Stent placement compared with balloon angioplasty for small coronary arteries: in-hospital and 6-month clinical and angiographic results.

BACKGROUND: Stenting has been demonstrated to be superior to balloon angioplasty in de novo focal lesions located in large native vessels. However, in small vessels, the benefit of stenting remains questionable. METHODS AND RESULTS: A total of 381 symptomatic patients with de novo focal lesion located on a small coronary segment vessel (<3 mm) were randomly assigned to either stent implantation (192 patients; 197 lesions) or standard balloon angioplasty (189 patients; 198 lesions). The primary end point was the angiographic restenosis rate at 6 months, as determined by quantitative coronary angiography. On intention-to-treat analysis, angiographic success rate and major adverse cardiac events were comparable: 97.9% and 4.6% versus 93.9% and 5.8% in the stent group and the balloon group, respectively. After the procedure, a larger acute gain was achieved with stent placement (1.35+/-0.45 versus 0.94+/-0.47 mm, P=0.0001), resulting in a larger minimal lumen diameter (2.06+/-0.42 versus 1.70+/-0.46 mm, P=0.0001). At follow-up (obtained in 91% of patients), angiographic restenosis rate was 21% in the stent group versus 47% in the balloon group (P=0.0001), a risk reduction of 55%. Repeat target lesion revascularization was less frequent in the stent group (13% versus 25%, P=0.0006). CONCLUSIONS: Elective stent placement in small coronary arteries with focal de novo lesions is safe and associated with a marked reduction in restenosis rate and subsequent target lesion revascularization rate at 6 months.

Angioplasty, Balloon, Coronary↗

Exercise-induced ST-elevation is related to left ventricular dysfunction but not to myocardial viability in patients with healed myocardial infarction.

BACKGROUND: Exercise-induced ST-segment elevation was proposed as a marker of myocardial viability after a recent myocardial infarction. AIMS: The aim of this study was to evaluate whether exercise-induced ST segment elevation is related to viability or to left ventricular dysfunction in patients with history of old Q wave myocardial infarction. METHODS: Fifty patients (43 men, age 57+/-11 years) were studied 31+/-49 months after a Q wave myocardial infarction. They all underwent stress, reinjection-redistribution, and late redistribution Tl-201 SPECT, completed by equilibrium radionuclide angiography. Viability was defined by defect reversibility or significant (>60%) persistent Tl-201 uptake in dyssinergic segments on late redistribution SPECT. Relative post-exercise and reinjection-redistribution LV volumes were calculated using validated software (QGS). RESULTS: Twenty-one out of 50 patients (42%, G1) had significant stress-induced ST-elevation (>1 mm 80 ms after J point in at least 2 ECG leads with Q wave), and 29/50 (58%, G2) did not. Seventeen out of 50 patients (34%) demonstrated myocardial viability on late redistribution scan. The diagnostic accuracy of exercise-induced ST-elevation was only 52% for viability assessment. Significant LVEF reduction and increased relative LV volumes were observed in G1 compared to G2 (LVEF: 39+/-10% vs. 49+/-11%, P=0.003; post-stress LV volume: 134+/-98 ml vs. 81+/-41 ml, P<0.02; reinjection-redistribution LV volume: 123+/-86 ml vs. 79+/-40 ml; P<0.02). Perfusion defects were similar in G1 and G2 (post-exercise: 38+/-12% vs. 37+/-14%, ns; reinjection-redistribution: 31+/-11% vs. 30+/-11%, ns; late redistribution: 30+/-10% vs. 28+/-11%, ns). CONCLUSION: These results suggest that, in patients with history of myocardial infarction, exercise-induced ST-segment elevation is not related to persistent myocardial viability but is associated to left ventricular dysfunction.

Aged↗

Transvenous catheter embolectomy.

