PubMed Health⌕ Search

Biomedical subjects

R Karp

Publications and source records attributed to R Karp.

At least 19 recordsLinked to original sources

Detecting protein sequence conservation via metric embeddings.

MOTIVATION: Comparing two protein databases is a fundamental task in biosequence annotation. Given two databases, one must find all pairs of proteins that align with high score under a biologically meaningful substitution score matrix, such as a BLOSUM matrix (Henikoff and Henikoff, 1992). Distance-based approaches to this problem map each peptide in the database to a point in a metric space, such that peptides aligning with higher scores are mapped to closer points. Many techniques exist to discover close pairs of points in a metric space efficiently, but the challenge in applying this work to proteomic comparison is to find a distance mapping that accurately encodes all the distinctions among residue pairs made by a proteomic score matrix. Buhler (2002) proposed one such mapping but found that it led to a relatively inefficient algorithm for protein-protein comparison. RESULTS: This work proposes a new distance mapping for peptides under the BLOSUM matrices that permits more efficient similarity search. We first propose a new distance function on peptides derived from a given score matrix. We then show how to map peptides to bit vectors such that the distance between any two peptides is closely approximated by the Hamming distance (i.e. number of mismatches) between their corresponding bit vectors. We combine these two results with the LSH-ALL-PAIRS-SIM algorithm of Buhler (2002) to produce an improved distance-based algorithm for proteomic comparison. An initial implementation of the improved algorithm exhibits sensitivity within 5% of that of the original LSH-ALL-PAIRS-SIM, while running up to eight times faster.

Algorithms↗

A mini-fellowship in clinical nutrition for primary care physicians.

When the Regional Nutrition Center's (RNC's) mini-fellowship was being developed, physicians teaching in medical schools and residency programs had little formal training in nutrition, so it was difficult to identify faculty to serve as role models and clinical preceptors. Using funds provided by an NIH/NCI R-25 grant, the mini-fellowship in clinical nutrition was developed as a model to meet the nutrition education needs of senior residents and junior faculty in primary care disciplines. It provided a brief but broad exposure to clinical nutrition topics, with a focus on issues relevant to the practice of primary care and teaching skills. In four weeks, fellows completed didactic course work, a clinical preceptorship, and a teaching project. Tracking of the 55 physicians who completed the program by questionnaires has shown significant improvement in their nutrition-related patient care activities.

Fellowships and Scholarships↗

Universal DNA tag systems: a combinatorial design scheme.

Custom-designed DNA arrays offer the possibility of simultaneously monitoring thousands of hybridization reactions. These arrays show great potential for many medical and scientific applications, such as polymorphism analysis and genotyping. Relatively high costs are associated with the need to specifically design and synthesize problem-specific arrays. Recently, an alternative approach was suggested that utilizes fixed, universal arrays. This approach presents an interesting design problem-the arrays should contain as many probes as possible, while minimizing experimental errors caused by cross-hybridization. We use a simple thermodynamic model to cast this design problem in a formal mathematical framework. Employing new combinatorial ideas, we derive an efficient construction for the design problem and prove that our construction is near-optimal.

Base Sequence↗

Cor triatriatum in a 70-year-old woman: role of transesophageal echocardiography and dynamic three-dimensional echocardiography in diagnostic assessment.

In this report we describe a 70-year-old woman with unrecognized nonobstructive cor triatriatum (CT). She had concomitant mitral regurgitation and coronary artery disease. Diagnosis of CT and its hemodynamic assessment were accomplished by transesophageal echocardiography. Dynamic three-dimensional echocardiography demonstrated multiple fenestrations in the left atrial membrane. Intraoperative findings confirmed the diagnostic accuracy of three-dimensional echocardiography. To our knowledge, this is the first case of CT that has anatomic correlation with three-dimensional echocardiography.

Aged↗

Identifying the cause of left ventricular systolic dysfunction after coronary artery bypass surgery: the role of myocardial contrast echocardiography.

