PubMed Health⌕ Search

Biomedical subjects

R I Pettigrew

Publications and source records attributed to R I Pettigrew.

At least 19 recordsLinked to original sources

Magnetic resonance phase-shift velocity mapping in pediatric patients with pulmonary venous obstruction.

OBJECTIVES: This study evaluated the accuracy, advantages and clinical efficacy of magnetic resonance (MR) phase-shift velocity mapping, in delineating the site and the hemodynamic severity of pulmonary venous (PV) obstruction in patients with congenital heart disease (CHD). BACKGROUND: Magnetic resonance phase-shift velocity mapping of normal pulmonary veins and of obstructed PV pathways have been previously reported in a mainly adult population. METHODS: The study population (33 pts) underwent MR phase-shift velocity mapping of their PV pathways. These results were compared with cardiac catheterization and Doppler echocardiography data. RESULTS: The study population (0.4 to 19.5 years) consisted of a study group (PV pathway obstruction, n = 7) and a control group (no PV obstruction, n = 26). No patients had any left-to-right shunt lesions. The MR imaging displayed precise anatomical detail of the pulmonary veins. Phase velocities in the control group ranged from 20 to 71 cm/s, whereas velocities in the study group ranged from 100 to 250 cm/s (p = 0.002). The MR phase velocities (154 +/- 0.53 cm/s) compared favorably with Doppler echocardiography (147 +/- 0.54 cm/s), (r = 0.76; p = 0.05). The MR velocity mapping was 100% specific and 100% sensitive in detecting PV obstruction, although the absolute gradient measurements among MR phase mapping, echocardiographic Doppler and catheterization did not show statistically significant correlation. CONCLUSIONS: In the absence of any associated left-to-right shunt lesions, PV velocities of 100 cm/s and greater indicated significant obstruction. The MR phase-shift velocity mapping, together with MR spin echocardiography and MR angiography, provides comprehensive anatomic and physiologic data that may obviate the need for further invasive studies.

Adolescent↗

Evaluation of the precision of magnetic resonance phase velocity mapping for blood flow measurements.

Evaluating the in vivo accuracy of magnetic resonance phase velocity mapping (PVM) is not straightforward because of the absence of a validated clinical flow quantification technique. The aim of this study was to evaluate PVM by investigating its precision, both in vitro and in vivo, in a 1.5 Tesla scanner. In the former case, steady and pulsatile flow experiments were conducted using an aortic model under a variety of flow conditions (steady: 0.1-5.5 L/min; pulsatile: 10-75 mL/cycle). In the latter case, PVM measurements were taken in the ascending aorta of ten subjects, seven of which had aortic regurgitation. Each velocity measurement was taken twice, with the slice perpendicular to the long axis of the aorta. Comparison between the measured and true flow rates and volumes confirmed the high accuracy of PVM in measuring flow in vitro (p > 0.85). The in vitro precision of PVM was found to be very high(steady: y = 1.00x + 0.02, r = 0.999; pulsatile: y = 0.98x + 0.72, r = 0.997; x: measurement #1, y: measurement #2) and this was confirmed by Bland-Altman analysis. Of great clinical significance was the high level of the in vivo precision (y = 1.01x - 0.04, r = 0.993), confirmed statistically (p = 1.00). In conclusion, PVM provides repeatable blood flow measurements. The high in vitro accuracy and precision, combined with the high in vivo precision, are key factors for the establishment of PVM as the "gold-standard" to quantify blood flow.

Aorta, Thoracic↗

Quantitative prediction of improvement in cardiac function after revascularization with MR imaging and modeling: initial results.

PURPOSE: To evaluate a model that can be used quantitatively to predict changes in postrevascularization left ventricular function based on classification of myocardial tissue as hibernating, scarred, or normal with cine magnetic resonance (MR) imaging. MATERIALS AND METHODS: Eleven patients with chronic left ventricular dysfunction were studied before and after revascularization with cine MR imaging. Regional myocardial contractility and wall thickness were used in the model to predict postrevascularization ejection fraction (EF). The actual EF from the postrevascularization MR images was compared with the EF from the prerevascularization images predicted with the model by using regression analysis and Bland-Altman analysis. RESULTS: Correlation between the actual EF after revascularization and the EF predicted by using the model yielded an R value of 0.98, with a standard error of 1.3 EF percentage points. Predicting changes in function in a myocardial segment was less successful because only 55% of segments classified as hibernating actually improved resting function after revascularization. In nonimproved segments, 78% were either adjacent to infarcted segments or had nontransmural wall thinning. CONCLUSION: A simple mathematical model combined with functional information provided by MR imaging was used to predict improvements in global EF resulting from revascularization.

