PubMed Health⌕ Search

Biomedical subjects

R Krammer

Publications and source records attributed to R Krammer.

3 recordsLinked to original sources

[Comparative biological availability of two different ibuprofen granules].

Bioavailability of ibuprofen (CAS 15687-27-1) was investigated in 12 healthy volunteers who received 2 sachets of newly developed effervescent granules (Imbun), each containing 500 mg of ibuprofen lysine salt (corresponding to 292.6 mg of ibuprofen) as the test preparation and 1 sachet of commercially available granules containing 600 mg ibuprofen. Blood samples were withdrawn pre-dose and at 16 occasions until 10 h post dose. Ibuprofen plasma concentrations were assayed by HPLC using a proprietary column-switching technique. Maximum plasma concentrations, Cmax, and times of their occurrence, tmax, were taken from the plasma data directly, areas under the plasma level/time curves, AUC0-10, were calculated using the trapezoidal rule. Pharmacokinetic parameters were checked for significant differences using ANOVA with p = 0.05. When the test preparation was applied maximum ibuprofen levels of 60 +/- 17 micrograms/ml were reached at 27 +/- 17 min p. appl. while Cmax was 52 +/- 12 micrograms/ml at tmax = 94 +/- 27 min after application of the reference preparation. AUC values were 150 +/- 44 microgramsh/ml (test) and 148 +/- 33 microgramsh/ml (reference), respectively. Thus, relative bioavailability of ibuprofen was 101.8 +/- 16.3% (or 104.1 +/- 16.7% when the slight differences in doses were corrected for). Differences in extent of absorption as measured by AUC and Cmax proved to be insignificant whereas differences in absorption rate as measured by tmax were highly significant (p < 0.001).

Adult↗

Bioavailability and pharmacokinetics of rectally administered metoclopramide.

The absolute and relative bioavailability of metoclopramide following the administration of a single suppository--test (Gastrosil) and reference preparations--containing 20 mg of the pure drug or after i.v. injection of 17.8 mg was compared in 12 sex matched healthy volunteers according to an open, three-way cross-over, intra-individual design. The metoclopramide plasma levels were determined up to 32 h following rectal administration and 24 h following intravenous application using a modified and specific HPLC-assay. The areas under the concentration-time curves were either calculated to the last time-interval measured (AUC-1) by using the trapezoidal rule or by extrapolating to infinity (AUC(0-infinity] in a model-dependent manner. Pair-differences and ratios were taken for the individual AUC-values and for the maximum plasma levels (cmax-values) at the corresponding time values (tmax-values) for test and reference formulations and tested for statistical significance. The results showed the mean AUC-1 and AUC (0-infinity)-values respectively to be 10.7% and 9.5% lower for the test suppository. The mean tmax-values were found to be 21% and 11.6% lower and the mean cmax-values were found to be about 4.3% larger than the corresponding parameters for the reference formulation. The 95% Wilcoxon confidence limits for both test and reference preparation were found to range from 80.2-108.9% for all AUC-values and to lie in the region 83.5-120.3% and 57.8-100% for the cmax- and tmax-values, respectively. Thus, with respect to the pharmacokinetic target parameters, little difference can be found between the two suppository forms each containing 20 mg metoclopramide-base and under trial in this study.(ABSTRACT TRUNCATED AT 250 WORDS)

Administration, Rectal↗