B-flow and B-flow with 3D and SRI postprocessing before intervention and monitoring after stenting of the internal carotid artery.

OBJECTIVE: To investigate the extent to which B-flow and B-flow with 3D postprocessing and speckle reduction imaging (SRI) have advantages in appraising the morphology of a high-grade stenosis of the internal carotid artery (ICA) for preinterventional planning and for postinterventional ultrasonographic follow-up. MATERIALS/METHODS: A comparative appraisal of flow with CCDS, power Doppler, B-flow and 3D B-Flow with SRI were carried out prospectively in 50 patients with >70% stenosis according to NASCET criteria in contrast medium-enhanced MRA before and after the intervention. After stenting of the internal carotid artery (ICA), i.a. digital substraction angiography (DSA) served as an additional reference method. RESULTS: In >70% ICA stenosis, simultaneous imaging of the pre-stenotic, intra-stenotic and post-stenotic flow was attained with B-flow in 45/90 cases (90%), with power Doppler in 39/50 cases (78%) and with CCDS in only 31/50 cases (62%). After intervention, a complete detection of flow without overwriting or blooming artifacts was achieved in all 50 patients only by B-flow. The intrastenotic flow (p<0.05) could be better demarcated against the lumen and the vessel wall before the intervention, whereas the flow within the stent could be very much better appraised after the intervention (p<0.01) using 3D postprocessing of B-flow with additional SRI. Re-stenoses with hypoechoic vascular wall changes (3/50 patients) were detected at an early stage using B-flow. CONCLUSIONS: B-flow technique with SRI and 3D postprocessing can facilitate the intrastenotic detection of flow in >70% ICA stenosis with fewer flow artifacts. After stenting, the perfused vascular lumen shows less flow artifacts compared with CCDS and power Doppler. In order to elucidate hemodynamic changes, additional Doppler examinations are still necessary.

Aged↗

Color Doppler, power Doppler and B-flow ultrasound in the assessment of ICA stenosis: Comparison with 64-MD-CT angiography.

The purpose of this study is to investigate the diagnostic potential of color-coded Doppler sonography (CCDS), power-Doppler (PD) and B-flow ultrasound in assessing the degree of extracranial internal carotid artery (ICA) stenosis in comparison to CT-angiography (MD-CTA). Thirty-two consecutive patients referred for CTA with 41 ICA-stenoses were included in this prospective study. MD-CTA was performed using a 64 row scanner with a CTDIvol of 13.1 mGy/cm. In CTA, CCDS, PD and B-flow, the degree of stenosis was evaluated by the minimal intrastenotic diameter in comparison to the poststenotic diameter. Two radiologists performed a quantitative evaluation of the stenoses in consensus blinded to the results of ultrasound. These were correlated to CTA, CCDS, PD and B-flow, intraoperative findings and clinical follow-up. Grading of the stenoses in B-flow ultrasound outperformed the other techniques in terms of accuracy with a correlation coefficient to CTA of 0.88, while PD and CCDS measurements yield coefficients of 0.74 and 0.70. Bland-Altman analysis additionally shows a very little bias of the three US methods between 0.5 and 3.2 %. There is excellent correlation (coefficient 0.88, CI 0.77-0.93) with 64-MD-CTA and B-flow ultrasound in terms of accuracy for intrastenotic and poststenotic diameter. Duplex sonography is useful for screening purposes.

Aged↗

Value of tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) in detection and characterisation of breast tumours.

