PubMed HealthSearch

Biomedical subjects

R Henkin

Publications and source records attributed to R Henkin.

At least 19 recordsLinked to original sources

The clinical significance of exercise-induced bundle branch block.

Exercise-induced bundle branch block is an uncommon electrocardiographic entity said to be associated with coronary heart disease. Thirty-seven patients were studied to determine if exercise hemodynamics and stress/rest thallium scans could identify those patients with coronary heart disease. Eighteen patients of the study group also had coronary angiography. Group I (n = 17) with normal thallium scans and group II (n = 20) with abnormal thallium scans had significantly different maximal heart rate, maximal blood pressure, and double product in exercise as well as duration of exercise. Clinical evaluation of the patient study group permitted a division of the patients into two subgroups: group A, atypical chest pain or abnormal exercise electrocardiogram (n = 12), and group B, definite or probable angina (n = 25). Group B patients had significantly more abnormal thallium scans (17/25) than group A patients (3/12) (p less than 0.04). When compared to coronary angiography, stress/rest thallium scans had a predictive accuracy of 85% for coronary heart disease. While exercise-induced ST-segment depression and R wave amplitude increases are not specific in exercise-induced bundle branch block, exercise hemodynamics and stress/rest thallium scans can help diagnose patients with coronary heart disease. These test findings added to a clinical evaluation permit a more accurate stratification of the patients and indicate which patients need further study.

Bundle-Branch Block

Spectral turbulence analysis of the signal-averaged electrocardiogram and its predictive accuracy for inducible sustained monomorphic ventricular tachycardia.

This study was designed to assess the accuracy of a new noninvasive frequency analysis method for predicting patients with inducible sustained monomorphic ventricular tachycardia (VT) at electrophysiologic study and hence the risk of spontaneous ventricular tachyarrhythmias. Signal-averaged electrocardiograms from 3 orthogonal bipolar surface leads were evaluated using a microcomputer-based frequency analysis system that performs analysis of conventional time-domain late potentials as well as incorporating a new technique for spectral analysis of relatively short, overlapping signal segments spanning the whole QRS complex. The spectral analysis technique measured abnormalities anywhere in the entire QRS complex and did so without dependence on any arbitrarily defined frequency, duration or amplitude cutoffs. The hallmark of arrhythmogenic abnormality was hypothesized to be frequent and abrupt changes in the frequency signature of the QRS wave front velocity as it propagates throughout the ventricle around areas of abnormal conduction, resulting in a high degree of spectral turbulence. One-hundred forty-two subjects were studied, including 71 totally normal control subjects ("true negatives"), 33 with both late potentials by time-domain analysis and inducible sustained monomorphic VT ("true positives"), 28 with late potentials but no evidence of spontaneous or inducible sustained monomorphic VT ("false positives") and 10 with inducible sustained monomorphic VT but absence of time-domain late potentials ("false negatives"). The frequency analysis technique correctly classified 100% of the true negatives, 97% of the true positives, 86% of the late potentials false positives and 60% of the late potentials false negatives. The total predictive accuracy of frequency analysis for all groups was 94%, compared with 73% for time-domain late potential analysis. The results suggest that a high degree of spectral turbulence of the overall QRS signal during sinus rhythm may provide a more accurate marker for the anatomic-electrophysiologic substrate of reentrant tachyarrhythmias than detection of late potentials in the terminal QRS region by either time- or frequency-domain analysis. Spectral turbulence analysis is applicable to patients irrespective of the QRS duration and the presence or absence of bundle branch block.

Electrocardiography

Study of the influence of left bundle branch block on the signal-averaged electrocardiogram: a qualitative and quantitative analysis.

