Shear-stress and wall-stress regulation of vascular remodeling after balloon angioplasty: effect of matrix metalloproteinase inhibition.

BACKGROUND: Constrictive vascular remodeling (VR) is the most significant component of restenosis after balloon angioplasty (PTA). Whereas in physiological conditions VR is associated with normalization of shear stress (SS) and wall stress (WS), after PTA the role of SS and WS in VR is unknown. Furthermore, whereas matrix metalloproteinase inhibition (MMPI) has been shown to modulate VR after PTA, its effect on the SS and WS control mechanisms after PTA is unknown. METHODS AND RESULTS: PTA was performed in external iliac arteries of 12 atherosclerotic Yucatan pigs, of which 6 pigs (7 vessels) received the MMPI batimastat and 6 pigs (10 vessels) served as controls. Before and after the intervention and at 6-week follow-up, intravascular ultrasound pullback was performed, allowing 3D reconstruction of the treated segment and computational fluid dynamics to calculate the media-bounded area and SS. WS was derived from the Laplace formula. Immediately after PTA, media-bounded area, WS, and SS changed by 20%, 16%, and -49%, respectively, in both groups. VR was predicted by SS and WS. In the control group, SS and WS had been normalized at follow-up with respect to the reference segment. In contrast, for the batimastat group, the SS had been normalized, but not the WS. The latter is attributed to an increase in wall area at follow-up. CONCLUSIONS: Vascular remodeling after PTA is controlled by both SS and WS. MMPI inhibited the WS control system.

Angioplasty, Balloon↗

Relationship between neointimal thickness and shear stress after Wallstent implantation in human coronary arteries.

BACKGROUND: In-stent restenosis by excessive intimal hyperplasia reduces the long-term clinical efficacy of coronary stents. Because shear stress (SS) is related to plaque growth in atherosclerosis, we investigated whether variations in SS distribution are related to variations in neointima formation. METHODS AND RESULTS: In 14 patients, at 6-month follow-up after coronary Wallstent implantation, 3D stent and vessel reconstruction was performed with a combined angiographic and intravascular ultrasound technique (ANGUS). The bare stent reconstruction was used to calculate in-stent SS at implantation, applying computational fluid dynamics. The flow was selected to deliver an average SS of 1.5 N/m(2). SS and neointimal thickness (Th) values were obtained with a resolution of 90 degrees in the circumferential and 2.5 mm in the longitudinal direction. For each vessel, the relationship between Th and SS was obtained by linear regression analysis. Averaging the individual slopes and intercepts of the regression lines summarized the overall relationship. Average Th was 0.44+/-0.20 mm. Th was inversely related to SS: Th=(0.59+/-0.24)-(0.08+/-0.10)xSS (mm) (P<0.05). CONCLUSIONS: These data show for the first time in vivo that the Th variations in Wallstents at 6-month follow-up are inversely related to the relative SS distribution. These findings support a hemodynamic mechanism underlying in-stent neointimal hyperplasia formation.

Coronary Circulation↗

Oxygen wastage of stunned myocardium in vivo is due to an increased oxygen cost of contractility and a decreased myofibrillar efficiency.

OBJECTIVE: We investigated whether an increased oxygen cost of contractility and/or a decreased myofibrillar efficiency contribute to oxygen wastage of stunned myocardium. Because Ca(2+)-sensitizers may increase myofibrillar Ca(2+)-sensitivity without increasing cross-bridge cycling, we also investigated whether EMD 60263 restores myofibrillar efficiency and/or the oxygen cost of contractility. METHODS: Regional fiber stress and strain were calculated from mesomyocardially implanted ultrasound crystals and left ventricular pressure in anesthetized pigs (n=18). Regional myocardial oxygen consumption (MVO(2)) was measured before contractility (end-systolic elastance, E(es)) and total myofibrillar work (stress-strain area, SSA) were determined from stress-strain relationships. Atrial pacing at three heart rates and two doses of dobutamine were used to vary SSA and E(es), respectively. After stunning (two times 10-min ischemia followed by 30-min reperfusion), measurements were repeated following infusion of saline (n=8) or EMD 60263 (1.5 mg.kg(-1) i.v., n=10). Linear regression was performed using: MVO(2)=alpha.SSA+beta.E(es)+gamma.HR(-1) (alpha(-1), myofibrillar efficiency; beta, oxygen cost of contractility; and gamma, basal metabolism/min). RESULTS: Stunning decreased SSA by 57% and E(es) by 64%, without affecting MVO(2), while increasing alpha by 71% and beta by 134%, without affecting gamma. From the wasted oxygen, 72% was used for myofibrillar work and 18% for excitation-contraction coupling. EMD 60263 restored both alpha and beta. CONCLUSIONS: Oxygen wastage in stunning is predominantly caused by a decreased myofibrillar efficiency and to a lesser extent by an increased oxygen cost of contractility. Considering that EMD 60263 reversed both causes of oxygen wastage, it is most likely that this drug increases myofibrillar Ca(2+)-sensitivity without increasing myofibrillar cross-bridge cycling.