The purpose of this study was to investigate the extent to which tissue harmonic imaging (THI), speckle reduction imaging (SRI), spatial compounding (SC) and contrast can improve detection and differentiation of breast tumours. We examined 38 patients (14 benign, 24 malignant tumours) with different combinations of THI, SRI and SC. The effect on delineation, margin, tissue differentiation and posttumoral phenomena was evaluated with a three-point score. Additionally, 1oo not palpable tumours (diameters: 4-15 mm) were examined by contrast harmonic imaging (CHI) with power Doppler. After bolus injection (0.5 ml Optison), vascularisation and enhancement were observed for 20 min. The best combination for detection of margin, infiltration, echo pattern and posterior lesion boundary was the combination of SRI level 2 with SC low. THI was helpful for lesions OF more than 1 cm depth. In native Power Doppler, vessels were found in 54 of 100 lesions. Within 5 min after contrast medium (CM) injection, marginal and penetrating vessels increased in benign and malignant tumours and central vessels mostly in carcinomas (p<0.05). A diffuse CM accumulation was observed up to 20 min after injection in malignant tumours only (p<0.05). THI, SRI and SC improved delineation and tissue differentiation. Second-generation contrast agent allowed detection of tumour vascularisation with prolonged enhancement.

Adult↗

Diagnostics and characterisation of preocclusive stenoses and occlusions of the internal carotid artery with B-flow.

The purpose was to evaluate whether B-flow can improve the ultrasonographic diagnosis of preocclusive stenosis and occlusion of the internal carotid artery (ICA) compared with colour-coded Doppler and power Doppler. Ninety patients with occlusions or preocclusive stenoses of the ICA suspected by Doppler sonography were examined with B-flow in comparison with colour-coded Doppler sonography (CCDS), power Doppler (PD) and intra-arterial digital subtraction angiography (DSA). Intrastenotic flow detection and lengths of stenoses were the main criteria. Ulcerated plaques found by surgery in 42/90 patients were compared by ultrasonography (US). Diagnosis of ICA occlusion with CCDS, PD and B-flow was correct in all 42 cases. A preocclusive ICA stenosis in DSA was detected correctly in all 48/48 cases (100%) for B-flow, in 44/48 (92%) for PD and in 39/48 (81%) for CCDS. Surgical findings showed in 17/42 cases ulcerated plaques; 15/17 (89%) of these cases were detected with B-flow, 12/17 (71%) with PD, 10/17 (59%) with CCDS, and 8/17 (47%) with DSA. With B-flow the extent of stenosis was appraised more precisely than with PD and CCDS (P<0.0001). In conclusion, B-flow is a reliable method for preocclusive stenosis of the ICA with less intrastenotic flow artefacts. B-flow facilitates the characterization of plaque morphologies.

Aged↗

[Ultrasound diagnosis of vascular complications following transfemoral puncture].

Percutaneous catheter interventions are performed increasingly often for the purposes of both diagnosis and therapy. The incidence of local complications reported after transfemoral catheterization in the literature is 0.1-9%. Such complications should be detected as early and reliably as possible, and sonography is a good means of finding them during follow-up, not least because it is suitable for use in examinations at the bedside. The clinical value of sonography compared with other examination techniques is made clear with reference to specimen cases.

Catheterization, Peripheral↗

[Digital ultrasonic diagnosis of lower leg venous thrombosis using harmonic imaging and cross beam technology].

PURPOSE: To evaluate the extent to which Tissue Harmonic Imaging (THI) and spatial averaging (Sono-CT, Cross Beam) facilitate the diagnosis of lower leg venous thrombosis. MATERIALS AND METHODS: In 100 cases of lower leg venous thrombosis, the conventional B-scan, THI, and ultrasonic CT technology (Cross Beam) in examinations using a multi-frequency transducer head (9 - 14 MHz, Logiq 9, GE) were compared during follow-up studies using compression sonography over at least 6 weeks. Two independent examiners performed digital image documentation (PACS connection) without modifying the gray level parameters optimized in the B-scan. A thrombosis was considered to be proven sonographically if at least one ultrasonic modality yielded findings reproducible in follow-up checks at a comparable site in accordance with both examiners. RESULTS: Thromboses in the V. tibialis posterior category (97 %) and the fibular category (81 %) were found most often, followed by muscular venous thromboses (48 %). Thromboses in the V. tibialis anterior category were rare (12 %). The procedure comparison showed an advantage for ultrasonic CT technology in terms of the demarcation of thromboses of the deeper veins (sensitivity 98 %), as compared to THI (sensitivity 87 %, specificity 91 %, PPV: 99 %) and the B-scan (sensitivity 81 %). CONCLUSION: If a high-resolution linear transducer is used, THI and ultrasonic CT-Technology can facilitate the diagnosis of a lower leg venous thrombosis.

