PubMed Health⌕ Search

Biomedical subjects

R Kharbanda

Publications and source records attributed to R Kharbanda.

11 recordsLinked to original sources

Is the MIC useful in deciding to treat endocarditis surgically?

The infecting pathogen and its susceptibility to antibiotics is used to suggest prognosis in endocarditis. A case study was performed in a tertiary referral cardiology centre to assess the contribution of the measurement of minimum inhibitory concentration (MIC) to the decision to treat endocarditis surgically. The records were examined of 125 patients admitted between 1981 and 1999 in whom the minimum inhibitory concentration for the pathogen had been measured. The measures of outcome were mortality at time of hospital discharge and at 6 months, surgical referral and cure by medical treatment. Endocarditis caused by Staphylococcus aureus with a raised MIC of flucloxacillin (methicillin) was associated with higher mortality even if glycopeptides were used in treatment (< or = 35 mg/l 0/7 versus MIC 1-2 mg/l 4/13, P = 0.01). Elevated MICs of flucloxacillin in S. aureus infection or of gentamicin in streptococcal disease were associated with surgical intervention. There were no significant differences between bacterial pathogens in mortality, surgical referral or cure by medical treatment. The measurement of MIC appears prognostically important in deciding the surgical management of endocarditis.

Anti-Bacterial Agents↗

Acute administration of L-arginine does not improve arterial endothelial function in chronic renal failure.

BACKGROUND: Reduced activity of the nitric oxide (NO) pathway has been implicated in the endothelial dysfunction that occurs in patients with renal failure. NO is generated from L-arginine by NO synthase, and certain uremic toxins including asymmetrical dimethyl-L-arginine (ADMA), inhibit NO synthase and might contribute to endothelial dysfunction. We hypothesized that exogenous L-arginine might improve endothelial function in patients with renal failure by overcoming the effects of uremic toxins. METHODS: Endothelial function of the forearm resistance vasculature was assessed using plethysmography to measure the dilator response to intra-arterial acetylcholine (25 to 100 nmol/min). Endothelial function of radial and brachial arteries was assessed using vascular ultrasound to measure the dilator response to flow during reactive hyperemia (flow-mediated dilation; FMD). Studies were performed before and after administration of L-arginine by intra-arterial infusion (50 micromol/min) in 8 pre-dialysis patients or by intravenous infusion (10 g) in 18 hemodialysis patients. RESULTS: Local L-arginine did not improve the dilator response of forearm resistance vessels (AUC 23.1 +/- 6.4 pre, 23.1 +/- 5.1 post; P = 0.9) or FMD of the radial artery (6.5 +/- 1.2% pre, 6.3 +/- 0.8% post; P = 0.8). Systemic L-arginine did not improve FMD of the brachial artery (4.1 +/- 1.1% pre, 3.0 +/- 1.1% post; P = 0.07). These data demonstrate that acute local or systemic administration of L-arginine did not improve endothelial function in resistance or conduit arteries of patients with chronic renal failure. CONCLUSION: The results suggest that competitive inhibition of nitric oxide synthase (NOS) by circulating inhibitors is not the principal explanation for impaired endothelial dilator function in chronic renal failure.

Adult↗

Nucleophilic scission of thioester linkages and conformational changes in human plasma low density lipoproteins.

A comparison between conformations of native and methylamine modified human plasma low density lipoproteins (hydrated density 1.032-1.043 g/ml) has been presented. Near UV circular dichroism and difference absorption spectra of modified low density lipoprotein have suggested substantial differences in the local environments of several aromatic amino acid side chains. Relatively lower ellipticity at 222 nm of modified lipoprotein indicated alterations in the secondary structures of its protein moiety. Nucleophilic reaction of methylamine did not cause the peptide bond scission but it brought conformational transition such that some of the buried hydrophobic domains of the protein moiety got exposed to the aqueous environment.

Apolipoproteins B↗

Heterogeneity of glutathione S-transferase isoenzyme expression in renal disease.