Animals↗

Decrease in coronary vascular volume in systole augments cardiac contraction.

Coronary arterial inflow is impeded and venous outflow is increased as a result of the decrease in coronary vascular volume due to cardiac contraction. We evaluated whether cardiac contraction is influenced by interfering with the changes of the coronary vascular volume over the heart cycle. Length-tension relationships were determined in Tyrode-perfused rat papillary muscle and when coronary vascular volume changes were partly inhibited by filling it with congealed gelatin or perfusing it with a high viscosity dextran buffer. Also, myocyte thickening during contraction was reduced by placing a silicon tube around the muscle. Increasing perfusion pressure from 8 to 80 cmH2O, increased developed tension by approximately 40%. When compared with the low perfusion state, developed tension of the gelatin-filled vasculature was reduced to 43 +/- 6% at the muscle length where the muscle generates the largest developed tension (n = 5, means +/- SE). Dextran reduced developed tension to 73 +/- 6% (n = 6). The silicon tube, in low perfusion state, reduced the developed tension to 83 +/- 7% (n = 4) of control. Time-control and oxygen-lowering experiments show that the findings are based on mechanical effects. Thus interventions to prevent myocyte thickening reduce developed tension. We hypothesize that when myocyte thickening is prevented, intracellular pressure increases and counteracts the force produced by the contractile apparatus. We conclude that emptying of the coronary vasculature serves a physiological purpose by facilitating cardiomyocyte thickening thereby augmenting force development.

Animals↗

In vivo evidence that EMD 57033 restores myocardial responsiveness to intracoronary Ca(2+) in stunned myocardium.

Despite ample in vitro evidence that myofilament Ca(2+)-responsiveness of stunned myocardium is decreased, in vivo data are inconclusive. Conversely, while Ca(2+)-sensitizing agents increase myofilament Ca(2+)-responsiveness in vitro, it has been questioned whether this also occurs in vivo. We therefore tested in open-chest anesthetized pigs whether EMD 57033 (the (+) enantiomer of 5-[1-(3,4-dimethoxybenzoyl)-1,2,3, 4-tetrahydro-6-quinolyl]-6-methyl-3,6-dihydro-2H-1,3, 4-thiadiazin-2-one) increases responsiveness to Ca(2+) of non-stunned myocardium and restores function of stunned myocardium by normalizing the responsiveness to Ca(2+). Studies were performed under beta-adrenoceptor blockade to minimize the contribution of the phosphodiesterase-III inhibitory actions of EMD 57033. Consecutive intracoronary Ca(2+) infusions were used to evaluate the contractile response (assessed by the left ventricular end-systolic elastance, E(es)) to added Ca(2+) of non-stunned myocardium and myocardium stunned by 15 min coronary artery occlusion and 30 min reperfusion. In non-stunned propranolol-treated myocardium, the Ca(2+) infusions doubled E(es) (baseline 6.9+/-0.9 mmHg mm(-2), n=8). Following Ca(2+)-washout, subsequent EMD 57033 infusion (0.1 mg kg(-1) min(-1), i.v.) tripled E(es) (P<0.05) and potentiated the Ca(2+)-induced increase in E(es) to 55.7+/-10.0 mmHg mm(-2) (P<0.05). Stunning (n=7) decreased E(es) to 5.3+/-0.6 mmHg mm(-2) (P>0.10) and attenuated the Ca(2+)-induced increase in E(es) (P<0.05). Subsequent infusion of EMD 57033 increased E(es) to 6.8+/-1.8 mmHg mm(-2) (P<0. 05) and restored responsiveness to added Ca(2+). These in vivo findings are consistent with the in vitro observations that myofilament Ca(2+)-responsiveness of stunned myocardium is reduced and that EMD 57033 increases contractility by enhancing myofilament Ca(2+)-responsiveness.

