Electroencephalogram and repetitive transcranial magnetic stimulation.

Scalp recordings of the electroencephalogram (EEG) have been used in association with repetitive transcranial magnetic stimulation (rTMS) investigations as a safety measure in monitoring ongoing EEG activity and as a neurophysiologic tool in examining the specific effects induced by the magnetic stimulus on the EEG or evoked potentials (EPs). Medline review on the use of EEG or EPs with rTMS reveals that this area has been largely unexplored. Limited available studies attest to the potential for studies combining EEG/EPs and rTMS to be useful in further elucidating the normal brain physiology. Herein, we report on our experience with continuous EEG sampling combined with rTMS in patients with major depression (n = 14), schizophrenia (n = 7), and obsessive-compulsive disorder (n = 5). Our data support the practice of using continuous EEG monitoring when the stimulation parameters fall outside established safety guidelines.

Brain Mapping↗

From objective to subjective: pitch representation in the human auditory cortex.

Magnetic brain responses to infrequent changes in the pitch of complex sounds were recorded. The composition of the test sounds required that pitch-deviant stimuli elicited the mismatch response only if perceived pitch was represented in auditory sensory memory. Results revealed that subjective features, such as pitch, are formed from objective stimulus parameters (i.e. the spectral contents of a sound) before storing acoustic information in memory. The origin of the magnetic response to pitch change showed that pitch deviation was detected in the auditory cortex. Pitch memory might also be located in the auditory cortex, as previous evidence suggests that storage for an auditory feature lies in the vicinity of the neuronal elements activated by deviations in that feature.

Acoustic Stimulation↗

Transformation of multichannel magnetocardiographic signals to standard grid form.

Multichannel magnetocardiographic (MCG) recordings with fixed sensor arrays are not directly comparable with single-channel measurements carried out at standard grid locations. In addition, comparison of data obtained with different types of magnetometers is difficult. We present a method for transforming multichannel measurements to the standard-grid format. The minimum-norm estimate (MNE) of the source current distribution in the body is calculated, and the desired field components in standard grid points are then computed from the MNE. We measured three subjects with both a 24-channel and a single-channel instrument. The signals extrapolated from the multichannel measurements corresponded quite well to the single-channel data registered at the standard grid locations, especially in those grid points that were covered by the 24-channel device. The signal-amplitude-weighted correlations between the extrapolated and directly measured signals were 0.73-0.87. In simulations with ideal measurement geometry but with a realistic amount of random noise in the signals, we obtained a 0.99 correlation. It was also found that the method is relatively tolerant to errors in the location and orientation of the multichannel magnetometer. For example, a simulated 20-mm displacement in the location of the sensor array caused only a 3% decrease in the correlation, and when it was rotated and tilted by 10 degrees C, the correlation decreased by 5%. The basic advantage of our extrapolation method is its physiologic nature: the method is based on the mathematical modeling of the source current distribution, rather than on direct constraints applied to the magnetic field.

Adult↗

Somatosensory evoked cerebral magnetic fields from SI and SII in man.

We have recorded cerebral magnetic fields elicited by electrical stimulation of median and peroneal nerves. Field mapping indicates that the deflections at 30-80 and 150-180 msec are due to activity at SI. Additional activity at 90-125 msec is generated at SII, on the superior bank of the sylvian fissure. At SI, the source locations are in agreement with the known somatotopy. Only contralateral stimuli evoke responses at SI, whereas both ipsi- and contralateral stimuli elicit responses at SII.

Adult↗

A four-channel SQUID magnetometer for brain research.

A 4-channel differential SQUID magnetometer has been built. Its design principles and construction are described. Proper matching of the detection coil to the SQUID input is discussed. Examples of auditory, dental pain and visual evoked response data are presented.

Electroencephalography↗

Magnetocardiographic localization of ventricular pre-excitation in a child with a congenital heart defect.

Magnetocardiographic mapping was performed on a 2-year-old boy who suffered from the Wolff-Parkinson-White syndrome in association with a complex congenital heart defect. The pre-excitation site was determined noninvasively from the measured cardiac magnetic fields. The location was in the same anatomic region as found by intraoperative epicardial mapping. This result shows that magnetocardiography can be helpful for determining an accessory pathway also in patients with grossly abnormal cardiac anatomy.

Child, Preschool↗

[Physical basis of the generation of neuromagnetic fields].

Electrical processes at the neuronal level are considered, which cause the neuromagnetic fields. Those fields presently measured are due to the synchronous activity of about 10(5) neurons. Short magnetic signals can be caused by afferent and efferent strains of action potentials, the longer ones being due to the synaptic activity at the ends of apical dendrites in the fissural cortex.