Aged↗

Intracoronary basic fibroblast growth factor (FGF-2) in patients with severe ischemic heart disease: results of a phase I open-label dose escalation study.

OBJECTIVES: Evaluate the safety, tolerability and preliminary efficacy of intracoronary (IC) basic fibroblast growth factor (bFGF, FGF-2). BACKGROUND: FGF-2 is a heparin-binding growth factor capable of inducing functionally significant angiogenesis in animal models of myocardial ischemia. METHODS: Phase I, open-label dose-escalation study of FGF-2 administered as a single 20-min infusion in patients with ischemic heart disease not amenable to treatment with CABG or PTCA. RESULTS: Fifty-two patients enrolled in this study received IC FGF-2 (0.33 to 48 microg/kg). Hypotension was dose-dependent and dose-limiting, with 36 microg/kg being the maximally tolerated dose. Four patients died and four patients had non-Q-wave myocardial infarctions. Laboratory parameters and retinal examinations showed mild and mainly transient changes during the 6-month follow-up. There was an improvement in quality of life as assessed by Seattle Angina Questionnaire and improvement in exercise tolerance as assessed by treadmill exercise testing (510+/-24 s at baseline, 561+/-26 s at day 29 [p = 0.023], 609+/-26 s at day 57 (p < 0.001), and 633+/-24 s at day 180 (p < 0.001), overall p < 0.001). Magnetic resonance (MR) imaging showed increased regional wall thickening (baseline: 34+/-1.7%, day 29: 38.7+/-1.9% [p = 0.006], day 57: 41.4+/-1.9% [p < 0.001], and day 180: 42.0+/-2.3% [p < 0.001], overall p = 0.001) and a reduction in the extent of the ischemic area at all time points compared with baseline. CONCLUSIONS: Intracoronary administration of rFGF-2 appears safe and is well tolerated over a 100-fold dose range (0.33 to 0.36 microk/kg). Preliminary evidence of efficacy is tempered by the open-label uncontrolled design of the study.

Aged↗

Prognostic value of thallium-201 single-photon emission computed tomography for patients with multivessel coronary artery disease after revascularization (the Emory Angioplasty versus Surgery Trial [EAST]).

The aim of this study was to investigate the relation between reversible thallium single-photon emission computed tomography (SPECT) myocardial perfusion defects at 1-year after revascularization and quantitative indexes in Emory Angioplasty versus Surgery Trial (EAST) and outcomes 3 years after revascularization in 336 patients. EAST was a randomized controlled trial assessing cardiac outcomes for angioplasty versus bypass surgery for patients with multivessel coronary artery disease. During this prospective trial, a substudy included the evaluation of the prognostic value of reversible defects on quantitative thallium SPECT. At 1-year after revascularization, 336 patients underwent SPECT thallium-201 stress myocardial perfusion and 3-hour delayed imaging. Subsequent events, percutaneous transluminal coronary angioplasty, coronary artery bypass graft surgery, myocardial infarction, and death, were recorded at 3 years. A stress-induced reversible thallium-201 defect was defined using a quantitative index of a reversibility score >30% and severity score >500. Reversible defects were observed more frequently in the percutaneous transluminal coronary angioplasty than in the coronary artery bypass graft surgery treatment groups (46% vs 27%, p <0.001). A total of 123 patients had stress-induced, reversible thallium defects and more events than patients with other perfusion results (freedom from all events was 81.3% vs 94% [p <0.001], and freedom from myocardial infarction and death 88.3% vs 95.5% [p = 0.031]). Quantitative thallium SPECT at 1 year after revascularization risk stratifies patients as to their likelihood of major cardiac outcomes.

Aged↗

Use of navigator-echo-gated MRI to diagnose a coronary shunt involving an anomalous origin of the right coronary artery from the pulmonary artery.