Transvenous pulmonary embolectomy was first described in 1969 by Greenfield and associates who designed a special catheter for the aspiration of thrombi in the pulmonary circulatory system. This technique was applied in 64 patients with massive pulmonary embolism (PE) with a 70 to 72% survival rate. However, it is difficult to implement and has not gained widespread acceptance. More recently, several other catheter devices have been used in patients with PE. The total number of patients reported does not exceed 100. Relative angiographic improvement varies between 10 and 49%, but hemodynamic improvement is not observed or not measured in most patients and mortality varies between 9 and 30%. Fibrinolysis was associated with mechanical thrombectomy in 54% of the patients, making the results difficult to interpret. Transvenous pulmonary embolectomy remains an experimental procedure and should been attempted only in the very few patients with PE, uncontrolled cardiogenic shock, and absolute contraindication to fibrinolytic treatment. Animal models are required to compare the different devices available.

Catheterization, Central Venous↗

[Percutaneous revascularization of multivessel coronary disease with systematic stent implantation. Immediate results and clinical follow-up and middle term angiography].

The aim of this retrospective study was to assess the immediate and medium-term clinical and angiographic results of multiple angioplasty with stenting in 100 consecutive patients with multivessel coronary artery disease. The mean age of the population was 62 +/- 11 years. Two hundred and eight lesions were treated (2.5 +/- 0.7 per patient) with implantation of 1.14 +/- 0.4 stents per lesion. The angiographic success rate was 98.7%. There were 5 major complications in the hospital period: 3 deaths, including 2 of cardiac causes, one coronary bypass procedure and one Q wave myocardial infarction. During follow-up (17 +/- 6 months), eight patients died (5 of cardiac causes) and secondary revascularisation procedures were required in 22 patients. At 6 months, the angiographic restenosis rate was 32% per lesion, 28.8% per stent and 33 patients had at least one restenosis.

Adult↗

Effect of temporal sampling on evaluation of left ventricular ejection fraction by means of thallium-201 gated SPET: comparison of 16- and 8-interval gating, with reference to equilibrium radionuclide angiography.

Gated myocardial single-photon emission tomography (SPET) allows the evaluation of left ventricular ejection fraction (LVEF), but temporal undersampling may lead to systolic truncation and ejection fraction underestimation. The aim of this study was to evaluate the impact of temporal sampling on thallium gated SPET LVEF measurements. Fifty-five consecutive patients (46 men, mean age 62+/-12 years) with a history of myocardial infarction (anterior 31, inferior 24) were studied. All patients underwent equilibrium radionuclide angiography (ERNA) and gated SPET 4 h after a rest injection of 185 MBq (5 mCi) of thallium-201 using either 8-interval (group 1, n=25) or 16-interval gating (group 2, n=30). In group 2, gated SPET acquisitions were automatically resampled to an 8-interval data set. Projection data were reconstructed using filtered back-projection (Butterworth filter, order 5, cut-off 0.20). LVEF was then calculated using commercially available software (QGS). A higher correlation between gated SPET and ERNA was obtained with 16-interval gating (r=0.94) compared with the resampled data set (r=0.84) and 8-interval gating (r=0.71). Bland-Altman plots showed a dramatic improvement in the agreement between gated SPET and ERNA with 16-interval gating (mean difference: -0.10%+/-5%). Using multiple ANOVA, temporal sampling was the only parameter to influence the difference between the two methods. When using 8-interval gating, gated SPET LVEF was overestimated in women and underestimated in men (ERNA minus gated SPET = -4.0%+/-9.6% in women and 3.6%+/-7.6% in men, P=0.01). In conclusion, 16-interval thallium gated SPET offered the best correlation and agreement with ERNA, and should be preferred to 8-interval gated acquisition for LVEF measurement.

Adult↗

A comparison of systematic stenting and conventional balloon angioplasty during primary percutaneous transluminal coronary angioplasty for acute myocardial infarction. STENTIM-2 Investigators.

