Evaluation of AVL988/4 analyzer for measurement of ionized magnesium and ionized calcium.

Ionized magnesium (Mg++) and ionized calcium (Ca++) are the physiologically active forms of these elements in the body and their concentrations have clinical value. Though the AVL988/4 instrument that measures concentrations of Mg++ and Ca++ has been evaluated, some clinically important parameters were unknown. In this study, we evaluated AVL988/4 analyzer for measuring Mg++ and Ca++ concentrations and provided the following information: (1) The newly formulated Becton Dickinson (BD) Vacutainer plastic tubes with clot activator and silicone as the stopper lubricant (serial no. 367820) caused a significant high bias for the Mg++ measurement but had no effect on the Ca++ measurement; (2) the optimal conditions for specimen storage were no exposure to air at 4 degrees C for up to 24 h; (3) no significant difference in the results of the Ca++ concentration determined using AVL988/4 or i-STAT; (4) no carryover between samples was found.

Autoanalysis↗

Sources of variability: a College of American Pathologists Therapeutic Drug Monitoring study.

OBJECTIVE: To determine the magnitudes and sources of analytic variation in testing for therapeutic drugs. Specifically, among laboratories using the same analytic method, to compare the within-laboratory variation (including both short- and long-term variation) with the between-laboratory variation. DESIGN: Four identical challenges were prepared from a lyophilized pool of spiked sera and were sent in pairs 4 months apart to laboratories participating in a nationwide proficiency-testing program. For each of 25 drugs, the variability in reported results from laboratories using the same method was investigated using nested analysis of variance. SETTING: The first 2 mailings of the College of American Pathologists Therapeutic Drug Monitoring Survey, 1996, sets Z and ZM. MAIN OUTCOME MEASURES: For each drug, total variance was partitioned into within- and between-laboratory components for common methods. The within-laboratory component was further partitioned into short- and long-term components. PARTICIPANTS: The approximately 5000 laboratories enrolled in the survey. RESULTS: For the 25 drugs, the average percentages of the total variance due to short-term, within-laboratory variance; long-term, within-laboratory variance; between-laboratory variance; and total laboratory variance were 25.0% (range, 8.8--50.6%), 57.8% (35.3--73.7%), 17.3% (5.0--35.4%), and 82.7% (64.6--95.0%), respectively. CONCLUSION: For all drugs tested, the within-laboratory component of variance was greater than the between-laboratory component of variance. Within laboratories, the magnitude of the long-term component was generally greater than the magnitude of the short-term component. This information will be helpful in determining the clinical utility of various drug assays and in evaluating the appropriateness of regulations involving therapeutic drug testing.

Analysis of Variance↗

An evaluation of analytic goals for assays of drugs: a College of American Pathologists Therapeutic Drug Monitoring Survey Study.

OBJECTIVE: To determine if the levels of imprecision of the commonly used analytic methods for drug measurements are suitable for long-term therapeutic drug monitoring. DESIGN: In 1996, 4 identical lyophilized samples (2 in the first mailing and 2 in the second mailing 4 months later) were sent to laboratories participating in a nationwide proficiency testing program. Similarly, in 1999, replicates from a liquid pool of spiked sera were mailed 3 times, 4 months apart, to participating laboratories. For each of 11 drugs regulated under the Clinical Laboratory Improvement Amendments of 1988 and 1 metabolite, the total variance for each method was partitioned into within- and between-laboratory components. The total within-laboratory and the total survey coefficients of variation (CVs) for each method were then compared with the "acceptable" precision criteria of Glick, Burnett, and Fraser for each drug. SETTING: The first 2 mailings of the College of American Pathologists Therapeutic Drug Monitoring surveys for 1996, sets Z and ZM, and the 3 mailings of 1999, sets ZM, Z, and Z2. MAIN OUTCOME MEASURES: For each drug studied, the CV of each method was compared with the various imprecision criteria, and if greater than any of the criteria, the method was then tabulated as not meeting that specific criterion.Participants.-The approximately 5000 participants of the survey. RESULTS: The number of methods deemed as not having acceptable total long-term within-laboratory precision by the various criteria ranged from 35% to 88% in 1996 and from 22% to 77% in 1999. CONCLUSION: The number of failures possibly indicates that many of the reagent assays being utilized are not precise enough for long-term therapeutic drug monitoring of chronically administered drugs or that the published criteria used to evaluate the data in this study are too stringent.

