PubMed Health⌕ Search

Biomedical subjects

R J Barish

Publications and source records attributed to R J Barish.

27 records · Page 2Linked to original sources

Saturation curve in gases of high atomic number at pressures up to 8 atm. Part II: Freon 13-B1, and mixtures of Freon with xenon and krypton.

The saturation curve has been studied in Freon 13-B1 (CF3Br) and in mixtures of Freon with xenon and krypton up to a pressure of 8 atm. The enhanced initial recombination due to the electron affinity of Freon has been evaluated and an empirical formula constructed that describes the fraction of current which escapes initial recombination over a wide range of voltages, pressures, and electrode spacings. After correction for this initial recombination, the general saturation curve for Freon and for mixtures of this gas with krypton and xenon has been derived and, again, convenient empirical formulae established which allow the current collection efficiency to be calculated for any given parameters within the range investigated. These formulae are of practical value in the design of image-forming ionization chambers.

Chlorofluorocarbons, Methane↗

Extended expression for tissue-maximum ratio fitted to the Varian Clinac-4 and Clinac-6 accelerators.

An expression which generates tissue maximum ratio (TMR) data for the Varian Clinac-4 and Clinac-6 accelerators is presented. This semiempirical expression can be programmed easily for radiotherapy computer systems or the new generation of scientific calculators. Our technique leads to good agreement with the published data, as demonstrated by a total average percent deviation of the measured TMR values of -0.115% for the Clinac-4 and -0.002% for the Clinac-6.

Particle Accelerators↗

Development of optical process for accessing three-dimensional patient topology.

A commercial optical system developed by Solid Photography, Inc., has been used to generate precise paraffin--polyethylene tissue compensators. A program with the objective of constructing a medical facility has been undertaken to access patient topology for treatment planning, tissue-compensator fabrication, and patient positioning verification on the treatment table. Currently, patients are taken to a specially equipped studio where a series of microprocessor-controlled reticles are projected on the surface to be analyzed and photographs are taken automatically for computer processing. The topology data then drives a machine tool to sculpt the tissue compensators and may be transmitted via acoustic-coupled terminals to a treatment-planning computer at the Medical Center. The tissue compensators have been found to conform accurately to patient contours. At present, data bases can be generated to accommodate volumes of approximately 70,000 cm3.

Models, Structural↗

Thermal characteristics of a common polystyrene phantom.

We have examined the thermal characteristics of a polystyrene phantom of the SCRAD type. In the case of a calibration phantom which is moved from one location to another, many hours may be required to achieve thermal equilibrium with the new environment. By using a correction term based on the temperature of the phantom, not of the room, it is possible to calibrate a therapy unit without waiting for thermal equilibrium.

Humans↗

Source-surface distance and source-axis distance beam data acquisition.

Radiation beam characteristics are usually obtained by scanning in a water phantom. Central axis depth dose data, beam profiles, and isodose curves are derived from these measurements. Certain treatment planning systems require that beam profiles be scanned isocentrically rather than at a constant source-surface distance. We have looked at profiles taken both ways, with appropriate field-size correction, and find no significant difference between them. This should simplify data acquisition in many cases.

Radiometry↗

Teletherapy beam characteristics: the first second.

The beam characteristics of radiotherapy treatment units are measured and recorded under circumstances in which transient effects are eliminated. Output measurements are done by averaging several readings. Isodose curves are obtained during a period of irradiation which is large compared with that used in patient treatment. When treatments are given, the therapy unit is assumed to deliver radiation beams that match the data acquired during calibration. We have looked at the energy, field uniformity, and output constancy typical of a number of these machines in their initial stages of operation. Although most can provide their "reference" beam characteristics in a short time, there are exceptions. The implications for patient treatment, port filming, and film dosimetry are discussed.

Humans↗

Long-term use of an isotope check source for verification of ion chamber calibration.

A radioactive check source is recommended for operational and constancy checks of dosimetry systems used for the calibration of therapeutic x-ray generators, including linear accelerators. Eight years of data have been analyzed for two ion chambers (and their associated electrometers) irradiated at fixed geometry in such a device. These dosimetry systems have also been calibrated every 2 years at a single Accredited Dosimetry Calibration Laboratory. Our analysis suggests that when a check source is used, and the results are consistent, the interval between formal calibrations can be lengthened.

Humans↗

An improvement in the use of plaster bandage for patient contouring.

The setting time of plaster bandage used for patient contouring can be decreased by adding potassium sulfate to the dip water. A small amount of this inexpensive chemical can have a significant effect. This improvement gives the physicist sufficient control of the process so that contours may be made from plaster as quickly as they are made with stiff wire, but with improved accuracy.

Bandages↗

In-flight radiation: counseling patients about risk.

BACKGROUND: At the high altitudes, which are the domain of commercial airliners, cosmic-ray exposure rates are hundreds of times greater than at ground level. If this radiation originated at a regulated industrial or medical facility, many frequent flyers would receive annual exposures in excess of the present legal limit applicable to members of the public. For pregnant travelers, the fetus is also at risk, with a sensitivity that varies during the course of pregnancy. METHODS: Health risks from in-flight radiation exposure are analyzed specifically to calculate the likelihood of cancer, birth defects, and genetic damage. A literature review was conducted from 1985 to 1998, using the key words "cosmic radiation," "aviation medicine," "radiation risk," and "in-flight radiation." RESULTS AND CONCLUSIONS: The analysis shows that for the passenger who travels only occasionally, the risks are extremely small. For business frequent flyers the risks are still small, but not negligible.

Aerospace Medicine↗