OBJECTIVES: In a multicenter, randomized trial, systematic stenting using the Wiktor stent was compared to conventional balloon angioplasty with provisional stenting for the treatment of acute myocardial infarction (AMI). BACKGROUND: Primary angioplasty in AMI is limited by in-hospital recurrent ischemia and a high restenosis rate. METHODS: A total of 211 patients with AMI <12 h from symptom onset, with an occluded native coronary artery, were randomly assigned to systematic stenting (n = 101) or balloon angioplasty (n = 110). The primary end point was the binary six-month restenosis rate determined by core laboratory quantitative angiographic analysis. RESULTS: Angiographic success (Thrombolysis in Myocardial Infarction [TIMI] flow grade 3 and residual diameter stenosis <50%) was achieved in 86% of the patients in the stent group and in 82.7% of those in the balloon angioplasty group (p = 0.5). Compared with the 3% cross-over in the stent group, cross-over to stenting was required in 36.4% of patients in the balloon angioplasty group (p = 0.0001). Six-month binary restenosis (> or = 50% residual stenosis) rates were 25.3% in the stent group and 39.6% in the balloon angioplasty group (p = 0.04). At six months, the event-free survival rates were 81.2% in the stent group and 72.7% in the balloon angioplasty group (p = 0.14), and the repeat revascularization rates were 16.8% and 26.4%, respectively (p = 0.1). At one year, the event-free survival rates were 80.2% in the stent group and 71.8% in the balloon angioplasty group (p = 0.16), and the repeat revascularization rates were 17.8% and 28.2%, respectively (p = 0.1). CONCLUSIONS: In the setting of primary angioplasty for AMI, as compared with a strategy of conventional balloon angioplasty, systematic stenting using the Wiktor stent results in lower rates of angiographic restenosis.

Angioplasty, Balloon↗

[Percutaneous mitral commissurotomy by metallic dilator. Multicenter experience with 500 patients].

A clinical investigation has been conducted since January 1996 with a new valve dilator for percutaneous treatment of mitral stenosis: metallic commissurotome. This new technique is based on the principle of surgical commissurotome but, in its mechanism of action, differs from the usual techniques with balloon catheters. It also offers the unique possibility for multiple utilizations of the same device after resterilization. This article reports a multicenter international investigation involving 500 patients, mean age of 34 +/- 13 years, with a isolated mitral stenosis and an echography score of 7.7 +/- 1.9. Our technique has been feasible in 489 cases (98%) with a success rate (mitral area > 1.5 cm2 without MR > grade 2) of 93%. The transmitral gradient has diminished from 20 +/- 8 mmHg to 4 +/- 3 mm Hg and the mitral area (assessed by planimetry at 24 hrs) has increased from 0.91 +/- 0.20 to 2.12 +/- 0.34 cm2. Complications were uncommon (13 patients: 2.6%) and consisted in 6 tamponades, 5 mitral insufficiencies (one patient required an emergency valve replacement) and 2 neurological transient accidents. The outcomes of this clinical investigation appear most encouraging and at least comparable to those being reported with the commonly used techniques. The most serious complications appear to be closely related to the level of experience with this technique. Considering the possibility to reutilize the metal segments of the apparatus, this technique notably reduces the cost of the procedure per patient and it represents a significant benefit in countries with limited resources.

Adult↗

Percutaneous mechanical mitral commissurotomy with a newly designed metallic valvulotome: immediate results of the initial experience in 153 patients.

BACKGROUND: Percutaneous balloon valvotomy has become a common treatment of mitral stenosis, but the cost of the procedure remains a limitation in countries with restricted financial resources, leading to a frequent reuse of the disposable catheters. To overcome this limitation, a reusable metallic valvotomy device has been developed with the goals of both improving the mitral valvotomy results and decreasing the cost of the procedure. METHODS AND RESULTS: The device consists of a detachable metallic cylinder with 2 articulated bars screwed onto the distal end of a disposable catheter whose proximal end is connected to an activating pliers. By the transseptal route, the device is advanced across the valve over a traction guidewire. Squeezing the pliers opens the bars up to a maximum extent of 40 mm. The clinical experience consisted of 153 patients with a broad spectrum of mitral valve deformities. The procedure was successful in 92% of cases and resulted in a significant increase in mitral valve area, from 0.95+/-0.2 to 2. 16+/-0.4 cm2. No increase in mitral regurgitation was noted in 80% of cases. Bilateral splitting of the commissures was observed in 87%. Complications were 2 cases of severe mitral regurgitation (1 requiring surgery), 1 pericardial tamponade, and 1 transient cerebrovascular embolic event. In this series, the maximum number of consecutive patients treated with the same device was 35. CONCLUSIONS: The results obtained with this new device are encouraging and at least comparable to those of current balloon techniques. Multiple uses after sterilization should markedly decrease the procedural cost, a major advantage in countries with limited resources and high incidence of mitral stenosis.