Adult↗

Vascularization of liver tumors - preliminary results with Coded Harmonic Angio (CHA), phase inversion imaging, 3D power Doppler and contrast medium-enhanced B-flow with second generation contrast agent (Optison).

PURPOSE: To investigate the dynamic value of contrast medium-enhanced ultrasonography with Optison for appraisal of the vascularization of hepatic tumors using harmonic imaging, 3D-/power Doppler and B-flow. MATERIALS/METHODS: 60 patients with a mean age of 56 years (range 35-76 years) with 93 liver tumors, including histopathologically proven hepatocellular carcinoma (HCC) [15 cases with 20 lesions], liver metastases of colorectal tumors [17 cases with 33 lesions], metastases of breast cancer [10 cases with 21 lesions] and hemangiomas [10 cases with 19 lesions] were prospectively investigated by means of multislice CT as well as native and contrast medium-enhanced ultrasound using a multifrequency transducer (2.5-4 MHz, Logig 9, GE). B scan was performed with additional color and power Doppler, followed by a bolus injection of 0.5 ml Optison. Tumor vascularization was evaluated with coded harmonic angio (CHA), pulse inversion imaging with power Doppler, 3D power Doppler and in the late phase (>5 min) with B-flow. In 15 cases with HCC, i.a. DSA was performed in addition. The results were also correlated with MRT and histological findings. RESULTS: Compared to spiral-CT/MRT, only 72/93 (77%) of the lesions could be detected in the B scan, 75/93 (81%) with CHA and 93/93 (100%) in the pulse inversion mode. Tumor vascularization was detectable in 43/93 (46%) of lesions with native power Doppler, in 75/93 (81%) of lesions after administering contrast medium in the CHA mode, in 81/93 (87%) of lesions in the pulse inversion mode with power Doppler and in 77/93 (83%) of lesions with contrast-enhanced B-flow. Early arterial and capillary perfusion was best detected with CHA, particularly in 20/20 (100%) of the HCC lesions, allowing a 3D reconstruction. 3D power Doppler was especially useful in investigating the tumor margins. Up to 20 min after contrast medium injection, B-flow was capable of detecting increased metastatic tumor vascularization in 42/54 (78%) of cases and intratumoral perfusion in 17/20 (85%) of HCC cases. All 19 hemangiomas were correctly classified by phase inversion imaging. CONCLUSIONS: Contrast medium-enhanced ultrasound investigation of liver tumors with Optison allowed reliable detection of tumor foci and, in most cases, appraisal of tumor vascularization. The time available for evaluation of tumor margin vascularization was substantially longer in B-flow.

Adult↗

[Significance of Doppler ultrasound procedures for diagnosis of carotid stenoses].

Determining degree and morphology of stenoses is important for surgical planning or stent implantation. Vascular ultrasound is usually the first modality to evaluate carotid artery stenosis. Due to rapid development various methods of vascular ultrasound are applied including continuous wave (CW) Doppler, duplex Doppler, colour-coded duplex sonography (CCDS), power Doppler and B-flow technique. For quantitative assessment of the degree of stenosis the most frequently used parameters are peak systolic velocity (PSV), end-diastolic velocity (EDV) in the internal carotid artery (ICA), as well as ICA to CCA ratios of PSV and EDV. Different results reported in the literature may reflect differences in defining the degree of stenosis and methodological differences in protocol or imaging techniques. Differences in defining the degree of stenosis, advantages and disadvantages of the different Doppler techniques and future developments are discussed in detail.

Carotid Artery, Internal↗

[Differential echogenic focal splenic lesion diagnosis].

