[Guidance of interventions in subintimal recanalization and fenestration of dissection membranes using a novel dual-lumen intravascular ultrasound catheter].

PURPOSE: To evaluate the feasibility and effectiveness of IVUS-guided puncture for gaining controlled target lumen reentry in subintimal recanalization of chronic iliac/femoral artery occlusions and in fenestration of aortic dissections. MATERIALS AND METHODS: Between 5/2004 and 12/2005 12 consecutive patients (7 male, 5 female; mean age 64.6 +/- 12.0 years) with chronic critical limb ischemia and ischemic complications of aortic dissection were treated using the Pioneer catheter. This 6.2-F dual-lumen catheter combines a 20-MHz IVUS transducer with a pre-shaped extendable, hollow 24-gauge nitinol needle. This coaxial needle allows real-time IVUS-guided puncture of the target lumen and after successful reentry a 0.014" guidewire may be advanced through the needle into the target lumen. 7 patients were treated for aortic dissection and 5 patients (with failed previous attempts at subintimal recanalization) for chronic arterial occlusion. Patients with aortic dissection (5 type A dissections, 2 type B dissections) had developed renal ischemia (n = 2), renal and mesenteric ischemia (n = 2), or low extremity ischemia (n = 3). Patients with chronic arterial occlusions (2 common iliac artery occlusions, 3 superficial femoral artery occlusions) experienced ischemic rest pain (n = 4), and a non-healing foot ulcer (n = 1). RESULTS: The technical success rate using the Pioneer catheter was 100%. The recanalization/fenestration time was 37 +/- 12 min. Procedure-related complications did not occur. In 10 cases a significant improvement of clinical symptoms was evident. One patient with aortic dissection and ischemic paraplegia required subsequent surgical intervention. One patient had persistent ischemic rest pain despite successful recanalization of a superficial femoral artery occlusion. CONCLUSION: The Pioneer catheter is a reliable device which may be helpful for achieving target lumen reentry in subintimal recanalization of chronic occlusions and in fenestration of aortic dissections.

Aged↗

Superselective embolization of deep femoral artery branch pseudoaneurysm with a coaxial microcatheter system.

This report describes the use of transluminal coil embolization to treat pseudoaneurysm of deep femoral artery branch in two patients. The pseudoaneurysms had developed after coronary angiographv in one patient and after hip replacement in the other. Immediate control angiography after embolization procedures demonstrated complete closure of the pseudoaneurysms. During follow-up of 19 and 3 months, respectively, there was no recurrent bleeding. The aim of this case report is to show the advances in endovascular microcatheter technology, and embolic materials, that made percutaneous transluminal embolization of arterial pseudoaneurysms safe and efficient. In addition, it keeps the medical personnel aware of vascular injuries at the access site related to endovascular procedures as well as vascular complications of total hip arthroplasty. It calls their attention to the possibility of endovascular treatment as an alternative to surgery.

Aged, 80 and over↗

[Improvements in detection of rectal cancer recurrence by multiplanar reconstruction].

PURPOSE: To evaluate the advantages of multiplanar reconstruction and different axial slice thickness in diagnostic of rectal cancer recurrence after operation and radiotherapy. METHOD: We included 83 patients after operation and radiotherapy of rectal cancer in this study. All patients got a minimum of three CT-examinations in their follow-up program. A total of 294 CT-scans were evaluated. Each examination was reviewed by two experienced radiologists in respect to recurrence. Each examination was presented in axial reconstruction with a slice sickness of 8, 5, and 1.25 mm and in multiplanar reconstruction. The sensitivity, specificity, positive predictive value and accuracy were calculated. RESULTS: Multiplanar reconstructions showed better results for the detection of recurrence than axial reconstruction. A reduced slice thickness did not lead to better results in axial reconstruction. Multiplanar reconstruction showed a sensitivity of 0.88, a specificity of 0.98, an accuracy of 0.96 and a positive predictive value of 0,94, for axial reconstruction we calculated: 0.82, 0.97, 0.94 and 0.88, respectively. Sensitivity and accuracy showed a significant increase after the first and second examination. CONCLUSION: Multiplanar reconstructions allow a significant better detection of rectal cancer recurrence when compared to axial reconstructions. Thinner axial slice thickness shows no diagnostic advantage.