Data Collection↗

Acute hypermagnesemia and respiratory arrest following infusion of MgSO4 for tocolysis.

Hypermagnesemia (6.95 mmol/l) and respiratory arrest occurred to a 20-year-old female (G3P2002) at 26 weeks of gestation during tocolytic treatment with MgSO4.7H2O (density greater than plasmalyte) injected into an i.v. infusion bag containing 1 l of plasmalyte without mixing. The patient was rescued with calcium gluconate and normal pregnancy continued. It is important to adequately mix an i.v. solution after adding a drug particularly when the drug-containing solution has greater density than the parent i.v. solution.

Adult↗

Serum ionized magnesium: comparison of results obtained with three ion-selective analyzers.

In a two-center (Academic Medical Center, The Netherlands, and National Institutes of Health, USA) study, we compared ionized magnesium (iMg2+) results in serum determined with the AVL 988/4, KONE Microlyte 6 and NOVA CRT, which are the currently available analyzers equipped with a magnesium ion-selective electrode. The comparison was performed with frozen serum samples from normal individuals and patients. Imprecision and reference intervals were established. We found the best agreement between the KONE(x) and AVL(y) magnesium ion-selective electrodes (y= 0.972x-0.013; n=138) with samples from patients. With samples from normals, all three analyzers reported significantly different results (p<0.05). Best precision was found using the NOVA; coefficients of variation established at three levels were all < 4.0%. Coefficients of variation for the AVL and KONE were <5% at normal and high iMg2+, but 10.7 and 9.4%, respectively, at iMg2+ approximately 0.30 mmol/l. The reference intervals (mean+/-standard deviation) based on measurements in fresh serum samples were different for each analyzer: 0.55-0.63 mmol/l for AVL, 0.470.57 mmol/l for KONE and 0.43-0.55 mmol/l for NOVA. Thus, significant differences among the ionized magnesium concentration obtained with the three analyzers, limit comparison of results in clinical practice, and need to be resolved (e.g. by improvement of specificity and standardization of calibrators).

Adult↗

Magnesium in acute myocardial infarction: still an open question.

Many activities of magnesium have justified randomized controlled trials of its role in acute myocardial infarction (AMI), which have shown reduction of short term mortality by 25% to over 50%. The Fourth International Study of Infarct Survival (ISIS-4) megastudy failed to confirm these findings, and, based on analysis of pooled findings, it was concluded that magnesium has no place in treatment of AMI. The fixed effects statistical model employed in ISIS-4 for evaluation of pooled data is inappropriate because the studies were not homogeneous. Among the differences between the earlier studies and the megatrial, the most significant was the time at which magnesium infusions were started relative to the time of reperfusion. Animal studies have shown that magnesium is protective only if present before or at the time of reperfusion. Unlike in earlier trials, in which magnesium infusions were started soon after the ischemic event or simultaneously with a lytic agent, in ISIS-4 magnesium treatment was withheld until after iatrogenic or spontaneous reperfusion occurred. This can explain poor therapeutic results in ISIS-4, but not the hypotension and bradycardia encountered in a minority of patients in that study. Dosage difference alone cannot explain this, even though the amounts given in the small studies were 40% to 25% less than that in ISIS-4, because the dose used in the Second Leicester Intravenous Magnesium Intervention Trial (LIMIT-2) was only slightly lower than that used in ISIS-4. Administration of high dose magnesium with an angiotensin-converting enzyme inhibitor (which spares magnesium) or the vasodilating oral nitrate in arms of ISIS-4 may have contributed to adverse effects of hypermagnesemia. Also, the very low mortality rate of controls in ISIS-4 suggests that the patients may have been at relatively low risk, and it is in high risk patients that magnesium has been shown to be most effective. A large scale study of magnesium in such patients is being started.

