A prospective approach to correct for inter-image head rotation in fMRI.

Global head motion occurring between successive image acquisitions during a functional MRI time series can corrupt the signal of physiologic brain activation, potentially invalidating interpretation of the final activation map from that particular fMRI time series. By approximating the head as a rigid body, multiaxial global head motion can be decomposed into orthogonal linear and rotational components. This paper describes a method using orbital navigator echoes to provide prospective correction for both through-plane and in-plane inter-image head rotation in functional MRI. The dynamic detection and correction of rotation can be performed in <100 ms. Phantom experiments demonstrate accurate correction of rotational motion over a range of +/-0.36 degrees to +/-12 degrees. Imaging studies in volunteers document the feasibility of real-time prospective correction of rotational motion in vivo. Using a modified receiver operating characteristic method, motion-corrected functional MRI sensorimotor studies incorporating deliberate head rotations are shown to be superior to functional MRI time series acquired under similar conditions but without motion correction.

Artifacts

Peroneal tendon injuries.

Injury to the peroneal tendons is a frequently overlooked cause of persistent lateral ankle pain after trauma. Peroneal tendon anatomy, biomechanics, diagnostic studies, and traumatic disorders were reviewed.

Adult

Infraclavicular brachial plexus block: parasagittal anatomy important to the coracoid technique.

UNLABELLED: Infraclavicular brachial plexus block is a technique well suited to prolonged continuous catheter use. We used a coracoid approach to this block to create an easily understood technique. We reviewed the magnetic resonance images of the brachial plexus from 20 male and 20 female patients. Using scout films, the parasagittal section 2 cm medial to the coracoid process was identified. Along this oblique section, we located a point approximately 2 cm caudad to the coracoid process on the skin of the anterior chest wall. From this point, we determined simulated needle direction to contact the neurovascular bundle and measured depth. At the skin entry site, the direct posterior insertion of a needle will make contact with the cords of the brachial plexus where they surround the second part of the axillary artery in all images. The mean (range) distance (depth along the needle shaft) from the skin to the anterior wall of the axillary artery was 4.24 +/- 1.49 cm (2.25-7.75 cm) in men and 4.01 +/- 1.29 cm (2.25-6.5 cm) in women. Hopefully, this study will facilitate the use of this block. IMPLICATIONS: We sought a consistent, palpable landmark for facilitation of the infraclavicular brachial plexus block. We used magnetic resonance images of the brachial plexus to determine the depth and needle orientation needed to contact the brachial plexus. Hopefully, this study will facilitate the use of this block.

Adult

Fluoroscopically triggered contrast-enhanced three-dimensional MR angiography with elliptical centric view order: application to the renal arteries.

PURPOSE: To determine the reliability of obtaining arterial-phase, contrast-material-enhanced three-dimensional (3D) magnetic resonance (MR) angiograms of the renal arteries by using a technique that combines two-dimensional real-time MR fluoroscopy and a 3D MR angiographic acquisition with elliptical centric view order. MATERIALS AND METHODS: Twenty-five consecutive patients suspected of having renal artery disease were evaluated with the fluoroscopically triggered technique by using a mean dose of 0.18 mmol/kg gadoteridol. Left renal vein suppression, inferior vena cava suppression, motion artifact, and image quality for depiction of the renal arteries were each evaluated on a five-point scale (1 = best). The findings were compared with those of another 25 consecutive patients who underwent conventional gadolinium-enhanced 3D MR angiography. RESULTS: The fluoroscopically triggered technique produced 4.6 times less left renal vein enhancement than did the conventional method (P < .01). With the fluoroscopically triggered technique, visualization of the renal arteries was adequate for diagnosis in 24 patients (96%) and the overall result (score of 1-3 for all criteria) was of good quality in 22 patients (88%). CONCLUSION: With this fluoroscopically triggered MR angiographic technique, high-quality, arterial phase, relatively motion immune angiograms can be routinely obtained.

Adolescent

The shoulder: adaptive motion correction of MR images.

PURPOSE: To evaluate an adaptive-motion-correction technique to reduce global motion in shoulder magnetic resonance (MR) images. MATERIALS AND METHODS: In the adaptive-motion-correction technique, interleaved navigator echoes are used to provide a measure of view-to-view displacement along the craniocaudal direction for each image echo in the acquisition. The information is then retrospectively applied to the k-space data to correct for global shoulder motion. This algorithm was evaluated in a series of 143 consecutive patient shoulder examinations by comparing the original image set for each patient with the same image set after retrospective correction by means of this algorithm. RESULTS: The average amplitude of craniocaudal motion was 1.4 mm. Image degradation due to motion was apparent in 100 (70%) of the 143 examinations. Application of the adaptive-motion-correction technique improved image quality in 73 (73%) of these 100 examinations or 51% of all 143 examinations. CONCLUSION: Adaptive motion correction improved image quality in approximately three-quarters of the examinations in which motion was present.