UNLABELLED: To study the influence of left bundle branch block (LBBB) on the signal-averaged electrocardiogram (SAECG), quantitative and qualitative analyses of SAECG parameters were undertaken in 48 patients with electrocardiographic evidence of intrinsic LBBB and in 39 patients with a "normal" surface QRS duration (less than 120 msec) who underwent right ventricular pacing-induced LBBB. We assumed pacing of the right ventricular apex to be a suitable model of this conduction defect. Sustained monomorphic ventricular tachycardia (SMVT) was inducible in 16 of 48 patients with intrinsic LBBB and in 23 of 39 patients with pacing-induced LBBB. Utilizing a filter setting of 25 to 250 Hz, late potentials were defined as a total filtered QRS duration greater than or equal to 120 msec, a root mean square voltage in the terminal 40 msec (RMS 40) of less than or equal to 25 microV, and the duration of signals less than 40 microV (LAS 40) of greater than or equal to 38 msec. Only RMS 40 and LAS 40 criteria were used in patients with LBBB. Prolongation of LAS 40 and fragmentation of signals in the terminal portion of the filtered QRS were characteristic of all patients with LBBB aberration. Of those patients with intrinsic LBBB, the mean total filtered QRS duration, RMS 40, and LAS 40 for inducible and noninducible patients were significantly different (170 +/- 28, 16 +/- 10, 55 +/- 24, and 153 +/- 18 msec, 25 +/- 10 microV, 33 +/- 16.9 msec; p = 0.04, 0.009, and 0.007, respectively). Noninducible patients with a normal QRS duration demonstrated a 60% decrement in the mean RMS 40 value during pacing-induced LBBB. These changes resulted in a 59% false positive incidence of late potentials during pacing-induced LBBB. This correlated with a similarly low mean RMS 40 value in patients with intrinsic LBBB and no inducible SMVT, hence giving rise to a false positive incidence of late potentials of 63%. Since "standard" RMS 40 and LAS 40 criteria resulted in low specificity and positive predictive value, new parameters were selected and analyzed. The combination of RMS 40 less than or equal to 17 microV plus LAS 40 greater than or equal to 55 msec yielded the best overall statistical result, with a sensitivity, specificity, and total predictive accuracy of 69%, 81%, and 77%, respectively. IN CONCLUSION: (1) A reduction of RMS 40, prolongation of LAS 40, and fragmentation of signals in the terminal portion of the filtered QRS are characteristics of LBBB.(ABSTRACT TRUNCATED AT 400 WORDS)

Adult

Comparison of myocardial imaging with iodine-123-iodophenyl-9-methyl pentadecanoic acid and thallium-201-chloride for assessment of patients with exercise-induced myocardial ischemia.

Iodine-123-iodophenyl-9-methyl-pentadecanoic acid [( 123I]MPDA) and thallium-201 (201Tl) were sequentially injected in 11 patients during exercise-induced myocardial ischemia. Simultaneous dual-energy planar images were obtained at 5 min, 3 and 5 hr. All studies were concordantly either positive (8/11) or negative (3/11) by both radionuclides. Exact agreement for segmental uptake was 93%, 94% and 94% for 5-min, 3- and 5-hr images, respectively. Exact agreement for defect reversibility by 3 and 5 hr were 95% and 92%. The initial defect contrasts and myocardial-to-lung ratios were similar by both agents but myocardial-to-liver ratio was lower by [123I]MPDA at 5 min, which became similar to 201Tl at 5 hr. Normal percent myocardial clearances of both agents were comparable and significantly higher than those in defect zones. Thus [123I]MPDA is suitable for myocardial imaging and correlates closely with 201Tl for initial postexercise myocardial uptake and defect reversibility. Defect reversibility appears to result from differential myocardial clearance from normal and ischemic regions.

Aged

Effects of glyburide on ischemia-induced changes in extracellular potassium and local myocardial activation: a potential new approach to the management of ischemia-induced malignant ventricular arrhythmias.

