PubMed Health⌕ Search

Biomedical subjects

R L Goble

Publications and source records attributed to R L Goble.

4 recordsLinked to original sources

Comparison of contact site cancer potency across dose routes: case study with epichlorohydrin.

Risk assessment for airborne carcinogens is often limited by a lack of inhalation bioassay data. While extrapolation from oral-based cancer potency factors may be possible for some agents, this is not considered feasible for contact site carcinogens. The change in contact sites (oral: g.i. tract; inhalation: respiratory tract) when switching dose routes leads to possible differences in tissue sensitivity as well as chemical delivery. This research evaluates the feasibility to extrapolate across dose routes for a contact site carcinogen through a case study with epichlorohydrin (EPI). EPI cancer potency at contact sites is compared across three bioassays involving different dose routes (gavage, drinking water, inhalation) through the use of dosimetry models to adjust for EPI delivery to contact sites. Results indicate a large disparity (two orders of magnitude) in potency across the three routes of administration when expressed as the externally applied dose. However, when expressed as peak delivered dose, inhalation and oral potency estimates are similar and overall, the three potency estimates are within a factor of seven. The results suggest that contact site response to EPI is more dependent upon the rate than the route of delivery, with peak concentration the best way to extrapolate across dose routes. These results cannot be projected to other carcinogens without further study.

Administration, Inhalation↗

A new device for continuous ambulatory central venous pressure measurement.

We have developed a device for continuous direct measurement of human central venous pressure (CVP) during space flight. Normal resting CVP is typically in the range of 5-10 mmHg; in zero gravity, the expected changes are +/- 5 mmHg or less. A 1-mm Hg change in CVP can represent a substantial intravascular fluid shift. The device is small, battery powered, and designed to run for at least 24 hr. Pressure is measured in a saline solution-filled catheter inserted into a central vein. The transducer is placed in the axilla at the level of the catheter tip to offset hydrostatic gradients. A pump and an electronic system mount on the leg. This assembly provides a slow, continuous infusion of heparinized saline solution to maintain the patency of the catheter. The electronic system generates a digital display in mm Hg, an analog output, and a visible and audible alarm for excessive pressure. An air-filled syringe allows for a two-point calibration (zero and a positive pressure generated by measured compression of a known gas volume). A two-failure tolerant system minimizes electric shock hazards. Two latex diaphragms separate the saline solution from the transducer surface, and the electronic system and pump chamber are in separate enclosures. A clear polycarbonate case allows bubbles to be seen. The unit has been tested for pump function, temperature stability, drift, and accuracy. We conclude that this approach provides a unit with sufficient stability, accuracy, and temperature insensitivity for measuring ambulatory CVP for up to 28 hr. The design may be suitable for ambulatory measurement of other intravascular and intracardiac pressures.

Catheterization, Central Venous↗

Device for rapid quantification of human carotid baroreceptor-cardiac reflex responses.

We designed, constructed, and evaluated a new device to characterize the human carotid baroreceptor-cardiac reflex response relation rapidly. We designed this system for study of reflex responses of astronauts before, during, and after space travel. The system comprises a new tightly sealing silicone rubber neck chamber, a stepping motor-driven electro-deposited nickel bellows pressure system, capable of delivering sequential R-wave-triggered neck chamber pressure changes between +40 and -65 mmHg, and a microprocessor-based electronics system for control of pressure steps and analysis and display of responses. This new system provokes classic sigmoid baroreceptor-cardiac reflex responses with threshold, linear, and saturation ranges in most human volunteers during one held expiration.

Biomedical Engineering↗