Publications and source records attributed to R J Van Woersem.

2 recordsLinked to original sources

Transesophageal atrial pacing--stimulation and discomfort thresholds: the role of electrode configuration and pulse width.

A balloon catheter with six electrodes has been developed for transesophageal atrial stimulation of the human heart. Introduction is easy and its positioning is simple with the help of six unipolar atrial electrograms. In a group of 20 healthy volunteers, stimulation and discomfort thresholds (intolerable discomfort) were measured for three levels of pulse widths (12, 16, and 20 msec) and for five electrode configurations. Stimulation thresholds were below discomfort thresholds in each case. The stimulation threshold depended on pulse width and not on electrode configuration. The discomfort threshold, however, depended on the electrode configuration and not on the pulse width. A moderate but potentially important increase of the ratio between stimulation threshold and discomfort threshold could be achieved by combining a long pulse width (20 msec) and avoiding the largest distance between the active (cathode) and the passive (anode) electrode. Transesophageal atrial stimulation promises to be a practical noninvasive tool for the termination of regular supraventricular tachycardias, basal electrophysiological studies, and controlled acceleration of the heart rate in the study of myocardial ischemia.

Adult↗

Improved rate responsive algorithm in QT driven pacemakers--evaluation of initial response to exercise.

The QT pacemaker is a rate modulated pacemaker that uses the evoked QT interval as an indicator to determine its optimal pacing rate. Despite the generally favorable clinical results with this form of pacing, some flaws in the system have been reported, such as the frequently observed rather slow initial response of the pacing rate to physical exercise, and the phenomenon of oscillation of the heart rate. These problems can be attributed to the rate adaptive algorithm used in the current QT pacemaker. Recently, in a reexamination of the relationship between evoked QT interval and pacing rate, a curvilinear relationship between these parameters has been demonstrated. As a result, a new algorithm has been developed for the next generation of the QT pacemaker. Before this new algorithm was implemented in new implantable devices, it was evaluated in a multicenter clinical investigation, with emphasis on the initial response of the pacing rate to exercise. This study was carried out by means of special software in the programmer of the QT pacemaker. By employing real-time bidirectional telemetry, it was possible to submit the study population, consisting of 37 patients with implanted QT pacemakers of the current generation, to identical exercise tests. Comparing these exercise tests, it appears that a considerable gain in speed of response to exercise can be achieved by using the same sensor with a faster reacting, nonlinear rate adaptive algorithm.

Aged↗