PubMed Health⌕ Search

Biomedical subjects

R Hartz

Publications and source records attributed to R Hartz.

11 recordsLinked to original sources

Annular and leaflet augmentation in Noonan's syndrome with dysplastic pulmonary valve.

Two patients with dysplastic pulmonary valves associated with Noonan's syndrome successfully underwent leaflet augmentation with pericardial membrane and annular enlargement with preservation of valve competence. Both patients are doing well at 36 and 37 months, respectively, postoperatively. Echocardiography and clinical assessment showed gradients of 12 and 16 mmHg, respectively, and negligible pulmonary valve insufficiency. The surgical technique is simple and provides an attractive alternative in patients with dysplastic pulmonary valve and small pulmonary orifice and annulus.

Child, Preschool↗

9:45-10:00. Superimposition of EBCT Determined Coronary Calcium Deposits onto Myocardial PET Perfusion Images by Rubidium-82 and Nitrogen-13 Ammonia for Assessment of Flow Limiting Defects.

Calcium localization by Electron Beam CT (EBCT) in the coronary arteries is becoming an important non-invasive method for screening asymptomatic patients for early coronary atherosclerosis. However, the relationship between coronary artery calcium deposits and myocardial perfusion abnormalities has not been established. We have developed software to superimpose location of coronary calcium by EBCT onto PET myocardial perfusion images, so that we can determine the role of location and amount of calcium in the arteries to flow-limiting perfusion defects by PET.EBCT and PET transaxial images are each first converted to three-dimensional arrays of 1 mm voxels. The resulting two image volumes sets are displayed so that a vertical line can be drawn from the clavicle to the spine for proper rotation of the body. The rotated images are then displayed superimposed and are shifted in the vertical, horizontal, and the long axis directions to co-register the EBCT and PET images. The EBCT images are windowed for calcium Houndsfield numbers and calcium location is added to the PET images as a maximum intensity value in the image. The modified PET image volume is then translated back to the PET data format and reprocessed using cardiac analysis software such that the calcium location is superimposed on the PET myocardial perfusion images.Preliminary results of the PET-EBCT superimposition program correlate with location of coronary calcium by EBCT and PET perfusion defects following stress. This technique may be useful for identifying flow-limiting calcium deposits in the coronary arteries.

Journal Article↗

Endoscopic thoracic sympathectomy: evaluation of pulsatile laser, non-pulsatile laser, and radiofrequency-generated thermocoagulation.

We describe a modified technique for percutaneous denervation of the thoracic sympathetic chain by laser to treat selected cases of sympathetic causalgia of the upper extremities. The technique involves transpleural ablation with laser under thoracoscopic guidance through the second or third intercostal space-anterior axillary line. We also compare four different modalities of endoscopic denervation: A xenon chloride excimer laser (308 nm, 35 mJ/pulse, 20 pulses/sec, 2.2 mm catheter tip), CO2 laser (14 W, CW, 2 mm spot size), Nd:YAG laser (88 W, CW, 3 mm spot size), and radiofrequency-generated thermocoagulation (3 W, CW, 2.1 mm catheter tip) by performing bilateral thoracic sympathectomy on 12 mongrel dogs (three dogs each). Criteria analyzed included duration of exposure, power density, total energy output, laser penetration and spread, gross morphology, and scanning electron microscopy (SEM) of the destroyed neural tissue. Total ablation of the inferior segment of the stellate ganglion and the T1-T2 nerve roots by excimer laser required 83 +/1 1 Joules over an exposure period of 118 seconds. Ablation by CO2 and Nd:YAG laser required 153 +/- 13 Joules and 554 +/- 47 Joules delivered over 11 and 6 seconds respectively. In contrast, ablation of the same volume of nerve tissue by RF required 810 +/- 50 Joules over 270 seconds. SEM evaluation revealed that excimer and CO2 laser lesions were narrower in configuration compared to RF and Nd:YAG lesions which showed more lateral spread. The actual depth of penetration per 1 second exposure was similar for Excimer and CO2 (1.5 mm) and RF (1.3 mm), but deeper for Nd:YAG (3 mm).(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Clinical experience with portable cardiopulmonary bypass in cardiac arrest patients.