The increase in extracellular potassium [K+]o levels during the early phase of myocardial ischemia may result in part from activation of adenosine triphosphate-sensitive K+ channels. Glyburide, a second-generation hypoglycemic sulfonylurea, is a potent blocker of these channels. We studied the effects of glyburide on [K+]o and on intramyocardial conduction delay during a 10-minute occlusion of the left anterior descending artery in the dog. K(+)-sensitive electrodes and bipolar plunge electrodes were introduced to record, respectively, [K+]o and local electrograms from close sites in midmyocardial regions in normal, border, and ischemic zones. Recordings were obtained before (control ischemia [CI]) and 20 minutes after intravenous administration of 0.15 mg/kg of glyburide (glyburide plus ischemia [G + I]). During G + I the extent of the increase in [K+]o was less compared to that during CI, and the difference was statistically significant during the first 7 minutes of ischemia in the ischemic zone and during the first 4 minutes of ischemia in the border zone. On the other hand, the degree of local intramyocardial conduction delay was significantly reduced during G + I compared to CI during the entire 10 minutes of ischemia in both the ischemic and border zones. In summary, our results have shown that glyburide significantly reduced the rise of [K+]o and intramyocardial delay during the early phase of acute ischemia and could thus attenuate the electrophysiologic consequences of ischemia that underlie the initial phase of malignant tachyarrhythmias. Although the effects of glyburide may result in part from a direct action of the drug on cardiac adenosine triphosphate-sensitive K+ channels, other metabolic antiischemic effects cannot be ruled out.

Animals

Electrophysiological basis of ventricular late potentials.

The presence of late potentials on the body surface recording was correlated with ventricular activation maps of reentrant circuits in the postinfarction canine model of reentrant excitation. Late potentials were found to correlate with delayed myocardial activation. However, during a reentrant rhythm complete diastolic activity on the body surface could not be detected if the mass of electrically active cells was too small and/or if very slow conduction in part of the reentrant circuit generated low amplitude extracellular potentials. Myocardial zones responsible for late potentials during a basic rhythm (e.g., sinus rhythm) may not necessarily be part of the critical zone of slow conduction during reentrant activation. Dynamic changes in late potentials are not amenable to temporal signal averaging techniques but could be detected by a high resolution beat-to-beat recording. A thorough understanding of the electrophysiological limitations of late potentials in the signal-averaged ECG could result in better utilization of the technique in clinical practice as well as in the development of new approaches for the detection of the arrhythmogenic substrate.

Action Potentials

Role of bandpass filters in optimizing the value of the signal-averaged electrocardiogram as a predictor of the results of programmed stimulation.

Normal values for the signal-averaged electrocardiogram (SAECG) at 11 different high-pass filter settings were obtained from 100 normal subjects (group I). The filtered QRS duration and the duration of low amplitude signals less than 40 microV, but not the root mean square voltage of the last 40 ms (RMS40), showed normal distribution. A normal distribution for RMS40 could be obtained by transforming each value to its natural logarithm. The normal values were used in a systematic approach to optimize the accuracy of the SAECG to predict the results of programmed stimulation in 80 patients with spontaneous nonsustained ventricular tachycardia (VT). Fifty-two patients with no inducible VT (group II) and 28 patients with inducible sustained monomorphic VT (group III) were investigated. The 3 SAECG parameters at each high-pass filter in groups II and III were categorized as normal or abnormal and were evaluated singly or in combinations of 2 or 3. There was no combination that provided a sensitivity greater than 82% that could also be obtained by single determinations of low amplitude signals less than 40 microV at 25 to 40 Hz or RMS40 at 40 Hz. On the other hand, there were 267 different combinations that provided a maximal specificity of 98%. The best total predictive accuracy of a single parameter was 85%, provided by RMS40 at 40 or 60 Hz. The total predictive accuracy could be improved to 89% by 1 of 32 different combinations. The top combinations were mostly in triplets and included SAECG parameters recorded at different high-pass filter settings. The only 2 paired combinations with the best total predictive accuracy were RMS40 at 20 or 25 Hz paired with RMS40 at 40 Hz. Frequencies at both ends of the analyzed high-pass filter settings (less than 20 Hz and greater than 60 Hz) were not represented in the top predictive combinations. The SAECG parameters analyzed at 40 Hz were most frequently represented in the top predictive combinations, suggesting that the SAECG may have the best predictive accuracy at this filter setting. In summary, the combination of SAECG parameters analyzed at different filter settings can enhance the accuracy of the technique as a screening test for the results of programmed stimulation in patients with spontaneous nonsustained VT.

Adult

Correlation between the signal-averaged electrocardiogram from Holter tapes and from real-time recordings.

