PubMed Health⌕ Search

Biomedical subjects

R Jacobs

Publications and source records attributed to R Jacobs.

At least 37 records · Page 2Linked to original sources

Dosimetry of digital panoramic imaging. Part II: Occupational exposure.

OBJECTIVES: To measure occupational radiation dose during panoramic exposure from five digital panoramic X-ray units. METHODS: Exposures were made with five different digital panoramic units, of which four were equipped with a direct digital CCD (charge coupled device, "direct digital" technique), and one used storage phosphor plates ("indirect digital" technique). An anthropomorphic phantom served as the patient. An ionization chamber recorded the scattered radiation at 1 m from the phantom at five different locations around the panoramic units, both at the level of the thyroid gland and the level of the gonads, and effective organ doses were calculated. Exposure parameters were set as recommended by the manufacturers for the particular image and patient size: tube potential settings ranged between 64 kV and 74 kV, exposure times between 8.2 s and 19.0 s, tube current values between 4 mA and 7 mA. RESULTS: The maximum organ equivalent dose at 1 m from the panoramic unit was 0.60 microGy, the maximum organ effective dose was 0.10 microSv. Organ equivalent doses varied between 0.18 microGy and 0.30 microGy and organ effective doses between 0.01 microSv and 0.05 microSv for the different positions around the units (average for the different panoramic units). The variations in organ doses for the various machines were 0.04-0.53 microGy organ equivalent dose and 0.01-0.08 microSv organ effective dose. CONCLUSIONS: Assuming that 500 panoramic radiographs per year are taken by a dental practitioner at 1 m distance from the panoramic unit, he or she will receive an annual additional organ effective dose between 5 microSv and 15 microSv for the thyroid gland and between 5 microSv and 40 microSv for the gonads, depending on the type of digital panoramic unit.

Dentists↗

Microanatomical and histological assessment of the content of superior genial spinal foramen and its bony canal.

OBJECTIVES: To assess histologically the true content of the superior genial spinal foramen and to match these findings to the microanatomical canal content observed using high-resolution magnetic resonance images of the same region. METHODS: Ten human mandibular specimens were imaged using a 9.4 Tesla MRI unit. Afterwards, eight specimens were decalcified, embedded in paraffin and serially sectioned (7 microm) for histological examination; the remaining two were embedded in methylmethacrylate and sectioned (50-60 microm). All sections were examined using routine light microscopy to inspect the superior genial spinal foramen region and its content. RESULTS: Histological observations of the superior genial spinal foramen confirmed the presence of a well-defined neurovascular bundle, with branches of the lingual nerve and lingual artery. The canal had an average diameter exceeding 1 mm and could thus be considered significant. CONCLUSIONS: The present study confirms the existence of a true superior genial spinal foramen's bony canal with neural and blood vessel content. These findings imply that surgical procedures should consider a proper preoperative assessment of the neurovascular trajectory of the superior genial spinal foramen.

Arteries↗

Radiation doses of indirect and direct digital cephalometric radiography.

AIM: The aim of this study was to measure organ doses and calculate the effective dose for indirect and direct digital cephalometric exposures. MATERIAL AND METHODS: Indirect digital cephalometric exposures were made of a Rando phantom head using a Cranex Tome multipurpose unit with storage phosphor plates from Agfa and the direct digital (Charge Coupled Device, CCD) exposures were made with a Proline Ceph CM unit. Exposure settings were 70 kV and 4 mAs for indirect digital exposures. Direct digital exposures were made with 70 kV, 10 mA and a total scanning time of 23 s. TLD700 dosemeters were used to measure organ doses, and the effective doses were calculated with (effective dose(sal)) and without inclusion of the salivary glands. A pilot study was carried out to compare diagnostic image quality of both imaging modalities. RESULTS: Effective doses were 1.7 microSv for direct digital and 1.6 microSv for indirect digital cephalometric imaging. When salivary glands were included in the calculation, effective doses(sal) were 3.4 microSv and 2.2 microSv respectively. Organ doses were higher for direct digital imaging, except for the thyroid gland, where the organ doses were comparable. Diagnostic image quality of indirect and direct digital cephalometric images seemed comparable. CONCLUSION: Effective dose and effective dose(sal) were higher for direct digital cephalometric exposure compared with indirect digital exposure. Organ doses were higher for direct digital cephalography. From preliminary data, it may be presumed that diagnostic image quality of indirect and direct digital cephalometric images are comparable.