Echogenic focal lesions of the spleen are rare. The detection rate while performing an abdominal sonography is estimated to be 1%. When found, the examiner is confronted with a differential diagnostic problem. A final diagnosis can not be drawn from a single imaging modality. Gathering the clinical information or follow-up examinations often result in a correct diagnosis. Haemangioma of the spleen is the most common benign lesion. On the other hand, while having a malign disease the most common diagnosis is metastases, however in about 30% of the cases one can find benign lesions.

Adult↗

[Improved evaluation of stenoses of hemodialysis fistulas by B-flow ultrasound].

PURPOSE: To evaluate the new technique of B-flow ultrasound in assessing stenoses of hemodialysis fistulas. MATERIALS AND METHODS: 50 patients (mean age 58 years) with Brescia-Cimino-Shunts (27 shunts of the radial and 23 of the cubital artery) were prospectively assessed with intraarterial DSA and vascular ultrasound by independent examiners. Eligibility for the study was a shunt-volume of less than 400 ml/min and an angiographically suspected hemodynamically significant stenosis of the anastomosis or of shunt veins. Sonography was performed with a multifrequency ultrasound probe (5 to 10 MHz, Logic 700, GE) using B-mode, color coded Doppler sonography (CCDS) and B-flow technique. RESULTS: Anastomotic stenosis and stenosis of the shunt veins were equally distributed, found in 25 patients each. The measurements of the residual lumen of the 25 anastomotic stenoses were 1.47 to 3.43 mm (average: 2.3 mm) for intraarterial DSA, 1.57 to 3.73 mm (average: 2.6 mm) for B-mode ultrasound, 1.97 to 4.17 mm (average: 2.9 mm) for CCDS, 1.43 to 3.47 mm (average: 2.3 mm) for B-flow technique in the brightness mode and 1.6 to 3.47 mm (average: 2.4 mm) for B-flow technique in the B-mode. The brightness mode of the B-flow correlated best with intraarterial DSA (r=0.994), with a significantly lower correlation between CCDS and intraarterial DSA. B-flow displays less vascular distortion within the stenosis and fewer flow artifacts. Even in angulated stenoses, the detected intra- and poststenotic flow was markedly less angle-dependent in comparison with CCDS. B-flow clearly facilitates the visualization of hypoechoic plaques and intima proliferation. Furthermore, eccentric cicatricial stenoses, intima flaps or hypoechoic thrombi, which were not seen with DSA or B-mode, showed improved visualization in comparison with CCDS. CONCLUSION: Ultrasound B-flow makes it easier to assess the morphology and the local degree of stenotic hemodialysis fistulas. Flow detection is achieved with fewer artifacts and reduced angle dependence. This opens the way for better planning of interventional therapy.

Aged↗

[B-flow and contrast medium-enhanced power Doppler (Optison(R))--preoperative diagnosis of high-grade stenosis of the internal carotid artery].

PURPOSE: To improve sonographic diagnosis of high-grade stenosis of the internal carotid artery (ICA) by vascular sonography in "B-flow"-mode and in contrast medium (Optison(R))-enhanced power Doppler (PD). MATERIAL AND METHODS: 88 patients suspected of a high-grade stenosis of the extracranial ICA were examined by independent examiners with color-coded Doppler (CCD), B-flow and PD to compare the methods for morphology and degree of stenosis. In 21 cases contrast medium was used in PD. Sonographic results of all 88 patients were compared with selective angiography (DSA), in 53 cases with operative findings. RESULTS: A complete occlusion was found in 9 patients and a 50 - 70 % degree non-exulcerated stenosis in 26 cases. 53 of 88 patients presented findings in both sonography and DSA leading to operation of the ICA. Among these 47 had a stenosis > 70 % and 6 a stenosis of 60 - 70 % with exulcerated plaques. Even a small dose of contrast medium (0.3 ml) gave a significant signal increase in PD improving flow detection even in extensive vascular calcification. In both the early phase (up to the first minute p. i.) flow contrast was optimal and without significant artifacts. Thus, the extent and the morphology of the stenosis was better appreciated. Hypoechogenic plaques, ulcerations and thrombi are as easily recognized by B-flow as flow in preocclusive stenosis, free of vibration and blooming artifacts. This gave a better correlation with DSA and a higher diagnostic accuracy in grading a stenosis than CCD and PD. Circular calcifications or vessel kinking made diagnosis of flow more difficult. CONCLUSION: B-flow allows a reliable diagnosis of the degree of stenosis of ICA and a better appreciation of plaque morphology than CCD. In some cases with extensive calcifications contrast medium-enhanced PD is able to detect better intrastenotic flow. Only small quantities of contrast medium (Optison(R)) are required.