Origin of the right coronary artery from the main pulmonary artery is an anomaly that can cause formation of a left-to-right coronary shunt, leading to myocardial ischemia and early onset of congestive heart failure. We describe a case in which magnetic resonance imaging was able to show the anomalous origin of the right coronary artery, and magnetic resonance phase velocity mapping was able to demonstrate the presence of a left-to-right shunt through the coronary artery by showing retrograde flow in the right coronary artery.

Adult↗

MRI techniques for cardiovascular imaging.

Over the last several years, cardiovascular MRI has benefited from a number of technical advances which have improved routine clinical imaging techniques. As a result, MRI is now well positioned to realize its longstanding promise of becoming the comprehensive cardiac imaging test of choice in many clinical settings. This may be achieved using a combination of basic advanced techniques. In this overview, the basic cardiac MRI techniques which are clinically useful are reviewed, and the recent technical advances which are clinically promising are described. These advances include routine black blood and cine bright blood techniques that are high speed (<10s per black blood image or cine slice), multislice whole heart perfusion imaging methods, and recently emerging real-time imaging methodologies. J Magn. Reson. Imaging 1999;10:590-601.

Cardiovascular System↗

Left ventricular function and perfusion from gated SPECT perfusion images: an integrated method.

UNLABELLED: A new technique for computing left ventricular function, including left ventricular volumes, mass and ejection fraction, has been developed. This method is a logical extension of the results of a standard perfusion quantification technique; thus, it allows integration of perfusion and functional information. METHODS: Anatomically based models of the endocardial and epicardial surfaces are generated using the myocardial samples for which perfusion values are quantified, for all frames in the cardiac cycle. With these surface points, left ventricular chamber volume and myocardial volume can be computed. A computer simulation was used to determine the sensitivity of the approach to the assumptions of the model. Validation of volume, mass and ejection fraction was performed with correlative MR studies, and ejection fraction and left ventricular volumes were further investigated using correlative first-pass studies. RESULTS: Automated processing was successful in 96% of the cases analyzed. End diastolic volume, end systolic volume, left ventricular mass and left ventricular ejection fraction correlated with MRI with r = 0.97, 0.99, 0.87, and 0.85, respectively. Ejection fraction from tomography correlated with first-pass values with r = 0.82, and end diastolic and end systolic volumes from tomography correlated with first-pass values with r = 0.85 and r = 0.91, respectively. CONCLUSION: The new integrated approach is accurate and robust for computing both perfusion and function from perfusion tomograms.

Computer Simulation↗

Magnetic resonance coronary angiography using navigator echo gated real-time slice following.

Navigator echo gating allows for the elimination of breath-holding in MR imaging by providing a real-time monitor of respiratory position to gate image acquisition. In this study we examined the advantages and utility of real-time, navigator echo gated slice following technique in 2D magnetic resonance coronary angiography of patients with coronary artery disease. Thirteen patients with coronary artery disease were examined. MR images of the right coronary artery (RCA) were obtained parallel to the atrioventricular groove to image long sections of the RCA in a small number of slices. In-plane resolution was 0.7 x 0.9 mm and 2-6 signals were averaged to support this high spatial resolution. Targeted maximum intensity projection (MIP) images were generated from the slices to present the RCA in a single image. All patients had x-ray angiograms available for comparison with the MR images. Using the navigator echo gated real-time slice following technique, MRI successfully obtained images in 11 of 13 cases. The technique failed in two patients with irregular breathing patterns. The average length of the RCA seen in the 11 successful MR exams was 61 mm and the average length seen in the x-ray angiograms was 80 mm. Eight patients were determined to be without disease in the RCA by x-ray angiography, and all eight were correctly identified as normal on the MRI exam. In the three patients who had a successful MRI exam and were determined to have disease in the RCA by x-ray angiography, MRI identified the lesion in two cases. In the third case MRI indicated a discrete lesion and x-ray angiography indicated diffuse disease without a focal lesion. Navigator echo gating improves patient tolerance, provides aligned sections of coronaries over multiple slices, and allows for improved resolution through signal averaging. This preliminary patient study suggests that navigator echo gated magnetic resonance coronary angiography may play a role in evaluating coronary artery disease.

Coronary Angiography↗

Quantification of the aortic regurgitant volume with magnetic resonance phase velocity mapping: a clinical investigation of the importance of imaging slice location.