Cephalometry↗

Appearance of the mandibular incisive canal on panoramic radiographs.

Panoramic radiographs are routinely used in the dental office for various diagnostic purposes. This study aimed to evaluate the visibility of neurovascular structures in the mandibular interforaminal region on such radiographs. Panoramic radiographs were obtained with a Cranex Tome (Soredex) from 545 consecutive patients using a standard exposure and positioning protocol. For visibility scoring of neurovascular structures, a four-point rating scale was used. The mandibular canal and the mental foramen could be observed in the majority of the cases with good visibility. The lingual foramen was visualized in 71% of the cases, with good visibility in 12%. An incisive canal was identified in 15% of the images, with good visibility in only 1%. An anatomical variation to be considered is the anterior looping of the mental nerve (in 11% of images). Panoramic radiographs can be used for visualization of the mental foramen and a potential anterior looping but not for locating the mandibular incisive canal. To verify its existence for preoperative planning purposes, cross-sectional imaging modalities (HR-CT or spiral tomography) should be preferred.

Adult↗

A potential link between oral status and hearing impairment: preliminary observations.

Some previous studies suggest an association between tooth loss and hearing loss. The aim of this study is to assess the relation between oral status and hearing acuity. Forty-eight patients (mean age: 64.7 years) were allocated to four groups: one was wearing complete dentures in both jaws, another had shortened dental arches, a third had full dental arches in both jaws and the last lacked any occlusal stops (i.e. no occlusal vertical dimension, because of the absence of teeth or occlusal pairs). Audiological testing was performed in a noise-free chamber. Air and bone conduction were checked at different frequencies and the air-bone gap was determined. After correction for age and gender, a difference in air and bone conduction because of the oral status was found for low and for high frequencies while no significant differences were (P < 0.05) found for the air-bone gap. The number of teeth, number of occluding tooth pairs and presence or lack of occlusal vertical dimension, was significantly related to the gradient of hearing loss (P < 0.05). The discrepancy in hearing loss between complete denture wearers and patients without any occlusal vertical dimension, strengthens the hypothesis that it is the lack of the latter that is associated with hearing loss. At what level hearing loss occurs, needs further investigation.

Aged↗

The immediate rehabilitation by means of a ready-made final fixed prosthesis in the edentulous mandible: a 1-year follow-up study on 50 consecutive patients.

Although a two-stage procedure with symphyseal oral implants can lead to a long-term (15 years) 99% cumulative survival rate, a one-stage approach with immediate loading via prefabricated elements seems to offer a short-term acceptable outcome with significantly lower costs. A series of 50 consecutive patients, not eliminated for any systemic or smoking condition, received at the department of periodontology three implants in the symphyseal area, connected by a very rigid horse shoe-shaped titanium bar. A final screw retained prosthetic framework was placed on top of it at the department of prosthetic dentistry within 2 days after surgery (44) or after a delay, due to purely external factors, of up to 10 days (6). Forty-five patients were followed for 1 year. In one patient, all three implants failed and another four patients were lost to follow-up. The cumulative failure rates for implants and prostheses at 1 year were, respectively, 7.3% and 5%. The mean marginal bone loss at 1 year was 1.08 mm (SD: 1.62; range -5.68 to +2.55). This study shows that stable marginal bone levels can be maintained around immediately loaded implants in the lower jaw in an average patient population for at least 1 year. The survival rate is, however, lower than for a staged approach.

Aged↗

Attitude of the Belgian dentist population towards radiation protection.

