PubMed Health⌕ Search

Biomedical subjects

R Jenni

Publications and source records attributed to R Jenni.

At least 55 records · Page 3Linked to original sources

Surgical treatment of acquired left ventricular pseudoaneurysms.

BACKGROUND: We present a review of our experience with acquired pseudoaneurysms of the left ventricle in order to establish the risk of surgical repair. METHODS: Ten patients operated upon for a left ventricular pseudoaneurysm in our clinic between 1984 and 1999 were reviewed. The pseudoaneurysm, a complication of myocardial infarction (four acute and three chronic) or previous cardiac surgery (three chronic), was resected in all patients and the ventricular wall defect closed with direct sutures (five cases) or a patch (five cases). Coronary artery bypass graft was performed in 6 patients. RESULTS: Three patients died (postoperative mortality 30%) after repair of an acute postinfarction (2 patients) or a chronic postsurgical (1 patient) pseudoaneurysm. Three patients died during follow-up (median 4 years) of a carcinological (2 patients) or cardiac (1 patient) cause. Two years after repair, 5 patients were in New York Heart Association class I or II, and 1 patient was in class III. CONCLUSIONS: Repair of left ventricular pseudoaneurysms can be performed with acceptable results, although mortality is significant in acute myocardial infarction and redo operations. Propensity for fatal rupture, however, is higher than the surgical risk in acute pseudoaneurysms or in large or expanding chronic ones and warrants surgical repair. The best approach to small asymptomatic chronic pseudoaneurysm is unsettled.

Aged↗

In vitro validation of volumetric blood flow measurement using Doppler flow wire.

Determination of any volumetric blood flow requires assessment of mean blood flow velocity and vessel cross-sectional area. For evaluation of coronary blood flow and flow reserve, however, assessment of average peak velocity alone is widely used, but changes in velocity profile and vessel area are not taken into account. We studied the feasibility of a new method for calculation of volumetric blood flow by Doppler power using a Doppler flow wire. An in vitro model with serially connected silicone tubes of known lumen diameters (1.5, 2.0, 2.5, 3.0, 3.5 and 4.0 mm) and pulsatile blood flow ranging from 10 to 200 mL/min was used. A Doppler flow wire was connected to a commercially available Doppler system (FloMap(R), Cardiometrics) for online calculation of the zeroth (M(0)) and the first (M(1)) Doppler moment, as well as mean flow velocity (V(m)). Two different groups of sample volumes (at different gate depths) were used: 1. two proximal sample volumes lying completely within the vessel were required to evaluate the effect of scattering and attenuation on Doppler power, and 2. distal sample volumes intersecting completely the vessel lumen to assess the vessel cross-sectional area. Area (using M(0)) and V(m) (using M(1)/M(0)) obtained from the distal gates were corrected for scattering and attenuation by the data obtained from the proximal gates, allowing calculation of absolute volumetric flow. These results were compared to the respective time collected flow. Correlation between time collected and Doppler-derived flow measurements was 0.98 (p < 0.0001), with a regression line close to the line of equality indicating an excellent agreement of the two measurements in each individual tube. The mean paired flow difference between the two techniques was 1.5 +/- 9.0 mL/min (ns). Direct volumetric blood flow measurement from received Doppler power using a Doppler flow wire system is feasible. This technique may potentially be of great clinical value because it allows an accurate assessment of coronary flow and flow reserve with a commercially available flow wire system.

Blood Flow Velocity↗

Long-term follow-up of 34 adults with isolated left ventricular noncompaction: a distinct cardiomyopathy with poor prognosis.

OBJECTIVES: We sought to describe characteristics and outcome in adults with isolated ventricular noncompaction (IVNC). BACKGROUND: Isolated ventricular noncompaction is an unclassified cardiomyopathy due to intrauterine arrest of compaction of the loose interwoven meshwork. Knowledge regarding diagnosis, morbidity and prognosis is limited. METHODS: Echocardiographic criteria for IVNC include-in the absence of significant heart lesions-segmental thickening of the left ventricular myocardial wall consisting of two layers: a thin, compacted epicardial and an extremely thickened endocardial layer with prominent trabeculations and deep recesses. Thirty-four adults (age >16 years, 25 men) fulfilled the diagnostic criteria and were followed prospectively. RESULTS: At diagnosis, mean age was 42 + 17 years, and 12 patients (35%) were in New York Heart Association class III/IV. Left ventricular end-diastolic diameter was 65 + 12 mm and ejection fraction 33 + 13%. Apex and/or midventricular segments of both the inferior and lateral wall were involved in >80% of patients. Follow-up was 44 + 40 months. Major complications were heart failure in 18 patients (53%), thromboembolic events in 8 patients (24%) and ventricular tachycardias in 14 patients (41%). There were 12 deaths: sudden in six, end-stage heart failure in four and other causes in two patients. Four patients underwent heart transplantation. Automated cardioverter/defibrillators were implanted in four patients. CONCLUSIONS: Diagnosis of IVNC by echocardiography using strict criteria is feasible. Its mortality and morbidity are high, including heart failure, thrombo-embolic events and ventricular arrhythmias. Risk stratification includes heart failure therapy, oral anticoagulation, heart transplantation and implantation of an automated defibrillator/cardioverter. As IVNC is a distinct entity, its classification as a specific cardiomyopathy seems to be more appropriate.