Animals↗

Tyrphostin AG 556 improves survival and reduces multiorgan failure in canine Escherichia coli peritonitis.

Tyrosine kinase-dependent cell signaling is postulated to be a pivotal control point in inflammatory responses initiated by bacterial products and TNF. Using a canine model of gram-negative septic shock, we investigated the effect of tyrosine kinase inhibitors (tyrphostins) on survival. Animals were infected intraperitoneally with Escherichia coli 0111: B4, and then, in a randomized, blinded fashion, were treated immediately with one of two tyrphostins, AG 556 (n = 40) or AG 126 (n = 10), or with control (n = 50), and followed for 28 d or until death. All animals received supplemental oxygen, fluids, and antibiotics. Tyrphostin AG 556 improved survival times when compared to controls (P = 0.05). During the first 48 h after infection, AG 556 also improved mean arterial pressure, left ventricular ejection fraction, cardiac output, oxygen delivery, and alveolar-arterial oxygen gradient compared to controls (all P < or = 0.05). These improvements in organ injury were significantly predictive of survival. Treatment with AG 556 had no effect on clearance of endotoxin or bacteria from the blood (both P = NS); however, AG 556 did significantly lower serum TNF levels (P = 0.03). These data are consistent with the conclusion that AG 556 prevented cytokine-induced multiorgan failure and death during septic shock by inhibiting cell-signaling pathways without impairing host defenses as determined by clearance of bacteria and endotoxin.

Animals↗

Gender-specific correlation of platelet ionized magnesium and serum low-density-lipoprotein cholesterol concentrations in apparently healthy subjects.

We previously found an inverse correlation between platelet ionized magnesium concentration ((Mg2+)i) and serum total cholesterol concentration in normal male but not female subjects. In the present study, we determined the platelet (Mg2+)i by using a fluorescent ionized magnesium (Mg2+) indicator, FURAPTRA, and measured the serum concentrations of the following: total cholesterol; very-low-density lipoprotein cholesterol (VLDL-C); low-density lipoprotein cholesterol (LDL-C); high-density lipoprotein cholesterol (HDL-C); antioxidized low-density lipoprotein (LDL) autoantibodies; lipoprotein(a); apolipoproteins A-I (apo A-I) and B (apo B); triglycerides; estradiol-17 (E2); ceruloplasmin (Cp); and selected electrolytes, including total and ionized magnesium and calcium and total protein and albumin. In men, but not in women, platelet (Mg2+)i significantly inversely correlated with serum total cholesterol (r = -0.52, p < 0.02), LDL-C (r = -0.54, p < 0.009 by a "direct" method; r = -0.40, p < 0.05 by an electrophoretic method), and apo B (r = -0.42, p < 0.04). We found no significant correlations between platelet (Mg2+)i and any other variables, including serum total and ionized magnesium, antioxidized LDL autoantibodies, Cp, and E2. We speculate that decreased platelet (Mg2+)i is a possible marker for platelet membrane alterations that may affect platelet involvement in thrombosis and atherogenesis.

Adult↗

Clinically important intermethod differences for physiologically abnormal ionized magnesium results.

We compared physiologically abnormal low and high ionized magnesium (iMg) results determined with the AVL 988-4 (AVL, Graz, Austria) and Nova CRT (Nova Biomedical, Waltham, Mass) ion-selective electrodes (ISEs) in serum samples from randomly selected patients. A result of < 0.39 mmol/L with either ISE constituted the low magnesium group and of > or = 0.65 mmol/L the high magnesium group. Within each group we found significant differences between the iMg results. Major intermethod differences were found for samples with physiologically normal total magnesium concentration: most of the samples in the low magnesium group (83%) had abnormally low results with the Nova ISE, whereas most of the results with the AVL ISE (83%) were normal. In contrast, all results with the AVL ISE for the high magnesium group were abnormally high, but 67% of the results with the Nova ISE were normal. The agreement for the clinical interpretation of iMg results based on the reference interval for each method was only 32%. The differences in iMg results between the two analyzers must be resolved before using the iMg test as measured with ISE for patient care.

Blood Chemical Analysis↗

Serum ionized magnesium in chronic alcoholism: is it really decreased?