Adolescent↗

Thallium-gated SPECT in patients with major myocardial infarction: effect of filtering and zooming in comparison with equilibrium radionuclide imaging and left ventriculography.

UNLABELLED: The effect of filtering and zooming on 201TI-gated SPECT was evaluated in patients with major myocardial infarction. METHODS: Rest thallium (TI)-gated SPECT was performed with a 90 degrees dual-head camera, 4 h after injection of 185 MBq 201TI in 32 patients (mean age 61 +/- 11 y) with large myocardial infarction (33% +/- 17% defect on bull's eye). End diastolic volume (EDV), end systolic volume (ESV) and left ventricular ejection fraction (LVEF) were calculated using a commercially available semiautomatic validated software. First, images were reconstructed using a 2.5 zoom, a Butterworth filter (order = 5) and six Nyquist cutoff frequencies: 0.13 (B5.13), 0.15 (B5.15), 0.20 (B5.20), 0.25 (B5.25), 0.30 (B5.30) and 0.35 (B5.35). Second, images were reconstructed using a zoom of 1 and a Butterworth filter (order = 5) (cutoff frequency 0.20 [B5.20Z1]) (total = 32 x 7 = 224 reconstructions). LVEF was calculated in all patients using equilibrium radionuclide angiocardiography (ERNA). EDV, ESV and LVEF were measured with contrast left ventriculography (LVG). RESULTS: LVEF was 39% +/- 2% (mean +/- SEM) for ERNA and 40% +/- 13% for LVG (P = 0.51). Gated SPECT with B5.20Z2.5 simultaneously offered a mean LVEF value (39% +/- 2%) similar to ERNA (39% +/- 2%) and LVG (40% +/- 3%), optimal correlations with both ERNA (r = 0.83) and LVG (r = 0.70) and minimal differences with both ERNA (-0.9% +/- 7.5% [mean +/- SD]) and LVG (1.1% +/- 10.5%). As a function of filter and zoom choice, correlation coefficients between ERNA or LVG LVEF, and gated SPECT ranged from 0.26 to 0.88; and correlation coefficients between LVG and gated SPECT volumes ranged from 0.87 to 0.94. There was a significant effect of filtering and zooming on EDV, ESV and LVEF (P < 0.0001). Low cutoff frequency (B5.13) overestimated LVEF (P < 0.0001 versus ERNA and LVG). Gated SPECT with 2.5 zoom and high cutoff frequencies (B5.15, B5.20, B5.25, B5.30 and B5.35) overestimated EDV and ESV (P < 0.04) compared with LVG. This volume overestimation with TI-gated SPECT in patients with large myocardial infarction was correlated to the infarct size. A zoom of 1 underestimated EDV, ESV and LVEF compared with a 2.5 zoom (P < 0.02). CONCLUSION: Accurate LVEF measurement is possible with TI-gated SPECT in patients with major myocardial infarction. However, filtering and zooming greatly influence EDV, ESV and LVEF measurements, and TI-gated SPECT overestimates left ventricular volumes, particularly when the infarct size increases.

Female↗

Primary stenting of de novo lesions in small coronary arteries: a prospective, pilot study.