OBJECTIVES: To perform a survey of private dental offices in Belgium and gain insight in the knowledge and attitude of Belgian dentists towards quality care in radiography and radiation protection. METHODS: A questionnaire was distributed among 700 Belgian dental offices, which were included based on demographic data and the use of intraoral radiographic equipment. RESULTS: The response rate was 71%. Implementation of standards for quality care and radiation protection was suboptimal. In most offices, exposure settings of the intraoral radiation tube were 65 kV/kVp to 70 kV/kVp and 10 mA to 12 mA, with an average exposure time of 0.45 s. No reduction of exposure time was noticed when using faster film types. About one-third of the responders worked with digital image receptors. Aiming devices and rectangular collimation were used in a minority of practices (40% and 6%, respectively). The distance of the dentist to the radiation tube during exposure was on average 2.2 m, although 8% of the dentists assisted in holding the image receptor inside the patient's mouth. One quarter of the dentists were standing behind a wall when taking radiographs. Lead aprons were worn more often by female dentists. Dose estimation revealed that male dentists received a significantly larger effective dose per year than female dentists (8.3 mSv vs 3.2 mSv). CONCLUSIONS: The implementation of standards of quality care for radiography and radiation protection could be improved among Belgian dentists. An elaborate educational programme in dental radiography is a prerequisite. Furthermore, recommendations could help to attain a change in attitude towards the use of ionizing radiation in order to meet European guidelines.

Adult↗

The nasopalatine canal revisited using 2D and 3D CT imaging.

OBJECTIVES: To assess the location, morphology and dimensions of the nasopalatine canal on two-dimensional and three-dimensional (2D and 3D) CT images. METHODS: Material included 34 spiral CT scans for pre-operative planning of implant placement in the maxilla. Scanning was performed using a standard exposure and patient positioning protocol. 2D and 3D spiral CT images were carefully examined for the location, morphology and dimensions of the nasopalatine canal by two independent observers. A comparison was made between 2D observations and a 2D/3D combined observation strategy (paired t-tests). RESULTS: The nasopalatine canal typically appeared as a canal with a mean (standard deviation (SD)) length of 8.1 (3.4) mm. Its palatal opening is the incisive foramen with a mean (SD) inner Ø of 4.6 (1.8) mm. At the level of the nasal floor often 2 (Y-canal morphology), but sometimes 3 or 4 openings could be observed. In particular cases, the canal showed up as a cylinder with only one nasal opening. The average (SD) maximum width of the nasopalatine canal structure at the level of the nasal floor was 4.9 (1.2) mm. The buccopalatal width of the jaw, anterior to the canal was 7.4 (2.6) mm. Interpretation of canal morphology was significantly different when comparing 2D image observation with a 2D/3D combined observation strategy. However, dimensional measurements of the canal were not significantly different for a 2D and a combined 2D/3D approach. CONCLUSIONS: The nasopalatine canal may show important anatomical variations, both with regard to morphology and dimensions. To avoid any potential complications during surgical procedures such as implant placement, a careful pre-operative observation is required. Cross-sectional imaging may be advocated to determine canal morphology and dimensions and to assess anterior bone width for potential implant placement buccally to the canal.

Adult↗

Presence and course of the incisive canal in the human mandibular interforaminal region: two-dimensional imaging versus anatomical observations.

The objective of the present study was to evaluate the presence and course of the incisive canal in the mental interforaminal region of the human mandible and to describe the occurrence of anatomical variations. Mandibles of 50 adult human cadavers were retrieved from the Department of Anatomy of the Faculty of Medicine, Katholieke Universiteit Leuven (Leuven, Belgium). Forty mandibles were edentulous, while 10 mandibles were partially dentate. Intra-oral, panoramic and tomographic imaging of the interforaminal region of the human mandible were performed. Afterwards, mandibles were sawn into vertical sections according to the respective tomographic cross-sections. The latter allowed exploration for the presence and course of an anterior prolongation of the mandibular canal. Measurements of the location of the incisive canal towards the base of the mandible were made using a digital-sliding caliper. Results indicated a well-defined incisive canal [mean (SD) inner diameter 1.8 (0.5 mm)], macroscopically observed in 96% of mandibles. The incisive canal was located on average 9.7 mm (SD 1.8 mm) from the lower cortical border and continued towards the incisor region in a slightly downward direction, with a mean (SD) distance to the lower cortical border of 7.2 (2.1) mm. It was concluded that there is an anterior intraosseous extension of the mandibular canal, denoted as the incisive canal. The latter might be considered as a true anterior extension of the neurovascular bundle. Histological and neurophysiological studies are needed to verify this hypothesis and evaluate its potential clinical implications.

Adult↗

Inverted eruption of a supplemental lower premolar: report of an unusual case.