Animals↗

True 3-dimensional reconstruction of coronary arteries in patients by fusion of angiography and IVUS (ANGUS) and its quantitative validation.

BACKGROUND: True 3D reconstruction of coronary arteries in patients based on intravascular ultrasound (IVUS) may be achieved by fusing angiographic and IVUS information (ANGUS). The clinical applicability of ANGUS was tested, and its accuracy was evaluated quantitatively. METHODS AND REUSLTS: In 16 patients who were investigated 6 months after stent implantation, a sheath-based catheter was used to acquire IVUS images during an R-wave-triggered, motorized stepped pullback. First, a single set of end-diastolic biplane angiographic images documented the 3D location of the catheter at the beginning of pullback. From this set, the 3D pullback trajectory was predicted. Second, contours of the lumen or stent obtained from IVUS were fused with the 3D trajectory. Third, the angular rotation of the reconstruction was optimized by quantitative matching of the silhouettes of the 3D reconstruction with the actual biplane images. Reconstructions were obtained in 12 patients. The number of pullback steps, which determines the pullback length, closely agreed with the reconstructed path length (r=0.99). Geometric measurements in silhouette images of the 3D reconstructions showed high correlation (0.84 to 0.97) with corresponding measurements in the actual biplane angiographic images. CONCLUSIONS: With ANGUS, 3D reconstructions of coronary arteries can be successfully and accurately obtained in the majority of patients.

Coronary Angiography↗

Quantification of plaque volume, shear stress on the endothelium, and mechanical properties of the arterial wall with intravascular ultrasound imaging.

Present intravascular echographic imaging (IVUS) is based on either the mechanically rotated single element catheter or the multi-element phased array catheter principle. In both methods the ultrasonic beam is rotated through 360 degrees and the cross-sectional echo image of plaque and wall structures is visualised. A new development based on intravascular ultrasound is calculation of mechanical properties of the arterial wall. In this so-called elastographic approach, high frequency information obtained at identical positions in the arterial wall is compared under systolic and diastolic pressures. Minute shifts in the echo data indicate local compressibility. It thus becomes possible to indicate areas of high or low strain, which correspond to soft and hard material. Three-dimensional information can be obtained if the position of cross sectional slices is recorded with a pull-back device and slices are united into a 3D image. On the basis of such information it has become possible to view stents in 3D, and with interactive software, to calculate automatically plaque volume. With pull-back information only, the artery is reconstructed as a "straight pipe". Only when the biplane X-ray information is combined with the intravascular pull-back echo information can the true 3D reconstruction of the artery be constructed. Given the true geometric lumen information, it becomes possible, under certain assumptions, to derive the luminal fluid dynamics. From this, shear stress values close to the arterial wall can be calculated. Under the assumption that low values for local shear stress are areas prone to restenosis, predictions of endangered areas can be made.

Arteriosclerosis↗

Coronary stent implantation changes 3-D vessel geometry and 3-D shear stress distribution.

Mechanisms of in-stent restenosis are not fully understood. Shear stress is known to play a role in plaque and thrombus formation and is sensitive to changes in regional vessel geometry. Hence, we evaluated the regional changes in 3-D geometry and shear stress induced by stent placement in coronary arteries of pigs.Methods. 3-D reconstruction was performed, applying a combined angiographic and IVUS technique (ANGUS), from seven Wallstents (diameter 3.5 (n=3) and 5mm (n=4)), which were implanted in seven coronary arteries of five pigs. This 3-D geometry was used to calculate locally the curvature, while the shear stress distribution was obtained by computational fluid dynamics. Local changes in shear stress were obtained at the entrance and exit of the stent for baseline (0. 65+/-0.22 ml/s) and hyperemic flow (2.60+/-0.86 ml/s) conditions. Results. After stent implantation, the curvature increased by 121% at the entrance and by 100% at the exit of the stent, resulting in local changes in shear stress. In general, at the entrance of the stent local maxima in shear stress were generated, while at the exit both local maxima and minima in shear stress were observed (p<0.05). Additionally, the shear stress at the entrance and exit of the stent were correlated with the local curvature (r: 0.30-0.84).Conclusion. Stent implantation changes 3-D vessel geometry in such a way that regions with decreased and increased shear stress occur close to the stent edges. These changes might be related to the asymmetric patterns of in-stent restenosis.

Animals↗

Cardiovascular profile of the calcium sensitizer EMD 57033 in open-chest anaesthetized pigs with regionally stunned myocardium.

