PubMed Health⌕ Search

Biomedical subjects

R Kevin Blackburn

Publications and source records attributed to R Kevin Blackburn.

3 recordsLinked to original sources

Substrate specificity and novel selective inhibitors of TNF-alpha converting enzyme (TACE) from two-dimensional substrate mapping.

We report a systematic analysis of the P1' and P2' substrate specificity of TNF-alpha converting enzyme (TACE) using a peptide library and a novel analytical method, and we use the substrate specificity information to design novel reverse hydroxamate inhibitors. Initial truncation studies, using the amino acid sequence around the cleavage site in precursor-TNF-alpha, showed that good turnover was obtained with the peptide DNP-LAQAVRSS-NH2. Based on this result, 1000 different peptide substrates of the form Biotin-LAQA-P1'-P2'-SSK(DNP)-NH2 were prepared, with 50 different natural and unnatural amino acids at P1' in combination with 20 different amino acids at P2'. The peptides were pooled, treated with purified microsomal TACE, and the reaction mixtures were passed over a streptavidin affinity column to remove unreacted substrate and the N-terminal biotinylated product. C-terminal cleavage products not binding to streptavidin were subjected to liquid chromatography/mass spectrometry analysis where individual products were identified and semiquantitated. 25 of the substrates were resynthesized as discrete peptides and assayed with recombinant TACE. The experiments show that recombinant TACE prefers lipophilic amino acids at the P1' position, such as phenylglycine, homophenylalanine, leucine and valine. At the P2' position, TACE can accommodate basic amino acids, such as arginine and lysine, as well as certain non-basic amino acids such as citrulline, methionine sulfoxide and threonine. These substrate preferences were used in the design of novel reverse hydroxamate TACE inhibitors with phenethyl and 5-methyl-thiophene-methyl side-chains at P1', and threonine and nitro-arginine at P2'.

ADAM Proteins↗

Exploiting the complementary nature of LC/MALDI/MS/MS and LC/ESI/MS/MS for increased proteome coverage.

The goal of this work was to evaluate the improvement in proteome coverage of complex protein mixtures gained by analyzing samples using both LC/ESI/MS/MS and LC/MALDI/MS/MS. Parallel analyses of a single sample were accomplished by interfacing a Probot fractionation system with a nanoscale LC system. The Probot was configured to perform a post-column split such that a fraction (20%) of the column effluent was sent for on-line LC/ESI/MS/MS data acquisition, and the majority of the sample (80%) was mixed with a matrix solution and deposited onto the MALDI target plate. The split-flow approach takes advantage of the concentration sensitive nature of ESI and provides sufficient quantity of sample for MALDI/MS/MS. Hybrid quadrupole time-of-flight mass spectrometers were used to acquire LC/ESI/MS/MS data and LC/MALDI/MS/MS data from a tryptic digest of a preparation of mammalian mitochondrial ribosomes. The mass spectrometers were configured to operate in a data dependent acquisition mode in which precursor ions observed in MS survey scans are automatically selected for interrogation by MS/MS. This type of acquisition scheme maximizes the number of peptide fragmentation spectra obtained and is commonly referred to as shotgun analysis. While a significant degree of overlap (63%) was observed between the proteins identified in the LC/ESI/MS/MS and LC/MALDI/MS/MS data sets, both unique peptides and unique proteins were observed by each method. These results demonstrate that improved proteome coverage can be obtained using a combination of these ionization techniques.

Animals↗

A novel interface for variable flow nanoscale LC/MS/MS for improved proteome coverage.

A variable flow "peak trapping" liquid chromatography (LC) interface has been developed for the coupling of nanoscale LC to electrospray ionization mass spectrometry (ESI-MS). The presented peak trapping LC interface allows for the extended analysis time of co-eluting compounds and has been employed for the identification of proteins via tandem mass spectrometry (MS/MS). The variable flow process can be controlled either manually or in a completely automated manner where the mass spectrometer status determines the status of the variable flow interface. When the mass spectrometer operates in MS survey mode, the interface is operated in a so-called "high-flow" mode. Alternatively, the interface is operated in a "low-flow" mode during MS/MS analysis. In the "high-flow" mode of the variable flow process the column flow rate is typically around 200 nL/min, whereas in the "low-flow" mode the column effluent is introduced into the source of the mass spectrometer at 25 nL/min. In addition to the flow reduction during MS/MS analysis, the gradient is paused to preserve the peptide separation on the analytical nanoscale LC column. The performance of the variable flow nanoscale LC/MS/MS interface is demonstrated by the automated analysis of standard peptide mixtures and protein digests utilizing variable flow, data-dependent scanning MS/MS techniques, and automated database searching.

Animals↗