PubMed Health⌕ Search

Biomedical subjects

R L Berger

Publications and source records attributed to R L Berger.

At least 73 records · Page 4Linked to original sources

Variability of oxygen affinity of blood: human subjects native to high altitude.

Whole blood O2 equilibrium curves (OEC) were measured in 46 Peruvians native to high altitude (4,540 m) and in 25 sea-level controls. A method was employed that records the entire OEC from 0 to 150 Torr with constant pH and PCO2. The data were analyzed by fitting the Adair equation describing the successive oxygenation of hemoglobin. At pH 7.4 the PO2 at which hemoglobin is half-saturated with O2 (P50) was significantly higher in the high-altitude population (31.2 +/- 1.9 Torr) than in controls (29.2 +/- 1.8 Torr, P less than 0.001). The acid-base status of the high-altitude subjects, however, was that of compensated respiratory alkalosis (plasma pH 7.439 +/- 0.065), and when the P50's were corrected to the subjects' plasma pH the values (30.1 +/- 2.2 Torr) could no longer be distinguished from the controls. We conclude that, on the average, increased P50 resulting from increased red cell 2,3-diphosphyoglycerate concentration at high altitude is offset by compensated respiratory alkalosis with the net result that the position of the OEC more closely approaches that of sea-level humans than has hitherto been thought. Considerable variation exists in P50, both at sea level and high altitude. This variation might have important consequences for acclimatization and survival under adverse environmental conditions.

2,3-Diphosphoglycerate↗

Preservation of the myocardium during coronary artery bypass grafting.

The influence of three methods of myocardial preservation used during coronary artery bypass grafting on operative mortality and perioperative myocardial infarction was evaluated in seven institutions participating in the Coronary Artery Surgery Study (CASS). Both operative mortality and perioperative infarctions were comparable with either normothermic and topical hypothermic myocardial preservation. The addition of potassium cardioplegia to hypothermia lowered both operative mortality and perioperative myocardial infarction (p less than 0.01 and p less than 0.001, respectively). Stepwise multivariate discriminant analysis revealed that the high-risk clinical and angiographic variables were the most important determinants of operative mortality, followed by surgical priority and the use of potassium cardioplegia. However, none of the clinical, angiographic and surgical variables other than the use of potassium cardioplegia influenced the incidence of perioperative myocardial infarction.

Adult↗

Infection in remnant of left ventricular assist device after successful separation from assisted circulation.

There have been two long-term and two short-term survivors among 10 patients in our hospital in whom the left ventricular assist device (LVAD) was implanted for cardiogenic shock after cardiac operations. Two of these four patients developed graft infection in the LVAD remnants left attached to the ascending aorta and left ventricle; one died of sepsis and the other required repeat operations for a chronic draining sinus and hemorrhage from a left ventricular--cutaneous fistula. This experience with infection and demonstration of the feasibility of total removal of both limbs of the LVAD without cardiopulmonary bypass lead us to recommend complete removal of the LVAD conduits in patients weaned from assisted circulation.

Aorta↗

Successful use of a paracorporeal left ventricular assist device in man.

A paracorporeal left ventricular assist device (LVAD) with a capacity to pump 8 L/min of blood was employed in a clinical trial, and this report details the first survivor. A 60-year-old man could not be separated from the pump oxygenator following coronary artery bypass grafting, and, therefore, an LVAD was employed. Almost the entire left ventricular workload was assumed by the mechanical pump so that the myocardium was allowed to rest and recover. The LVAD support was continued for 105 hours. It provided satisfactory total body perfusion with maintenance of good hemodynamics--without serious deleterious effects on hematologic factors. The patient is alive and active without cardiac symptoms 16 months after his operation. The total experience with 13 LVAD implantations warrants continuation of the clinical trials in selected patients.

Angina Pectoris↗

Improved oxygen delivery to the myocardium during hypothermia by perfusion with 2,3 DPG-enriched red blood cells.