OBJECTIVE: Intraoperative myocardial contrast echocardiography was used to determine whether the identification of regional myocardial flow patterns during revascularization could predict myocardial contractile function immediately after separation from cardiopulmonary bypass (CPB) and at 1 month after coronary artery bypass grafting (CABG) surgery. DESIGN: A prospective, open-labeled, longitudinal analysis. SETTING: Two independent university hospitals. PARTICIPANTS: Twenty patients, during and up to 1 month after CABG. INTERVENTIONS: The contrast agent Albunex (Mallenckrodt Medical, Inc, St Louis, MO) was injected into the aortic root during CPB. MEASUREMENTS AND MAIN RESULTS: Myocardial contrast echocardiography opacification of flow was graded from intraoperative transesophageal echocardiographic images of the left ventricle in the short-axis, midpapillary view. The same myocardial images were also evaluated for regional wall motion abnormalities at 15, 30, and 60 minutes, 24 hours, 5 to 8 days, and 1 month after CPB. Logistic regression analysis was used to analyze the flow scores and regional function data from identical segments. Regional flow represented by contrast enhancement was assessed in 70% of the myocardial regions (55 of 80 possible segments; 95% confidence interval [CI], 61 to 76). Flow was more easily evaluated in the posterior region (95%) than in the anterior (70%) or septal regions (60%), and least likely evaluated in the lateral regions (50%). Regional wall motion was scored in 84% of the myocardial regions (469 of 560 possible regions). Function (segmental wall motion) was assessed in all regions with equal success. Segmental function and flow scores were matched to the same regions 66% of the time (53 of 80 possible series; 95% CI, 55 to 76). Regional myocardial contrast flow patterns did not predict myocardial function at 15, 30, or 60 minutes after separation from CPB. However, contrast opacification of flow did predict regional myocardial function at 1 week (p < or = 0.05) and at 1 month (p < or = 0.01) after CABG surgery. The probability that myocardial function would be normal at 1 month was 0.62 when intraoperative flow opacification was abnormal and 0.98 when flow opacification was normal. For patients with normal flow, the estimated odds of having normal myocardial function were 3.33 times those of patients with abnormal flow at 1 week (odds ratio, 3.33; 95% CI, 1.09 to 10.19) and 18.5 times those of patients with abnormal flow at 1 month (95% CI, 2.44 to 140.48). CONCLUSION: Intraoperative application of myocardial contrast echocardiography to determine regional flow patterns after revascularization may help differentiate conditions of left ventricular systolic dysfunction immediately after separation from CPB for CABG surgery and appear to predict myocardial function at 1 month.

Adult↗

Feasibility of aortic diameter measurement by multiplane transesophageal echocardiography for preoperative selection and preparation of homograft aortic valves.

BACKGROUND: Preoperative knowledge of the aortic annular diameter could enable the preoperative selection and preparation of an appropriately sized homograft aortic valve. OBJECTIVE: The aims of this study were to prospectively determine whether the combined use of transthoracic and multiplane transesophageal echocardiography allows accurate preoperative aortic annular measurements for the selection and preparation of adequately sized homograft aortic valves and to retrospectively evaluate the influence of the echocardiographic approach (transthoracic vs transesophageal) and the reader's level of experience on the accuracy of these measurements. METHODS: Aortic annular measurements were performed before the operation by an experienced reader who used a combination of transthoracic and multiplane transesophageal images of 25 patients (mean age 52 +/- 13 years) referred for homograft aortic valve replacement. Measurements were also performed retrospectively by three additional readers with different levels of training in echocardiography. These readers acquired aortic annular diameters from prerecorded tapes and obtained measurements from each echocardiographic modality independently. All values were compared with the surgical measurement obtained with a ring valve sizer. RESULTS: With the combined echocardiographic approach, excellent agreement was found between preoperative echocardiographic and surgical measurements (mean difference +/- 2 standard deviations = 0.2 +/- 1.4 mm). All echocardiographic data were found to be within 2 mm of the surgical measurement. These measurements were used to select and prepare the aortic homograft valve before insertion. The accuracy of annular measurements appeared to increase in parallel to the level of experience. The aortic annular measurements obtained retrospectively by a second experienced reader were more accurate with the use of transesophageal than with transthoracic echocardiography (p < 0.01). In contrast, the echocardiographic modality had no influence on the accuracy of measurements of less experienced readers (p > 0.2). CONCLUSIONS: Preoperative measurement of the aortic annular diameter by transthoracic and multiplane transesophageal echocardiography is accurate and clinically feasible. Preoperative knowledge of the aortic annular diameter may be used to select and prepare the aortic homograft, improving valve availability and reducing ischemic time.

Adult↗

Randomized comparison trial of teicoplanin i.v., teicoplanin i.m., and cefazolin therapy for skin and soft tissue infections caused by gram-positive bacteria.

Teicoplanin, a glycopeptide antibiotic chemically related to the vancomycin-ristocetin group of antibiotics, has potent activity against aerobic and anaerobic gram-positive bacteria. In this study, we examined the efficacy and safety of teicoplanin for parenteral treatment of skin and soft tissue infections caused by gram-positive bacteria. Ninety-six hospitalized adults with moderate to severe skin and soft tissue infections were randomized to receive either teicoplanin intravenously (i.v.) once a day, teicoplanin intramuscularly (i.m.) once a day, or cefazolin i.v. every 8 hours. We evaluated patients' clinical and microbiologic status and assessed clinical and laboratory adverse events. Of 76 clinically assessable patients, 26 of 26 (100%) given teicoplanin i.v., 21 of 22 (95%) given teicoplanin i.m., and 26 of 28 (93%) given cefazolin showed improvement or cure. Of 60 microbiologically assessable patients, 22 of 22 (100%) given teicoplanin i.v., 16 of 18 (89%) given teicoplanin i.m, and 18 of 20 (90%) given cefazolin were cured. Of 96 patients assessable for adverse events, 7 of 34 (21%) given teicoplanin i.v., 4 of 31 (13%) give teicoplanin i.m., and 1 of 31 (3%) given cefazolin had adverse events. In this study, once daily teicoplanin appeared to be safe and effective therapy for skin and soft tissue infections.