Humans

Multiple breathhold 3D time-of-flight MR angiography of the renal arteries.

A technique is described for angiographic imaging of the renal arteries with acquisition performed over several periods of suspended respiration. The 3D Fourier transform (FT) gradient-echo angiographic sequence uses magnetization preparation and appropriately chosen delay times for background nulling and time-of-flight enhancement of the vasculature. The sequence was applied to 10 volunteers, each of whom was imaged in three ways: (i) over a series of breathholds in which feedback was provided to enable reproducible breathholding; (ii) over a series of breathholds with no feedback; and (iii) over continuous respiration. Results were evaluated by measuring the transverse extent of the well-delineated renal vasculature and by noting the distal extent of the vasculature branching (main, segmental, and interlobar branches). The transverse extent of renal vasculature visible with breathhold feedback, breathholding, and free breathing was 6.1 +/- 0.9 cm, 5.0 +/- 1.8 cm, and 4.0 +/- 1.4 cm, respectively (mean +/- SD). Breathhold feedback enabled visualization of segmental renal arteries bilaterally in all 10 volunteers.

Fourier Analysis

Algorithms for extracting motion information from navigator echoes.

Algorithms to reliably detect motion in navigator echoes are crucial to many MRI motion suppression techniques. The accuracy of these algorithms is affected by noise and deformation of navigator echo profile caused by physiologic motion. This study compared the performance of algorithms based on correlation and least squares for extracting displacement information from motion-monitoring navigator echoes, using computer simulation and in vivo imaging. The least squares algorithm was determined to be of higher accuracy than the correlation algorithm against errors caused by noise and profile deformation.

Algorithms

Magnetic resonance imaging of transverse acoustic strain waves.

We describe a phase contrast based MRI technique with high sensitivity to cyclic displacement that is capable of quantitatively imaging acoustic strain waves in tissue-like materials. A formalism for considering gradient waveforms as basis functions to measure arbitrary cyclic motion waveforms is introduced. Experiments with tissue-like agarose gel phantoms show that it is possible to measure small cyclic displacements at a submicron level by an appropriate choice of the applied gradient basis function and to use this capability to observe the spatial and temporal pattern of displacements caused by acoustic strain waves. The propagation characteristics of strain waves are determined by the mechanical properties of the media. It is therefore possible to use this technique to noninvasively estimate material properties such as elastic modulus.

Acoustics

Real-time adaptive motion correction in functional MRI.

Functional magnetic resonance imaging (fMRI) of the brain is often degraded by bulk head motion. Algorithms that address this by retrospective re-registration of images in an fMRI time series are all fundamentally limited by any motion that occurs through-plane. Here, a technique is described that can account for such motion by prospective correction in real time. A navigator echo is used before every image acquisition to detect superior/inferior displacements of the head. The displacement information is then used to adjust the plane of excitation of the ensuing single-shot echo-planar fMRI axial image. These correction updates can be completed in 100 mm with motion sensitivity at least as small as 0.5 mm. The efficacy of this method is documented in phantom and human studies.

Brain

Dynamic MR digital subtraction angiography using contrast enhancement, fast data acquisition, and complex subtraction.

A dynamic MR angiography technique, MR digital subtraction angiography (MR DSA), is proposed using fast acquisition, contrast enhancement, and complex subtraction. When a bolus of contrast is injected into a patient, data acquisition begins, dynamically acquiring a thick slab using a fast gradient echo sequence for 10-100 s. Similar to x-ray DSA, a mask is selected from the images without contrast enhancement, and later images are subtracted from the mask to generate angiograms. Complex subtraction is used to overcome the partial volume effects related to the phase difference between the flowing and stationary magnetization in a voxel. Vessel signal is the enhancement of flow magnetization resulting from the contrast bolus. MR DSA was performed in 28 patients, including vessels in the lungs, brains, legs, abdomen, and pelvis. All targeted vessels were well depicted with MR DSA. Corresponding dynamic information (contrast arrival time ta and duration of the arterial phase tav) was measured: ta/tav = 3.4/4.7 s for the lung, 10.3/4.9 s for the brain, 12.8/19.3 for the aorta, 15.2/12.6 s for the leg. MR DSA can provide dynamic angiographic images using a very short acquisition time.