Adolescent↗

Paravalvular leakage after mitral valve replacement: improved long-term survival with aggressive surgery?

BACKGROUND: Following mitral valve replacement, surgical closure of paravalvular leaks is usually advised in severely symptomatic patients and in those requiring blood transfusions for persisting haemolysis. However, the long-term prognosis of less symptomatic patients or those not needing blood transfusions is unknown. METHODS: Between 1987 and 1997, we observed 96 patients with mitral paravalvular leakage. A paraprosthetic leak was diagnosed after a median time of 119 days (range: 1 day-23 years) after primary mitral valve replacement. During an average follow-up of 5 years (range: 1-23 years), 50/96 patients were referred for surgical closure. RESULTS: Compared with patients who received conservative treatment, those referred for surgery had a significantly lower mean preoperative haematocrit (P = 0.002) with a higher proportion of patients being in the NYHA class III/IV (P = 0.03). Age, gender, left ventricular function and number and size of leaks did not differ between the groups. The 30-day postoperative mortality for valve reoperation was 6% (3/50); during follow-up three further patients died, resulting in an overall mortality rate of 12%. In the group treated conservatively there was a mortality rate of 26% (12/46). Thus, the actuarial survival for patients referred for surgery was 98, 90 and 88% after 1, 5 and 10 years, compared with 90, 75 and 68% for patients treated conservatively (long-rank P = 0.03). In addition, there was a significant increase in mean haematocrit levels (P = 0.0001) and an improvement in NYHA class III/IV symptoms (P = 0.002), vertigo (P = 0.001) and fatigue (P = 0.001) after surgery. CONCLUSIONS: Following mitral valve replacement, a more aggressive surgical treatment is recommended for patients with paraprosthetic leaks. Surgery should be offered to less symptomatic patients, as well as those not requiring blood transfusion.

Adult↗

Doppler mirror image artifacts mimicking mitral regurgitation in patients with mechanical bileaflet mitral valve prostheses.

AIMS: To characterize the origin and mechanisms of generation of Doppler mirror images in the left atrium observed in patients with mechanical bileaflet mitral valve prosthesis. We hypothesized that these systolic colour Doppler images are artifactual and generated by reflection of the left ventricular outflow tract flow at the leaflet of the mitral valve prosthesis. METHODS AND RESULTS: Fifty patients with mechanical bileaflet mitral valves were prospectively examined by means of transthoracic Doppler-echocardiography. From different apical views, the left atrium was carefully interrogated for systolic colour flow signals, which were further analysed by pulsed wave Doppler. In all patients, a systolic colour Doppler signal was detected in the left atrium. Pulsed wave Doppler analysis revealed a low velocity signal (= mirror image) corresponding to the shape and duration of the left ventricular outflow tract signal. The peak velocities of these mirror images, however, were consistently lower than the velocities obtained from the left ventricular outflow tract. In addition, if paravalvular mitral valve leakage was present, a high velocity signal identical to the duration of mitral regurgitation time was detected outside the ring of the prosthesis. CONCLUSIONS: Mirror image artifacts mimicking mitral regurgitation occur in patients with mechanical mitral valves prosthesis. As mirror image artifacts can be specifically identified by analysis of shape. velocity, and duration of pulsed wave Doppler spectra, their identification will help to avoid misinterpretation of both spectral and colour Doppler signals in patients with prosthetic mitral valves.

Aged↗

Ebstein's anomaly in adults: Doppler-echocardiographic evaluation.