Germany↗

[Stents in the femoral artery: aid or problem?].

Percutaneous transluminal angioplasty (PTA) is a well-established technique in the treatment of symptomatic femoropopliteal artery stenoses and obstructions. It is a method of treatment with excellent initial technical and clinical results. However, the long-term results of PTA alone must be considered as unsatisfactory as recurrences are frequently observed. In the past, femoropopliteal stenting appeared to be a promising tool to prevent recurrence and to increase patency rates, but it did not produce better results than PTA alone. For this reason, alternative therapeutic strategies such as brachytherapy, drug-eluting pharmastents and gene therapy were developed. Several investigators are beginning to explore their potential use. This article reviews the present possibilities of PTA and stenting in the femoropopliteal region and considers potential future concepts. In this context, the current clinical literature is discussed.

Arterial Occlusive Diseases↗

[Observing the density increase curve after intravenous contrast medium administration using a bolus triggering system: a method for detection cardiovascular disorders?].

PURPOSE: Recently bolus tracking systems were developed to improve the timing of intravenous contrast media application in helical computed tomography. We investigated the benefit of this new method as a parameter of the cardiac function. MATERIAL AND METHODS: Retrospective analysis of 64 patients which incidentally underwent bolus triggered contrast enhanced helical CT and invasive investigation of the heart within one week. All examinations were performed on the CT scanner Somatom Plus 4 Volume Zoom (Siemens Corp., Forchheim, Germany) using the C.A.R.E. Bolus software. This performs repetitive low-dose test scans (e.g. for the abdomen: 140 kV, 20 mA, Tl 0.5 s) and measures the Hounsfield attenuation (increase over the baseline) in a preselected region of interest. The displayed increase of vascular density over the time after peripheral contrast media injection (75 ml lopromid (300 mg/ml), 2 ml/s) was categorised to three types: (a) rapid increase, (b) deceleration before a 100 HE threshold was reached and (c) one or more peaks. The findings of the invasive investigation of the heart were correlated to the findings of the bolus-tracking measurements. RESULTS: The examinations were categorized as follows: 19 type A, 34 type B, 11 type C. We found a high significant correlation between the type of the Hounsfield attenuation and systolic pressure in the left ventricle. There was no correlation between the type of the Hounsfield attenuation and the diastolic pressure in the left ventricle, the pressures related to the right ventricle or the ejection fraction. The bolus-tacking system showed a sensitivity of 53, a specificity of 82, an accuracy of 70%, a positive predictive value of 70% and a negative predictive value of 70% in detection of left heart failure. CONCLUSION: The bolus tracking system C.A.R.E.-bolus often shows atypical Hounsfield attenuation in cases of cardiac failure but is not suitable as a screening method of the cardiopulmonary function.

Absorptiometry, Photon↗

Stereoscopic 3D CT vs standard 3D CT in the classification of acetabular fractures: an experimental study.

The accuracy of stereoscopic and standard three-dimensional (3D) CT in the classification of acetabular fractures was compared. A receiver operating characteristic (ROC) analysis was performed by two radiologists and two surgeons blinded to the presence of acetabular fractures in an animal model (a total of 62 porcine hips, 40 with artificial acetabular fractures). Classification of acetabular fractures was adopted from the literature. Interpretation was performed on a workstation using two specific volume rendering algorithms; unshaded and shaded bone. The ROC analysis did not demonstrate any benefit in stereoscopic 3D CT compared with standard 3D CT.

Acetabulum↗

Magnetic resonance imaging in the diagnosis of Fournier's gangrene.