Abdomen

3D MR angiography of pulmonary arteries using real-time navigator gating and magnetization preparation.

An ECG-triggered magnetization-prepared segmented 3D fast gradient echo sequence was developed to perform pulmonary arterial MR angiography. A selective inversion recovery pulse was used in the magnetization preparation to suppress venous vasculature. A real-time gating technique based on navigator echoes was implemented to reduce respiration effects. Pencil-beam navigator echoes were acquired immediately before and after the readout train and processed in real-time to dynamically measure the diaphragm position, which was used to control data acquisition with an accept-or-reject-reacquire logic. In a study of 10 volunteers, a gated 3D acquisition with 28 slices required on average approximately 4 min of acquisition time, and six to seven segmental arteries related to the interlobar trunk of the pulmonary artery were depicted. The use of SIR pulse reduced venous signal by 99%. The gated acquisitions were superior to the ungated acquisitions (n = 10, P < 0.005). The real-time navigator gating technique is effective for reduction of respiration effects and thereby makes high resolution 3D MRA of the pulmonary arteries feasible.

Algorithms

Cardiac magnetic resonance fluoroscopy.

A technique is described for high speed interactive imaging of the heart with either white or black blood contrast. Thirty-two views of a segmented, magnetization-prepared gradient echo sequence are acquired during diastole. Using three-quarter partial Fourier sampling, data for a complete 128 x 128 image are acquired in three cardiac cycles. High speed reconstruction provides an image update of each cardiac cycle 159 ms after measurement. An independent graphical user interface facilitates interactive control of section localization and contrast by permitting pulse sequence parameter modification during scanning. The efficiency and image quality of the cardiac MR fluoroscopy technique were evaluated in 11 subjects. Compared with the conventional graphic prescription method, the cardiac fluoroscopy technique provides an approximate eightfold reduction in the time required to obtain subject-specific double oblique sections. Image quality for these scout acquisitions performed during free breathing was sufficient to identify small cardiac structures.

Coronary Angiography

Detection of colorectal polyps by computed tomographic colography: feasibility of a novel technique.

BACKGROUND & AIMS: Computed tomographic colography (CTC) represents a novel technique for colorectal polyp detection. A prospective study was undertaken to determine the optimal CTC scanning parameters based on an artificial colon model and to assess the feasibility of CTC to detect clinically significant colorectal polyps. METHODS: A colon model was scanned by helical computed tomography at multiple parameters. Reformatted two-dimensional and three-dimensional images were then graded for polyp detection and image quality. Subsequently, 10 patients with known colon polyps underwent CTC immediately before colonoscopy. The number of polyps detected by two radiologists using CTC were compared with colonoscopy results that served as the gold standard. RESULTS: The optimal scanning parameters in the colon model were 5-mm collimation, 5 mm/s table speed, and 1-mm reconstruction interval. Ten patients had 30 polyps (range, 0.2-2.0 cm) by colonscopy, and all polyps > or = 0.5 cm were adenomas. Polyp detection by CTC for both observers was 100% (5 of 5) > or = 1 cm, 71% (5 of 7) between 0.5 and 0.9 cm, and 11%-28% (2-5 of 18) < 0.5 cm. CONCLUSIONS: Based on this small, unblinded pilot study, CTC is feasible for colorectal polyp detection > or = 0.5 cm in diameter.

Aged

Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography.

PURPOSE: To test the hypothesis that respiration effects in three-dimensional (3D) coronary magnetic resonance (MR) imaging can be reduced with navigator-echo-based gating or triggering according to the superior-inferior position of the diaphragm. MATERIALS AND METHODS: Real-time respiratory gating and respiratory triggering (breath hold with feedback) were implemented with navigator echoes in a magnetization-prepared, segmented, 3D coronary imaging sequence. The two techniques were first tested with a motion phantom. An imaging protocol that compared real-time respiratory-gated acquisition, real-time respiratory-triggered acquisition, and continuous acquisition was then evaluated in six healthy subjects. RESULTS: Real-time respiratory-gated and respiratory-triggered acquisition were superior to continuous acquisition with two signals averaged (P = .025). The performance of the gated acquisition was about the same as that of the triggered acquisition (P = .05). CONCLUSION: Navigator-echo-based, real-time respiratory-gating and respiratory-triggering techniques are practical methods for effective reduction of respiration effects in coronary MR imaging.

Adult