Technical advancement and new anti-thrombotic regimens have recently shown so much improvement in the results of coronary stenting that the conventional contra-indication for stenting in small coronary arteries (<3 mm) needs to be revised. We undertook a prospective pilot study of elective Palmaz-Schatz stenting in de novo lesions located in coronary arteries of less than 3 mm diameter. Fifty consecutive patients (63 +/- 9 years) with stable (n = 38) and unstable angina (n = 12) were included. Philips-DCI quantitative coronary analysis was used to measure reference diameter, minimal lumen diameter and percent diameter stenosis before PTCA, after stenting and at 6-month angiographic follow-up study. All measurements were performed after intracoronary injection of nitroglycerin (300 microg). All patients received ticlopidine (250 mg/day) and aspirin (100 mg/day). The mean lesion length was 9 +/- 3 mm. The balloon size used for stent delivery was 2.75 mm in 30 patients and 2.5 mm in 20 patients and the mean balloon inflation pressure used for stent deployment was 12 +/- 2 atm. All stents were deployed successfully. In-hospital complications occurred in two patients, diagonal branch occlusion at day 2 requiring emergency PTCA in one and a hematoma at the femoral puncture site requiring surgery in the other. Major adverse cardiac event (MACE) rate remained 2% (nonfatal infarct in one). Follow-up angiography (n = 46, 92%) at 6 +/- 3 months showed a 30% restenosis rate. Target vessel revascularization (TVR) rate was 13%. We conclude that elective stenting in small coronary arteries is feasible and involves an acceptable risk of restenosis.

Angina Pectoris↗

Balloon angioplasty for the treatment of coronary in-stent restenosis: immediate results and 6-month angiographic recurrent restenosis rate.

OBJECTIVES: The purpose of this prospective study was to evaluate the immediate results and the 6-month angiographic recurrent restenosis rate after balloon angioplasty for in-stent restenosis. BACKGROUND: Despite excellent immediate and mid-term results, 20% to 30% of patients with coronary stent implantation will present an angiographic restenosis and may require additional treatment. The optimal treatment for in-stent restenosis is still unclear. METHODS: Quantitative coronary angiography (QCA) analyses were performed before and after stent implantation, before and after balloon angioplasty for in-stent restenosis and on a 6-month systematic coronary angiogram to assess the recurrent angiographic restenosis rate. RESULTS: Balloon angioplasty was performed in 52 patients presenting in-stent restenosis. In-stent restenosis was either diffuse (> or =10 mm) inside the stent (71%) or focal (29%). Mean stent length was 16+/-7 mm. Balloon diameter of 2.98+/-0.37 mm and maximal inflation pressure of 10+/-3 atm were used for balloon angioplasty. Angiographic success rate was 100% without any complication. Acute gain was lower after balloon angioplasty for in-stent restenosis than after stent implantation: 1.19+/-0.60 mm vs. 1.75+/-0.68 mm (p=0.0002). At 6-month follow-up, 60% of patients were asymptomatic and no patient died. Eighteen patients (35%) had repeat target vessel revascularization. Angiographic restenosis rate was 54%. Recurrent restenosis rate was higher when in-stent restenosis was diffuse: 63% vs. 31% when focal, p=0.046. CONCLUSIONS: Although balloon angioplasty for in-stent restenosis can be safely and successfully performed, it leads to less immediate stenosis improvement than at time of stent implantation and carries a high recurrent angiographic restenosis rate at 6 months, in particular in diffuse in-stent restenosis lesions.

Angioplasty, Balloon, Coronary↗

[Percutaneous coronary angioscopy in the diagnosis of cardiac graft coronary disease: comparison with the results of angiography].

Coronary disease in cardiac transplant patients is a major factor in the limitation of long term survival. The aim of this study was to compare the results of angioscopy with those of coronary angiography performed systematically every 18 months in our center. Twenty-nine patients (31 angioscopies) were assessed 38 +/- 21 months after transplantation. The appearance observed by angioscopy were: 1) normal, 2) yellow pigmentation of the arterial surface, 3) elevated plaque < 50%, 4) elevated plaque > or = 50% stenosis. Angiography was: 1) normal, 2) iregularities of the lumen or < 50% stenosis, 3) > or = 50% stenosis. The films were viewed by two independent investigators. Angioscopy was performed on the left anterior descending artery (N = 35), the left circumflex (N = 24) and the right coronary artery (N = 9). One to three arterial segments were examined per vessel (total of 117 segments: average 3.8 segments per patient). Angioscopy was uniterpretable in 13/117 (11%) of cases. Of the 81 (78%) segments considered normal at coronary angiography, only 55 seemed normal at angioscopy (68%). Of the 23 segments considered to be abnormal at coronary angiography, all were also considered to be abnormal at angioscopy. The authors conclude that coronary angioscopy seems to be more sensitive than coronary angiography for the detection of coronary disease due to chronic rejection. Prospective studies are required to determine whether the infra-angiographic angioscopic lesions correspond to earlier stages of coronary disease of the cardiac graft.