The oxygen affinity of red cells increases stepwise with temperature reductions below 37 degrees C. In vitro studies demonstrated that biochemically modified red cells with increased 2,3 diphosphoglycerate (2,3 DPG) (150% and 250% of normal) exhibited significantly less oxygen affinity at 24 degrees C than did unmodified cells. At 15 degrees C, significant attenuation of affinity was observed with 250%, but not 150%, of normal 2,3 DPG cells. Measurements made of isolated fibrillating dog hearts during perfusion at 24 degrees C alternately with unmodified (80% of normal 2,3 DPG) and modified (300% of normal 2,3 DPG) red cells demonstrated significantly greater oxygen consumption, higher coronary sinus partial pressures of oxygen and carbon dioxide, higher in vitro P50 values, and lower arterial and coronary sinus lactate levels during perfusion with modified as compared with unmodified cells. This evidence, indicating improved oxygen delivery to hypothermic dog hearts by red cells with 300% of normal 2,3 DPG activity, suggests that high 2,3 DPG cells might protect myocardial tissue in patients undergoing hypothermic cardiac operation.

Animals↗

Sequential radionuclide imaging during paracorporeal left ventricular support.

A paracorporeal left ventricular to ascending aorta assist device (LVAD) was utilized in four patients with refractory cardiogenic shock following cardiac surgery. Hemodynamic stabilization was achieved in all four patients, two of whom were subsequently discharged from the hospital and continue to do well one year later. A technique is described for obtaining radionuclide ejection fractions (EFs) during temporary LVAD interruption. The EFs appeared to be predictive of eventual unassisted ventricular function and possibly of patient survival.

Adult↗

A digitally linearized thermistor thermometer referenced to IPTS-68.

We describe a digitally linearized thermistor thermometer that is accurate to +/- 0.01 degrees C from 0 to 60 degrees C at a wattage of 50 microW and a sampling time of 1 s. It is traceable to the International Practical Temperature Scale of 1968 (IPTS-68). Analog and digital outputs are provided, the latter as ASCII RS-232C. The thermistor is a 10-cm long immersible probe, 1.5 mm in diameter. Only 0.5 cm of the probe need be immersed, with proper heat sinking of at least 1 cm of the remaining 9.5 cm, for accurate readings. Error from self-heating of the thermistor is less than 5X 10(-3) degrees C at all power settings from 50 to 1 microW.

Autoanalysis↗

Left ventricular false aneurysm after coronary bypass surgery: radionuclide diagnosis and surgical resection.

A patient with left ventricular pseudoaneurysm formation resulting from myocardial infarction 4 years after coronary bypass surgery is described. The pseudoaneurysm was diagnosed with gated cardiac blood pool imaging and was subsequently successfully surgically repaired. Postoperative pericardial abnormalities predisposing to the possible development of a false aneurysm are discussed. Also, clinical situations in which pseudoaneurysm should be suspected are described, and appropriate diagnostic approaches are outlined.

Coronary Artery Bypass↗

Temporary left ventricular bypass: factors affecting patient survival.

Circulatory support (range, 2 hours-8 days) was undertaken in eight cardiac surgical patients (with two survivors) exhibiting intractable cardiogenic shock. A paracorporeal, pneumatic, xenograft-valve pump was interposed between the left ventricular apex and ascending aorta. Pumping lowered left atrial and ventricular pressure while maintaining cardiac output (1.8--2.6 l/min/m2). Following implantation, plasma hemoglobin and erythrocyte mechanical fragility values were elevated but decreased to normal when renal function was not impaired. Mild thrombocytopenia was noted in three patients and was severe in five others with persistent hemorrhage. Anticoagulation agents were used during tapering of pump flow (three patients) after 100, 105 and 120 hours of bypass. Otherwise, for the major portion of the interval of mechanical circulatory support, anticoagulants were not administered. Despite this fact, no systemic embolization was detected in any of the patients. It appears that assist pump support can be life-saving in acute left ventricular failure in patients following cardiac surgery.

Adult↗

Successful use of a left ventricular assist device in cardiogenic shock from massive postoperative myocardial infarction.

A 41-year-old man underwent an uneventful aorta-coronary bypass for unstable angina pectoris. Four hours later, a massive anterior wall myocardial infarction resulted in cardiac arrest. Conventional resuscitative means were not effective. A left ventricular assist device (LVAD) was successfully employed for 94 hours. The patient is alive and well 8 months postoperatively.

Adult↗

Simple method for measurement of cardiac output by thermodilution after cardiac operation.