Magnetic resonance imaging and ultrasound are the imaging modalities recommended in the early diagnosis of Fournier's gangrene. Because of the high mortality of this inflammatory disease early diagnosis is essential to initiate adequate surgical and medical treatment. In the clinical literature only a handful of cases, in which diagnosis of Fournier's gangrene is based on MRI findings, have been reported; therefore, we report another case which shows the ability of MRI especially to determine the point of origin and extension of disease.

Adult↗

Optimized enhancement in helical CT: experiences with a real-time bolus tracking system in 628 patients.

AIMS: Ultrafast detector technology enables bolus-triggered application of contrast media. In a prospective study we investigated the benefit of this new method with the intention of optimizing enhancement during examination of the chest and abdomen. MATERIALS AND METHODS: In total, we examined 548 patients under standardized conditions. All examinations were performed on a Somatom Plus 4 Power CT system (Siemens Corp., Forchheim, Germany) using the CARE-Bolus software. This produces repetitive low-dose test images (e.g. for the lung: 140 kV, 43 mA, TI 0.5 s) and measures the Hounsfield attenuation in a pre-selected region of interest. After exceeding a defined threshold, a diagnostic spiral CT examination was begun automatically. The data obtained from 321 abdominal CT and 179 lung CT examinations were correlated with different parameters such as age, weight and height of the patients and parameters of vascular access. In a group of 80 patients, the injection of contrast medium was stopped after reaching a pre-defined threshold of an increase of 100 HU over the baseline. Then, we assessed the maximal enhancement of liver, pulmonal artery trunk and aortic arch. RESULTS: There was no correlation between bolus geometry and age, body surface or weight. In helical CT of the abdomen the threshold was reached after a mean trigger time of 27 s (range 13-67 s) and only 65 ml (range 41-105 ml) of contrast medium were administered. In helical CT of the lung the threshold was reached after 21 s (range 12-48 s) and the mean amount of administered contrast medium was 48 ml (range 38-71 ml). CONCLUSION: Bolus triggering allows optimized enhancement of the organs and reduces the dose of contrast material required compared with standard administration.

Abdominal Neoplasms↗

[Duodeno-ileal fistula development due to retroperitoneal lymph node metastases of sigmoid carcinoma].

We report on a 75-year-old patient suffering from persistent diarrhea with consecutive weight loss of 50 kg over a nine month period. Three years ago the patient had been operated on a sigmoid cancer. Ultrasonography and CT-scan revealed retroperitoneal masses due to lymph node metastases. Enteroclysis demonstrated a fistula between the duodenum and the terminal ileum. Whereas duodenocolic fistulae due to malignancies are well known to the best of our knowledge a fistula between retroperitoneal parts of the duodenum and the intraperitoneal intestine have not descripted so far.

Aged↗

[Virtual bronchoscopy in the child using multi-slice CT: initial clinical experiences].

PURPOSE: Virtual bronchoscopy of the pediatric patient has been reported to be more difficult because of artifacts due to breathing or motion. We demonstrate the benefit of the accelerated examination based on multislice spiral CT (MSCT) in the pediatric patient which has not been reported so far. MATERIAL AND METHODS: MSCT (tube voltage 120 kV, tube current 110 mA, 4 x 1 mm Slice thickness, 500 ms rotation time, Pitch 6) was performed on a CT scanner of the latest generation (Volume Zoom, Siemens Corp. Forchheim, Germany). In totally we examined 11 patients (median age 48 months, range 2-122 months) suspected of having tracheoesophageal fistula (n = 2), tracheobronchial narrowing (n = 8) due to intrinsic or extrinsic factors or injury of the bronchial system (n = 1). RESULTS: In all patients we obtained sufficient data for 3D reconstruction avoiding general anesthesia. 6/11 examinations were described to be without pathological finding. A definite diagnosis was obtained in 10 patients. Virtual bronchoscopy could avoid other invasive diagnostic examination in 8/11 patients (73%). CONCLUSION: Helical CT provides 3D-reconstruction and virtual bronchoscopy in the newborn as well as the infant. It avoids additional diagnostic bronchoscopy in a high percentage of all cases.