Signal-averaged electrocardiograms obtained from 3-channel Holter recordings were compared, using the same skin electrodes, with signal-averaged real-time recordings in 32 subjects. The numeric late potential parameters and morphologic appearances correlated closely between the 2 methods. The restricted high frequency response of Holter systems appears not to militate against clinically useful late potential analysis from Holter tape. This study suggests that diagnostic accuracy using real-time 25 to 250-Hz criteria is acceptable for clinical use until criteria derived specifically for Holter applications become available. Holter analysis may confer significant benefits resulting from an ability to perform late potential analysis on the same tape used for conventional arrhythmia analysis, and would allow future studies of possible dynamic changes of late potentials in relation to transient ischemia and spontaneous ventricular tachyarrhythmias.

Arrhythmias, Cardiac

Prognostic significance of the signal-averaged ECG depends on the time of recording in the postinfarction period.

Serial recordings of the signal-averaged ECG and the 24-hour ambulatory ECG were obtained from 156 patients with acute myocardial infarction up to 5 days (phase 1), 6 to 30 days (phase 2), and 31 to 60 days (phase 3) after the infarction. Left ventricular ejection fraction by radionuclide ventriculography was also determined in phase 2. The signal-averaged ECG was abnormal during one or more of the three phases in 51 patients (31%). In 35 of these patients (69%) the recording changed category between normal and abnormal with the highest prevalence of abnormal recording occurring during phase 2. Eight patients had ventricular tachycardia/ventricular fibrillation in the first 48 hours after myocardial infarction. The signal-averaged ECG was abnormal in only one of these patients. Twelve patients had late arrhythmic events during the first year of follow-up (four sudden deaths and eight instances of documented ventricular tachycardia or ventricular fibrillation). Nine of the 12 patients had an abnormal signal-averaged ECG in phase 2 and four of these nine had a normal recording in phase 1. Five patients had a transient abnormal signal-averaged ECG in phase 1, whereas six patients had an abnormal recording only in phase 3. None of these 11 patients had an arrhythmic event. Stepwise logistic regression showed that an abnormal signal-averaged ECG in phase 2 has the most significant relation to late arrhythmic events. Both an abnormal signal-averaged ECG and a left ventricular ejection fraction less than 40%, but not complex ventricular arrhythmias, were independent significant risk factors for late arrhythmic events.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged

Quinidine-induced long QTU interval and torsade de pointes: role of bradycardia-dependent early afterdepolarizations.

Right ventricular endocardial monophasic action potential recordings were obtained in a patient with a qunidine-induced long QTU interval and polymorphic ventricular tachycardia of the torsade de pointes type. The recording showed a deflection on phase 3 repolarization characteristic of early afterdepolarization. The early afterdepolarization was synchronous with the U wave in surface electrocardiographic leads and there was a strong correlation between the amplitude of both waves. A strong correlation was also present between the cardiac cycle length and the U wave amplitude with larger amplitudes after longer cycles. Ventricular ectopic beats occurred only after long cycle lengths and seemed to arise close to the peak of the U wave and early afterdepolarization. However, there was no correlation between the amplitude of the U wave or early afterdepolarization and the occurrence of ectopic beats. Rapid ventricular pacing resulted in suppression of the ectopic rhythm associated with suppression of both the U wave and the early afterdepolarization. This case provides the first evidence to suggest that a quinidine-induced long QTU interval and torsade de pointes may be related to bradycardia-dependent early afterdepolarizations, although other factors may be involved in triggering the arrhythmia.

Action Potentials

The signal-averaged electrocardiogram and late potentials. A comparative analysis of commercial devices.

The authors used two separate protocols to compare four commercially available devices for recording of the signal-averaged electrocardiogram and "late potentials" to assess their degree of concordance in identifying abnormalities. In one protocol, studies were performed using each system. In 19% of recordings the results from one system were discordant in at least one numeric parameter. In the second protocol identical averaged data files were used to identify discordancies due solely to differences in analysis algorithms used for QRS offset determination by the various devices. This disclosed 23% discordant findings, mostly in the root mean square amplitude of the terminal 40-msec segment resulting from small differences in the estimate of QRS offset point. To improve concordance between commercial systems, there is an urgent need for adoption of a rigorously standardized algorithm for analysis of baseline noise and QRS offset.