BACKGROUND AND AIMS OF THE STUDY: Current techniques for assessment of aortic regurgitation (AR) are mainly qualitative. Magnetic resonance phase velocity mapping (PVM) provides accurate measurements of arterial blood blow. In AR, the aortic regurgitant volume (ARV) can be quantified with a single imaging slice measurement in the ascending aorta. The aim was to use PVM to: (i) quantify the regurgitant volume in patients with AR using an in vitro validated technique; and (ii) confirm in vivo our previous in vitro findings of the importance of measurement location. METHODS: Four healthy volunteers and 19 patients with AR, varying from mild to severe, were examined in a 1.5 Tesla MRI scanner. In 13 patients, the slice was placed: (i) between the aortic valve and the coronary ostia; (ii) at the sinotubular junction (SJ); and (iii) 2 cm above the SJ. In six patients, one measurement was taken as close as technically possible to the aortic valve. PVM measurements of the ARV were compared with angiographic/echocardiographic AR grading. RESULTS: No ARV was measured in healthy subjects. In patients, PVM results correlated well with angiographic/echocardiographic data. Repeatability of the PVM results was excellent and interobserver variability very small. The measured ARV decreased as the slice distance from the aortic valve increased, due to aortic compliance, in agreement to previous in vitro results. Close to the valve, acceleration did not affect the accuracy of velocity measurements. CONCLUSIONS: PVM has great potential to measure AR in a purely quantitative manner. Measurement location is important and results suggest that the closer the measurement to the valve the more accurate the ARV quantification.

Aortic Valve Insufficiency↗

Slice location dependence of aortic regurgitation measurements with MR phase velocity mapping.

Although several methods have been used clinically to assess aortic regurgitation (AR), there is no "gold standard" for regurgitant volume measurement. Magnetic resonance phase velocity mapping (PVM) can be used for noninvasive blood flow measurements. To evaluate the accuracy of PVM in quantifying AR with a single imaging slice in the ascending aorta, in vitro experiments were performed by using a compliant aortic model. Attention was focused on determining the slice location that provided the best results. The most accurate measurements were taken between the aortic valve annulus and the coronary ostia where the measured (Y) and actual (X) flow rate had close agreement (Y = 0.954 x + 0.126, r2 = 0.995, standard deviation of error = 0.139 L/min). Beyond the coronary ostia, coronary flow and aortic compliance negatively affected the accuracy of the measurements. In vivo measurements taken on patients with AR showed the same tendency with the in vitro results. In making decisions regarding patient treatment, diagnostic accuracy is very important. The results from this study suggest that higher accuracy is achieved by placing the slice between the aortic valve and the coronary ostia and that this is the region where attention should be focused for further clinical investigation.

Aorta↗

Computational simulation of turbulent signal loss in 2D time-of-flight magnetic resonance angiograms.

Time-of-flight magnetic resonance (MR) angiography is currently limited in the evaluation of arterial stenoses by flow-induced signal loss. This signal loss has been attributed to phase dispersion and to phase misregistration. We have developed a fluid mechanics model of 2D time-of-flight MR angiograms to study the amount of signal loss caused by random turbulence. The simulations were created by stochastic analysis of particle pathlines determined by computational fluid dynamics for turbulent flow. The images obtained by the model compare well to actual MR images of flow in stenoses. By selectively removing the random turbulent motion in the simulation, it can be seen that random phase dispersion is the dominant mechanism of signal loss. Phase misregistration and mean flow phase dispersion act as secondary effects. The MR simulation model recreates accurately the variation of signal loss over a range of echo times. The model can be used further to explore and design new pulse sequences. For example, the current study showed that high slew rate gradient waveforms can significantly reduce poststenotic signal loss. In conclusion, computational modeling of MR angiography can be a useful approach for the analysis of MRA signal loss and the design of improved pulse sequences.

Blood Flow Velocity↗

Myocardial suppression in vivo by spin locking with composite pulses.

Improved myocardium-blood contrast by myocardial suppression resulting from T1 rho-weighting in contrast-enhanced, gradient-echo, bright-blood cine images, acquired at 1.5T, is shown. In the standard images, blood has twice the intensity of muscle. In similar T1 rho-weighted images, it has 3-4 times the intensity of muscle. A composite spin-lock pulse before each observation pulse provides T1 rho-weighting. A typical pulse was: 90y-135x-360x-135x-90(-y) with element durations: 0.84, 1.26, 8.12, 1.26, and 0.84 ms. The tolerance of this composite pulse to shimmering and frequency errors allows spin locking with comparatively weak RF and therefore low specific absorption rate (SAR). Initial clinical evaluation on patients with poor ventricular function demonstrates both a qualitative and quantitative improvement in delineation of myocardial borders.