Cefazolin↗

Candida albicans purulent pericarditis treated successfully without surgical drainage.

Cures of Candida pericarditis reported in the literature uniformly involved surgical drainage of the pericardial space. We report a patient with purulent pericarditis caused by Candida albicans who was treated successfully with antifungal chemotherapy combined with a single pericardiocentesis that did not completely evacuate the pericardial space. This case indicates that thoracotomy with surgical drainage of the pericardium is not mandatory for successful therapy of Candida pericarditis.

Amphotericin B↗

The conduction system in truncus arteriosus and its surgical significance. A study of five cases.

Atrioventricular block may occasionally occur after surgical correction of truncus arteriosus. We therefore studied the conduction system by means of serial sections in five cases of truncus (one after surgical intervention) to delineate the course of the conduction system and its relationship to the ventricular septal defect and the membranous septum. In general, the ventricular septal defect is in the anterior septum, confluent with the truncus, and the atrioventricular bundle is posterior and unrelated to the rim of the ventricular septal defect. In cases in which the ventricular septal defect is anterior and separated from the membranous septum by distinct muscle, the ventricular septal defect can be surgically closed without injury to the atrioventricular bundle. If the ventricular septal defect is related to the membranous septum, the atrioventricular bundle may be close to the ventricular septal defect and susceptible to surgical injury. If muscle separates the ventricular septal defect from the membranous septum, the branching bundle is close to the ventricular septal defect and also is susceptible to surgical injury. In one operated case there was partial dissolution of the left bundle branch, and the right bundle branch was involved in surgical closure of the defect. In summary, in truncus the conduction system varies in its course and is related to the location of the ventricular septal defect and its relationship to the membranous septum. The ventricular septal defect may be close to or related to the membranous septum, and the atrioventricular bundle and the beginning of the bundle branches may be vulnerable to surgical injury.

Atrioventricular Node↗

A randomized trial of cefepime (BMY-28142) and ceftazidime for the treatment of pneumonia.

Cefepime is a new cephalosporin with a broad antimicrobial spectrum that includes Staphylococcus aureus and Pseudomonas aeruginosa. To study the efficacy and safety of cefepime for treatment of pneumonia, 65 patients were randomized to therapy with either cefepime or ceftazidime at a two to one ratio. Of the 57 evaluable patients, 89% of the cefepime patients and 84% of the ceftazidime patients were cured clinically or improved. Haemophilus spp., Streptococcus pneumoniae, and Neisseria spp. were common pathogens. Bacteriological cure was achieved in 31 (91%) of cefepime patients and 17 (100%) ceftazidime patients. Adverse clinical and laboratory reactions possibly due to study drug occurred in 9 (21%) cefepime patients and in 1 (5%) ceftazidime patient. Most reactions were mild and resolved with discontinuation of study drug. In this study, cefepime appeared as effective as ceftazidime for the treatment of pneumonia.

Adult↗

Ceftibuten versus cefaclor for the treatment of bronchitis.

Ceftibuten is an oral third generation cephalosporin with potent antimicrobial activity against Enterobacteriaceae, beta-lactamase positive Haemophilus influenzae, Moraxella catarrhalis, Neisseria meningitidis, Neisseria gonorrheae, penicillin-susceptible pneumococci, and beta-hemolytic streptococci. To study the efficacy and safety of ceftibuten for treatment of bronchitis, 58 patients were randomized to therapy with either ceftibuten 400 mg once a day or cefaclor 250 mg every 8 h at a ratio of two to one. Of 45 clinically evaluable patients, 28 (87.5%) of the 32 ceftibuten patients and 12 (92.3%) of the 13 cefaclor patients were clinically improved or cured. Of 33 microbiologically evaluable patients, 21 (87.5%) of the 24 ceftibuten patients and eight (80%) of the ten cefaclor patients were cured. Of 56 patients evaluable for adverse effects, three (7.9%) of the 38 ceftibuten patients and one (5.6%) of the 18 cefaclor patients had adverse reactions. In this small study, once-daily ceftibuten appeared as safe and as effective as cefaclor for the treatment of bronchitis.

Bacteria↗

The overlooked, retained Double J stent.

A series of 4 patients with long overlooked, retained ureteral stents is presented to illustrate the variable, unpredictable, and at times, hazardous course of such patients. These cases are cited to re-emphasize the need for careful documentation, observation, and follow-up of patients in whom stents are placed.

Adolescent↗