Cardiac output by the thermodilution technique was measured by a new No. 2 Fr. transthoracic (2F-TT) thermistor catheter placed at cardiac operation into the pulmonary artery directly through the right ventricular outflow tract. Cold (0 degree C) 5% dextrose in water (D5W) was used as indicator and injected through a percutaneously placed central venous pressure (CVP) catheter in the jugular vein. Comparison to the No. 7 Fr. Swan-Ganz (7F-SG) catheter demonstrated a close correlation (r = 0.87) and almost identical mean thermodilution cardiac output values during 530 determinations in 10 patients. No difficulty was experienced in insertion or removal of the 2F-TT catheter and no bleeding complications were noted. Experiments in six dogs showed that variation in position of the tip of the CVP catheter within the superior vena caval venous system and right atrium was not a critical factor in measurement of thermodilution cardiac output. The thermodilution cardiac output technique in general and the ease of insertion, as well as the small size of the 2F-TT catheter, should make this method especially advantageous in infants and small children.

Cardiac Output↗

Management of penetrating heart wounds.

The records of ninety-two patients treated between 1965 and 1976 at the Boston City Hospital for penetrating wounds of the heart were reviewed and the results were compared with a previous series of twenty-five patients admitted to the same institution between 1956 and 1964. The annual incidence rose from 2.8 cases during the first period to 8.0 during the more recent years. Gunshot wounds increased in frequency in the second period. The overall mortality was similar in the two series. However, there were more complex wounds and agonal patients subjected to immediate emergency room thoracotomy during the second phase of this experience. The salvage rate in the latter group of patients gradually improved and averaged 24% between 1965 and 1976. These data indicate that an aggressive approach, including the use of immediate thoracotomy, to the agonal patient with a heart wound will be rewarded with salvage of some patients.

Adolescent↗

An appraisal of blood trauma and blood-prosthetic interface during left ventricular bypass in the calf and humans.

Mechanical circulatory support was accomplished in 20 calves (mean, 140 days) and in 5 patients following operation for acquired heart disease (range, 1 hour to 8 days) employing a pneumatically actuated xenograft-valved assist pump interposed between the left ventricular apex and aorta. Following pump implantation in calves, hematocrit and platelets decreased transiently and returned to normal within 14 days. Plasma hemoglobin and erythrocyte mechanical fragility values were elevated for 48 hours. Platelet survival was slightly reduced, but erythrocyte survival values were similar to controls. In patients who received assist pumps, plasma hemoglobin and erythrocyte mechanical fragility were transiently elevated, but rapidly decreased to normal. Thrombocytopenia occurred only in the presence of bleeding and renal failure requiring hemodialysis. Pump flow of the left ventricular assist device was maintained above 2.0 L/min/m2 despite serious arrhythmias. Postmortem examination revealed no evidence of thromboemboli in the clinical patients although anticoagulant agents were not administered.

Adult↗

A simplified plastic repair for aortic dissections.

A simplified plastic repair for aortic dissection is described. The operation consists of noncircumferential resection of the aortic segment containing the intimal tear, leaving the posterior wall intact. The false lumen is obliterated by oversewing both lips of the aortic incision. Aortic continuity is restored either by primary closure or by the insertion of a diamond-shaped prosthetic patch. The simplified plastic procedure shortens cardiopulmonary bypass time and reduces bleeding from suture lines. The operation was employed in 2 patients with success.

Aged↗

Transfusion of 2,3 DPG-enriched red blood cells to improve cardiac function.

Attempts were made to enhance oxygen availability in patients undergoing coronary artery bypass operations by transfusing red blood cells enriched in 2,3 diphosphoglycerate (2,3 DPG) to 150% of normal. In this study of 22 patients, 11 received red blood cells with high 2,3 DPG levels and 11 received red blood cells with 70% of normal 2,3 DPG levels (control). Immediately following cardiopulmonary bypass the 11 patients who received high 2,3 DPG red blood cells had a P50 value of 31.6 mm Hg; the value in control patients was 28.3 mm Hg (p less than 0.05). Oxygen consumption values were 135 and 106 ml/min/m2, respectively (p less than 0.05). Mixed venous oxygen tensions were similar in the two groups, but the arteriovenous content difference was higher in the high 2,3 DPG group (p less than 0.05). Cardiac indices increased significantly in response to a fluid load in the high 2,3 DPG group compared with controls at comparable filling pressures. We believe the improved myocardial performance in response to a fluid challenge is a result of increased oxygen availability.

Blood Transfusion↗