Chronic alcoholism is associated with a marked deficit in total magnesium (tMg). However, little is known about the status of the physiologically active form, ionized magnesium (iMg). We assessed serum iMg (measured with two ion-selective electrodes, AVL 988-4 and NOVA CRT) and tMg concentrations in chronic alcoholics at admission (n = 31) and after abstinence (n = 13) and compared these results with those for a control group (n = 40). At admission, the tMg and NOVA iMg concentrations in alcoholics (0.78 +/- 0.020 and 0.38 +/- 0.016 mmol/L, respectively) were significantly less (P <0.001) than in the controls (0.85 +/- 0.008 and 0.50 +/- 0.006 mmol/L). The AVL iMg results, however, did not differ significantly between the two groups: 0.53 +/- 0.013 vs 0.56 +/- 0.006 mmol/L, respectively (P >0.05). The mean iMg between the two analyzers differed significantly in both groups (P <0.001). After 3 weeks of abstinence, the alcoholics showed a significant increase in tMg (P <0.001) and in both NOVA and AVL iMg values (P <0.01 for each). tMg concentrations were positively correlated with the AVL iMg values in both alcoholics and controls but correlated positively with the NOVA iMg results only in the controls. Thus, the altered status of iMg is instrument-dependent, and the usefulness of the measurement in alcoholics is yet to be determined.

Adult↗

Positive interference in lithium determinations from clot activator in collection container.

We describe positive interference with the ion-selective electrode determination of lithium (Lytening 2Z analyzer; Dade) when blood is collected in a 10-mL plain red-top plastic Vacutainer Plus Tube (Becton Dickinson) containing a silica clot activator and silicone surfactant (prod. no. 36-7820). We evaluated both the original tube (blue-labeled) and a new tube formulated to contain less silicone surfactant (striped-labeled). We determined that the interference is from either the silica clot activator or the silicone surfactant used to fix the silica to the tube and is inversely related to the volume of blood in the tube. Long-term intermittent exposure of the Li ion-selective electrode to the silica clot activator or surfactant results in decreased Li values--in terms of both the positive interference by the silica clot activator or surfactant and the actual Li determinations. Moreover, this long-term interference with the Li ion-selective electrode for patient's specimens is undetected by the Dade control material (QCLytes).

Blood Coagulation↗

Thiocyanate in smokers interferes with the Nova magnesium ion-selective electrode.

Thiocyanate found in serum ordinarily is the metabolite of cyanide that is inhaled with tobacco smoke and ingested with cyanogenic foods. We investigated the effect of the thiocyanate ion (SCN-) on the ionized magnesium (iMg) and ionized calcium (iCa) results determined with the AVL and Nova magnesium and calcium ion-selective electrodes (ISEs). We analyzed saline and pooled serum with added SCN-, and serum from apparently healthy nonsmokers (n = 20) and smokers (n = 20). The mean (and range) of the measured serum SCN- concentration was 0.019 (0.008-0.046) mmol/L for nonsmokers and 0.077 (0.020-0.138) mmol/L for smokers. Only the Nova iMg results decreased with increasing SCN- concentration, and the change was dependent on the baseline iMg concentration. In the absence of Mg, SCN- decreased the voltage response of the Nova Mg ISE to calcium ions. At apparently normal serum iMg and iCa concentrations, the interference by SCN- appeared to be equimolar (iMg = -1.04 x SCN- + 0.52). Thus, the serum SCN- commonly found in smokers causes a significant (P < 0.0001) decrease in the Nova iMg results.

Artifacts↗

The effect of smoking on the serum ionized magnesium concentration is method-dependent.