Recent work has suggested that glutathione S-transferase (GST) enzymuria may be used to assess renal injury in transplant kidneys. There is little work investigating the possibility of using glutathione S-transferase enzymuria to assess other renal diseases and this study was undertaken to evaluate the localisation of GST isoenzymes in various glomerular and tubular pathologies so that the specificity of these enzymes as markers of tubular injury could be defined. Immunostaining was carried out to establish the location of alpha and pi class GST in renal biopsies from patients with a wide variety of renal diseases including membranous glomerulonephritis, minimal-lesion glomerulonephritis, mesangial proliferative glomerulonephritis, loin pain haematuria syndrome, and renal allograft rejection. In the cases of glomerulonephritis studied, alpha class GST was detected in proximal tubules and pi class GST in distal convoluted tubules, podocytes, and Bowman's capsule. The majority of cases of glomerulonephritis showed a heterogeneous pattern of expression of both isoenzymes: that is, there was variation in intensity of staining both in single tubules and also between tubules as opposed to the uniform staining pattern observed in normal kidneys. The location of enzymes in the cases of glomerulonephritis was the same as that in normal kidneys and we were unable to demonstrate any de novo expression of GST isoenzymes. However, seven out of ten renal allograft biopsies showed expression of pi class GST in proximal tubules which were atrophic. Provided there is no significant tubular atrophy, urinary release of these enzymes may be used to localise renal tubular injury.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Autoantibodies to neutrophil cytoplasmic antigens in systemic vasculitis have the same target specificity.

Many patients with systemic vasculitis have antibodies to neutrophil cytoplasm antigens (ANCA) detectable by indirect immunofluorescence. We sought to characterize further the nature of these antigens. Western blots of neutrophil protein extracts indicated that nine patients' sera, positive for ANCA by immunofluorescence, all reacted with a 45 kDa and a 27-31 kDa protein. Negative control sera, and sera taken in remission, did not react with either of these antigens. The results suggest that ANCA in vasculitis have the same target specificity and may therefore permit greater accuracy of diagnosis and increase our understanding of the pathogenesis of the conditions.

Antibody Specificity↗

Glutathione S-transferase isoenzymes in human renal carcinoma demonstrated by immunohistochemistry.

Glutathione S-transferase (GST) in man comprise at least four gene families. Three of these families give rise to cytosolic isoenzymes (alpha, mu and pi classes), whilst the remainder is membrane bound and has been called microsomal GST. These enzymes are implicated in tumourogenesis and both pi class GST and alpha class GST have been described in four cases of human renal cell carcinoma. Using specific polyclonal rabbit antisera we have demonstrated by immunohistochemistry that all 12 renal carcinomas studied contained GST pi. Most tumours also contained GST alpha, GST mu and microsomal GST isoenzymes but their distribution was heterogeneous and sometimes very focal. This heterogeneity of GST isoenzyme distribution within tumours has not been well documented previously, but is relevant to our understanding of the functions of GST, and to the interpretation of biochemical quantification experiments using tissue extracts.

Carcinoma, Renal Cell↗

Distribution of glutathione S-transferase isoenzymes in human kidney: basis for possible markers of renal injury.

To determine whether the tissue distribution of glutathione S-transferase (GST) isoenzymes could define the precise nature of renal injury, 13 adult kidneys were studied, using specific antibodies raised against purified isoenzymes. Basic GST stained strongly proximal convoluted tubules and some medullary tubules; acidic GST stained strongly distal convoluted tubules and medullary tubules; neutral GST stained similarly to acidic GST, but weaker, and microsomal GST stained glomerular and interstitial endothelium and collecting ducts deep in the medulla, although there was considerable variation in staining intensity among cases. It is suggested that the measurement of these isoenzymes in serum and urine may help to elucidate the localisation of tissue damage, which may be particularly valuable in patients with cyclosporine toxicity following renal transplantation.

Glutathione Transferase↗

Antibodies to neutrophil cytoplasmic antigens in Wegener's granulomatosis and other conditions.

The use of serum antibodies to neutrophil cytoplasmic antigens (ANCA) as a diagnostic marker for Wegener's granulomatosis and other forms of vasculitis has been assessed. Although ANCA have been described by several groups the precise antigenic targets are unknown, and detection of ANCA still relies on an indirect immunofluorescence assay technique. Several different patterns of fluorescence have been produced by using sera from different groups of patients, and insufficient information is available on the frequency of positive results and of the patterns of immunofluorescence obtained when serum from patients with vasculitis as a part of a generalised connective tissue disease is used. A study was carried out on serum from 240 patients, including 23 patients with Wegener's granulomatosis, 12 with microscopic polyarteritis, and 30 with various connective tissue diseases. Three patterns of fluorescence were observed: bright coarsely granular cytoplasmic, bright non-granular cytoplasmic, and weak diffuse cytoplasmic. The bright, coarsely granular pattern was 86% specific for Wegener's granulomatosis in this series and was observed in 18 of 23 cases. Other patterns of fluorescence were found in various conditions and were not of diagnostic value. The technique is simple, inexpensive, rapid, and reproducible.

Adult↗