On-line identification method in column liquid chromatography: UV resonance Raman spectroscopy.

Ultraviolet resonance Raman spectroscopy (RRS) is presented as a novel identification tool for conventional-size column liquid chromatography (LC). The on-line coupling was made using a standard Z-shaped flow cell. A continuous-wave frequency-doubled argon ion laser operating at a wavelength of 244 nm was used for excitation. "On-the-fly" resonance Raman spectra of four model compounds, fluorene, phenanthrene, fluoranthene, and pyrene, were recorded after a standard acetonitrile/water reversed-phase LC separation. When applying a large-volume-injection procedure (32 mL), detection limits were at the nanogram per milliliter level. The results indicate that UV-RRS gives detailed spectral information at an appropriate sensitivity level so that coupling with LC becomes feasible.

Journal Article↗

Liquid-core waveguide technology for coupling column liquid chromatography and Raman spectroscopy.

The on-line coupling of liquid chromatography (LC) and Raman spectroscopy (RS) via an entirely plastic liquid-core waveguide (LCW) was optimized in terms of excitation wavelength of the laser, especially in relation to the fluorescence background, and the length of the LCW. Excitation at 632.8 nm (He-Ne laser) was found to be a good compromise between a wavelength long enough to strongly reduce the fluorescence background and, on the other hand, short enough to avoid (re)-absorption of laser light and Raman signals by H2O in LCWs of considerable length. This conclusion is supported by a theoretical discussion on the optimization of LCW lengths as function of the excitation wavelength for H2O and 2H2O. When using the He-Ne laser the optimum length is approximately 50 cm for H2O; this corresponds to a detection cell volume of 19 microl for an LCW of 220 microm I.D., which is fully compatible with conventional-size LC. The influence of an organic modifier, usually necessary for reversed-phase LC, on the free spectral window was evaluated. The potential applicability of LC-LCW-RS was shown for a mixture of adenosine 5'-monophosphate (AMP), guanosine 5'-monophosphate (GMP) and uridine 5'-monophosphate (UMP), utilizing an aqueous eluent without the addition of a modifier. Improved detectability was achieved by using the stopped-flow mode and applying a large-volume-injection procedure (injection volume: 200 microl). Under these conditions, the limit of identification for AMP, GMP and UMP was in the 0.1-0.5-mg/ml range.

Adenosine Monophosphate↗

Surface-enhanced resonance Raman spectroscopy as an identification tool in column liquid chromatography.

The compatibility of ion-pair reversed-phase column liquid chromatography and surface-enhanced resonance Raman spectroscopy (SERRS) for separation and identification of anionic dyes has been investigated, with emphasis on the at-line coupling via a thin-layer chromatography (TLC) plate. SERR spectra using silver sols were recorded both for aqueous solutions and for samples deposited on aluminum oxide and silica TLC plates at 514.5- and 457.9-nm laser excitation. For some dyes, the shorter wavelength was needed to diminish the fluorescence background. For aqueous solutions and for samples deposited on aluminum oxide, clear SERR spectra were obtained upon addition of poly(L-lysine); for the silica plates, the addition of nitric acid was required. Upon drying the plates, the SERRS signals decreased in intensity; simply adding a drop of water could largely restore them. At-line coupling of LC and SERRS was successfully achieved when using silica, but not aluminum oxide, plates. The application of a gradient, a high water content, and the presence of ion-pair reagents needed for the separation did not adversely affect the deposition and the recording of SERR spectra. The identification limits were 10-20 ng of deposited material, depending on the dye selected, which corresponded to injected concentrations of 5-10 microg mL(-1).