Aged↗

Color Doppler imaging assessment of blood flow in vascularized pedicle grafts for avascular necrosis of the femoral head: angiographic correlation.

The aim of this study was to examine whether color Doppler imaging can be used to assess vascular patency after use of pedicle pelvic bone grafts in the operative treatment of avascular necrosis of the femoral head. We performed color Doppler imaging and selective angiography in 10 consecutive patients (12 hip joints) treated for avascular necrosis of the femoral head. In comparison to angiographic results, nine patent and two occluded grafts were demonstrated correctly by color Doppler imaging. In one case, a graft confirmed as patent by angiography was not demonstrable by color Doppler imaging. Accuracy, sensitivity, and specificity of color Doppler imaging were high when compared to angiography as a standard. Color Doppler imaging is suited to evaluate vascular patency after use of vascularized pedicle bone grafts in the treatment of avascular necrosis of the femoral head.

Angiography↗

[Percutaneous embolization therapy in severe cervicofacial hemorrhages].

PURPOSE: To analyse the use of transcatheter embolisation. MATERIAL AND METHODS: We report on 43 patients treated by transcatheter embolisation for head and neck haemorrhage from 1987 to 1995. There were 13 patients with idiopathic intractable epistaxis, 6 with iatrogenic and three with traumatic bleeding, 7 patients with bleeding from vascular malformations, 12 patients with haemorrhage from tumours, one ruptured aneurysm of the inferior thyroid artery and one patient bleeding from a retrolingual dystrophic goitre. RESULTS: In 11/13 patients with idiopathic epistaxis, this could be stopped. In 8/9 of the traumatic and iatrogenic bleedings the haemorrhage was treated by embolisation alone. In two cases additional elective surgical interventions were necessary. In 6/7 patients with vascular malformations embolisation resulted in long-lasting periods free from bleeding. Palliative embolisation in bleeding tumours resulted in haemostasis in 10/12 patients. Bleeding was definitely stopped in a patient with aneurysm of the inferior thyroidal artery as well as in a patient with bleeding from a dystrophic goitre. We observed a total of three complications, two transitory neurological disturbances and one permanent amaurosis. CONCLUSION: Transcatheter embolisation is an effective tool in the treatment of life-threatening head and neck bleedings.

Acute Disease↗

Noninvasive method for measuring thrombus formation in patients after peripheral angioplasty using three-dimensional B-mode and color-coded Doppler ultrasonography.

Clinical investigations studying the effect of newer medications on such complex pathophysiology as the formation of an arterial or venous mural thrombus have been limited to clinical symptomatic endpoints. Biochemical markers so far have not been convincing in quantifying ongoing thrombus formation. Consequently, clinical development of new antithrombotic compounds has had to rely on clinical symptoms that occur either comparably late in the course of the disease and may therefore be influenced by many other factors, or on those symptoms that occur at a relatively low incidence rate. Both circumstances make studies for dose-finding and determination of optimal drug regimens more difficult and time consuming. Using conventional clinical noninvasive ultrasonography, the volume and geometry of a peripheral arterial segment can be measured with high sensitivity and reproducibility in healthy volunteers (% coefficient of variation = 8.01%). In patients, thrombus volume was monitored after peripheral transluminal angioplasty of the femoral artery. All patients received a standard anticoagulant treatment with heparin for 24 hours after the procedure. Volume measurements were performed at 20, 29, 44, 53, and 68 hours after angioplasty. When compared with the obstruction volume at 20 hours, a slight increase could be detected at 29, 44, and 53 hours. At 68 hours there was a significant increase in obstruction volume. This indicates that volume measurements may detect changes in the course of thrombus formation, related to the antithrombotic treatment regimen, at a level at which clinical symptoms may not be present.