OBJECTIVE: To investigate the effect of smoking on serum ionized magnesium concentration ([Mg2+]) determined by the NOVA and AVL Mg ion-selective electrodes (Mg ISEs). METHODS: Subjects were apparently healthy smokers (n = 30) and nonsmokers (n = 30). We determined NOVA and AVL [Mg2+] in their serum and in test solutions containing compounds increased by smoking. We also determined subjects' white blood cell and differential counts. RESULTS: For smokers, the mean values for NOVA and AVL [Mg2+] differed significantly (0.41 vs 0.52 mmol/L, respectively). We found a significant intramethod difference in NOVA [Mg2+] (0.11 mmol/L, P < .0001) between smokers and nonsmokers. A dose-dependent decrease in NOVA [Mg2+] was observed with an increase in cigarettes/day. NOVA [Mg2+] inversely correlated with white blood cell counts. There was no interference by the test compounds with either Mg ISE. CONCLUSION: Smoking may induce a serum factor, possibly related to white blood cells, that negatively interferes with the response of the NOVA Mg ISE.

Arachidonic Acid↗

Assessment of monoethylglycinexylidide as measure of liver function for patients with chronic viral hepatitis.

The liver metabolizes lidocaine by oxidative deethylation to form monoethylglycinexylidide (MEGX), an analyte proposed as an index of liver function. We determined MEGX and lidocaine serum concentrations with the TDx (Abbott Laboratories) at baseline and 15, 30, 60, and 90 min after the intravenous administration of lidocaine (1 mg/kg), analyzing specimens from 12 apparently healthy volunteers and 40 patients with chronic viral hepatitis diagnosed by liver biopsy and serum tests. The patients were grouped on the basis of the histology activity index. The following laboratory tests were performed on serum specimens from all subjects: albumin (ALB), alanine aminotransferase (ALT), aspartate aminotransferase (AST), alkaline phosphatase, total bilirubin, and prothrombin time. The results showed no significant difference among the four groups for the concentrations of MEGX, lidocaine, and lidocaine/MEGX at the four time points. However, the concentrations of ALB, ALT, AST, AST/ALT, and prothrombin time were substantially different among the four groups. Thus, we conclude that assay of MEGX in our patients with chronic viral hepatitis did not contribute to the assessment of liver function when compared with apparently healthy volunteers and traditional tests of liver function.

Adult↗

Falsely high ionized magnesium results by an ion-selective electrode method in severe hypomagnesemia.

Changes in serum total and ionized magnesium (Mg and Mg2+) and calcium (Ca and Ca2+) were monitored in three patients who transiently developed severe (total Mg < 0.50 mmol/l) to profound hypomagnesemia (total Mg < 0.35 mmol/l) due to cisplatin or interleukin-2 therapies. Mg2+ and Ca2+ were measured with the Nova ion-selective electrodes at 37 degrees C and all results were normalized to pH 7.40. Independent of the etiology, the Mg2+ fraction (Mg2+/total Mg) increased as the concentration of the serum total Mg decreased in all three patients. When the total Mg was around or below 0.35 mmol/l the Mg2+ approached or exceeded total Mg, suggesting an error in the measurement of Mg2+. The findings were extended by including a group of 31 additional patients whose serum total Mg, Mg2+, total Ca, and Ca2+ concentrations varied from abnormally low to above normal. The serum total and ionized concentrations strongly correlated for both Mg (r2 = 0.88) and Ca (r2 = 0.92). The Mg2+ fraction rapidly increased with a fall in the total Mg concentration (r2 = 0.76) and total Mg/total Ca ratio (r2 = 0.71). In fact, with decreasing total Mg concentrations or total Mg/total Ca ratios, the Mg2+ fraction progressively increased to 93-128% of the total, confirming an error in the Mg2+ determinations. The Ca2+ fraction showed a slight and insignificant decrease with falling total Ca concentrations and total Mg/total Ca ratios. The Mg2+ concentration was directly related (r2 = 0.62), whereas the Ca2+ concentration showed a complex relationship to the total Mg/total Ca ratio. Whether this latter relationship represents a technical artifact or a true biological phenomenon requires further study. The apparent overestimation of Mg2+ at very low total Mg concentrations, and in the presence of a very low total Mg/total Ca ratio, could be due to improper chemometric correction of the Ca effect on the Mg electrode, non-linearity, and inadequate calibration. Whatever the mechanism, the failure of this method to correctly measure very low serum Mg2+ concentrations in the sera of patients with severe hypomagnesemia, or likely in any patient with an unusually low total Mg/total Ca ratio, erodes its diagnostic usefulness.

Adult↗