1. Ca(2+) sensitizers enhance systolic function, but may impair relaxation in vitro; these effects may differ in stunned and normal myocardium. We therefore studied the effect of EMD 57033 on systolic and diastolic function of normal and stunned porcine myocardium in vivo. 2. Myocardial stunning by 15 min coronary occlusion and 30 min reperfusion abolished systolic shortening (SS) (baseline 13+/-1%) and decreased end-systolic elastance (E(es)) from 67+/-7 to 47+/-5 mmHg mm(-1) (both P<0.05). Maximum rate of fall of myocardial elastance (dE/dt(min)) decreased from -850+/-100 to -320+/-30 mmHg mm(-1) s(-1), while the time constant tau(e) of the decay of elastance increased from 58+/-3 to 68+/-6 ms (both P<0.05). End-diastolic elastance (E(ed)) was unchanged although the zero pressure intercept (L(0,ed)) had increased. 3. In the stunned region, EMD 57033 (0.2 mg kg(-1) min(-1) for 60 min, i.v., n=7) increased SS to 19+/-2%, E(es) to 287+/-40 mmHg mm(-1), dE/dt(min) to -3630+/-640 mmHg mm(-1) s(-1) and decreased tau(e) to 50+/-3 ms, while E(ed) remained unchanged. In the normal region, 4. EMD 57033 increased SS from 14+/-2 to 18+/-3%, E(es) from 59+/-4 to 263+/-23 mmHg mm(-1), dE/dt(min) from -480+/-70 to -2280+/-700 mmHg mm(-1) s(-1) and decreased tau(e) from 91+/-12 to 61+/-3 ms (all P<0.05), while E(ed) remained unchanged. These responses were minimally affected by adrenoceptor blockade (n=7). Vehicle (n=7) had no effect on either region. EMD 57033 increased cardiac output (up to 27+/-8%) and LVdP/dt(max) (86+/-19%). Mean aortic pressure decreased (19+/-7%) due to systemic vasodilation that was not amenable to blockade of adrenoceptors or NO synthesis. 5. In conclusion, EMD 57033 restored systolic and diastolic function of stunned myocardium, and produced similar improvements in systolic and diastolic function in normal myocardium.

Anesthesia↗

Efficiency of energy transfer, but not external work, is maximized in stunned myocardium.

There is no evidence regarding the effect of stunning on maximization of regional myocardial external work (EW) or efficiency of energy transfer (EET) in relation to regional afterload (end-systolic stress, sigma(es)). To that end, we studied these relationships in both the left anterior descending coronary artery (LADCA) and left circumflex coronary artery regions in anesthetized, open-chest pigs before and after LADCA stunning. In normal myocardium, EET vs. sigma(es) was maximal at 75.4 (69.7-81.0)%, whereas EW vs. sigma(es) was submaximal at 12.0 (6.61-17.3) x 10(2) J/m(3). Increasing sigma(es) increased EW by 18 (10-27)%. Regional myocardial stunning decreased EET (27%) and EW (36%) and caused the myocardium to operate both at maximal EW (EW(max)) and at maximal EET (EET(max)). EET and EW became also more sensitive to changes in sigma(es). In the nonstunned region the situation remained unchanged. Combining the data from before and after stunning, both EW(max) and EET(max) displayed a positive relationship with contractility. In conclusion, the normal regional myocardium operated at maximal EET rather than at maximal EW. Therefore, additional EW could be recruited by increasing regional afterload. After myocardial stunning, the myocardium operated at both maximal EW and maximal EET, at the cost of increased afterload sensitivity. Contractility was a major determinant of this shift.

Analysis of Variance↗

Ca(2+) sensitization and diastolic function of normal and stunned porcine myocardium.