Action Potentials

Value of the signal-averaged electrocardiogram as a predictor of the results of programmed stimulation in nonsustained ventricular tachycardia.

A prospective assessment of several clinical variables, left ventricular function indexes, Holter recording characteristics and signal-averaged electrocardiogram (ECG) for their value in predicting the inducibility of sustained ventricular tachyarrhythmias was carried out in a consecutive series of 105 patients with nonsustained ventricular tachycardia (VT). The patients were divided into 3 groups based on the results of programmed electrical stimulation: group 1, 22 patients with induced sustained monomorphic VT; group 2, 14 patients with induced ventricular fibrillation (VF) and group 3, 69 patients with no induced sustained VT/VF. Left ventricular ejection fraction less than 0.40, history of syncope/presyncope and abnormal signal-averaged ECG were significantly more common in group 1 than in group 3. No significant difference was found between groups 2 and 3. The sensitivity, specificity and predictive accuracy of the signal-averaged ECG for the induction of sustained monomorphic VT were 64, 89 and 84%, respectively. Using stepwise discriminant function analysis, the signal-averaged ECG was found to be the single most accurate screening test to predict the inducibility of sustained VT in patients with nonsustained VT and its value was independent of the etiology of heart disease and the length of spontaneous runs. Because of the very high specificity and negative predictive accuracy, patients with normal signal-averaged ECGs may not require invasive evaluation.

Cardiac Pacing, Artificial

QTU prolongation and polymorphic ventricular tachyarrhythmias due to bradycardia-dependent early afterdepolarizations. Afterdepolarizations and ventricular arrhythmias.

Polymorphic ventricular tachyarrhythmias occurred spontaneously during bradycardia in dogs given the inotropic polypeptide anthopleurin-A (AP-A). The arrhythmia was investigated in in vitro and in vivo experiments. In in vitro experiments, AP-A (50 micrograms/l) produced bradycardia-dependent prolongation of action potential duration that was more pronounced in Purkinje than in muscle fibers. Only Purkinje fibers developed early afterdepolarizations (EAD) and triggered activity. These effects could be abolished by rapid pacing, lidocaine (4 mg/l), or tetrodotoxin (1 mg/l). In vivo experiments were conducted in anesthetized healthy dogs with simultaneous recording of surface ECG, monophasic action potentials from the endocardial and epicardial surface of the left ventricle by contact electrode catheter technique, and transmembrane action potentials from the epicardial surface of the left ventricle with a floating microelectrode technique. AP-A in a dose comparable to that used in vitro (4 micrograms/kg, i.v. bolus) resulted in bradycardia-dependent marked prolongation of both monophasic and transmembrane action potentials. An EAD gradually appeared on both recordings but was more marked in endocardial monophasic action potentials. Eventually, a premature ventricular depolarization arose from or very close to the peak of the EAD. The prolongation of action potentials was associated with similar prolongation of the QTU interval in surface ECG, and in some experiments, the EAD corresponded to a distinct prominent U wave. A ventricular premature depolarization arose from the U or TU complex and initiated polymorphic ventricular tachyarrhythmias that terminated spontaneously or degenerated into ventricular fibrillation. These effects were reversed by rapid pacing or lidocaine (1 mg/kg). The present study provides evidence in support of the hypothesis that AP-A-induced ventricular tachyarrhythmias are due to bradycardia-dependent EAD and triggered activity.

Action Potentials

Resection of parathyroid tumor in the aorticopulmonary window without prior neck exploration.

Of 522 patients with hyperparathyroidism operated on from 1973 to 1987 at our institution, there were seven (1.3%), each with an ectopic, hyperfunctioning mediastinal parathyroid adenoma, who required median sternotomy. In three of these seven patients, the tumor was located in the aorticopulmonary window. A 61-year-old woman with primary hyperparathyroidism had a preoperative thallium-technetium subtraction scan that showed thallium uptake at the base of the heart without any uptake in the neck. After further workup and without prior neck exploration, a parathyroid adenoma was found in the aorticopulmonary window through a median sternotomy. Six months later, serum calcium, phosphorus, and parathyroid hormone values remain normal. Two other cases of parathyroid adenoma in the aorticopulmonary window are presented. Of these two patients, the thallium scan was a key element in the immediate mediastinal exploration of one, who was transferred from another hospital comatose and intubated, in acute hypercalcemic crisis. Since mediastinal parathyroid tumors that necessitate median sternotomy occur in less than 2% of patients with primary hyperparathyroidism, we do not advocate routine preoperative localization studies before an initial cervical operation; localization, however, may be justified in selected cases, such as in critically ill patients or in instances of acute hyperparathyroidism, when the first operation needs to be curative.