Aged↗

[Detection of myocardial viability by echocardiography with dobutamine infusion three weeks after myocardial infarction].

The aim of this study was to assess the value of low dose dobutamine (5 and 10 gammas/Kg/min) echocardiography for the detection of hibernating myocardium in an infarcted zone three weeks after the initial infarction. The authors studied 23 patients (18 men, 15 women) with an average age of 59 +/- 8 years before and 3 months after angioplasty of the culprit artery. Segmental wall motion was assessed semi-quantitatively by the criteria of the American Society of Echocardiography. All patients had regional contractile abnormalities under basal conditions and all underwent control coronary angiography at 3 months. Improvement of segmental wall motion with dobutamine predicted improvement after revascularisation with positive and negative predictive values of 95% and 85% respectively. The sensitivity and specificity of the test calculated in the usual manner were 83% and 96% respectively. In addition, assessment of diastolic function showed reduction of the isovolumic relaxation time with dobutamine only in patients with hibernating myocardium (120 +/- 30 ms decreasing to 114 +/- 29 ms with dobutamine, p < 0.02). Low dose dobutamine echocardiography therefore allows reliable non-invasive prediction of hibernating myocardium three weeks after infarction. The reduction of isovolumic relaxation time with dobutamine could be an additional argument in favour of the diagnosis.

Aged↗

[Immediate and 6-month results of balloon angioplasty in the treatment of intra-stent restenosis in symptomatic patients].

The aim of this prospective study was to assess the clinical and angiographic immediate and 6 month results of balloon angioplasty in intra-stent restenosis. Quantitative angiographic analysis (Philips DCI) was performed before and after implantation of the stent, before and after angioplasty for restenosis and at the 6 month control procedure. The study included 59 patients with 65 stents with an intra-stent restenosis. Restenosis was diffuse (10 mm) in 70% of cases, and focal in 30% of cases. The length of the stent was 16 +/- 7 mm (Palmaz-Schatz: 58%). The diameter of the balloon used for angioplasty was 2.9 +/- 0.4 mm and the maximal inflation pressure was 10 +/- 3 bars. The success rate was 100% with no complications. Control coronary angiography was performed in 92% of patients after an average of 5.9 months. The angiographic restenosis rate was 54% and revascularisation was required in 21 patients (36%). The restenosis rate was higher in cases of diffuse intra-stent restenosis (64%) than in focal restenosis (29%), p = 0.02. The authors conclude that balloon angioplasty for intra-stent restenosis is safe and carries a high success rate. Nevertheless, the angiographic restenosis rate at 6 months seems to be higher, especially in cases of diffuse restenosis.

Angioplasty, Balloon, Coronary↗

A new treatment for severe pulmonary embolism: percutaneous rheolytic thrombectomy.

BACKGROUND: The rheolytic thrombectomy catheter has been specially designed to remove intravascular thrombus from coronary and peripheral arteries. It demonstrates a practical application of Bernoulli's principle relating to a low-pressure zone in the region of a high-velocity jet. In this device, this effect is created by direct high-pressure saline jets located at the tip. Thrombus is drawn into this region and, because of the large pressure difference, undergoes mechanical thrombolysis due to the powerful mixing forces. The resulting microparticles are aspirated through the same catheter and removed from the body. METHODS AND RESULTS: We report the use of this device in two patients presenting with severe pulmonary embolism and contraindications to thrombolytic therapy. The two procedures were successfully performed with an excellent immediate angiographic result at the site of the rheolytic thrombectomy. In both cases, the clinical improvement was maintained at follow-up with the same good angiographic result and a decrease to a normal level of the systolic pulmonary pressure. CONCLUSIONS: This preliminary results suggest that this easy technical method may be useful in the treatment of life-threatening pulmonary embolism in patients with absolute contraindications to thrombolytic therapy. A larger cohort of patients is necessary to determine whether this treatment should be proposed as an alternative to the use of fibrinolytics in selected patients.

Aged↗