PubMed Health⌕ Search

Biomedical subjects

R Helm

Publications and source records attributed to R Helm.

At least 37 records · Page 2Linked to original sources

Long-term results of total ankle replacement.

The results are reported of 19 total ankle replacements in 18 patients with rheumatoid or other inflammatory arthritis. After a mean follow-up period of 54.4 months (minimum, 24 months), three arthroplasties had failed, all because of loosening. Although all of the remaining patients were improved in terms of pain and function, there was radiographic evidence of loosening in a further eight patients. Indications for the operation are discussed.

Adult↗

Sensitivity and specificity of Czechoslovak ELISA HBsAg Sevac tests: comparison with other third-generation tests and counter-immunoelectrophoresis.

Two variants of sandwich-type ELISA (Enzyme Linked Immunosorbent Assay) kits for HBsAg detection (Sevatest ELISA HBsAg Macro I and Sevatest ELISA HBsAg Micro I) in human sera and plasmas were developed. As the solid phase, the ELISA Macro kit and ELISA Micro kit make use of polystyrene microtubes, and polystyrene microtitration plates, respectively, of Czechoslovak production (Koh-i-noor, Dalecín). Capture anti HBs antibody for adsorption to solid phase and rabbit anti HBs antibody for labelling with horse-radish peroxidase were prepared for both tests. The sensitivity of both ELISA kits for HBsAg, equal to approx. 2 ng/ml, was determined by titrating six selected HBsAg-positive sera and the WHO Agk 76 panel of HBsAg-positive sera and the results were compared with those obtained by ELISA, RIA (Radioimmunoassay) and RPHA (Reverse passive hemagglutination) kits of different producers and by counter-immunoelectrophoresis (CIEP). The sensitivity of the new ELISA kits was comparable to that of other producers' ELISA kits, higher than that of RPHA kits and only a little lower than that of RIA kits. A set of sera of patients hospitalised with different diagnoses was tested for HBsAg. The detection rate by ELISA Macro kit 2.8 and 1.5 times higher than by CIEP and RPHA (Raphadex B), respectively, and 1.1 time lower than by RIA (Austria II).

Counterimmunoelectrophoresis↗

Unusual electron microscopy findings in liver biopsies from patients with viral hepatitis B.

Electron microscopy of 57 needle biopsies from livers of 55 patients with chronic hepatitis, mostly of type B, revealed, in addition to typical hepatitis B virus nucleocapsids in 34 cases, also atypical intranuclear inclusions in 9 biopsies. These inclusions consisted of electron-dense particles similar in size to hepatitis B virus nucleocapsids. The possibility of an involvement of a hepatitis non-A non-B virus is discussed.

Adult↗