Ca(2+) sensitizers prolong myofibrillar force development in vitro and might therefore aggravate relaxation abnormalities of stunned myocardium. This is the first in vivo study of the effects of the thiadiazinone derivative EMD 60263 ((+)-5-(l-(alpha-ethylimino-3, 4-dimethoxybenzyl)-1,2,3,4-tetrahydroquinoline-6-yl)-6-methyl-3, 6-dihydro-2H-1,3,4-thiadiazine-2-on), a Ca(2+)-sensitizing agent with negligible phosphodiesterase III inhibitory activity, on diastolic function of regionally stunned myocardium. After producing stunning by two sequences of 10-min coronary artery occlusion and 30 min of reperfusion, anaesthetised pigs received either saline (n=7) or 1.5 and 3.0 mg/kg of EMD 60263 (n=8) or its enantiomer EMD 60264 (n=6), which lacks the Ca(2+)-sensitizing properties but shares the bradycardiac action via inhibition of the delayed inward rectifier K(+) current. In stunned myocardium, systolic shortening was reduced to 46+/-4% of baseline (P<0.05) and mean rate of half end-diastolic segment lengthening, an index for diastolic function, to 35+/-4%; systolic shortening and mean rate of half end-diastolic lengthening of remote normal myocardium remained unchanged. Saline did not affect these parameters in stunned or normal myocardium. EMD 60264 did not affect systolic shortening but decreased mean rate of half end-diastolic lengthening in normal myocardium to 61+/-8% and in stunned myocardium to 16+/-5% of baseline. During saline and EMD 60264, normal and stunned segments started to lengthen immediately after minimal segment length was reached (DeltaT=0). Low dose EMD 60263 restored systolic shortening of the stunned region with no effect on DeltaT. The high dose increased systolic shortening above baseline and DeltaT to 210+/-30 ms in both regions. Consequently, mean rate of half end-diastolic lengthening increased to 66+/-11% in stunned, while decreasing to 55+/-3% in normal myocardium. After elimination of bradycardia, DeltaT and hence mean rate of half end-diastolic lengthening recovered in stunned myocardium, but in normal myocardium the latter remained depressed because DeltaT persisted. In conclusion, both doses of EMD 60263 improved systolic as well as diastolic function of stunned myocardium. The high dose delayed relaxation of normal myocardium without adversely affecting systolic function.

3',5'-Cyclic-AMP Phosphodiesterases↗

Effect of catheter placement on 3-D velocity profiles in curved tubes resembling the human coronary system.

Novel measurement techniques based on intravenous ultrasound (IVUS) technology ('IVUS-Flowmetry') require the location of a catheter inside the coronary bed. The present study quantifies disturbances in the 3-D velocity profile induced by catheter placement inside a tube, applying computational fluid dynamics. Two curved, circular meshes (radius K = 0.025 m and K = 0.035 m) with and without a catheter inside the lumen were applied. The catheter was located at the inner curve, the outer curve and at the top position. Boundary conditions were: no slip on the wall, zero stress at the outlet, uniform inflow with entrance velocities of 0.1, 0.2 and 0.4 m/s. Curvature-associated centrifugal forces shifted the maximal velocity to the outer curve and introduced two symmetrical vortices. Additional catheter placement redistributed the 3-D axial velocity field away from the catheter, which was accompanied by the appearance of multiple low-strength vortices. In addition, peak axial velocity increased, peak secondary velocities decreased, axial pressure drop increased and shear stress increased. Flow calculations simulated to resemble IVUS-based flowmetry changed by only 1% after considering secondary velocity. In conclusion, placement of a catheter inside a curved tube resembling the human coronary system changes the velocity field and reduces secondary patterns. The present study supports the usefulness of catheter-based flowmetry during resting flow conditions. During hyperemic flow conditions, flow measurements might be accompanied by large axial pressure drops because the catheter, itself, might act as a significant stenosis.

Blood Flow Velocity↗

Decreased coronary flow reserve in hypertrophic cardiomyopathy is related to remodeling of the coronary microcirculation.

BACKGROUND: Ischemia occurs frequently in hypertrophic cardiomyopathy (HCM) without evidence of epicardial stenosis. This study evaluates the hypothesis that the occurrence of ischemia in HCM is related to remodeling of the coronary microcirculation. METHODS AND RESULTS: End-diastolic septal wall thickness was significantly increased in patients with HCM (25.8+/-2.9 mm) in comparison with cardiac transplant recipients (control subjects: 11.4+/-3.0 mm; P<0.05). Although the diameter of the left anterior descending coronary artery was similar in both groups (3.0+/-0.8 versus 3.0+/-0.5 mm, P=NS), the coronary resistance reserve (CRR=CRRbasal/CRRhyperemic), corrected for extravascular compression (end-diastolic left ventricular pressure), was reduced to 1.5+/-0.6 in HCM (P<.05; control, 2.6+/-0.8). Arteriolar lumen (AL) divided by wall area was lower in HCM (21+/-5% versus 30+/-4%; P<.05), and capillary density tended to decrease (from 1824+/-424 to 1445+/-513 per mm2, P=.11) in HCM. CRR was linearly related to normalized AL according to the formula CRR=O.1 AL-0.45 (r=.57; P<.05). Further analysis revealed that CRR, AL, and capillary density were all linearly related to the degree of hypertrophy. CONCLUSIONS: Decrements in CRR were related to changes of the coronary microcirculation. Both the decrease in CRR and these changes in the coronary microcirculation were related to the degree of hypertrophy. All these factors might contribute to the well-known occurrence of ischemia in this patient group.

