PubMed Health⌕ Search

Biomedical subjects

R K Tam

Publications and source records attributed to R K Tam.

11 recordsLinked to original sources

Late complications of tissue glues in aortic surgery.

BACKGROUND: Tissue glues are used in cardiothoracic surgery as an adjunct to operative procedures where tissues are frail, as in aortic dissection, or where added hemostasis is required. This study was undertaken to review the use of tissue glue in our institution over a 5.5-year period. The aim of the study was to identify any potentially glue-related complications. METHODS: A review of tissue glue use for the period from January 1993 to September 1998 was performed and pre-, intra-, and postoperative parameters were collected. After some unusual surgical findings, of special interest was a range of pathology found at late reoperation. RESULTS: A total of 67 cases of tissue glue use were identified, with the majority of operations for type A dissection (76%). There were two intraoperative deaths. Twenty-seven of 65 patients (41%) required 29 further open chest operations; of these, 17 were for acute problems of bleeding or tamponade. Twelve patients (18%) underwent late reoperations months to years later. Nine of these patients, concentrated in two operative groups (7 patients with aortic valve resuspension and 2 patients who had undergone "switch" operations for transposition of great vessels), displayed complications related to the application of gelatin-resorcinol-formaldehyde (GRF) tissue glue. CONCLUSIONS: Indications for tissue glues in cardiothoracic surgery must be carefully considered. We have reviewed our use of some tissue glues in acute type A aortic dissections and in pediatric cardiac patients and have discontinued the use of GRF glues because of unsatisfactory long-term complications.

Aortic Dissection↗

Minimally invasive aortic valve replacement via hemi-sternotomy: a preliminary report.

OBJECTIVE: Aortic valve replacement has been approached by standard sternotomy. We described a technique of aortic valve replacement where the aortic valve is exposed through a hemi-sternotomy. Good exposure is obtained for aortic valve surgery with standard aortic and right atrial cannulation to establish cardiopulmonary bypass (CPB). METHODS: From October 1996 to April 1997, 19 consecutive aortic valve replacements (AVR) via hemi-sternotomy were performed by one surgeon. The results were collected and analysed prospectively. Results are expressed as mean +/- standard deviation. Nineteen patients (13 male, 6 female) had AVR with this approach. Two cases were redo AVR. The mean age was 58+/-15 years. The New York Heart Association (NYHA) class was 2.8+/-0.7. RESULTS: Aortic cross clamp time was 54+/-13 min. One of six patients requiring defibrillation after reperfusion needed conversion to full sternotomy. Four patients were extubated at the conclusion of surgery. One patient died 4 h postoperatively from low cardiac output. All patients had normal valvular function demonstrated on postoperative transoesophageal echocardiography. There were no neurological events. CONCLUSIONS: Minimally invasive aortic valve replacement can be safely performed via hemi-sternotomy with standard equipment. Less surgical trauma to the sternum has the potential benefit of less pain and shorter intensive care and hospital stay.

Aortic Valve↗

Use of larger sized aortic homograft conduits in right ventricular outflow tract reconstruction.

Between 1973 and 1993 sixty aortic homograft valved conduits in fifty-six patients were used to establish continuity between the right ventricle and the pulmonary artery in congenital heart disease. Age range was one day to 23.5 years (median 3.6 years) which included twenty-six patients less than one-year-old. Conduit size ranged from 11 to 23 mm (median 17.6 mm). there were nine hospital deaths and eight late deaths. The 45 survivors have been followed for a median of 8.6 years (range 6 months to 20 years). All patients have had serial echocardiographic assessments and 35 have had post repair cardiac catheterization. Almost all patients had mild-to-moderate degrees of homograft regurgitation. There were eleven with severe homograft regurgitation and two are being considered for reoperation. The follow up homograft gradient ranged from 0 to 64 mmHg (mean 24 mmHg). Freedom from reoperation for conduit obstruction was 98.2% at five years falling to 91% (C.L. 82%-100%) at 10 years. Of the 23 homografts inserted more than 10 years ago, only one (4.3%) has been replaced because it was causing important obstruction. None have been replaced for regurgitation. Our results indicate that larger sized aortic homografts used in reconstruction of the right ventricular outflow tract give satisfactory results and there is a low incidence of reoperation for replacement at medium term follow up.

Aortic Valve↗