose of methohexital for electroconvulsive therapy (ECT) varies widely influencing efficacy of ECT and safety of anaesthesia. Bispectral index (BIS), a monitor of consciousness, may be useful to assure adequate hypnosis with optimized methohexital dose. METHODS: Patients with medically resistant major depression (ICD10), scheduled for multiple ECT's, were studied. Depth of anaesthesia was BIS controlled. ECT was not performed until BIS dropped below 50. Initially anaesthesia was induced with methohexital 1.0 mg kg(-1), and stepwise reduced by 0.1 mg kg(-1) during consecutive treatments. If BIS did not drop below 50, the methohexital was supplemented by further boluses of 0.5 mg kg(-1), until the desired level of hypnosis was reached. The adequacy of the anaesthetic recommendation for methohexital (1.0-1.5 mg kg(-1)) as well as the psychiatric recommendation (0.75-1 mg kg(-1)) was investigated. RESULTS: One-hundred and nine ECT's in 14 patients were studied. The recommended anaesthetic dose (1.0-1.5 mg kg(-1)) was inadequate in 40% of the treatments, with 12% exceeding 1.5 mg kg(-1), and 28% below 1.0 mg kg(-1). Psychiatric recommendation (0.75-1.0 mg kg(-1)) was inadequate in 49%, with 39% exceeding 1.0 mg kg(-1) and 10% undershooting at 0.75 mg kg(-1). CONCLUSIONS: Methohexital for ECT showed a great variability, exceeding as well as undershooting the dosage recommendations widely. BIS monitoring may be useful to secure adequate hypnosis during muscle relaxation and treatment and may optimize ECT efficacy.

Aged↗

Pseudocholinesterase activity increases and heart rate variability decreases with preoperative anxiety.

BACKGROUND AND OBJECTIVE: The objective of this study was to determine the influence of preoperative anxiety on the activity of plasma cholinesterase and heart rate (HR) variability. METHODS: A total of 50 subjects were studied, 25 male patients one day preoperatively and 25 male volunteers without surgical intervention as a control group. Blood samples were taken to determine plasma cholinesterase activity. HR variability was recorded for a period of 256 beat-to-beat intervals and analysed by frequency domain analysis into very low frequency (VLF: 0.02-0.04 Hz), low frequency (LF: 0.04-0.15 Hz) and high frequency (HF: 0.15-0.4 Hz). LF/HF ratio and total power over the 0.02-0.4 Hz range were calculated. Anxiety levels were assessed using the hospital anxiety and depression scale, the self-rating anxiety scale and a visual analogue scale. RESULTS: The patient group had significantly higher anxiety scores. Plasma cholinesterase activity was significantly higher in patients vs. controls (6646 vs. 5324 units L(-1)). Total power, LF and HF were significantly lower in the patients (1489 vs. 2581 ms2; 656 vs. 1186 ms2; 491 vs. 964 ms2, respectively). CONCLUSIONS: Preoperative anxiety increases plasma cholinesterase activity and decreases HR variability.

Adolescent↗

Comparison of xenon-based anaesthesia compared with total intravenous anaesthesia in high risk surgical patients.

Xenon, a noble gas with anaesthetic and analgesic properties, has gained renewed interest due to its favourable physical properties which allow a rapid emergence from anaesthesia. However, high costs limit its use to a subset of patients who may benefit from xenon, thereby offsetting its costs. To date, there are only limited data available on the performance of xenon in high risk patients. We studied 39 patients with ASA physical status III undergoing aortic surgery. The patients were randomly assigned to either a xenon (Xe, n = 20) or a TIVA (T, n = 19) group. Global cardiac performance and myocardial contractility were assessed using transoesophageal echocardiography, and myocardial cell damage with troponin T and CK-MB. Echocardiographic measurements were made prior to xenon administration, following xenon administration, and after clamping of the abdominal aorta, after declamping and at corresponding time points in the TIVA group. Laboratory values were determined repeatedly for up to 72 h. Data were analysed using two-way anova factoring for time and anaesthetic agent or with ancova comparing linear regression lines. No significant differences were found in global myocardial performance, myocardial contractility or laboratory values at any time during the study period. Mean (SEM) duration of stay on the ICU (xenon: 38 +/- 46 vs. TIVA 25 +/- 15 h) or in hospital (xenon: 14 +/- 12 vs. TIVA 10 +/- 6 days) did not differ significantly between the groups. Although xenon has previously been shown to exert superior haemodynamic stability, we were unable to demonstrate an advantage of xenon-based anaesthesia compared to TIVA in high risk surgical patients.

Aged↗

[Procedure optimization in hospital management].

Starting January 1st 2004 the German diagnosis-related group (DRG) system was established for in-patient cases. Consequently, the detection and realization of cost-saving potentials are becoming more and more important. For a successful future, efficient allocation of resources is essential. Economically, anaesthesia-related time delays during perioperative work-flow should be minimized. Since numerous entities contribute to perioperative care, it is extremely complex to analyze and optimize this process flow. In this publication single steps leading to an optimized perioperative process flow will be presented: documentation of predefined time points, calculation of relevant time intervals and analysis of key numbers for complex settings. Single steps of the given process analysis will be demonstrated using data from surgical patients at the University Hospital Schleswig-Holstein, Campus Kiel. The attached data collection sheets can be used by interested hospital departments and are meant to serve as a template for further process analyses. Based on the shown analysis, an example will be given to develop an optimized work-flow as a standard operating procedure (SOP). The implementation of the SOP module in an interdisciplinary clinical pathway (CP), which defines efficient medical care from admission to discharge, is mainly responsible for decreased process costs but increased quality of care.

Anesthesia Department, Hospital↗

Effect of xenon anaesthesia on accuracy of cardiac output measurement using partial CO2 rebreathing.

Cardiac output (CO) determination based on partial CO(2) rebreathing has recently been introduced into clinical practice. The determination of flow is crucial for exact CO readings and the physical properties of xenon, i.e. high density and viscosity, may influence flow readings. This study compared echocardiography-derived CO measurements with the partial rebreathing method during total intravenous (TIVA) vs. xenon-based anaesthesia. Thirty-nine patients ASA physical status III undergoing aortic reconstruction were randomly assigned to receive either xenon (Xe, n = 20) or TIVA (T, n = 19) based general anaesthetic. Paired measurements were taken before xenon administration, after xenon administration, before and after clamping of the abdominal aorta and after declamping and at corresponding time points in the TIVA group. Data were analysed with a Bland-Altmann plot. Bias and precision were acceptable and comparable before xenon administration (T 0.54 +/- 0.92 l.min(-1) vs. Xe 0.11 +/- 1.1 l.min(-1)), but after xenon administration CO was largely overestimated by partial CO(2) rebreathing (T 0.04 +/- 0.91 l.min(-1) vs. Xe -4.0 +/- 2.1 l.min(-1)). In the TIVA group, bias and precision after declamping increased significantly (P < 0.01) compared to all time points except baseline. In its current application, the NICO cardiac output monitor appears to be inappropriate for determination of CO during xenon based anaesthesia.

Aged↗