Generating accurate finite element meshes for the forward model of the human head in EIT.

The use of realistic anatomy in the model used for image reconstruction in EIT of brain function appears to confer significant improvements compared to geometric shapes such as a sphere. Accurate model geometry may be achieved by numerical models based on magnetic resonance images (MRIs) of the head, and this group has elected to use finite element meshing (FEM) as it enables detailed internal anatomy to be modelled and has the capability to incorporate information about tissue anisotropy. In this paper a method for generating accurate FEMs of the human head is presented where MRI images are manually segmented using custom adaptation of industry standard commercial design software packages. This is illustrated with example surface models and meshes from adult epilepsy patients, a neonatal baby and a phantom latex tank incorporating a real skull. Mesh quality is assessed in terms of element stretch and hence distortion.

Algorithms↗

Electrical impedance tomography spectroscopy (EITS) for human head imaging.

Electrical impedance tomography (EIT) is a recently developed medical imaging method which has practical advantages for imaging brain function as it is inexpensive, rapid and portable. Its principal use in validated human studies to date has been to image changes in impedance at a single excitation frequency over time, but there are potential applications where it is desirable to obtain images from a single point in time, which could be achieved by imaging over multiple frequencies. We describe a novel multifrequency EIT design which provides up to 64 electrodes for imaging in the head. This was achieved by adding a multiplexer to a single channel of an existing system, the Sheffield Mark 3.5. This provides a flexible protocol for addressing up to 64 electrodes but CMRR decreases from 90 dB to 80 dB and analogue amplifier bandwidth from > 1.6 MHz to 0.8 MHz. This did not significantly affect performance, as cylinders of banana, 10% of the diameter of a saline filled spherical tank, could be visualized with frequency referenced imaging. The design appears to have been an acceptable compromise between practicality and performance and will now be employed in clinical trials of multifrequency EIT in stroke, epilepsy and neonatal brain injury.

Electric Impedance↗

A comparison of headnet electrode arrays for electrical impedance tomography of the human head.

Three types of commercially available headnet electrode arrays, designed for use in EEG, and conventional EEG Ag/AgCl cup electrodes were tested on human subjects, and a realistic, saline-filled head-shaped tank was prepared with vegetable skin to simulate human skin in order to determine the optimum electrode system for electrical impedance tomography (EIT) of the human head. Impedance changes during EIT acquisition were produced in healthy volunteers during a finger-thumb apposition task and in tanks by the insertion of a Perspex rod. Signal-to-baseline noise, measured from raw EIT data, was 2.3 +/- 0.3 and 2.3 +/- 0.2 for the human and tank data, respectively. In both the human and tank experiments, a commercial hydrogel elasticated electrode headnet produced the least amount of baseline noise, and was the only headnet in the human data with noise levels acceptable for EIT imaging. Image quality measured in the tank was similar for most of the headnets tested, except that the EEG electrodes produced a higher positional error and electrodes in a geodesic elasticated net produced images with worse subjective image quality. Overall, the hydrogel elasticated headnet was judged to be the most suitable for human neuroimaging with EIT.

Adult↗

Mapping liquid distribution in absorbent incontinence products.

This paper reviews methods available for mapping the distribution of fluid in incontinence pad materials to assist with evaluating existing products and developing new ones, and to provide data for building and validating predictive models. Specifically, the following technologies are considered and their strengths and limitations described: discrete sensors based on conductance, temperature or optical measurements, optical imaging, gravimetric methods, X-ray imaging and magnetic resonance imaging. It is suggested that the ideal method would enable fluid distribution to be mapped in three dimensions with good spatial and time resolution in single materials and composite structures of simple and complex geometries under static and dynamic mechanical loading. It would also allow liquid to be mapped in products when worn by users. It is concluded that, although each existing method meets some of these requirements, and each requirement is met, at least reasonably well, by at least one method, improved techniques are needed. The particular need for methods that can provide some measurement of liquid saturation within absorbent products, both in the laboratory and in real use, is highlighted. In many cases, simple methods used appropriately are sufficient to elicit the important aspects of liquid transport and storage within absorbent products.

Absorption↗

Design and performance of the UCLH mark 1b 64 channel electrical impedance tomography (EIT) system, optimized for imaging brain function.

The UCLH Mark 1b is a portable EIT system that can address up to 64 electrodes, which has been designed for imaging brain function with scalp electrodes. It employs a single impedance-measuring circuit and multiplexer so that electrode combinations may be addressed flexibly using software. It operates in the relatively low frequency band between 225 Hz and 77 kHz, as lower frequencies produce larger changes during brain activity, and has a videocassette-sized headbox on a lead 10 m long, connected to a base box the size of a video recorder, and notebook PC, so that recordings may be made in ambulant subjects. Its performance was assessed using a resistor-capacitor network, and two saline-filled tanks-a cylindrical Perspex one and a latex one which contained a human skull. System signal-to-noise ratio was better than 50 dB and the maximum reciprocity error less than 10% for most frequencies. The CMMR was better than 80 dB at 38 kHz and a sponge, 20 mm across, which caused a local 12% impedance increase, was correctly localized in images. This suggests that the system has adequate performance to image impedance changes of 5-50% known to occur in the brain during normal activity, epilepsy or stroke; clinical trials to image these conditions are in progress.

Brain↗