Eruption of an inverted tooth is a rare condition. This case report describes the inverted eruption of a supplemental lower premolar in a 10-year-old Caucasian female. The tooth erupted in a downward direction and reached the lower cortical border of the mandible 2 years later. During an 8-year follow-up period, the tooth did not interfere with eruption of permanent teeth and the patient remained symptom-free. Considering clinical examination, medical and dental history as well as scientific evidence, the inverted eruption was most likely caused by a developmental abnormality with an inverted location of the tooth bud. This reported eruption of an inverted tooth is extremely rare and requires a radiographic follow-up to evaluate the relative position of this tooth in the jaw bone and its potential interference with neighbouring teeth or anatomic structures.

Bicuspid↗

Radiation doses of collimated vs non-collimated cephalometric exposures.

OBJECTIVES: The aim of the study was to compare organ and effective radiation doses for collimated and non-collimated cephalometric radiographs made by a multipurpose extraoral radiation unit. METHODS: Cephalometric exposures were made from a Rando head phantom representing an average man with the Cranex Tome multipurpose radiation unit. A collimator was fabricated from a 3-mm thick piece of lead. The collimator was designed so that structures relevant for orthodontic diagnosis were not shielded, whereas the thyroid gland and the major part of the skull were shielded. Absorbed organ doses were measured using thermoluminescent dosimeters. The effective dose was calculated both with (E(sal)) and without (E) inclusion of the salivary glands. RESULTS: Use of a wedge-shaped lead collimator yielded a reduction in field size of 55% and a reduction in E from 3.0 micro Sv to 1.6 micro Sv (47%) and in E(sal) from 3.7 micro Sv to 2.2 micro Sv (41%). CONCLUSIONS: Use of a wedge-shaped collimator should be advocated in all cases where depiction of the thyroid gland and the neurocranium is not required. The resulting reduction in effective dose using our collimator was 47% (41% when the salivary glands are included), which is of clinical importance, especially in children.

Bone Marrow↗

The influence of oral implant-supported prostheses on articulation and myofunction.

The aim of the present research was to assess articulation and myofunction in patients wearing fixed or removable prostheses supported by oral implants. 164 edentulous patients with implant supported prostheses were divided in four subgroups, dependent on their dental status, and compared to control groups of forty five subjects having a natural dentition. More than fifteen articulatory and myofunctional parameters were evaluated. The results showed that subjects with prostheses on implants tend to have more articulation problems than controls. Especially patients with a complete fixed prosthesis on implants in the upper jaw seemed to experience problems pronouncing /s/ and /z/. There also seemed to be influences of age and hearing factors.

Adult↗

Appearance, location, course, and morphology of the mandibular incisive canal: an assessment on spiral CT scan.

OBJECTIVES: To assess the appearance, location, and course of the incisive canal as compared to other anatomical landmarks on spiral CT of the mandible. METHODS: Study material included 230 spiral CT scans taken for preoperative planning of implant placement in the posterior mandible. All scanning was performed using a standard exposure and patient positioning protocol. Axial, panoramic, and reformatted cross-sectional images were carefully examined. Visibility of the incisive canal and other anatomical landmarks was scored using a four-point rating scale. The vertical and buccolingual diameter of the outer contour as well the diameter of the inner contour of the incisive canal were measured using a digital sliding caliper. RESULTS: An incisive canal was identified in 93% of the cases, with good visibility in 22% of the cases. Mean (s.d.) vertical diameter, buccolingual diameter, and inner diameter of the incisive canal were 4.7 (1.1), 3.7 (0.7), and 1.1 (0.3) mm respectively. The mandibular canal, mental foramen, lingual foramen, and anterior looping appeared in 98, 100, 82 and 7% of the images respectively. CONCLUSIONS: A well-defined incisive canal could be detected in the majority of spiral CT scans. Its radiographic detection remained lower than for the mandibular canal or mental foramen, but higher than for the visibility of the lingual foramen. Visualisation of the incisive canal and the occasional presence of an anterior looping, demonstrates the potential value of cross-sectional imaging of the anterior mandible for presurgical planning purposes.

Adolescent↗

Perioperative validation of localisation of the mental foramen.

