Radio-frequency survey at the bore of a 1.5-T MR imager.

A survey at the bore of a 1.5-T magnetic resonance (MR) imager assessed radio-frequency (RF) exposure. With variable pulse sequences and loading conditions, the RF power density at relevant occupational positions was below measurable limits (less than the threshold limit value for occupational workers of 1 mW/cm2). Exposure to RF fields is below safe limits for personnel who routinely work within an MR imaging suite.

Humans

The radiation dosimetry and normal value study of 99mTc-HMPAO-labeled leukocytes.

RATIONALE AND OBJECTIVES: Indium-111 (111In)-labeled leukocyte scanning has been used frequently in patients suspected of having infections. Recently, technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO) has been used to label leukocytes. This study was undertaken to determine the distribution and dosimetry of 99mTc-HMPAO leukocytes in healthy subjects. METHODS: Five healthy volunteers had leukocytes labeled with 99mTc-HMPAO. After injection of the labeled leukocytes, whole body images and blood and urine samples were obtained at multiple time points. RESULTS: Visual interpretation of the images demonstrated significant bowel activity as early as 2 hours and increasing with time such that one the 8- and 24-hour images, the amount of bowel activity would preclude using 99mTc-HMPAO leukocyte scanning for abdominal processes. The dosimetry for this study is similar to that of other studies and is in an acceptable diagnostic range. CONCLUSIONS: 99mTc-HMPAO leukocyte studies are an acceptable alternative to 111In-labeled leukocyte studies in terms of dosimetry. Use of such studies in the abdomen should be limited to early images, usually before 2 hours, to avoid confusion with the normal route of excretion in the bowel.

Female

Dosimetry and biodistribution of an iodine-123-labeled somatostatin analog in patients with neuroendocrine tumors.

A modified method for the preparation of a radiolabeled analog of somatostatin (123I-octreotide) is described. The pharmacokinetics and dosimetry of this analog were evaluated in patients with neuroendocrine tumors. Thirty patients had multiple blood and urine samples and sequential anterior and posterior whole-body scintigraphy up to 40 hr postinjection of 123I-octreotide. Region of interest analysis of the whole-body images was used to determine organ and tumor doses. The 123I-octreotide was rapidly cleared from the blood with a T 1/2 of 10 min by the hepatobiliary system. By 40 hr, approximately 55% was eliminated in the feces. The gallbladder wall received the highest dose (0.48 rad/mCi), with other organs receiving doses of 0.12 rad/mCi or less. Tumors were identified in 25 of 28 satisfactory studies. Tumor doses ranged from 0.1 to 0.6 rad/mCi. Calculations with 131I instead of 123I indicated that the gallbladder wall would receive 2 rad/mCi, while average tumor doses would range from 0.9 to 5.0 rad/mCi. Iodine-123-octreotide is a useful agent for the visualization of neuroendocrine tumors. The rapid washout of this agent from tumors precludes the possibility of radiotherapy with 131I-octreotide in these patients.

Endocrine Gland Neoplasms

Effect of pulsed progressive fluoroscopy on reduction of radiation dose in the cardiac catheterization laboratory.

The increased application of therapeutic interventional cardiology procedures is associated with increased radiation exposure to physicians, patients and technical personnel. New advances in imaging techniques have the potential for reducing radiation exposure. A progressive scanning video system with a standard vascular phantom has been shown to decrease entrance radiation exposure. The effect of this system on reducing actual radiation exposure to physicians and technicians was assessed from 1984 through 1987. During this time, progressive fluoroscopy was added sequentially to all four adult catheterization laboratories; no changes in shielding procedures were made. During this time, the case load per physician increased by 63% and the number of percutaneous transluminal coronary angioplasty procedures (a high radiation procedure) increased by 244%. Despite these increases in both case load and higher radiation procedures, the average radiation exposure per physician declined by 37%. During the same time, the radiation exposure for technicians decreased by 35%. Pulsed progressive fluoroscopy is effective for reducing radiation exposure to catheterization laboratory physicians and technical staff.

Angioplasty, Balloon, Coronary

Measurement of body potassium with a whole-body counter: relationship between lean body mass and resting energy expenditure.

We conducted studies to determine whether the Mayo whole-body counter could be used to measure body potassium, and thus lean body mass (LBM), and whether moderate obesity alters resting energy expenditure when corrected for LBM. Twenty-four nonobese and 18 moderately obese adults underwent body potassium (40K) counting, as well as tritiated water space measurement and indirect calorimetry. LBM values predicted from 40K counting and tritiated water space measurements were highly correlated (P = 0.001; r = 0.88). Resting energy expenditure was closely related to LBM (P less than 0.0001; r = 0.78): kcal/day = 622 kcal + (LBM.20.0 kcal/kg LBM). In this relationship, the obese subjects did not differ from nonobese subjects. In summary, the Mayo whole-body counter can accurately measure LBM, and moderate obesity has no detectable effect on corrected resting energy expenditure.

Adult

Radiation exposure of fertile women in medical research studies.

Fertile women may be exposed to ionizing radiation as human subjects in medical research studies. If the woman is pregnant, such exposures may result in risk to an embryo/fetus. Fertile women may be screened for pregnancy before exposure to ionizing radiation by interview, general examination, or pregnancy test. Use of the sensitive serum pregnancy test has become common because it offers concrete evidence that the woman is not pregnant (more specifically, that an embryo is not implanted). Evidence suggests that risk to the embryo from radiation exposure before organogenesis is extremely low or nonexistent. Further, demonstrated effects on organogenesis are rare or inconclusive at fetal doses below 50 mSv (5 rem). Therefore, there may be some level of radiation exposure below which risk to the fetus may be considered essentially zero, and a serum pregnancy test is unnecessary. This paper reviews the fetal risks and suggests that consideration be given to establishing a limit to the fetus of 0.5 mSv (50 mrem), below which pregnancy screening need not include the use of a serum pregnancy test.

Abnormalities, Radiation-Induced