Aged↗

Rapid course radiation therapy vs. more standard treatment: a randomized trial for bone metastases.

PURPOSE: In a prospective randomized trial we examined whether radiotherapy of painful bone metastases can be shortened using larger single doses without impairing effectivity. METHODS AND MATERIALS: One hundred patients with painful bone metastases having no prior surgical intervention or treatment with x-ray therapy and had a median follow-up of 12 months were analyzed. The primary tumor was located in the breast in 43%, in the lung in 24%, and in the prostate in 14%. The most frequent sites of metastases were the pelvis (31%), the vertebral column (30%), and the ribs (20%). Further percentages of sites were: lower extremity 11%, upper extremity 6%, and skull 2%. Fifty-one patients received a short course radiotherapy with a total dose of 20 Gy in 1 week (daily dose 4 Gy), and 49 patients received 30 Gy in 3 weeks (daily dose 2 Gy). RESULTS: There were no significant differences in frequency, duration of pain relief, improvement of mobility, recalcification, frequency of pathologic fractures nor survival. There was a light trend favoring 30 Gy in frequency of pain relief and recalcification. Survival was mostly influenced by primary tumor site, Karnofsky performance status, and possibly by the response to radiotherapy (pain relief). CONCLUSIONS: Because of the very short life expectancy of patients with metastatic bone disease, we now use 20 Gy in 1 week as our standard to reduce hospital stay.

Adult↗

[Arterioportal fistulas in the extra-hepatic circulation of the common hepatic artery. Diagnosis and radiologic interventional therapy].

Two cases of arterioportal fistulas and new possibilities in diagnosis and treatment are reported: A 62-year-old women was admitted to our hospital with abdominal pain. Color flow duplex sonography showed an arterioportal fistula between the proper hepatic artery and the ectatic portal vein that was confirmed by angiography, permitting percutaneous embolization as a definitive treatment. The pain disappeared immediately. A 36-year-old man underwent surgery due to a penetrating gastric ulcer. He was referred to us with an abdominal murmur. Color flow duplex sonography proved by spiral CT with 3D reconstruction and maximum intensity projection (angio-CT) revealed an arteriovenous fistula between the gastroduodenal artery and a mesenteric branch. Angiography confirmed the diagnosis and permitted definitive therapeutic embolization.

Adult↗

[Radiation exposure in abdominal radiography with digital luminescence radiography and conventional screen-film system: an experimental animal study].

PURPOSE: To determine and compare the minimum required radiation exposure for a.-p. abdominal radiographs with digital luminescence radiography (DLR) and a screen-film system (SFS) providing adequate image quality in clinical routine. MATERIAL AND METHOD: Abdominal radiographs a.-p. of a pig were produced with DLR and SFS systematically varying the tube current-time product. The image quality was assessed by eight experienced radiologists according to the criteria of visual resolution, mean optical density, perceptibility of the lateral edge of the psoas, the caudal edge of the liver, bone structures and intestinal wall. RESULTS: The image quality of the digital radiographs was better for each criterion except visual resolution if the same current-time product was used for both techniques. From the minimum tube current-time products providing an adequate image quality it follows that a dose reduction of 57% can be achieved by applying DLR instead of speed class 200 SFS. CONCLUSION: The recently published guide-lines for quality assurance in x-ray diagnostics issued by the German Federal Board of Physicians recommend using speed class 400 SFS. Since in that case an approximately halved radiation dose is necessary, dose reduction is hardly to be expected with DLR.