Adult↗

AT1 receptor A/C1166 polymorphism contributes to cardiac hypertrophy in subjects with hypertrophic cardiomyopathy.

The development of left ventricular hypertrophy (LVH) in subjects with hypertrophic cardiomyopathy (HCM) is variable, suggesting a role for modifying factors such as angiotensin II. We investigated whether the angiotensin II type 1 receptor (AT1-R) A/C1166 polymorphism, the angiotensin-converting enzyme (ACE) insertion/deletion (I/D) polymorphism, and/or plasma renin influence LVH in HCM. Left ventricular mass index (LVMI) and interventricular septal thickness were determined by 2-dimensional echocardiography in 104 genetically independent subjects with HCM. Extent of hypertrophy was quantified by a point score (Wigle score). Plasma prorenin, renin, and ACE were measured by immunoradiometric or fluorometric assays, and ACE and AT1-R genotyping were performed by polymerase chain reactions. The ACE D allele did not affect any of the measured parameters except plasma ACE (P<0.04). LVMI was higher (P<0.05) in patients carrying the AT1-R C allele (190+/-8.3 g/m2) than in AA homozygotes (168+/-7.2 g/m2), and similar patterns were observed for interventricular septal thickness (23.0+/-0.7 versus 21. 6+/-0.7 mm) and Wigle score (7.0+/-0.3 versus 6.3+/-0.3). Plasma renin was higher (P=0.05) in carriers of the C allele than in AA homozygotes. Multivariate regression analysis, however, revealed no independent role for renin in the prediction of LVMI. Plasma prorenin and ACE were not affected by the AT1-R A/C1166 polymorphism, nor did the ACE and AT1-R polymorphisms interact with regard to any of the measured parameters. We conclude that the AT1-R C1166 allele modulates the phenotypic expression of hypertrophy in HCM, independently of plasma renin and the ACE I/D polymorphism.

Adult↗

Shear stress in atherosclerosis, and vascular remodelling.

Shear stress plays a role in lipid accumulation in primary atherosclerosis and vascular remodelling. We will present applications of a new technique, which enables to quantify shear stress in 3D vessel reconstructions. The method is based on 3D IVUS reconstructions of blood vessels either obtained by IVUS pull back (external iliac artery) or by a combination of angiography and IVUS (curved coronary artery). Distribution of wall thickness of a curved human right coronary artery was such that low wall thickness occurred where shear stress was high, and wall thickness was high where shear stress was low. Consequently, an inverse relationship between shear stress and wall thickness was detected. Although vascular remodelling after PTA in external iliac arteries of atherosclerotic Yucatan pigs was predicted both by acute gain and decrements in shear stress, the decrement in shear stress appeared a better predictor. In conclusion, shear stress appears to play a role in primary atherosclerosis and vascular remodelling after PTA.

Adaptation, Physiological↗

Cardiac depression after experimental air embolism in pigs: role of addition of a surface-active agent.

OBJECTIVE: Air bubbles entering the coronary artery may have harmful effects on cardiac function. From the physical point of view it is the relatively high surface tension of the blood-air interface which causes bubbles to trap in small vessels. The aim of the present study was to reduce depression of myocardial function from air embolism by lowering the surface tension of air bubbles. METHODS: The effect of using antifoam as a surface-tension-reducing agent on air bubble entrapment and cardiac function was investigated in 6 anesthetized pigs (27 +/- 1 kg) and analyzed using a two-compartment diffusion model. Air bubbles with a diameter of 150 microns were selectively injected into the left anterior descending coronary artery (LADCA) in a carrying fluid in the presence or absence of antifoam. Myocardial systolic segment shortening in the LADCA region (SS-LADCA) was measured by sonomicrometry. Presence of emboli was detected by measuring the amount of reverberation of ultrasound scattered by trapped air bubbles. RESULTS: SS-LADCA transiently decreased after injections of air bubbles in both the absence and presence of antifoam. However, in the presence of antifoam the regional depression recovered to normal sooner, the average depth of the depression was reduced, and bubbles from the embolized area cleared faster. These observations can be explained by a model derived from Laplace's law.

Animals↗