To evaluate the use of portable cardiopulmonary bypass as a resuscitative tool and its impact on long-term survival of patients in cardiac arrest, we reviewed the results of 32 consecutive patients resuscitated by cardiopulmonary bypass for cardiac arrest or severe hemodynamic compromise at Northwestern Memorial Hospital over a 2-year period. Overall survival was 12.5%. Only 1 (3.4%) of the 29 patients who had cardiac arrest survived and left the hospital. All 3 patients who had severe hemodynamic compromise but not cardiac arrest were long-term survivors. Our study suggests that portable cardiopulmonary support systems used as a resuscitative tool do not prolong the survival of most cardiac arrest patients but may be useful for patients with shock due to mechanical causes and for those with profound hemodynamic compromise due to ischemia or myocardial infarction. Portable heart-lung machines can provide patients with excellent hemodynamic support; however, neurological or cardiac recovery is unlikely once cardiac arrest occurs.

Cardiopulmonary Bypass↗

Prophylaxis of supraventricular tachyarrhythmia after coronary bypass surgery with oral verapamil: a randomized, double-blind trial.

This study investigated the efficacy of oral administration of verapamil, started 24 hours after coronary artery bypass grafting (CABG), in reducing the incidence of postoperative supraventricular tachyarrhythmia (SVT). Two hundred patients were randomly assigned in a double-blind fashion to receive a one-week course of either a placebo or 80 mg of verapamil every 6 hours. Overall, SVT developed in 23 control and 14 verapamil-treated patients, a 39% reduction in incidence (p less than 0.10). Of the patients who received at least four doses and continued to receive the study drug, 17 in the control and 7 in the verapamil group experienced SVT, a 53% decrease in incidence (p less than 0.06). Atrial fibrillation constituted 34 of the 37 SVT episodes and was associated with a slower ventricular response in the group given verapamil (115 +/- 8 versus 156 +/- 4 beats per minute; p less than 0.001). No evidence was found linking postoperative SVT with the withdrawal of beta-blocking drugs. Adverse effects required that 20 patients in the verapamil and 6 in the placebo group be removed from the study. Hypotension or pulmonary edema or both developed in 13 of the patients receiving verapamil, but in only 1 of the control patients (p less than 0.001). We conclude that although verapamil has potential merit for the prophylaxis of SVT after CABG, its use in this setting is associated with a high incidence of unacceptable hemodynamic side effects.

Administration, Oral↗

Image improvement and design optimization of the time-of-flight PET.

Positron emission tomography (PET) with the added time-of-flight information has been shown to provide a better reconstructed image over conventional positron tomography. This improvement depends on the size of the object being imaged, the intrinsic resolution of the detector, and the time-of-flight resolution. Moreover, the signal-to-noise ratio of a PET image is related not only to the total number of counts in the image but also the event-locating uncertainties, the reconstruction filter function, and the recovered resolution in the image. This study provides a physical explanation for, and description of, the improvement in signal-to-noise ratio of a reconstructed image as a function of the crucial design parameters: time-of-flight timing resolution, intrinsic detector resolution, object size, and reconstructed image resolution.

Electricity↗

Mesenteric tumefactions.

Mesenteric tumefactions comprise a group of non-neoplastic conditions that present as an intra-abdominal mass. Symptoms vary from none to obstruction of the gastrointestinal tract. Histologic examination reveals dystrophy, fibrosis, or inflammation of the mesenteric fat. Despite a large number of descriptive terms currently in use, this study suggests that all these lesions are part of a single clinical and histologic continuum.

Adipose Tissue↗