A systematic approach and segmental analysis are required for comprehensive assessment including both morphologic and functional abnormalities associated with Ebstein's anomaly. The essence of the disease is an apical displacement of both the septal and the posterior tricuspid leaflets, exceeding 20 mm or 8 mm/m2 in adults. As a consequence, the right heart consists of three components including the true right atrium, the functional right ventricle (RV) and an intervening zone that is anatomically ventricular but functionally right atrial (atrialized RV). The thin wall of the atrialized RV may result in an aneurysm between the anatomic tricuspid annulus and the apically displaced posterior leaflet. The annular attachment of the anterior leaflet is normal, which may be dysplastic and adherent to the RV wall. Tricuspid regurgitation is usually moderate to severe. Size, shape and function of the functional RV must be described. The paradoxical motion of the interventricular septum causes alterations in left ventricular geometry and function. An interatrial communication is frequently present. Echocardiography is the method of choice to diagnose Ebstein's anomaly on its own or in association with other heart defects.

Adult↗

40 years after the first atrial switch procedure in patients with transposition of the great arteries: long-term results in Toronto and Zurich.

The atrial switch procedure dramatically improved the prognosis of children with complete transposition of the great arteries (TGA). Overall actuarial survival was approximately 75% after 25 years and was better in patients with simple TGA than in those with complex TGA. Mortality by any cause (16%) and cardiovascular mortality (12% and 13%) were comparable in both centers. Progressive congestive heart failure and sudden death were the principal modes of death. Most of the survivors denied any symptoms or had mild limitations in their daily activities. However, long-term problems in this growing population of adults are challenging and include late arrhythmias (up to two thirds of the patients), systemic ventricular (SV) failure, systemic atrioventricular valve regurgitation and reoperations, such as baffle reconstruction, being the most frequent. Objective assessment of SV function obtained by echocardiography is difficult. It may include fractional area change and tricuspid annular motion. Survivors after an atrial switch procedure are unique and have a good quality of life. However, the definitive and true history of the RV supporting the systemic circulation is not as yet known.

Activities of Daily Living↗

Left ventricular end-diastolic pressure can be estimated by either changes in transmitral inflow pattern during valsalva maneuver or analysis of pulmonary venous flow.

We directly compared the transmitral inflow pattern during preload reduction and pulmonary venous flow velocities to determine left ventricular end-diastolic pressure (LVEDP) in 78 patients who underwent left heart catheterization. Transmitral inflow indexes (A-wave duration, ratio of peak flow velocity of early diastole [E] to peak flow velocity of late diastole during atrial contraction [A] [E/A ratio]) at rest and during the Valsalva maneuver (30 mm Hg for 15 seconds) and indexes of pulmonary venous flow (velocity and duration of the atrial reversal) were obtained. Fair correlations existed between LVEDP (mean 15+/-6 mm Hg) and the percentage decrease in the E/A ratio (r = 0.72), increase in duration of A wave during the Valsalva maneuver (r = 0.60), flow velocity of atrial reversal (r = 0.58), and difference of duration of atrial flow reversal and A wave (r = 0.62) (all P<.001). While sensitivity, specificity, and diagnostic accuracy to detect an elevated LVEDP were comparable, technically adequate Doppler recordings were obtained more often for the mitral inflow during the Valsalva maneuver than for the pulmonary venous flow (72 versus 66 patients, P< 0.05).

Aged↗

Left ventricular pressure-area relations as assessed by transoesophageal echocardiographic automated border detection: comparison with conductance catheter technique in cardiac surgical patients.

The aim of this study was to validate measurements of intraoperative left ventricular (LV) area by transoesophageal echocardiography against simultaneous measurements of LV volume by conductance catheter (CC) in cardiac surgical patients with normal systolic LV function. Echo area was compared with CC volume during steady state and during acute changes of pre- and afterload by partial clamping of the inferior vena cava and the ascending aorta in eight patients scheduled for coronary artery bypass grafting. At steady state, Bland-Altman analysis of 32 recordings revealed a bias (SD) of 0.6% (2.5%) between echo area and CC volume, related to the initial values of end-diastolic area (100% area) and volume (100% volume), respectively. During loading interventions, bias between the two methods, as assessed by 112 measurement sequences, was 0.5% (3.7%) during aortic occlusion and -3.9% (4.4%) during cava occlusion at end-systole (P < 0.0001); at end-diastole, this bias was 1.3% (4%) during aortic occlusion and 0.2% (5.7%) during cava occlusion (P < 0.0001). Intraoperative area measurements with transoesophageal echocardiography in cardiac surgical patients with normal systolic LV function show good correlation with CC volume measurements under steady-state conditions. During acute unloading by vena cava occlusion, the resulting small end-systolic echo area measurements differ significantly more from CC volume measurements than during acute increase in afterload by aortic occlusion.