Adenoma

Effects of analyzed signal duration and phase on the results of fast fourier transform analysis of the surface electrocardiogram in subjects with and without late potentials.

A microcomputer-based system capable of performing time- and frequency-domain analysis on the same set of acquired and signal-averaged raw data was used to correlate late potentials detected in the time domain with the results of frequency-domain analysis. Ten patients with spontaneous or inducible sustained ventricular tachycardia (VT) known to have abnormal late potentials in the time-domain signal-averaged electrocardiogram and 10 normal subjects without late potentials were studied. Fast Fourier transform analysis was performed on a segment that comprised the last 40 ms of the QRS and the ST segment up to the onset of the T wave as identified visually. The high-frequency signal content, expressed as the area ratio or the peak magnitude, was found to be markedly dependent on the length of the analyzed QRS-ST segment. A change of as little as 3 ms in the duration of the estimated QRS-ST segment changed the results of the frequency analysis across proposed boundaries of normalcy in normal subjects and in patients with VT. This resulted in both false-negative and false-positive conclusions. Similar results were obtained when the effects of varying analyzed signal length or phase were studied using a pure synthesized sine wave signal. For frequency analysis to be clinically useful and reproducible, standards of normalcy must be established for a signal region of fixed duration or the technique must be modified so as to be insensitive to duration of signal sample.

Adult

Routine use of the thallium-technetium scan prior to parathyroidectomy.

The merit of the preoperative localization of parathyroid tumors with thallium-technetium subtraction imaging is a subject of current debate in the treatment of primary hyperparathyroidism. Eighty patients with hyperparathyroidism underwent preoperative subtraction scintigraphy with 201Tl Cl and 99mTcO4; scan results were correlated with the operative identification and histopathology of the resected parathyroid tissue. The true-positive, false-positive and false-negative rates of these scans were compared between patients with tumors in normal and ectopic anatomic locations and between patients undergoing an initial and reoperative neck exploration. The scan was clearly valuable in patients with one or more prior neck explorations. True-positive scans were obtained in seven (77%) of nine such patients. The scan was also valuable in patients who had ectopic tumors (six mediastinal, seven intrathyroid, and two in the carotid sheath). Twelve (80%) of these 15 ectopic tumors were correctly localized either prior to their first operation or before subsequent explorations. In contrast, only 33 (50%) of 65 patients had a true-positive scan prior to their first operation and when the tumor was not in an ectopic location. In summary, in this series, the thallium-technetium scan was correct in only 50 per cent of patients undergoing an initial operation. However, it was positive in 77 per cent of patients who had at least one prior neck exploration and in 80 per cent of patients with an ectopic parathyroid tumor. These results support the selective use of this valuable imaging and localization tool.

Adenoma

Radiologic diagnosis of an intra-abdominal abscess. Do multiple tests help?

A review was made of the charts of 94 patients who underwent ultrasonography (US), computed tomography (CT), and gallium citrate Ga 67 (Gall) scan to rule out intra-abdominal abscesses. Of all the clinical and laboratory data, only the presence of pain and tenderness differentiated patients with and without abscesses. A review of radiologic data showed that CT was superior to US, and that US was superior to Gall scan with regard to sensitivity, specificity, accuracy, and positive and negative predictive values. When multiple radiologic tests were performed, results agreed in 72% of cases; therefore, the additional tests were essentially redundant. When radiologic test results disagreed, accuracy rates were CT, 0.86; US, 0.00; and Gall scan, 0.44. These findings suggest that, except to rule out pelvic abscesses in the presence of pelvic inflammatory disease, CT is usually the only special radiologic test that should be performed to localize a suspected intra-abdominal abscess.

Abdomen