Absorption↗

The importance of work-up (verification) bias correction in assessing the accuracy of SPECT thallium-201 testing for the diagnosis of coronary artery disease.

Noninvasive testing is often evaluated by the sensitivity and specificity in comparison with a more invasive, but more definitive "gold" standard. However, work-up or verification bias, which occurs when the results of a noninvasive test impact the decision to perform the gold standard invasive test, increases the "observed" sensitivity and decreases the "observed" specificity of the noninvasive test. Most large clinical studies utilizing a noninvasive technique to diagnose coronary artery disease have biases, particularly work-up bias. To obtain more accurate measurements of sensitivity and specificity, we determined the observed sensitivity and specificity of stress (exercise and dipyridamole) single photon emission computed tomographic (SPECT) thallium testing for the detection of coronary artery disease by angiography, and then applied previously published equations to correct for work-up bias. From a computerized data base, reports of 4354 stress SPECT thallium studies from January 1, 1986 through December 31, 1992 were reviewed. All patients with a known history of myocardial infarction or prior coronary angiography were excluded, leaving 2688 patients. From this total, 471 patients underwent coronary angiography within 90 days following stress SPECT thallium testing. Coronary artery disease was defined as a visually assessed stenosis of a coronary artery or a major branch > 50%. Of the 2688 stress SPECT thallium studies, 1265 were normal and 1423 were abnormal. For the 471 patients who underwent catheterization within 90 days following stress SPECT thallium testing. the "observed" sensitivity and specificity were 98 and 14%, respectively. After correction for work-up bias, the corrected sensitivity and specificity were 82 +/- 6% and 59 +/- 2%, respectively. Most studies utilizing noninvasive technologies for the detection of coronary artery disease include patients with known coronary artery disease and have work-up bias as well. By knowing the thallium results of patients with and without catheterization, we were able to correct for work-up bias. These data provide better estimate of the sensitivity and specificity of stress SPECT thallium testing.

Bias↗

Cine-MRI-aided endomyocardectomy in idiopathic hypereosinophilic syndrome.

The idiopathic hypereosinophilic syndrome is a leukoproliferative disorder marked by a predilection to damage specific organs, including the heart. This report describes a patient with extensive endocardial fibrosis accompanying this syndrome. Right ventricular endomyocardectomy with preservation of the tricuspid valve was performed. The procedure was aided by cine-magnetic resonance imaging for preoperative assessment and follow-up of surgical results.

Adult↗

Improved measurement of pressure gradients in aortic coarctation by magnetic resonance imaging.

OBJECTIVES: This study evaluated whether magnetic resonance imaging (MRI) and magnetic resonance (MR) phase velocity mapping could provide accurate estimates of stenosis severity and pressure gradients in aortic coarctation. BACKGROUND: Clinical management of aortic coarctation requires determination of lesion location and severity and quantification of the pressure gradient across the constricted area. METHODS: Using a series of anatomically accurate models of aortic coarctation, the laboratory portion of this study found that the loss coefficient (K), commonly taken to be 4.0 in the simplified Bernoulli equation delta P = KV2, was a function of stenosis severity. The values of the loss coefficient ranged from 2.8 for a 50% stenosis to 4.9 for a 90% stenosis. Magnetic resonance imaging and MR phase velocity mapping were then used to determine coarctation severity and pressure gradient in 32 patients. RESULTS: Application of the new severity-dependent loss coefficients found that pressure gradients deviated from 1 to 17 mm Hg compared with calculations made with the commonly used value of 4.0. Comparison of MR estimates of pressure gradient with Doppler ultrasound estimates (in 22 of 32 patients) and with catheter pressure measurements (in 6 of 32 patients) supports the conclusion that the severity-based loss coefficient provides improved estimates of pressure gradients. CONCLUSIONS: This study suggests that MRI could be used as a complete diagnostic tool for accurate evaluation of aortic coarctation, by determining stenosis location and severity and by accurately estimating pressure gradients.

Adolescent↗