AIM: To assess the accuracy of panoramic radiography and spiral or computed tomography for the localisation of the mental foramen. MATERIALS AND METHODS: The distance from the alveolar crest to the mental foramen was measured from panoramic radiographs, spiral tomograms and CT scans. The same distance was measured during implant surgery using a specially designed caliper. RESULTS: Panoramic radiography showed more deviation (+0.6 mm) from the perioperative measurements than either spiral or computed tomography (+0.4 and -0.3 mm respectively). The difference was significant (P<0.05). In general, distances were overestimated on the panoramic radiographs. CONCLUSIONS: Cross-sectional imaging techniques are recommended for the pre-operative planning of implants in the posterior mandible.

Adult↗

A comparison of the effective dose from scanography with periapical radiography.

OBJECTIVES: To compare organ and effective doses from analogue scanographic and periapical radiography. METHODS: Thermoluminescent dosimeters (TLD-700) were inserted in the parotid glands (bilateral), submandibular glands (bilateral) and bone marrow (left ascending ramus) of three human cadavers. Dosimeters were also attached to the skin, thyroid gland and lens of both eyes. Central, left lateral and left posterior scanograms were obtained with a Cranex Tome (Soredex, Helsinki, Finland) multimodal imaging system. A similar procedure was applied for periapical radiographs of the midline, left lateral and left molar regions using E-speed film both with and without rectangular collimation. Organ and effective doses were calculated for scanograms and periapical radiographs. RESULTS: The effective doses for the scanograms were 0.001 mSv (central), 0.011 mSv (lateral) and 0.015 mSv (posterior). The effective doses for periapical radiographs were 0.001 mSv (anterior), 0.001 mSv (lateral) and 0.003 mSv (posterior) for rectangular collimation and 0.001 mSv (anterior), 0.002 mSv (lateral) and 0.005 mSv (posterior) for round collimation. CONCLUSIONS: When a larger area of the upper or lower jaw needs to be visualised, scanograms might be considered as an alternative to periapical radiography since the effective dose is lower.

Bone Marrow↗

The accuracy and reliability of radiographic methods for the assessment of marginal bone level around oral implants.

OBJECTIVES: To determine the accuracy and reliability of radiographic methods for assessment of the marginal bone level around oral implants in human cadavers. METHODS: In three human cadavers two implants were placed according to the Instruction Manual for the Brånemark System. One implant was installed in the canine and one in the premolar region of the left mandible. For each implant, conventional and digital intra-oral paralleling radiography were performed. Digital images were printed with a Kodak 1200 Distributed Medical Imaging printer on blue transparent film, glossy and plain paper. Furthermore, digital scanographic, panoramic and tomographic images were taken with the Cranex Tome multimodal X-ray unit and printed on Agfa Drystar TM 1 B transparent films. All images were evaluated by five dental specialists. Data were statistically compared with real measurements of the marginal bone level on the human cadavers, performed by the same group of observers. Intra- and inter-observer variability were determined. RESULTS: Digital intra-oral images on glossy paper showed the smallest absolute difference between real and measured bone level, followed by digital intra-oral images on film and on plain paper, conventional intra-oral images on analogue film, panoramic, scanographic and tomographic images on film. The difference between real and radiographic measurements was not statistically significant (P>0.05) for all radiographic techniques. Intra- and inter-observer reproducibility was high for all techniques. CONCLUSIONS: The selected imaging techniques showed an acceptable accuracy for peri-implant bone level measurements with an overall error of less than 0.5 mm. Intra-oral images showed the smallest absolute differences.

Alveolar Process↗

Methodology of oral sensory tests.

Different methods of oral sensory tests including light touch sensation, two-point discrimination, vibrotactile function and thermal sensation were compared. Healthy subjects were tested to assess the results obtained from two psychophysical approaches, namely the staircase and the ascending & descending method of limits for light touch sensation and two-point discrimination. Both methods appeared to be reliable for examining oral sensory function. The effect of topical anaesthesia was also evaluated but no conclusion could be drawn as too few subjects were involved. Newly developed simple testing tools for two-point discrimination and thermal sensation in a clinical situation were developed prior to this study and tested for their reproducibility. Thermal sensation could be reliably detected in repeated trials. Although the hand-held instruments have some drawbacks, the outcome of these instruments in a clinical environment is suitable for assessing oral sensory function. Three different frequencies (32, 128 and 256 Hz) were used to estimate the vibrotactile function. Different threshold levels were found at different frequencies.

Adolescent↗