Anesthesia↗

Enhanced left ventricular endocardial border delineation with an intravenous injection of SonoVue, a new echocardiographic contrast agent: A European multicenter study.

The safety and efficacy of SonoVue (also referred to as BR1), a new contrast agent for delineating endocardial border of the left ventricle after intravenous administration, was assessed. Two hundred and eighteen patients with suspected coronary artery disease undergoing fundamental echocardiography for the assessment of left ventricle were enrolled in a prospective multicenter, single blind, cross-over study with random sequence allocation of four different doses of SonoVue. Endocardial border definition in the apical and parasternal views was scored as 0 = not visible, 1 = barely visible, and 2 = well visualized before and after contrast enhancement. Analysis was performed by two pairs of off-site observers. Safety of SonoVue was also assessed. Results of our study indicated that the mean improvements in the endocardial border visualization score were as follows: 3.1 +/- 7.8 (95% CI, 2.5 and 3.7) for 0.5 ml, 3.4 +/- 8.0 (95% CI, 2.8 and 4.0) for 1 ml, 3.4 +/- 7.9 (95% CI, 2.8 and 4.0) for 2 ml, and 3.7 +/- 8.0 (95% CI, 3.1 and 4.3) for 4 ml (P < 0.05 for all doses from baseline). Changes from baseline in endocardial visualization scores were also seen in the apical views (P < 0.05) and they were dose-dependent (P < 0.001). Similar enhancements of endocardial visualization scores were observed in the apical views in patients with suboptimal baseline echocardiographic images. Diagnostic confidence for assigning a score and image quality also were significantly better following contrast enhancement. No significant changes in the laboratory parameters and vital signs were noted following contrast enhancement, and the side effects were minimal. It was concluded that SonoVue is safe and effective in delineating endocardial border, including in patients with suboptimal baseline images.

Aged↗

Extensive thrombus formation in the right ventricle due to a rare combination of arrhythmogenic right ventricular cardiomyopathy and heterozygous prothrombin gene mutation G20210 A.

Arrhythmogenic right ventricular cardiomyopathy is a rare heart muscle disease characterized by right and often left ventricular myocardial atrophy and fibrofatty replacement. Heart failure, arrhythmias and sudden death are characteristic complications. We observed a female in whom arrhythmogenic right ventricular cardiomyopathy was diagnosed due to presyncopes and dyspnea on exertion. A left ventricular thrombus was found echocardiographically, which disappeared with oral anticoagulation. Subsequently, however, extensive thrombus formation in the dilated akinetic right ventricle occurred which was resistant to combined treatment with heparin and oral anticoagulation. Thrombophilia screening showed a mutant prothrombin 20210A allele which is an inherited coagulopathy associated with increased plasma levels of prothrombin and increased risks of mainly venous thrombosis. The patient developed endstage biventricular heart failure and underwent heart transplantation within 3 months after thrombus formation in the right ventricle was diagnosed. In the explanted heart, the thrombus in the right ventricle was impressively large and calcified. In patients with unusual thrombus formation in the heart, coagulopathy may be associated and should be excluded.

Adult↗

Resolution of protein-losing enteropathy with standard high molecular heparin and urokinase after Fontan repair in a patient with tricuspid atresia.

At 6 years of age, a girl with tricuspid atresia underwent a Björk modified Fontan procedure with implantation of a Carpentier Edwards bioprosthesis between the right atrium and the right ventricle. Ten years later she developed increasing edema, ascites and pleural effusions. The work-up showed severe stenosis of the bioprosthesis and protein losing enteropathy with a massive decrease of the albumin level to 14 g/l (normal 40-50 g/l). At 17 years of age, the bioprosthesis was replaced with a direct anastomosis between the cavoatrial junction and the right pulmonary artery. Within one month post-operatively, extensive thrombosis of the superior vena cava, anonymous and subclavian veins occurred. Protein-losing enteropathy persisted with an albumin level of 17 g/l. Parallel to the successful treatment of these thrombi with high molecular heparin and urokinase, protein losing enteropathy and hypoalbuminemia resolved completely as long as the antithrombotic treatment with high molecular heparin was continued. Oral anticoagulation was ineffective. Chronic antithrombotic treatment with high molecular heparin may thus be the treatment of choice in these forms of protein-losing enteropathy associated with venous thrombosis.

Child↗