PubMed Health⌕ Search

Biomedical subjects

R Hiebl

Publications and source records attributed to R Hiebl.

4 recordsLinked to original sources

Politano-leadbetter ureteroneocystostomy. A 30-year experience.

PURPOSE: We evaluated the results and complications of children with reflux treated with the Politano-Leadbetter ureteroneocystostomy. In particular, we evaluated pre- and postoperative renal parenchymal scarring and the late development of hypertension. MATERIALS AND METHODS: From 1965 through 1996, 666 children (814 renal units) were reimplanted by nine urologists. The average postoperative evaluation was 10.3 years, and 68.8% of all patiens were evaluable 10 years after surgery. RESULTS: Postoperative complications occurred in 7.8% and consisted of small bowel serosal injury (0.3%), vesicocutaneous fistula (0.4%) and retrovesical hematoma (0.3%). Persistent reflux was the most common postoperative complication (5.6%) and was found to occur in higher grades of vesicorenal reflux. Ureteral stricture and hydronephrosis were seen in 1.2% of children, and was corrected with a secondary reimplantation. Late stricture occurred in all but 1 patient (0.2%). Renal parenchymal scarring was found in 21.2% of patients preoperatively, and this increased over time postoperatively to 27.7%. In 8.7% of these patients, hypertension developed between the 6th and 17th postoperative year. In 6.1%, nephrectomy was carried out, which normalized blood pressures in 87. 9% of these 30 patients. CONCLUSIONS: The Politano-Leadbetter ureteroneocystostomy was successful in 93.6% of all 814 renal units surgically treated. The operation is safe, but can be associated with late development of hypertension despite correction of the reflux.

Adolescent↗

Prepubic urethrectomy with urethral stripping.

PURPOSE: Prepubic urethrectomy is a simple, safe alternative to perineal urethrectomy. The lithotomy position can be avoided and, thus, operative time and risk of deep venous thrombosis are decreased. We developed a simple modification because of difficulty in dissecting the bulbous urethra. MATERIALS AND METHODS: From 1996 through 1998 prepubic urethrectomy was performed using a modified procedure in 21 patients with invasive bladder carcinoma undergoing radical cystectomy and supravesical diversion. After periurethral mobilization the urethra was cannulated with an 18F catheter, sutured distal and stripped free. RESULTS: Operative time decreased to 20 to 30 minutes with no significant postoperative complications. CONCLUSIONS: Our modification of prepubic urethrectomy is safe, fast and easy.

Humans↗

Quantitative determination of pentaerythrityl tetranitrate and its metabolites in human plasma by gas chromatography/mass spectrometry.

Up to now, there has been no data available on the pharmacokinetics of pentaerythrityl tetranitrate (PETN, CAS 78-11-5) and its metabolites, pentaerythrityl-trinitrate (PE-tri-N), pentaerythrityl-dinitrate (PE-di-N), pentaerythrityl-mononitrate (PE-mono-N) in human plasma. Therefore, in order to determine PETN and its metabolites in plasma sensitive and highly selective GC/MS methods had to be developed and validated. PETN and its metabolite PE-tri-N were validated in the concentration range 50 pg/ml to 10 ng/ml. Isosorbide dinitrate (ISDN) was used as the internal standard and the analytes were extracted with dichloromethane from the plasma. The mass spectrometric tests were carried out using chemical ionization in the negative mode (NlCl) with the application of ammonia as a reagent gas. The nitrate ion m/z 62 was determined in the analytes and internal standard. The accuracy of the mean of the quality control samples during the three days (between days) was between 100 and 110% (PETN), as well as 90 and 106% (PE-tri-N). After an oral application of 100 mg PETN in a pilot study, unchanged PETN and PE-tri-N was measured in plasma. Both metabolites PE-di-N and PE-mono-N were validated at the concentration range of 0.25 ng/ml to 25 ng/ml plasma. After extraction, these analytes were derivatized with BSTFA (N,O-bis[trimethylsilyl]trifluoro-acetamide). The applied internal standard was isosorbide-5-mononitrate (IS-5-MN). The mass spectrometric tests were carried out in the same manner as for PETN and PE-tri-N with chemical ionization in the NlCl mode. The detected masses were m/z 324 for PE-di-N, m/z 351 for PE-mono-N and m/z 217 for IS-5-MN. The accuracy of the mean of the quality control samples during 5 days were between 104 and 107% (PE-di-N) and 102 and 106% (PE-mono-N). The maximum concentration of these analytes in the subject samples were on the average all over 5 ng/ml plasma after the oral administration of 100 mg PETN.

Calibration↗